• Title/Summary/Keyword: Unit Volume

Search Result 1,231, Processing Time 0.038 seconds

A Study on the Development of the Artigicial Eco Light-Weight Aggregate using EAF-Dust and Application of the Concrete (전기로제강 분진의 복합안정화 처리를 통한 에코이공경량골재의 개발 및 콘크리트 적용 연구)

  • Lee, Jin-Woo;Kim, Kyung-Min;Jung, Chul-Hee;Bae, Yeoun-Ki;Lee, Jae-Sam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.149-152
    • /
    • 2005
  • To make artificial light-weight aggregate with EAF-dust and estimate ability to apply to concrete, characteristics of the aggregate were considered in density, weight of unit volume, fineness modulus and so on. And then it was executed to experiments of the concrete mixed with the light-weight aggregate. As it was results that artificial light-weight aggregate with EAF-dust was heavier and more watertight than with only clay, concrete weight of unit volume was heavier than with expended clay aggregate. But it was regarded that concrete with EAF-dust artificial aggregate was able to field application as light-weight concrete because concrete of the weight of unit volume was lighter and compress strength and workability were similar to normal concrete.

  • PDF

Comparison of X-ray Shielding Performance according to the Weight of unit volume of Heavy Weight Concrete Utilizing Electric Arc Furnace Oxidizing Slag. (전기로 산화슬래그 골재를 활용한 중량 콘크리트의 단위 용적 중량 변화에 따른 X-선 차폐 성능 비교)

  • Lim, Hee Seob;Lee, Han Seung;Choi, jae Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.35-36
    • /
    • 2013
  • Electric arc furnace oxidizing slag from massively produced steel slag has been used in road bases and subbases, hot mix asphalt, and landfill. Electric arc furnace oxidizing slag contains iron (15%~30%) and has a high density of 3.0~3.7 ton/m3. Depending on the type and amount of concrete aggregates, the radiation-shielding characteristics can vary. Therefore, aggregates of electric arc furnace oxidizing slag can be considered for the production of radiation-shielding concrete. The experimental design of this study is experiments on Compressive strength experiments, X-ray irradiation experiments, and experiments related to the unit volume weight were carried out on hardened concrete. This experiment compared the performance evaluation of radiation shielding of concrete using electric arc furnace oxidizing slag.

  • PDF

Energy-based evaluation of liquefaction potential of uniform sands

  • Sonmezer, Yetis Bulent
    • Geomechanics and Engineering
    • /
    • v.17 no.2
    • /
    • pp.145-156
    • /
    • 2019
  • Since behaviors of loose, dense, silty sands vary under seismic loading, understanding the liquefaction mechanism of sandy soils continues to be an important challenges of geotechnical earthquake engineering. In this study, 36 deformation controlled cyclic simple shear tests were performed and the liquefaction potential of the sands was investigated using three different relative densities (40, 55, 70%), four different effective stresses (25, 50, 100, 150 kPa) and three different shear strain amplitudes (2, 3.5, 5%) by using energy based approach. Experiments revealed the relationship between per unit volume dissipated energy with effective stress, relative density and shear strain. The dissipate energy per unit volume was much less affected by shear strain than effective stress and relative density. In other words, the dissipated energy is strongly dependent on relative density and effective stress. These results show that the dissipated energy per unit volume is very useful and may contain the non-uniform loading conditions of the earthquake spectrum. When multiple regression analysis is performed on experiment results, a relationship is proposed that gives liquefaction energy of sandy soils depending on relative density and effective stress parameters.

The Properties of Strength Development of High Volume Fly Ash Concrete with Reduction of Unit Water Content (단위수량 저감에 따른 하이볼륨 플라이애시 콘크리트의 강도 발현 특성)

  • Choi, Yun-Wang;Park, Man-Seok;Choi, Byung-Keol;Oh, Sung-Rok
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.1
    • /
    • pp.46-51
    • /
    • 2014
  • In this study, strength development properties of high volume fly ash concrete was evaluated through compressive strength of concrete with reduction of unit water content. And concrete specimens were prepared according to target strength 3 level and variation of unit water content. As a result, the improved fluidity were obtained as a result of the ball bearing action of the spherical, the electrostatic repulsion and the particle size distribution of fly ash particles in case of using more than 50% fly ash. Through this, the mixture of fly ash has been shown to reduce the amount of water required in concrete. Also, the early strength of high volume fly ash concrete with reduction of unit water content was improved more about 66% than general concrete mixture.

A Novel Route to Realise High Degree of Graphitization in Carbon-carbon Composites Derived from Hard Carbons

  • Mathur, R.B.;Bahl, O.P.;Dhami, T.L.;Chauhan, S.K.
    • Carbon letters
    • /
    • v.4 no.3
    • /
    • pp.111-116
    • /
    • 2003
  • Carbon/carbon composites were developed using PAN based carbon fibres and phenolic resin as matrix in different volume fractions and heat treated to temperatures between $1000^{\circ}C$ to $2500^{\circ}C$. Although both the starting precursors are nongraphitizing hard carbons individually, their composites lead to very interesting properties e.g. x-ray diffractograms show the development of graphitic phase for composites having fibre volume fractions of 30~40%. Consequently the electrical resistivity of such composites reaches a value of $0.8\;m{\Omega}cm$, very close to highly graphitic material. However, it was found that by increasing the fibre volume fraction to 50~60%, the trend is reversed. Optical microscopy of the composites also reveals the development of strong columnar type microstructure at the fibre (matrix interface due to stress graphitization of the matrix. The study forcasts a unique possibility of producing high thermal conductivity carbon/carbon composites starting with carbon fibres in the chopped form only.

  • PDF

A sutdy on the District Unit Design by Traffic Assignment (교통량 배정을 고려한 지구단위설계에 관한 연구)

  • Jin, Jang-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1880-1888
    • /
    • 2012
  • This study tried to analyze traffic assignment volume by application of land use patterns and transport policies in District Unit Design. It is postulated a Toy network and various scenarios which are combined land use patterns and transport policies for analyzing change of assignment volume. As results, this study shows best District Unit Design technique is the policy that develop mid block and introduction of car free zone to inner 2 way streets. Worst design technique is the policy that introduction of joint car parking to mid block. And also worst design technique to residents who are living in inner block is the policy that just develop only one center zone.

An Analysis of Call Demands of Two Squads In Kyonggi Provincial fire and Disaster Headquarters (경기도 소방재난본부에 소속된 두 구급대의 출동수요 분석)

  • Uhm, Tai-Hwan
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.77-86
    • /
    • 2002
  • The purposes of this research which was conducted by surveying lost/added unit hours reports, unit hour demand analysis worksheets from prehospital care reports of two squads in Kyonggi Provincial Fire and Disaster Headquarters for 20 weeks (January 1, 2002 - May 20, 2002) are to get Unit Hour Utilizations. Call Demands such as Unit Hour Demand, Simple Average Demand, High Average Demand, Peak Average Demand, the High Actual Demand. The conclusions from this analysis were summarized as follows: (1) By revealing Unit Hour Produced 3223.9, Call Volume 964, Unit Hour Utilization 0.299 at the Squad A and Unit Hour Produced 3328.4, Call Volume 901, Unit Hour Utilization 0.271 at the Squad B induced Korean Squads to chance identification, definition, direction of Unit Hour Utilization. (2) By revealing Simple Average Demand 7.4 on Monday Tuesday, High Average Demand 9.6 on Tuesday Friday. Peak Average Demand 11.5 on Tuesday, the High Actual Demand 12 on Tuesday Wednesday at the Squad A and Simple Average Demand 6.8 on Sunday, High Average Demand 10.4 on Monday, Peak Average Demand 11.5 on Monday, the High Actual Demand 13 on Monday at the Squad B enabled Korean Squads to utilize System Status Management. (3) The Maximum Calls per Unit Hour were 115 for 23:00~23:59, the Minimum Calls per Unit Hour were 46 for 05:00~05:49 in two squads. The Maximum Calls per Unit Hour were 7.4 on Tuesday Saturday, the Minimum Calls per Unit Hour were 6.1 on Thursday at the Squad A. The Maximum Calls per Unit Hour were 7.3 on Monday Saturday, the Minimum Calls per Unit Hour were 5.6 on Thursday at the Squad B. (4) Analyzing demand for EMTs in the optimum emergency medical service of Korea, we have been able to utilize this Unit Hour Utilization in company with the established estimation methods such as international comparisons or the number of ambulances for scientific reasonable estimation. (5) These Call Demands which were limited to the demand time in this study will make us expect some following studies including demand time, demand time, demand map for Strategic Deployment.

  • PDF

The Estimation of Soil Conversion Factor using Digital Imagery (수치영상을 이용한 토량환산계수 산정)

  • 이종출;차성렬;장호식;김진수
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.169-174
    • /
    • 2003
  • Design of a rational earth volume conversion coefficient is required as the earth volume conversion coefficient may give great influence on construction work volume and construction costs in the civil engineering works where large-scaled earth volume is excavated. However, there are a great deal of difficulties in the calculation of the exact spoil surface earth and Insufficient earth volume by adopting the figures presented on the generally used design specifications which are not the results obtained from the selection tests in calculating the earth volume conversion coefficient. In this connection, it would be desirable to calculate the earth volume conversion coefficient by carrying out large-scaled site test adequate for the relevant environment. In consequence, this study aims at calculating the exact earth volume conversion coefficient of cutting and banking areas of weathering rocks in large-scaled construction sites where land is being developed into home lots. For this, we have excavated the respective 20 sites of the cutting and banking areas in the said site and then calculated the volume after the excavation. As a result, the relative exactness degree of the crossing was calculated at 0.5% in average. The relative exactness degree of 0.5% in the volume may be judged as an exact measurement as it corresponds to 0.17% of the relative exactness degree in the length measurement. We have calculated the exact earth volume conversion coefficient by the use of function ratio as per the wet unit weight and the indoor soil quality test as per volume calculated. And then we have found out minor differences as a result of the comparison and analysis with the earth volume conversion coefficient determined by the dry unit weight test as per sand replacement method. This may be judged as a rational design method for the calculation of earth volume conversion coefficient, as well as high reliability of site test as a precision photogrammetry is adopted for volume measurement of the irregular excavating areas.

  • PDF

Development of the Pilot System for Radioactive Laundry Waste Treatment Using UV Photo-Oxidation Process and Reverse Osmosis Membrane

  • Park, Se-Moon;Park, Jong-Kil;Kim, Jong-Bin;Shin, Sang-Woon;Lee, Myung-Chan
    • Nuclear Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.506-511
    • /
    • 1999
  • The pilot system for radioactive liquid laundry waste was developed with treatment capacity, 1ton/hr and set up in the Yong Kwang unit #4. The system is composed of tank module, RO systems and a UV/$H_2O$$_2$photo-oxidation unit. The RO system consists of the BW unit (low-pressure RO for brackish water desalination) and the SW unit (high-pressure RO for seawater desalination). The BW unit possesses 4 RO membranes and it can reduce the feed water volume down to 1/10. This concentrated feed water can be reduced again up to 1/10 in its volume in the SW unit composed of 4 RO membranes. The UV/$H_2O$$_2$ photo-oxidation process unit was used for the detergent degradation. The operation of the pilot system was carried out and verified in its capability through the continuous operation and concentration operation using the actual liquid waste from the power plant. The design criteria and data for industrialization were yielded. The efficiency of the UV/$H_2O$$_2$ photo-oxidation process and the optimum operational procedure were evaluated. The decontamination factors for radioactive cobalt and cesium were measured. This on-site test showed the experimental result in the DF$\geq$300 and volume reduction factor$\geq$100.

  • PDF

The Effects of Chest Physiotherapy on Sputum Amount, Lung Compliance, Tidal Volume and Oxygen Saturation of Intensive Care Unit Patients Mechanical Ventilated (흉부물리요법이 인공호흡기환자의 객담량, 폐유순도, 일회호흡량 및 산소포화도에 미치는 효과)

  • Seo, Kyoung-San;Kwon, En-Ok
    • Journal of Korean Critical Care Nursing
    • /
    • v.2 no.1
    • /
    • pp.15-25
    • /
    • 2009
  • Purpose: This study investigated the effects of chest physiotherapies on intensive care unit patients mechanical ventilated. Methods: Good lung down position, chest percussion, postural drainage was applied to patients who admitted to ICU. Each patients divided into four groups and each group received different treatments. Sputum amount, lung compliance, tidal volume and oxygen saturation were measured before treatment and immediately, and time flowing. Data was analyzed with frequency, percentage, ANOVA and paired t-test using via SPSSWIN 12.0 program. Results: There were significant differences in variables each characteristics of subjects. Chest percussion increased tidal volume, static lung compliance for the mean time. Desaturation related to suction. Conclusion: Chest percussion influences on lung compliance. Based on this study results and limitation, this study suggests repeated studies in various groups

  • PDF