• Title/Summary/Keyword: Unit Test Area

Search Result 407, Processing Time 0.024 seconds

Groundwater Investigation in Northwestern Part of Saudi Arabia (Saudi Arabia 북서부의 지하수조사)

  • 한정상;정수웅
    • Water for future
    • /
    • v.8 no.2
    • /
    • pp.30-40
    • /
    • 1975
  • Hydrogeological survey and geophysical prospecting have been carried out in Saudi Arabia for the purpose of finding groundwater in the soil and rock at the request of General trading company in Jeddah, Saudi Arabia. The surveyed area is located on $38^{\circ}-39^{\circ}$ 30' in longitude and $26^{\circ}-26^{\circ}$ 30' in latitude. The topography of this area is dominated by northwest southeast mountain range composed mostly of precambrian rocks and basalt of tertiary period. Geology is mainly composed of greenstone, granite, andesite, diorite rhyolite of pre-cambrian era and sandstone of cambrian period which are underlained by basalt and andesite of tertiary period and alluvium of quaternary unconformably. The instruments used in this investigation are TR-18B2 radioactivity unit which isjapanese patented and A.C. Terrameter, a resistivity meter manufactured by ABEM of Stockholm, Sweden. Radioactivity method has been conducted along the Alula-Khaybar road, totally 164Km by the car-borne. As a result of the above survey 16 places have been selected and these anomalies show 1.2N-1.6N compared to background of each area in intensity with width of 10-50m. Resistivity vertical profiling which made use of Schlumberger configuration method has been made over selected areas by radioactivity method to provide hydrogeological information for a water resources survey. The result of resistivity shows that good aquifers are located in the western part of surveyed area where sedimentary rock is distributed. The strata showing 10-50, ${\Omega}-m$ in resistivity are thought to be waterbearing layer. The variations in aquifer resistivity found, are thought to be due to verying clay content, which could be related to aquifer yield. It has proved impossible to detect small salinity variation in the buried aquifer by geophysics. As a result of resistivity prospecting 10 places are recommended to be drilled at the anomalies as shown attached map. yields from the proposed holes have been estimated approximately from $20m^3$ to $200m^3$ per day. Prior to drilling for groundwater, test boring using ${\c}4"$ should be drilled in order to obtain more reliable hydrogeological information for the construction of perfect wells.ells.

  • PDF

Evaluation of Impact Resistance of Steel Fiber and Organic Fiber Reinforced Concrete and Mortar

  • Kim, Gyu-Yong;Hwang, Heon-Kyu;Nam, Jeong-Soo;Kim, Hong-Seop;Park, Jong-Ho;Kim, Jeong-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.4
    • /
    • pp.377-385
    • /
    • 2012
  • In this study, the Impact resistance of steel fiber and organic fiber reinforced concrete and mortar was evaluated and the improvement in toughness resulting from an increase in compressive strength and mixing fiber for impact resistance on performance was examined. The types of fiber were steel fiber, PP and PVA, and these were mixed in at 0.1, 0.5 and 1.0 vol.%, respectively. Impact resistance is evaluated with an apparatus for testing impact resistance performance by high-speed projectile crash by gas-pressure. For the experimental conditions, Specimen size was $100{\times}100{\times}20$, 30mm ($width{\times}height{\times}thickness$). Projectile diameter was 7 and 10 mm and impact speed is 350m/s. After impact test, destruction grade, penetration depth, spalling thickness and crater area were evaluated. Through this evaluation, it was found that as compressive strength is increased, penetration is suppressed. In addition, as the mixing ratio of fiber is increased, the spalling thickness and crater area are suppressed. Organic fibers have lower density than the steel fiber, and population number per unit area is bigger. As a result, the improvement of impact resistance is more significant thanks to dispersion and degraded attachment performance.

Growth of Landscape Tree Species at Two Planting Densities in a Planting Pilot System for Reclaimed Dredging Areas (임해준설매립지 식물재배공정에서 밀도에 따른 조경수목의 생장)

  • Lee, Deok-Beom;Nam, Woong;Kwak, Young-Se;Jeong, In-Ho;Lee, Sang-Suk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.2
    • /
    • pp.114-123
    • /
    • 2009
  • To investigate the possible use of plants for landscaping in reclaimed soil, a planting pilot system experiment was performed over the course of four years in reclaimed dredging area with four species: Alnus firma, Alnus hirsuta, Pinus thunbergii, and Pyrachantha angustifolia for 4 years. The physicochemical characteristics of the tested soil showed that it was sandy through coming from a reclaimed dredging area. The average pH of the tested soil was 7.16(slight alkali), and electric conductivity(EC) was relatively low, $294{\mu}S/cm$, even though it came from a saltwater area. To test the effect of planting density vs. phytomass by plant specie from a planting basin, the experiment was designed using four plant species with high and low planting densities over 4 years. The planting conditions of the growth of landscape tree species exhibited growth height as follows: A. hirsuta, A. firma, P. thunbergii, and P. angustifolia, whill the DBH followed the order of A. hirsuta, A. firma, and P. thunbergii. The total phytomass of each plant was higher at low density planting areas than high density planting area in terms of total phytomass production and growth distribution in the reclaimed dredging area. Total phytomass per unit area increased as follows: A. hirsuta, A. firma, P. thunbergii, and P. angustifolia. The total phytomass per each tested plant was 2 times higher in low density planting areas than high density planting areas. Total phytomass per unit area, however, was similar or slighty higher in high density planting areas compared to low density areas. Among the tested plants, A. hirsuta showed the highest phytomass, implying that A. hirsuta adapted very well to the reclaimed area and has the capability of a fast growth, nitrogen fixation tree, and utilizing insoluble nutrients through inoculated root nodule bacteria. The yield of phytomass per individual in low density Alnus species was greater than that of the high density. However, those per unit areas had no difference in the density-dependent planting. The ratio of belowground to aboveground was $0.21{\sim}0.26$. Thus, it could be concluded that the Alnus species are potential candidates for ornamental tree species in reclaimed dredging areas. This study offers baseline data for the use of ornamental tree species in reclaimed dredging areas. Additional research is required for different ornamental species in order to increase phytomass of a planting conditions based on reclaimed dredging areas.

Sampling and Calibration Requirements for Optical Reflectance Soil Property Sensors for Korean Paddy Soils (광반사를 이용한 한국 논 토양 특성센서를 위한 샘플링과 캘리브레이션 요구조건)

  • Lee, Kyou-Seung;Lee, Dong-Hoon;Jung, In-Kyu;Chung, Sun-Ok;Sudduth, K.A.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.4
    • /
    • pp.260-268
    • /
    • 2008
  • Optical diffuse reflectance sensing has potential for rapid and reliable on-site estimation of soil properties. For good results, proper calibration to measured soil properties is required. One issue is whether it is necessary to develop calibrations using samples from the specific area or areas (e.g., field, soil series) in which the sensor will be applied, or whether a general "factory" calibration is sufficient. A further question is if specific calibration is required, how many sample points are needed. In this study, these issues were addressed using data from 42 paddy fields representing 14 distinct soil series accounting for 74% of the total Korean paddy field area. Partial least squares (PLS) regression was used to develop calibrations between soil properties and reflectance spectra. Model evaluation was based on coefficient of determination ($R^2$) root mean square error of prediction (RMSEP), and RPD, the ratio of standard deviation to RMSEP. When sample data from a soil series were included in the calibration stage (full information calibration), RPD values of prediction models were increased by 0.03 to 3.32, compared with results from calibration models not including data from the test soil series (calibration without site-specific information). Higher $R^2$ values were also obtained in most cases. Including some samples from the test soil series (hybrid calibration) generally increased RPD rapidly up to a certain number of sample points. A large portion of the potential improvement could be obtained by adding about 8 to 22 points, depending on the soil properties to be estimated, where the numbers were 10 to 18 for pH, 18-22 for EC, and 8 to 22 for total C. These results provide guidance on sampling and calibration requirements for NIR soil property estimation.

Study on High Density Activated Carbons for Electrode Materials of Supercapacitor (초고용량 커패시터 전극활성물질용 고밀도 활성탄 제조 및 특성 연구)

  • Roh, Kwang Chul;Park, Jin Bae;Lee, Chul-Tae;Park, Chul Wan
    • Applied Chemistry for Engineering
    • /
    • v.18 no.4
    • /
    • pp.381-385
    • /
    • 2007
  • High density activated carbons electrode materials, for supercapacitor were prepared by chemical KOH activation of cokes as the starting material under Ar atmosphere. By controlling the synthesis conditions and reducing KOH quantity in the activation step, the specific surface area of the product was decreased. BET surface area was measured to be $500{\sim}1260m^2/g$, and the electrode density was in the range of $0.68{\sim}0.83g/cm^3$. Volumetric specific capacitance (unit cell test) was as high as 20 F/cc, which corresponds to gravimetric specific capacitance of about 95 F/cc on the basis of half cell test. It should be noted that the specific capacitance of the activated carbons prepared in this study is superior to that of commercial activated carbons.

Soil displacement from frost heave on forest road cut-slopes

  • Lee, Myeong-Kyo;Lee, Joon-Woo;Choi, Sungmin;Kim, Hyoun-Sook
    • Korean Journal of Agricultural Science
    • /
    • v.45 no.2
    • /
    • pp.177-184
    • /
    • 2018
  • The frost heave process from repeated freezing and thawing actions in winter on forest road cut-slopes is important for forest road maintenance and management. This study investigated the damages of the forest heave process on forest road cut-slopes by measuring the changes in the road-cut surface elevation and sediment production and by conducting vegetation surveys which were aimed at providing information for forest road maintenance plans. The temperature and humidity differences were determined between the north and south cut-slopes. T-test showed that the north slope had a lower temperature and humidity than that of the south slope. Field observations also confirmed frozen soils on the north slopes, indicating that the north slopes are susceptible to frost heave. Sediment was converted to dry weight per unit area ($g/m^2$). T-test showed that the north slope produced more sediment than that of the south slope. The study confirmed that more frost heave occurred on the north cut-slopes than on the south cut-slopes. Vegetation surveys were conducted on five cut-slope plots. Considering the dominant species found above the cut-slopes, vegetations in all the plots are expected to succeed to pine and oak in the future. The dominant species appearing on the cut-slopes of the study area were exotic species because the elapsed time of the site was only 2 - 4 years.

The Behavior of Rammed Aggregate Piers (RAP) in Soft Ground (I) (연악지반의 쇄석다짐말뚝에 대한 거동 분석 (I))

  • Bae, Kyung-Tae;Lee, Chong-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.169-183
    • /
    • 2007
  • Numerical analysis was performed to investigate the behavior of rammed aggregate piers (RAP) in soft ground with various interface conditions, area replacement ratio, aspect ratio and surcharge loads of pile and soil. And field modulus load test was carried out to predict the input parameters. Field prototype (unit cell) tests are in progress to compare the result of numerical analysis. Also a modified load transfer equation of RAP on soft foundation was proposed. According to the results, the behavior of RAP depended on such as interface conditions, settlement characteristics (free strain) and stress concentration ratio. On the other hand, maximun stress concentration ratio increased as area replacement ratio and aspect ratio increased, and it was remarkably affected by surcharge loads.

Distribution of the Population at Risk of Cholangiocarcinoma in Bua Yai District, Nakhon Ratchasima of Thailand Using Google Map

  • Kaewpitoon, Soraya J;Rujirakul, Ratana;Sangkudloa, Amnat;Kaewthani, Sarochinee;Khemplila, Kritsakorn;Cherdjirapong, Karuna;Kujapun, Jirawoot;Norkaew, Jun;Chavengkun, Wasugree;Ponphimai, Sukanya;Polsripradist, Poowadol;Padchasuwan, Natnapa;Joosiri, Apinya;Wakkhuwattapong, Parichart;Loyd, Ryan A;Matrakool, Likit;Tongtawee, Taweesak;Panpimanmas, Sukij;Kaewpitoon, Natthawut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1433-1436
    • /
    • 2016
  • Background: Cholangiocarcinoma (CCA), a major problem of health in Thailand, particularly in Northeastern and Northern regions, is generally incurable and rapidly lethal because of presentation in stage 3 or 4. Early diagnosis of stage 1 and 2 could allow better survival. Therefore, this study aimed to provide a distribution map of populations at risk for CCA in BuaYai district of Nakhon Ratchasima province, Northeast Thailand. Materials and Methods: A cross-sectional survey was carried out in 10 sub-districts and 122 villages, during June and November 2015. The populations at risk for CCA were screened using the Korat CCA verbal screening test (KCVST) and then risk areas were displayed by using Google map (GM). Results: A total of 11,435 individuals from a 26,198 population completed the KCVST. The majority had a low score of risk for CCA (1-4 points; 93.3%). High scores with 6, 7 and 8 points accounted for 1.20%, 0.13% and 0.02%. The population at risk was found frequently in sub-district municipalities, followed by sub-district administrative organization and town municipalities, (F=396.220, P-value=0.000). Distribution mapping comprised 11 layers: 1, district; 2, local administrative organization; 3, hospital; 4, KCVST opisthorchiasis; 5, KCVST praziquantel used; 6, KCVST cholelithiasis; 7, KCVST raw fish consumption; 8, KCVST alcohol consumption; 9, KCVST pesticide used; 10, KCVST relative family with CCA; and 11, KCVST naive northeastern people. Geovisual display is now available online. Conclusions: This study indicated that the population at high risk of CCA in Bua Yai district is low, therefore setting a zero model project is possible. Key success factors for disease prevention and control need further study. GM production is suitable for further CCA surveillance and monitoring of the population with a high risk score in this area.

Late season commercial mosquito trap and host seeking activity evaluation against mosquitoes in a malarious area of the Republic of Korea

  • Buekett, Douglas-A.;Lee, Won-Ja;Lee, Kwan-Woo;Kim, Heung-Chul;Lee, Hee-Il;Lee, Jong-Soo;Shin, E-Hyun;Wirtz, Robert-A.;Cho, Hae-Wol;Ckaborn, David-M.;Coleman, Russel-E.;Kim, Wan-Y;Klein, Terry-A.
    • Parasites, Hosts and Diseases
    • /
    • v.40 no.1
    • /
    • pp.45-54
    • /
    • 2002
  • Field trials evaluating selected commercially available mosquito traps variously baited with light, carbon dioxide, and/or octenol were conducted from 18-27 September 2000 in a malarious area near Paekyeon-ri (Tongil-Chon) and Camp Greaves in Paju County, Kyonggi Province, Republic of Korea. The host-seeking activity for common mosquito species, including the primary vector of Japanese encephalitis, Culex tritaeniorhynchus Giles. was determined using hourly aspirator collections from a human and propane lantern-baited Shannon trap doting hours when temperatures exceeded $15^{\circ}C$. The total number of mosquitoes and number of each species captured during the test was compared using a block design. Significant differences were observed for the total number of mosquitoes collected, such that, the Mosquito MagnetTM with octenol > Shannon trap > ABC light trap with light and dry ice > Miniature Black Light trap (manufactured by John W. Hock) $\geq$ New Jersey Trap > ABC light trap with light only. Significant differences in numbers collected among trapes were noted for several species including: Aedes vexans (Meigen), Anopheles lesteri Baisas and Hu. An. sinensis Weidemann, An. sineroides Yamada, An. yatsushiroensis Miyazaki. Culex pipiens pallets Coquillett L., Cx. orientalis Edwards and Cx. tritaeniorhynchus. Host-seeking activity for most common species showed a similar bimodal pattern. Results from these field trap evaluations can significantly enhance current vector and disease surveillance efforts especially for the primary vector of Japanese encephalitis, Cx. tritaeniorhunchus.

A Study on Shear Behavior of High Strength Reinforced Concrete Beams (고강도 철근콘크리트 보의 전단거동에 관한 연구)

  • Kwak, Kae-Hwan;Park, Jong-Gun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.5
    • /
    • pp.68-79
    • /
    • 1998
  • In the years, the concern about high-strength concrete which is new material has been heightened as a result of active research and development. Recently, as the building structure has been being bigger, higher, longer and more specialized, the demand of material with high-strength concrete for building has been increasing. The demand of high -strength concrete is expected to increase with expansion of usage about the complex concrete structures such as bridge structure as well as nuclear plants, underground structures, hydraulic structures and arctic area sturctures. In this research, silica-fume was used as an admixture in order to get a high-strength concrete. Water/binder ration was limited no more than 18 percent and the amount of unit cement was increased. In this study, a number of trial in concrete mix was carried out to get optimal mix design, and the target slump with $10{\pm}2cm$ was set for in-situ construction. High-strength concrete with cylinder strength of 1,200kgf/$cm^2$ in the 28-days was produced and tested. The static test was carried out to measure the ultimate load, the initial load of flexural and diagonal cracking, crack patterns, fracture modes. The load versus strain and load versus deflection relations were obtained form the static test. The test results were compared with the shear strengths predicted by the equations of ACI code 318-89 and orther researchers. Based on the test results, shear strength equation of reinforced concrete beam using high strength concrete was proposed. Form an evaluation of the results of this experimental investigation, it was concluded that shear strength after diagonal tention cracking diminished with the increase in compressive strength for beams.

  • PDF