• Title/Summary/Keyword: Unit Test Area

Search Result 404, Processing Time 0.026 seconds

A Study on the Performance of Flat-plate Solar Air Collector and its Application to Grain Drying (평면식 태양열집열기를 이용한 곡물 건조개선에 관한 연구)

  • 민영봉;최규홍
    • Journal of Biosystems Engineering
    • /
    • v.3 no.2
    • /
    • pp.114-125
    • /
    • 1978
  • The use of petroleum fuels in grain drying causes problems of high cost and management. To solve these problems, it is required to study on soLar energy as an alternative to petroleum fuels for grain drying. The purposes of this study were to find out the optimum received area and air flow rate of a flat-plate solar air collector for grain drying and to assess its effects on grain drying with a small grain bin. The results of this study are summarized as follows ; 1. The calculated optimum tilt angles of the collector in the summer and autumn drying seasons were 20 and 50 degress, respectively, in suwon area. 2. The outlet temperature of the collector was $36^\circ C$ on the daily average with the maximum of $36^\circ C$ at 12:00 o clock. Solar radiation on the collector surface was 1.04 ly( 1 langley = 1 cal/$cm^2$) per minute on the daily average and 1.30 ly per minute on the maximum at 11:00am. The thermal efficiency of the collector was 62.4 percent on the daily average, and the air flow-rate per unit receiving are was 1.03 $m^3$/min/$m^2$.4. The calculated optimum receiving area and the air flow-rate per unit cubic volume for paddy in autumn drying season was 2 $m^2$ and 2$m^3$/min , respectively. 5. not significantly difference in the collector efficiency was appeared between the rotating and fixed type of solar collector. 6. For drying of wheat with 0.6 meter of the depth in the bin, approximately 9 hours were required to reduce the moisture content from 21.6% to 13% with air follow rate of 5 $m^3$/min an initial moisture per cubic meter of wheat and with air temperature of $52^\circ C$. 7. In the drying test of rough rice with a turning operation in a grain bin approximately 21 hours were required to reduced the moisture from 21% to 14.5% with airflow rate of 2 $m^3$/min per cubic meter of rice and the air temperature of $43.5^\circ C$. 8. Over-drying at the bottom and less -drying at the top of the grain mass was resulted from the high -temperature of drying air which was obtained from the flat-plate solar collector in this test. An appropriate operation should be prepared for the uniform moisture of the grain in the bin.

  • PDF

Evaluations on the Compaction Energy Effects on the Soil Compaction at Sub-Zero Temperature (영하에서의 다짐에너지에 따른 다짐 효과 평가)

  • Lee, Jeonghyeop;Hwang, Bumsik;Chae, Deokho;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.8
    • /
    • pp.13-20
    • /
    • 2015
  • Due to the population growth and exhaustion of resource, the development on the harsh environment such as cold weather is emerging as an alternative for new resource development. The permafrost area covers about 14 percent of the world's land area and the global construction market for such area is rapidly expanded. Whereas the developed countries have already recognition of the need for research of coldest place and invested heavily in technology development, the domestic technology for the coldest place development is less developed and related research has rarely been performed. There is not a detailed national specification standard for the strength and deformation properties of the earthworks at sub-zero temperature but simple field directions. Therefore, the D compaction tests were conducted on the sand with fine contents of 0%, 5%, 10% and 15% at room temperature ($18^{\circ}C$), $-3^{\circ}C$ and $-8^{\circ}C$ to investigate the effect of the compaction energy on the compacted soils at sub-zero temperatures. Based on the test results, the larger compaction energy, the larger maximum dry unit weight under sub-zero temperature and D type compaction at $-3^{\circ}C$ show similar max. dry unit weights as those obtained from the compaction at the room temperature. However, compaction at $-8^{\circ}C$ showed significant performance degradation regardless of the compaction energy.

Floating Point Unit Design for the IEEE754-2008 (IEEE754-2008을 위한 고속 부동소수점 연산기 설계)

  • Hwang, Jin-Ha;Kim, Hyun-Pil;Park, Sang-Su;Lee, Yong-Surk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.10
    • /
    • pp.82-90
    • /
    • 2011
  • Because of the development of Smart phone devices, the demands of high performance FPU(Floating-point Unit) becomes increasing. Therefore, we propose the high-speed single-/double-precision FPU design that includes an elementary add/sub unit and improved multiplier and compare and convert units. The most commonly used add/sub unit is optimized by the parallel rounding unit. The matrix operation is used in complex calculation something like a graphic calculation. We designed the Multiply-Add Fused(MAF) instead of multiplier to calculate the matrix more quickly. The branch instruction that is decided by the compare operation is very frequently used in various programs. We bypassed the result of the compare operation before all the pipeline processes ended to decrease the total execution time. And we included additional convert operations that are added in IEEE754-2008 standard. To verify our RTL designs, we chose four hundred thousand test vectors by weighted random method and simulated each unit. The FPU that was synthesized by Samsung's 45-nm low-power process satisfied the 600-MHz operation frequency. And we confirm a reduction in area by comparing the improved FPU with the existing FPU.

Evaluation of adenosine triphosphate testing for on-farm cleanliness monitoring compared to microbiological testing in an empty pig farrowing unit

  • Yi, Seung-Won;Cho, Ara;Kim, Eunju;Oh, Sang-Ik;Roh, Jae Hee;Jung, Young-Hun;Choe, Changyong;Yoo, Jae Gyu;Do, Yoon Jung
    • Journal of Animal Science and Technology
    • /
    • v.62 no.5
    • /
    • pp.682-691
    • /
    • 2020
  • Careful cleaning and disinfection of pigpens is essential to prevent disease spread and avoid the resultant economic losses. Hygiene in pigpens is generally evaluated by visual monitoring supplemented with bacteriological monitoring, which includes counting the total aerobic bacteria (TAB) and/or fecal indicator bacteria (FIB). However, these methods present drawbacks such as time and labor requirements. As adenosine triphosphate (ATP) is ubiquitous in all living organisms including microorganisms, this study aimed to directly compare the results of microbial assessment and ATP quantification, and to suggest possible detailed application methods of the ATP test for hygiene evaluation in pigpens of a farrowing unit. Before and after standard cleaning procedures, samples were collected from the floor corner, floor center, and feeding trough of four pigpens at different time points. No FIB were detected and both the TAB and ATP levels were significantly decreased in the floor center area after cleaning. FIB were continuously detected after cleaning and disinfection of the floor corners, and there was no significant ATP level reduction. The feeding trough did not show any significant difference in these values before and after cleaning, indicating insufficient cleaning of this area. The levels of TAB and ATP after cleaning were significantly correlated and the average ATP value was significantly lower in the absence of FIB than in their presence. In the absence of standard references, a more thorough hygiene management could be achieved evenly by supplementing cleaning or disinfection based on the lowest ATP results obtained at the cleanest test site, which in the present study was the floor center. Overall, these results indicate that the on-farm ATP test can be used to determine the cleanliness status, in addition to visual inspection, as an alternative to laboratory culture-based testing for the presence of microorganisms.

Evaluation of Deterioration of Epoxy Primer for Steel Bridge Coating using Image Processing and Electrochemical Impedance Spectroscopy (화상처리 기법과 전기화학적 임피던스 분광법을 이용한 강교 도장용 에폭시 하도 도료의 열화 평가)

  • Lee, Chan Young;Lee, Sang Hun;Park, Jin Hwan
    • Corrosion Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.53-61
    • /
    • 2009
  • In this study, both evaluations by visual imaging for exterior view of coating and by EIS were executed for epoxy primer coated specimens deteriorated by accelerated test, and comparison and analysis were carried out for 2 evaluation methods. In the comparison between total damaged area ratio acquired by image processing method and deterioration point, higher deterioration points were appeared for rusted specimens than for non-rusted specimens. It is attributed that deterioration point per unit area ratio given for rust is higher than for peeling. In the comparison between total damaged area ratio and EIS result, impedance of coating was largely decreased as about TEX>$10^4{\Omega}{\cdot}cm^2$ or less when rust area ratio is more than about 0.1%, and blistering area ratio is more than about 3%. Charge transfer resistance ($R_{ct}$) and double layer capacitance ($C_{dl}$) values were appeared for all specimens except 2 ones, which shows that water is accumulated and steel substrate is corroded at coated film-steel interface. In the comparison between deterioration point and EIS result, more than 10 points as deterioration point were given for specimens of below $10^6{\Omega}{\cdot}cm^2$ of impedance at low frequency. For specimens deteriorated by NORSOK cyclic test, impedance was lowest of all, though deterioration point was not high. It is thought to be attributed that coating system and accelerated deterioration condition of cyclic tested specimens were different from those of main specimens. From the result, it is thought that coating resistance can be relatively more decreased than deterioration degree estimated from exterior view under more severe corrosion environment or in the present of more complex deterioration factors.

Using a Borehole Stability Device for Hydraulic Testing in Unconsolidated Alluvium (공벽 유지장치를 이용한 미고결 충적층의 수리특성 평가)

  • Won, Kyoung-Sik;Kim, Chunsoo;Chae, Soo-Yong;Shin, Dong-Min
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.15-22
    • /
    • 2016
  • Hydraulic falling head and slug tests were carried out in an alluvium aquifer using a borehole stability device. The hydraulic testing had proved difficult in alluvial formations of sands and gravels due to borehole collapse and unstable borehole walls within the test section. This study aims to improve the hydraulic test results by using a borehole stability device. The device can minimize the collapse of borehole walls, and the use of a filter with a constant opening ratio improves the calculations per unit area of the test section. Permeability obtained from the falling head test without a borehole stability device was 8.82 × 10−5m/sec. When the borehole stability device was installed in the same test section the measured permeability increased to 4.00 × 10−4m/sec, which is 4.5 times that obtained without the borehole device. The relatively low permeability obtained using the conventional test method is attributed to the presence of a fine-grained slime generated during drilling and a reduction of the test area in the test interval due to a gradual collapse of the borehole walls. This study considers how the use of a borehole stability device to prevent borehole collapse can influence the results of hydraulic tests in alluvial formations. It is expected that the results can be used as a basis for improving the reliability and applicability of hydraulic tests performed in alluvial aquifers.

Factors Associated with Decisions to Attend Cervical Cancer Screening among Women Aged 30-60 Years in Chatapadung Contracting Medical Unit, Thailand

  • Budkaew, Jiratha;Chumworathayi, Bandit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.12
    • /
    • pp.4903-4907
    • /
    • 2014
  • Background: This study aimed to identify factors associated with women's decisions to attend cervical cancer screening and to explore those linked with intention to attend in the coming year and to continue regular screening. Materials and Methods: A community based case-control study was conducted among woman 30-60 years of age in catchment area of Chatapadung Contracting Medical Unit (CCMU), networking of Khon Kaen Center Hospital, Thailand. Self-administered questionnaires were used to collect data, and in-depth interviews were then performed to explore in greater detail. Results: There were 195 participants. Only one third (32.3 %) had been screened for cervical cancer within the past 5 years. Some 67.7% reported that they had not been screened because they had no abnormal symptoms, single marital status, and no children. Only 10.6% of those never had screening intent to be screened within the next 12 months. High family income (adjusted OR=2.16, 95%CI=1.13-4.14), good attitude towards a Pap test (OR=1.87, 95%CI=1.09-4.23), and having received a recommendation from health care providers were important factors associated with decisions to attend cervical cancer screening (OR=1.73, 95%CI=1.01-4.63). From in-depth interviews, there were five reasons of their decisions to attend cervical cancer screening including yearly check-up, postpartum check-up, having abnormal symptom, encouragement by health care providers, and request from workplace. Conclusions: High family income, good attitude towards a Pap test, and receiving proper recommendation by health care providers, were important factors associated with decision to have cervical cancer screening among women 30-60 years old. Trying to enhance these factors and reduce barriers regarding screening, may increase the coverage rate for cervical cancer screening in Thailand.

Load Transfer Characteristics and Ultimate Bearing Capacity of PHC Pile in Deep Soft Clay Layer (대심도 연약지반에 근입된 PHC말뚝기초의 하중전이특성 및 극한지지력 산정)

  • Lee, Yonghwa;Kim, Myunghak
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.1
    • /
    • pp.41-46
    • /
    • 2008
  • In this study, the analysis of load transition of PHC pile was performed with the static load test, which was driven in deep soft clay layer of MyungJi site in the western area of Pusan. The results of test showed that the range of unit side resistance of pile in sand layer were $7.4t/m^2$ to $23.3t/m^2$ and $6.4t/m^2$ in the soft clay layer, while the unit base resistance was $955t/m^2$ in dense silty sand layer. To select the most reasonable static bearing capacity formular, the field measured values are compared with the calculated ones from the suggested various formular. In the case of side resistance in sand layer, the suggest formular in the Structural Foundation Design Manual by KGS was most reasonable, while in clay layer Railroad Design Manual.

  • PDF

Empirical Analysis on the Substitutability or Complementary Nature of Export and Import among Korea, China, and Japan (한-중-일 수출입의 대체·보완성에 관한 실증분석)

  • Rhee, Hyun-Jae
    • International Area Studies Review
    • /
    • v.15 no.3
    • /
    • pp.215-237
    • /
    • 2011
  • The paper is basically designed to reveal substitutability or complementary nature of export and import among Korea, China, and Japan by employing unit root test, cointegration technique, and vector error correction model(VECM). Empirical evidences are shown that the trading among these countries has been dominated by a complementary nature in the short run which enables it to promote trading in those countries. In the long run, however, the substitutability nature effects strongly to the trading among Korea, China, and Japan. To this end, it could be tentatively concluded that market-oriented trading policies are more effective to stimulate the export and import in those countries in the short run, while a trading policy has to be selectively implemented by the substitutability nature in the long run basis. For instance, a stability policy for exchange rates and various commercial policies could be set for a short term target. Whereas, the substitutability nature should be counted in building up a new industrial structure or in implementing FTA agreement among Korea, China, and Japan.

A Study on the Verification of an Indoor Test of a Portable Penetration Meter Using the Cone Penetration Test Method (자유낙하 콘관입시험법을 활용한 휴대용 다짐도 측정기의 실내시험을 통한 검증 연구)

  • Park, Geoun Hyun;Yang, An Seung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.2
    • /
    • pp.41-48
    • /
    • 2019
  • Soil compaction is one of the most important activities in the area of civil works, including road construction, airport construction, port construction and backfilling construction of structures. Soil compaction, particularly in road construction, can be categorized into subgrade compaction and roadbed compaction, and is significant work that when done poorly can serve as a factor causing poor construction due to a lack of compaction. Currently, there are many different types of compaction tests, and the plate bearing test and the unit weight of soil test based on the sand cone method are commonly used to measure the degree of compaction, but many other methods are under development as it is difficult to secure economic efficiency. For the purpose of this research, a portable penetration meter called the Free-Fall Penetration Test (FFPT) was developed and manufactured. In this study, a homogeneous sample was obtained from the construction site and soil was classified through a sieve analysis test in order to perform grain size analysis and a specific gravity test for an indoor test. The principle of FFPT is that the penetration needle installed at the tip of an object put into free fall using gravity is used to measure the depth of penetration into the road surface after subgrade or roadbed compaction has been completed; the degree of compaction is obtained through the unit weight of soil test according to the sand cone method and the relationship between the degree of compaction and the depth of the penetration needle is verified. The maximum allowable grain size of soil is 2.36 mm. For $A_1$ compaction, a trend line was developed using the result of the test performed from a drop height of 10 cm, and coefficient of determination of the trend line was $R^2=0.8677$, while for $D_2$ compaction, coefficient of determination of the trend line was $R^2=0.9815$ when testing at a drop height of 20 cm. Free fall test was carried out with the drop height adjusted from 10 cm to 50 cm at increments of 10 cm. This study intends to compare and analyze the correlation between the degree of compaction obtained from the unit weight of soil test based on the sand cone method and the depth of penetration of the penetration needle obtained from the FFPT meter. As such, it is expected that a portable penetration tester will make it easy to test the degree of compaction at many construction sites, and will lead to a reduction in time, equipment, and manpower which are the disadvantages of the current degree of compaction test, ultimately contributing to accurate and simple measurements of the degree of compaction as well as greater economic feasibility.