• Title/Summary/Keyword: Unit level

Search Result 3,463, Processing Time 0.029 seconds

New Arc Chamber to Improve Breaking Capacity (차단용량 향상을 위한 신소호 구조)

  • Park, Jin-Young;Cho, Hea-Yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.321-326
    • /
    • 2012
  • The mechanism unit, arc chamber and trip unit are imperative components of MCCB which will decide the level of performance of MCCB. Among them, Arc chamber unit is used for extinguishing arc rapidly of fault current and induce the arc inside of grid. At that time inducing arc will split into parts and cooled rapidly so the arc would disappear. This paper suggests new arc chamber unit to improve arc extinguishing performance with optimum design and are applied to actual products based on the results.

Design of LCD Backlight Unit Coupled with Micro Fresnel Lens Array (배열형 소형 프레넬 렌즈가 결합된 LCD 백라이트의 설계)

  • Jeong, Man-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.1-7
    • /
    • 2006
  • A light guided plate coupled with the micro Fresnel lens array(MFTA) is designed to improve the efficiency of the LCD backlight unit. Blazed Frenel lens and binary multi-level Fresnel lens are adapted for the MFLA. This type of MFLA can replace the prism sheet and diffuser sheet which are used for the conventional type of the LCD backlight unit. The luminance and uniformity are calculated to verify the performance of the MFLA type LCD backlight unit.

Stochastic FMECA Assessment for Combustion-Turbine Generating Unit in Order to RCM Schedule (복합화력발전기의 신뢰도 기반 유지보수를 위한 확률론적 FMECA 평가)

  • Joo, Jae-Myung;Lee, Seung-Hyuk;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.351-353
    • /
    • 2006
  • Preventive maintenance can avail the generating unit to reduce cost and gain more profit in a competitive supply-side power market. so, it is necessary to perform reliability analysis on the systems in which reliability is essential. In this paper, FMECA assessment adopted using real historical failure data in Korean power plants for apply RCM analytical method. The stochastic FMECA is an engineering analysis and a core activity performed by reliability engineers to review the effects of probable failure modes of generating unit and assemblies of the power system on system performance. Optimal RCM schedule which is considered the severity level of each generating unit and failure probability from failure prediction of generating unit can be planned using proposed FMECA with IOE index.

  • PDF

Design and Implementation of an Interface Unit for Analysis of a CAN-Based Control System (CAN 기반 제어 시스템 분석을 위한 인터페이스 유닛 설계 및 구현)

  • Park, Byung-Ryuel;Jeong, Gu-Min;Ahn, Hyun-Sik;Kim, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.195-197
    • /
    • 2006
  • In this paper, an interface unit is designed to efficiently monitor transmission data in Controller Area Network(CAN)-based control systems. The CAN uses a serial multi master communication protocol that efficiently supports distributed real-time control with a very high level of data integrity, and communication speeds of up to 1Mbps. The interface unit is composed of a DSP controller which collects data on the CAN bus and transfers data to a personal computer via serial communication to save and display of interesting signals. The experimental system consists of three DSP controllers which represent electronic control units of a vehicle, an interface unit for analysing the data on the bus, and a graphic monitoring program coded on the Windows platform. The validity and the effectiveness of the proposed simple type of CAN interface unit are shown through the experimental results.

  • PDF

PERIODIC SAFETY REVIEW ON KORI UNIT 1 (고리 1호기 주기적안전성 평가)

  • Kim, Tae-Ryong
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.403-414
    • /
    • 2003
  • Periodic safety review on Kori Unit 1 has been successfully done for the first time in Korea. 11 safety factors of the review were fully evaluated in accordance with the domestic legal system. Although it is the oldest nuclear power plant in Korea, Kori Unit 1 was found to have maintained good operating conditions and continuously enhanced its safety by implementing post-TMI action plans and other safety issues, such as replacing steam generators and process/control system. It can be therefore confirmed that safe operation of Kori Unit 1 is guaranteed until next periodic safety review. Nevertheless, some corrective action items were recommended to enhance further its safety level, such as equipment qualification, additional ageing management program, strengthening of some procedures related to administration and human factor. The results of PSR can be utilized for the continued operation beyond the design life as long as the plant safety is maintained and improved. Experiences of the PSR on Kori Unit 1 can be also applied to PSR on other plants.

  • PDF

A Study on Standard Unit Price Analysis of e-learning & Postal Distance Learning (인터넷 및 우편 원격 기관 훈련비용 기준단가 분석 연구 공학교육에 관한 연구)

  • Rha, Hyeon-Mi
    • Journal of Engineering Education Research
    • /
    • v.14 no.3
    • /
    • pp.61-71
    • /
    • 2011
  • Korea has introduced the levy-grand system in the vocational learning finance. The standard unit price system of training cost was utilized in the distribution of training budget and the reimbursement system including total or partial training cost return has been operated in the corporate training after completing the learning course particularly. The standard unit price was calculated in the base of analyzing on supporting budget by the government per training institutions and corporate payment decision to learning institutions. The proposing standard unit price system of training cost was analyzed in the current standard price unit of training cost and then an improvement policy and the implication are derived from it. At the result of this study, the current government supporting level to e-learning and postal distance learning indicates good status.

An Efficient Priority Based Unit Commitment using the Unit Operation Costs and the Probabilistic Reserve Requirements (확률적 운전예비력 및 운전비단가 우선순위법에 의한 화력시스텝의 실제적인 기동- 정지계획)

  • 이봉용;심건보;김정훈
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.6
    • /
    • pp.331-338
    • /
    • 1988
  • A simple algorithm is presented for solving the thermal unit commitment problem which is one of very important areas in economic operation of power systems. This algorithm is based on simple priority ordering by the unit operation cost and it is shown that the operation cost of chosen sets of generators is the minimum. The proposed method differs from the conventional priority-based formulations in that the unit operation are calculated in every load level. Further the poerating reserve requiements are satisfied by the newly derived analytical security function or the expectation of reserve. The proposed method is proven to be very simple, accurate and efficient in a sample system.

  • PDF

Application of Four-season Dedicated Outdoor Air Handling Unit in Central and Personal Air-conditioning (중앙공조 및 개별공조에서의 외조기 적용)

  • Park, Seung-Tae;Kim, Young-Il;Lee, Tae-Ho;Choi, Se-Young
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.591-596
    • /
    • 2008
  • The present study has been conducted to study the performance of dedicated outdoor air handling unit in central and personal air-conditioning. With conventional central and personal air-conditioning systems which are designed according to the maximum load, humidity increase above comfort level can not be avoided as the cooling load decreases. The adoption of dedicated outdoor air handling unit, however, can solve this problem. Moreover, the dedicated outdoor air handling unit has the characteristics of anti-bacteria due to dry coil, energy saving and good indoor air quality. During cooling seasons, dedicated outdoor air handling unit can save energy up to 30% than the conventional cooling+reheating system for controlling both temperature and humidity.

  • PDF

Damping Patch Placement on Outdoor Unit of Air-conditioner by Using Structural Intensity Technique (구조 인텐서티법을 이용한 에어컨 실외기의 제진재 적용)

  • 김규식;진심원;정인화;이정우;강연준
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.577-585
    • /
    • 2004
  • In this paper, reactive shearing structural intensity method is extended to damping patches placement on outer panels of outdoor unit of air-conditioner to reduce its structural borne noise. The structural intensity is calculated from the normal velocities of structures that are measured by using a laser scanning vibrometer, and $textsc{k}$-space (wave-number domain) signal processing is used to obtain the spatial derivatives in formulation of structural intensity. This method is applied to the outdoor unit of air-conditioner on shaker-exciting mode and operating mode. and then damping patches are placed over area of high reactive shearing structural intensity for reducing the radiated noise. Experimental results show the largest reduction of sound pressure level of an outdoor unit by appling small damping patches to optimal position.

Video Event Detection according to Generating of Semantic Unit based on Moving Object (객체 움직임의 의미적 단위 생성을 통한 비디오 이벤트 검출)

  • Shin, Ju-Hyun;Baek, Sun-Kyoung;Kim, Pan-Koo
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.2
    • /
    • pp.143-152
    • /
    • 2008
  • Nowadays, many investigators are studying various methodologies concerning event expression for semantic retrieval of video data. However, most of the parts are still using annotation based retrieval that is defined into annotation of each data and content based retrieval using low-level features. So, we propose a method of creation of the motion unit and extracting event through the unit for the more semantic retrieval than existing methods. First, we classify motions by event unit. Second, we define semantic unit about classified motion of object. For using these to event extraction, we create rules that are able to match the low-level features, from which we are able to retrieve semantic event as a unit of video shot. For the evaluation of availability, we execute an experiment of extraction of semantic event in video image and get approximately 80% precision rate.

  • PDF