• Title/Summary/Keyword: Unit Volume

Search Result 1,236, Processing Time 0.025 seconds

HU Threshold Value for IV Catheter Fragment in Peripheral Vein of Volume Rendering 3D MDCT Imaging (정맥 내의 IV 카테터 조각을 3D MDCT 볼륨렌더링 영상으로 구현하기 위한 HU 임계치)

  • Jang, Keun-Jo;Kweon, Dae-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.4
    • /
    • pp.206-212
    • /
    • 2007
  • To evaluate the HU value of the IV catheter fragment of CT on the accuracy and size in the peripheral vein. Pilot study of profile and table functions on PC by software was calculated of HU value of IV catheter fragment. This study demonstrates the utility of volume rendering technique to localize a small, subtle IV catheter, which can easily be reformatted of MDCT reformations. IV catheter fragment optimal image described as threshold range. Volume rendering of HU using a MDCT is an excellent method for evaluation the IV catheter fragment in three dimension.

Numerical prediction of hydrogen storaging performance of finned metal hybride beds (휜이 달린 수소저항합금 베드의 수소저장 성능의 수치적 예측)

  • Kim, Myeong-Chan;Lee, Sang-Yong;Gu, Jae-Hak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.520-529
    • /
    • 1998
  • Heat and mass transfer behaviors of metal hydride beds were predicted by solving a set of volume-averaged equations numerically both for the gas (hydrogen) and the solid(metal hydride) phases. Time variations of temperature and hydrogen concentration ratio distributions were obtained for internally cooled, cylindrical-shaped beds with metal(aluminum) fins imbedded in them. Also, time variations of the space-averaged hydrogen concentration ratio were obtained. Temperature and velocity of the coolant, hydrogen pressure at the gas inlet, and the fin spacing were taken as the parameters. The hydrogen absorption rate increases with the higher velocity and the lower temperature of the coolant, and with the decrease of the fin spacing. Increasing of the hydrogen pressure at the gas inlet also promotes the rate of absorption though the increasing rate gradually slows down. The amount of the hydrogen storage per unit volume of the bed decreases with the tighter fin spacing despite of the higher absorption rate ; therefore, there should be an optimum fin spacing for a given volume of the system and the amount of the hydrogen storage, in which the absorption rate is the highest.

Comparison of Traction Motor design and characteristics for battery driven hybrid tram (무가선 트램용 추진 전동기 설계 및 특성 비교)

  • Ham, Sang-Hwan;Kim, Kwang-Soo;Kim, Mi-Jung;Lee, Hyung-Woo;Lee, Ju
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1383-1388
    • /
    • 2010
  • The latest generation of tram is low-floor design, various nations in europe and japan have developed battery driven hybrid trams that combine battery and wiring. Battery driven tram system is achieved by contactless power supply system, thus system is needed high efficiency, high power and low weight traction motor for maximization of energy efficiency. Research from abroad is still in induction motor(IM) application, and it is not meet the efficiency and the power per unit volume in IPMSM. In this paper, we design compare IM and IPMSM to apply battery driven tram, and then compare these motors. To design the motor, we estimate the loading condition at first. Loading condition includes rolling resistance, air-drag resistance, and slope resistance. Based on the loading condition by estimation, we determine the power and compute rated voltage and rated current. In this paper, voltage is limited by battery voltage level. As a result, volume about IM is 1.98 times bigger than IPMSM under same condition. Even though IPMSM is bigger than IM in power density per volume, we consider more factors for actual application because there are demagnetization of permanent magnet in IPMSM and so on by external environment conditions.

  • PDF

Audio Mixer Algorithm for Enhancing Speech Quality of Multi-party Audio Telephony (다자간 음성통화 품질 향상을 위한 오디오 믹서 알고리즘)

  • Ryu, Sang-Hyeon;Kim, Hyoung-Gook
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.541-547
    • /
    • 2013
  • The speech quality of multi-party audio telephony between two, three or more participants is decreased by audio volume imbalance, audio volume saturation and noise level increase. To solve this issue, this paper proposes an advanced audio mixing algorithm for software-based multi-point control unit. Our approach is based on the combined voice activity detection and gain control technique that consists of a set of algorithms that classify audio signals, estimate audio volumes, adjust gain factors and mix audio signals of all channels. The proposed audio mixing algorithm is computationally efficient, delivers high-quality speech, and is suitable for use in any practical multi-party audio telephony.

The Effect of Dynamic Neuromuscular Stabilization (DNS) on the Respiratory Function of Subjects with Forward Head Posture (FHP)

  • Bae, Won-Sik
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.3
    • /
    • pp.55-64
    • /
    • 2021
  • PURPOSE: The purpose of this study was to apply dynamic neuromuscular stabilization (DNS) to subjects with forward head posture (FHP) and to compare its effects on respiratory function as against the conventional neck stabilization exercise and neck stretching and extensor strengthening exercises. METHODS: The whole-body posture measurement system was used to measure the degree of FHP, and a spirometer and a respiratory gas analyzer were used to measure the respiratory function. After the intervention was completed, the changes over time were analyzed in the DNS group, the neck stabilization exercise group, and the neck stretching and extensor strengthening exercise group. The inter-group difference in the changes was also analyzed. A repeated ANOVA was performed to compare the respiratory function according to the period between the three groups, and the least significant difference (LSD) method was used for the post hoc test. RESULTS: After the 6-week exercise period, respiratory functions, such as forced vital capacity (FVC), forced expiratory volume for 1 second (FEV1), forced expiratory volume for 1 sec/forced vital capacity (FEV1/FVC), maximum oxygen intake (VO2max), and the volume of expired gas (VE), significantly improved according to the period (p < .05), but no inter-group differences were found. CONCLUSION: DNS is an effective training method, and can be applied along with neck stabilization exercise and neck stretching and extensor strengthening exercises, which are widely used in clinical practice, to people with FHP who cannot directly perform neck exercises to improve their respiratory function.

Pore Size and Distribution of Polyester Fabrics Determined by Liquid Extraction Method (액체유출법에 의한 폴리에스테르 직물의 기공 크기 및 분포 측정)

  • Lee, Dong-Hwa;Yeo, Suk-Yeong;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.1
    • /
    • pp.206-216
    • /
    • 1997
  • The purpose of this study was to determine the pore size distributions (PSDs) of polyester woven fabrics by using liquid extraction method. Three types of PSDs-percent PSD, PSD per unit area of sample and PSD per unit weight of sample-were evaluated. Plain, twill and satin polyester fabrics with various fabric counts were used as specimens. Results showed that the interyarn PSDs reflected the fabric characteristics such as the fabric count and the weave type and the intrayarn PSDs reflected the thread characteristics such as the number of fibers, the fiber diameter, the thread diameter and the thread twist. Of three types of PSDs, the PSD per unit area of sample best reflect fabric and thread characteritics. As the fabric count decreased, rc increased and interyarn pore volume increased. The PSDs were skewed to the small pore sizes and the pore volumes decreased in the order of plain> twill> satin. As the number of fibers, the fiber diameter and the thread twist decreased, the intrayarn pore volumes were increased.

  • PDF

Experimental Study on the Friction and Wear Characteristics of Contact Sealing Unit for a Water Turbine (수차용 봉수장치의 마찰.마모특성에 관한 실험적 연구)

  • Kim, Chung-Kyun;Sihn, Ihn-Cheol;Lim, Kwang-Hyeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.515-518
    • /
    • 2006
  • This paper presents the friction and wear characteristics of contact type sealing unit for a water turbine of a small hydro-power generation, which Is to stop a leakage of a circulating water from a outside of an impeller to an inside of a rolling bearing. The surface wear strongly affect to the seal life of a mechanical face seal. In this study, the hardness of a stainless steel in which is a heat-treated is 892.8 in Vickers hardness and the hardness of silicone carbide of SiC is 714.1 in Vickers hardness. The surface hardness of a heat-treated stainless steel is 25% high compared with that of a ceramic material of SiC. The contact modes of rubbing surfaces aye a dry friction a water film friction and a mixed friction that is contaminated by a dust, silt and moistures, etc. These two factors of a contact rubbing modes and a material property are very important parameters on the tribological performance such as a friction and wear between a seal ring and a seal seat. The experimental result shows that the surface hardness of a seal material is very important on the friction coefficient and a wear volume. Thus, the results recommend higher hardness of a seal material, which may reduce a friction loss and increase a wear life of primary seal components

  • PDF

Thermal Conductivity of Carbon-Phenolic 8-Harness Satin Weave Composite (탄소/페놀릭 8-매 주자직 복합재료의 열전도도)

  • Woo, Kyeong-Sik;Goo, Nam-Seo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.9
    • /
    • pp.18-25
    • /
    • 2003
  • In this paper, thermal conductivities of carbon-phenolic 8-harness satin weave composite, ACP302, were measured and predicted. In the analysis, the satin weave unit cell was identified and modeled discretely by 3-dimensional finite elements, considering the interlaced fiber tow architecture microscopically. At the unit cell boundary, the corresponding periodic boundary conditions were applied. The results were analyzed to investigate the effect of microstructural parameters such as stacking phase shifts, waviness ratio, and fiber volume fraction. The conductivities were also obtained by experiments and compared with the numerical results.

An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental Apartment (도심(都心) 임대(賃貸)아파트의 에너지 및 상수(上水) 소비(消費) 특성(特性) 분석(分析))

  • Seo, Youn-Kyu;Kim, Joo-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.261-265
    • /
    • 2008
  • To solve the lack of housing, our country has supplied an enormous volume of apartments, and these days it occupies 75% of our buildings. As apartments occupy most of our housings, the rate of energy usage from them are also high. On this, setting apartment energy reduction as a target, by researching the actual conditions of energy consumption and drawing a basis data, we can apply this as a way of saving energy, rationalization of the scale of energy supply facilities and a standard when planning facilities. To grasp the present condition of energy usage of the urban rental apartment, this research analysed the use of electricity, gas and water monthly and annually of a rental apartment that is located in Daegu. The results showed that in 2003 the electricity usage was 1,198MWh but 1,315MWh in 2007, which means 9% of electricity usage increases every year. The average of water usage was $85,072m^2$ per year and they used $604.2MJ/m^2$ Typical energy consumption unit on $74.4m^2$ of area and $448.8MJ/m^2$ on $105.8m^2$. By showing the usage of energy and water of the urban rental apartment, understanding the tendency and preparing an Typical energy consumption unit standard through this research, apartments should use energy more efficiently.

  • PDF

Occupational Exposure to Steady Magnetic Fields and its Effect on Workers Blood Indices at an Electrolysis Unit

  • Ravandi, Mohammad Reza Ghotbi;Mardi, Hossein;Khanjani, Narges;Barkhordari, Abolfazl
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.255-260
    • /
    • 2016
  • The health effects of environmental and occupational exposure to steady magnetic fields is a matter of concern. The aim of this study was to evaluate the hematologic effects of exposure to steady magnetic fields at the electrolysis unit of a Copper complex. The population under study was the workers of the electrolysis unit of the copper refinery. The average steady magnetic field in the exposure group was 2.5 mT. The blood indices of workers exposure to steady magnetic fields after adjusting for confounders showed decreased white blood cells (except neutrophils) and increase in the number and volume of platelets. Red blood cells did not show any significant difference. Exposure to steady magnetic fields even in proposed safe limits may have hematologic effects on humans. There is a necessity for more research about the safe doses of exposure to magnetic fields.