• Title/Summary/Keyword: Unit Test Area

Search Result 404, Processing Time 0.027 seconds

Study on Real-time Parallel Processing Simulator for Performance Analysis of Missiles (유도탄 성능분석을 위한 실시간 병렬처리 시뮬레이터 연구)

  • Kim Byeong-Moon;Jung Soon-Key
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.1
    • /
    • pp.84-91
    • /
    • 2005
  • In this paper, we describe the real-time parallel processing simulator developed for the use of performance analysis of rolling missiles. The real-time parallel processing simulator developed here consists of seeker emulator generating infrared image signal on aircraft, real-time computer, host computer, system unit, and actual equipments such as auto-pilot processor and seeker processor. Software is developed from mathematic models, 6 degree-of-freedom module, aerodynamic module which are resided in real-time computer, and graphic user interface program resided in host computer. The real-time computer consists of six TIC-40 processors connected in parallel. The seeker emulator is designed by using analog circuits coupled with mechanical equipments. The system unit provides interface function to match impedance between the components and processes very small electrical signals. Also real launch unit of missiles is interfaced to simulator through system unit. In order to apply the real-time parallel processing simulator to performance analysis equipment of rolling missiles it is essential to perform the performance verification test of simulator.

Implementation of Health Behavior Education Concerning Liver Flukes among Village Health Volunteers in an Epidemic Area of Thailand

  • Kaewpitoon, Soraya J;Rujirakul, Ratana;Wakkuwattapong, Parichart;Matrakool, Likit;Tongtawee, Taweesak;Norkaew, Jun;Kujapun, Jirawoot;Kampangsri, Wilas;Kaewpitoon, Natthawut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.1713-1716
    • /
    • 2016
  • Background: Liver fluke infection is associated with cholangiocarcinoma; the bile duct cancer found frequently in the northeast and north of Thailand. Prevention and control particularly requires health education and behavior change. Objective: This study aimed to improve health behavior among village health volunteers (VHV) regarding liver fluke exposure in an epidemic area. Materials and Methods: A quasi-experimental study was performed during July 2015 to January 2016 in Sang Kha district of Surin province, Thailand. A total of 67 VHVs underwent a health education program (HEP) and data were collected on knowledge, attitude, and practice (KAP) before and after participation for HEP 3 months with a pre-designed questionnaire. The Students paired T-test was used for comparisons of mean KAP levels before/after the intervention. Results: The results revealed that knowledge (P-value=0.004), attitude (P-value=0.004), and practice level (P-value=0.000) were significantly improved after participation in the HBP. Attitude was significantly associated with knowledge (r=0.266, p<0.05), and practice (r=0.348, p<0.01). Conclusions: The implementation of health education among VHVs is feasible and increases their KAP. This improvement should have potential in liver fluke prevention and control in local communities in rural Thailand.

Effects of Pressure Biofeedback Unit Application on Muscle Strength and Balance in Total Knee Arthroplasty Patients during Exercise for Strengthening the Knee Extensor Muscle (무릎 폄근 강화 운동 동안 압력 생체되먹임 장비 적용이 무릎관절 전치환술 환자들의 근력과 균형에 미치는 영향)

  • Park, Jin;Park, Han-Kyu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.1
    • /
    • pp.101-108
    • /
    • 2021
  • Purpose : The purpose of this study is to verify the effect of selective muscle strengthening of the knee joint extensor muscles using a pressure biofeedback unit to improve knee extensor strength and the balance ability of total knee replacement patients. Through this, we tried to provide clinical information. Methods : In this study, 12 patients with total knee replacement were recruited from a rehabilitation hospital. They were divided into two groups: a feedback group (n=6) and a control group (n=6). All patients received 30 minutes of continuous passive motion and leg-strengthening exercises for 15 minutes five times a week for two weeks. Subjects performed knee extension exercises with or without biofeedback units in the sitting position. The knee extensor strength and balance ability were measured before and after exercise. Knee extensor strength was measured by Biodex system 3 and balance ability was measured by Balancia software. Results : Both the experimental group and the control group showed a significant difference in the muscle strength of the knee joint extensor muscles after intervention (p<.05). In comparison, the experimental group showed a significant difference than the control group (p<.05). Both the experimental group and the control group showed a significant difference in the velocity average, path length, area 95 % center of pressure (COP), weight distribution, five times sit to stand test (FTSST) after intervention. In comparison, the experimental group showed a significant difference in velocity average, area 95 % COP, and FTSST than the control group (p<.05). Conclusion : In order to strengthen the knee extensor muscle and improve the balance ability in total knee replacement patients, it is necessary to consider providing pressure biofeedback unit during leg strengthening exercises.

BIST Design for Hazard controller in Pipeline System (Pipeline 시스템의 Hazard 검출기를 위한 BIST 설계)

  • 이한권;이현룡;장종권
    • Proceedings of the IEEK Conference
    • /
    • 2003.11b
    • /
    • pp.27-30
    • /
    • 2003
  • The recent technology developments introduce new difficulties into the test process by the increased complexity of the chip. Most widely used method for testing high complexity and embedded systems is built-in self-test(BIST). In this paper, we describe 5-stage pipeline system as circuit under testing(CUT) and proposed a BIST scheme for the hazard detection unit of the pipeline system. The proposed BIST scheme can generate sequential instruction sets by pseudo-random pattern generator that can detect all hazard issues and compare the expected hazard signals with those of the pipelined system. Although BIST schemes require additional area in the system, it proves to provide a low-cost test solution and significantly reduce the test time.

  • PDF

Automatic UML-based Test Data Generating Tool: AUTEG (UML기반의 테스트 데이타 자동생성 도구 : AUTEG)

  • Kim, Cheong-Ah;Choi, Byoung-Ju
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.3
    • /
    • pp.268-276
    • /
    • 2002
  • In this paper we suggest a method to produce automatically teat data using UML development diagrams, and analytically describe the application of a tool, Automatic UML-based Test Data Generation (AUTEG) developed using XML technology, to the examples of insurance system. Our AUTEG automatically generates test diagrams that enable to detect errors existing at the interface area between modules composing the whole system, along with test data by applying the existing white-box test technique to the test diagram. Our AUTEG can be applied to the integration test as well as the system test and using the tool, users may make the unit modules of the integration test into several groups.

THE EFFECT OF ND : YAG LASER IRRADIATION ON EXPOSURE OF THE DENTINAL TUBULES ON ROOT SURFACE IN EXTRACTED HUMAN TEETH;A SCANNING ELECTRON MICROSCOPIC STUDY (Nd : YAG laser 조사가 치근면 상아세관의 노출에 미치는 효과에 관한 주사전자현미경적 연구)

  • Cho, Jong-Hee;Kim, Byung-Ok;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.564-576
    • /
    • 1993
  • The purpose of this study was to evaluate the effects of Nd:YAG laser treatment on removal of smear layer and exposure of dentinal tubules. The experimental specimens were obtained from root planed surface of 30 human teeth which were extracted due to severe periodontal disease. The specimens were assigned randomly of three groups: root planed group, Tetracycline HCl(100mg/ml, 5min) group, and Nd:YAG laser ($Laser-35^{TM}$, U.S.A. 5 seconds )group. Nd:YAG laser group was divided into 4 subgroups according to 3.0W, 3.5W, 4.0W, 4.5W of power. The surface change of specimens were evaluated by scanning electron microscopy. The number of exposed dentinal tubules and percentage of area occupied by dentinal tubule orifices per unit area between each group was statistically analyzed by paired Student t-test. The results were as follows: 1. By root planing only, dentinal tubule was not exposed, but scale-like smear layer and parallel instrument tracks were resulted. 2. Tetracycline HCl treated surfaces exhibited the small number of partially exposed dentinal tubules with long orifices. The number($3.80{\pm}0.79$) of exposed dentinal tubules on Tetracycline HCl group was significantly less than that in laser groups above 3.5W of power(P<0.001), and the percentage ($0.68{\pm}0.19$) of area occufied by dentinal tubule orifices per unit area($192\;{\mu}m^2$) was significantly lower than that of any laser group(P<0.001). 3. The laser group irradiated with 4.5W of power showed both the most number($10.60{\pm}0.97$) of exposed dentinal tubules among the experimental groups, and the highest percentage($3.75{\pm}0.55\;%$) of area occupied by dentinal tubule orifices. 4. Energy Surge during laser pulsing and overlapping passes of the fiber resulted in melted and resolidified surface textures with lava-like appearance.

  • PDF

An Experimental Study on the Relation between Flow Stress and Vickers Hardness (유동응력과 비커스경도의 관계 실험적 연구)

  • 이충호
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.65-68
    • /
    • 1997
  • Vickers hardness is defined as indenting force per unit area indented by a pyramid-shaped diamond at the hardness test. It is well known that Vickers hardness has a direct relation with the flow stress of the strain-hardened material. This relation was theoretically investigated and the result was summerized in a form of algebraic equation in the last paper. In the present paper and experimental validation of this theoretical relation is given along with mathematical formulas for conversion of Vickers hardness into the flow stress in the strain-hardened material for practical use.

  • PDF

Seasonal Species Composition and Fluctuation of Fishes by Beam Trawl in Yeoja Bay (빔트롤을 이용한 여자만 어류의 계절별 종조성과 변동)

  • Lee, Sun-Kil;Seo, Young-Il;Kim, Joo-Il;Kim, Hee-Yong;Choi, Mun-Sung
    • Korean Journal of Ichthyology
    • /
    • v.23 no.3
    • /
    • pp.206-216
    • /
    • 2011
  • To investigate seasonal and yearly variation of fishes composition in Yeoja Bay of Korea, fisheries survey were carried out using beam trawl from 2006 to 2009. A total of 44 fish species were collected. The major dominant species were Pennahia argentatus, Thryssa adelae, Thryssa kammalensis and Cynoglossus joyneri, which were occupied over 63% total individuals, and 50% of wet weight. The diversity index (H') was about 1.62 (1.46~1.77) by seasons, and seasons of similarity by fishes were divided into two groups, which were March with December and June with September. ANOVA test showed that there were not significant difference between individuals and catch weight (kg) per unit area (km$^2$) by year and season, except for catch weight per unit area by season.

Design of a piezovibrocone and calibration chamber

  • Samui, Pijush;Sitharam, T.G.
    • Geomechanics and Engineering
    • /
    • v.2 no.3
    • /
    • pp.177-190
    • /
    • 2010
  • This paper presents the details of indigenous development of the piezovibrocone and calibration chamber. The developed cone has a cylindrical friction sleeve of $150cm^2$ surface area, capped with a $60^{\circ}$ apex angle conical tip of $15cm^2$ cross sectional area. It has a hydraulic shaker, coupled to the cone penetrometer with a linear displacement unit. The hydraulic shaker can produce cyclic load in different types of wave forms (sine, Hover sine, triangular, rectangular and external wave) at a range of frequency 1-10 Hz with maximum amplitude of 10 cm. The piezovibrocone can be driven at the standard rate of 2 cm/sec using a loading unit of 10 ton capacity. The calibration chamber is of size $2m{\times}2m{\times}2m$. The sides of the chamber and the top as well as the bottom portions are rigid. It has a provision to apply confining pressure (to a maximum value of $4kg/cm^2$) through the flexible rubber membrane inlined with the side walls of the calibration chamber. The preliminary static as well as dynamic cone penetration tests have been done sand in the calibration chamber. From the experimental results, an attempt has been made to classify the soil based on friction ratio ($f_R$) and the cone tip resistance ($q_c$).

Study on the Evaluation of End Bearing Capacity of Pre-Bored Piles for the SPT-N value (SPT-N값에 따른 매입말뚝의 선단지지력 특성 연구)

  • Seo, Dong-Nam;Choi, Sang-Ho;Kim, Jin-Sik;Kim, Seong-Cheol;Lee, Dong-Hyeon;Cho, Seong-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.133-134
    • /
    • 2020
  • The equation of end bearing capacity is applied differently depending on the type of pile, construction method, and load characteristics considering the construction standards. The bearing capacity equation of the design standard is presented in various ways according to the design conditions such as construction method and ground condition, etc. but, It does not reflect the ground strength according to the SPT-N value of weathered rock. This study analyzed the trend of allowable tip bearing capacity by pile diameter through about 480 dynamic loading tests conducted for the construction/quality management of piles for the last 6 years since 2015. The equation for the ultimate end bearing capacity per unit area according to the SPT-N value is presented. The proposed formula of ultimate end bearing capacity per unit area can be applied in the range of 15,000kN/m2 to 30,000kN/m2. The proposed formula, which complements the existing formula, enables pile design and construction/quality management.

  • PDF