• Title/Summary/Keyword: Unit Power Factor

Search Result 252, Processing Time 0.026 seconds

A Study on PWM Converter of Auxiliary Power Block for Next Generation High Speed Train (차세대 고속전철용 보조전원장치용 PWM 컨버터에 대한 연구)

  • Jeong, Jeong-Han;Cha, Gil-Ro;Lee, Won-Cheol;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.245-248
    • /
    • 2008
  • This paper gives a description of the mode'ling and control of a single phase PWM(Pulse Width Modulation) converter for HEMU-400X(High-speed Electric Multiple Unit - 400 km/h experiment). The converter is part of a Auxiliary power unit supplied by the 25[kV], 60[Hz] overhead line. A model of the converter in a synchronously rotating reference frame of coordinates is used to develop a new type of control. The control system has separate controllers for the active and reactive current, permitting the free choice of the power factor. This paper proposes a new control method of PWM converter for Auxiliary power unit.

  • PDF

Reactive Current Control Method for Variable Source Voltage of AC-DC PWM Converter (무효전류 제어기법에 의한 전원전압 보상형 컨버어터의 구성에 관한 연구)

  • Kim, Byoung-Soo;Lee, Sang-Hun;Choi, Cheol;Kim, Cheul-U
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.6
    • /
    • pp.336-341
    • /
    • 1999
  • In this paper a control method to compensate the fluctuation in source voltage by using reactive current is presented. When the source voltage is changed within $\pm$10[%] range, the unit power factor is carried out. Otherwise, the converter is controlled by variable power factor. By using above control, the converter input voltage is maintained constantly. And then it was certified by simulation with the ACSL and several experiments.

  • PDF

Power Standard System for the Calibration and Test of Precision Power Meters (정밀전력계의 교정과 시험을 위한 전력표준시스템)

  • Park, Young-Tae;Ryu, Kwon-Sang;Yu, Kwang-Min;Jang, Seok-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.11
    • /
    • pp.622-627
    • /
    • 2002
  • The power comparison techniques have implemented power measurements, in which a power comparator is used to balance ac against a dc power obtained from known values. The developed power standard system using the comparison techniques consists of dc sources, ac source, control switches, resistive voltage dividers, resistive shunts and a power comparator. The total uncertainty of the power standard system was proved by analysis of the component instruments. Its expanded(k=2) uncertainty is evaluated to be less than 30 uW/VA at unit power factor and 42 uW/VA at power factor 0.5

A Study on Improvement of Strength Safety Factor for K55A1 APU Engine Mounts (자주포 보조동력장치 엔진 마운트 강도안전율 향상에 관한 연구)

  • Kim, Byung Hyun;Seo, Jae Hyun;Park, Young Il;Kim, Yong Wook;Kim, Byung Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.281-287
    • /
    • 2016
  • The purpose of this study is to analyze the vibration characteristics and develop a mounting which can improve the strength safety factor to replace the high failure rate APU(auxiliary power unit) imported metal mounts with rubber mount that can be domestically produced. For this study, we analyzed in 3 kinds of rubber mounts hardness for the natural frequency to avoid the average excited frequency of the APU. In addition, allowed vibration acceleration of rubber mount confirmed to 90.8 g by adding a strength safety factor. To assure the validity of the design, we measure the vibration acceleration equipped with a metal mount and rubber mount 2 species(Hs 50 and 60). As a result, the proposed design method in this study is reasonable because the rubber mounts is excellent strength safety factor and vibration transmissibility than metal mounts.

A Study on the Development of A Rectifier Unit for Telecommunication Equipments with Free Input-Voltage Regulations (Free Voltage Regulation기능을 갖는 교환기용정류기 개발에 관한 연구)

  • Kim, Eun-Soo;Joe, Kee-Yeon;Rim, Geun-Hie;Kim, Yo-Hee;Hong, Sung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.821-824
    • /
    • 1993
  • This paper deals with a $3{\phi}$ rectifier unit for telecommunication system. The rectifier unit is developed to Cope with the step-up of the AC input voltatage from 220V to 380V. By using a buck-type converter in the front-end, it keeps the input power factor high and reduces the voltage ripple in the dc output. It also has a very wide voltage regulation range, which lets the unit be applied for both the 220V and 380V input system. The study includes the power conversion scheme, control strategy, snubber circuit and finally, experimental results.

  • PDF

Fuel Cost Analysis of CANDU-PHWR Wolsung Nuclear Power Plant Unit 1

  • Lee, Ik-Hwan;Lee, Chang-Kun;Yang, Chang-Guk;Yook, Chong-Chul
    • Nuclear Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.151-163
    • /
    • 1977
  • Being based on the Segal method, calculation was carried out for the natural uranium nuclear fuel cost with Zircaloy-4 cladding having design Parameters of Wolsung Nuclear Power Plant, CANDU-PHWR (Unit 1) , currently under construction in Korea aiming at its completion in 1982. An attempt was also made for tile sensitivity analysis of each fuel component; j. e., depreciation of fuel manufacturing plant caused by its life time, its load factor, production scale expansion of plant facilities, variations of construction and operating costs of fuel manufacturing plant, fluctuation of interest rates, extent of uranium ore price increases and effect of learning factor.

  • PDF

A Study on The 4-Parallel Operation of PWM Converter for High Speed Train Auxiliary Block (고속전철 보조전원 장치용 PWM컨버터의 4병렬 운전에 관한 연구)

  • Oh, G.W.;Kim, Y.C.;Won, C.Y.;Choi, J.M.;Ki, S.W.;Bae, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1230-1232
    • /
    • 2000
  • To reduce harmonics in the AC line and achieve a unit power factor, A 4 paralled single phase PWM AC/DC converter has been proposed. In this paper, the coupling components are derived analytically from PWM converter input transformer model and control scheme to solve this problem is proposed. Unit power factor was obtained and the AC-side current harmonics were reduced. Simulation results show the usefulness of the proposed method and applicability to PWM converter in auxiliary block of high speed train.

  • PDF

The APF System to reduce both Voltage and Current Harmonics (전압 및 전류고조파 동시 저감을 위한 APF 시스템)

  • Shon, Jin-Geun;Kim, Byung-Jin;Na, Chae-Dong;Lee, Sung-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.46-48
    • /
    • 2003
  • A single phase voltage-controlled active power filter(APF) is introduced to improve power quality and to reduce harmonic generated from nolinear loads. Real and reactive power control scheme was addressed using a new power circuit model. By analyzing the reactive power, a unit power factor control scheme was proposed. Simulation and experiment results using a nonlinear diode rectifier showed that the voltage-controlled APF, unlike the current-controlled APF, can reduce the voltage harmonics as well as current harmonics. Also the results showed that the input power factor was greatly improved.

  • PDF

A control method and test results of utility interactive photovoltaic power generation systems (계통연계 태양광발전시스템의 제어기법 및 연계운전특성)

  • 안교상;임희천;황인호;주형준
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.549-553
    • /
    • 1999
  • This paper describes a design method of grid-connected photovoltaic power generation systems with three phase inverter. A 3-phase 50kW photovoltaic power generation system including a DC/AC inverter is designed and made in order to investigate the system performance for grid connection. Also the control scheme of a three phase current-controlled PWM inverter is presented by using d-q transformation. The experimental waveforms show that the proposed system has stable behavior with an unit power factor in utility-interactive operation.

  • PDF