• 제목/요약/키워드: Unit Power Factor

검색결과 252건 처리시간 0.03초

차세대 고속전철용 보조전원장치용 PWM 컨버터에 대한 연구 (A Study on PWM Converter of Auxiliary Power Block for Next Generation High Speed Train)

  • 정한정;차길로;이원철;원충연
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.245-248
    • /
    • 2008
  • This paper gives a description of the mode'ling and control of a single phase PWM(Pulse Width Modulation) converter for HEMU-400X(High-speed Electric Multiple Unit - 400 km/h experiment). The converter is part of a Auxiliary power unit supplied by the 25[kV], 60[Hz] overhead line. A model of the converter in a synchronously rotating reference frame of coordinates is used to develop a new type of control. The control system has separate controllers for the active and reactive current, permitting the free choice of the power factor. This paper proposes a new control method of PWM converter for Auxiliary power unit.

  • PDF

무효전류 제어기법에 의한 전원전압 보상형 컨버어터의 구성에 관한 연구 (Reactive Current Control Method for Variable Source Voltage of AC-DC PWM Converter)

  • 김병수;이상훈;최철;김철우
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권6호
    • /
    • pp.336-341
    • /
    • 1999
  • In this paper a control method to compensate the fluctuation in source voltage by using reactive current is presented. When the source voltage is changed within $\pm$10[%] range, the unit power factor is carried out. Otherwise, the converter is controlled by variable power factor. By using above control, the converter input voltage is maintained constantly. And then it was certified by simulation with the ACSL and several experiments.

  • PDF

정밀전력계의 교정과 시험을 위한 전력표준시스템 (Power Standard System for the Calibration and Test of Precision Power Meters)

  • 박영태;유권상;유광민;장석명
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권11호
    • /
    • pp.622-627
    • /
    • 2002
  • The power comparison techniques have implemented power measurements, in which a power comparator is used to balance ac against a dc power obtained from known values. The developed power standard system using the comparison techniques consists of dc sources, ac source, control switches, resistive voltage dividers, resistive shunts and a power comparator. The total uncertainty of the power standard system was proved by analysis of the component instruments. Its expanded(k=2) uncertainty is evaluated to be less than 30 uW/VA at unit power factor and 42 uW/VA at power factor 0.5

자주포 보조동력장치 엔진 마운트 강도안전율 향상에 관한 연구 (A Study on Improvement of Strength Safety Factor for K55A1 APU Engine Mounts)

  • 김병현;서재현;박영일;김용욱;김병호
    • 한국군사과학기술학회지
    • /
    • 제19권3호
    • /
    • pp.281-287
    • /
    • 2016
  • The purpose of this study is to analyze the vibration characteristics and develop a mounting which can improve the strength safety factor to replace the high failure rate APU(auxiliary power unit) imported metal mounts with rubber mount that can be domestically produced. For this study, we analyzed in 3 kinds of rubber mounts hardness for the natural frequency to avoid the average excited frequency of the APU. In addition, allowed vibration acceleration of rubber mount confirmed to 90.8 g by adding a strength safety factor. To assure the validity of the design, we measure the vibration acceleration equipped with a metal mount and rubber mount 2 species(Hs 50 and 60). As a result, the proposed design method in this study is reasonable because the rubber mounts is excellent strength safety factor and vibration transmissibility than metal mounts.

Free Voltage Regulation기능을 갖는 교환기용정류기 개발에 관한 연구 (A Study on the Development of A Rectifier Unit for Telecommunication Equipments with Free Input-Voltage Regulations)

  • 김은수;조기연;임근희;김요희;홍성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.821-824
    • /
    • 1993
  • This paper deals with a $3{\phi}$ rectifier unit for telecommunication system. The rectifier unit is developed to Cope with the step-up of the AC input voltatage from 220V to 380V. By using a buck-type converter in the front-end, it keeps the input power factor high and reduces the voltage ripple in the dc output. It also has a very wide voltage regulation range, which lets the unit be applied for both the 220V and 380V input system. The study includes the power conversion scheme, control strategy, snubber circuit and finally, experimental results.

  • PDF

Fuel Cost Analysis of CANDU-PHWR Wolsung Nuclear Power Plant Unit 1

  • Lee, Ik-Hwan;Lee, Chang-Kun;Yang, Chang-Guk;Yook, Chong-Chul
    • Nuclear Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.151-163
    • /
    • 1977
  • CANDU-PHWR형 원자로인 월성 1호기의 Zircaloy-4 피복 핵연료 설계치를 중심으로 Segel method에 의하며 FACOM 230 OS$_2$/VS 콤퓨터 시스템을 사용하여 핵연료비를 계산하였다. 아울러 핵연료 제조공장의 수덩, 가동을, 곧장시설 낑산규모 증대, 건설지 및 운전비기 변동, 이자율의 변화, 원광가격의 물가상승을, 기술개발인자 등이 핵연료비 계산에 미치는 효과에 패한 민감도를 분석하였다.

  • PDF

고속전철 보조전원 장치용 PWM컨버터의 4병렬 운전에 관한 연구 (A Study on The 4-Parallel Operation of PWM Converter for High Speed Train Auxiliary Block)

  • 오근우;김연충;원충연;최종묵;기상우;배기훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1230-1232
    • /
    • 2000
  • To reduce harmonics in the AC line and achieve a unit power factor, A 4 paralled single phase PWM AC/DC converter has been proposed. In this paper, the coupling components are derived analytically from PWM converter input transformer model and control scheme to solve this problem is proposed. Unit power factor was obtained and the AC-side current harmonics were reduced. Simulation results show the usefulness of the proposed method and applicability to PWM converter in auxiliary block of high speed train.

  • PDF

전압 및 전류고조파 동시 저감을 위한 APF 시스템 (The APF System to reduce both Voltage and Current Harmonics)

  • 손진근;김병진;나채동;이성범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.46-48
    • /
    • 2003
  • A single phase voltage-controlled active power filter(APF) is introduced to improve power quality and to reduce harmonic generated from nolinear loads. Real and reactive power control scheme was addressed using a new power circuit model. By analyzing the reactive power, a unit power factor control scheme was proposed. Simulation and experiment results using a nonlinear diode rectifier showed that the voltage-controlled APF, unlike the current-controlled APF, can reduce the voltage harmonics as well as current harmonics. Also the results showed that the input power factor was greatly improved.

  • PDF

계통연계 태양광발전시스템의 제어기법 및 연계운전특성 (A control method and test results of utility interactive photovoltaic power generation systems)

  • 안교상;임희천;황인호;주형준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.549-553
    • /
    • 1999
  • This paper describes a design method of grid-connected photovoltaic power generation systems with three phase inverter. A 3-phase 50kW photovoltaic power generation system including a DC/AC inverter is designed and made in order to investigate the system performance for grid connection. Also the control scheme of a three phase current-controlled PWM inverter is presented by using d-q transformation. The experimental waveforms show that the proposed system has stable behavior with an unit power factor in utility-interactive operation.

  • PDF