• Title/Summary/Keyword: Unit Loads

Search Result 425, Processing Time 0.027 seconds

Building Wind Corridor Network Using Roughness Length (거칠기길이를 이용한 바람통로 네트워크 구축)

  • An, Seung Man;Lee, Kyoo-Seock;Yi, Chaeyeon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.3
    • /
    • pp.101-113
    • /
    • 2015
  • The purpose of this study is increasing ventilation network usability for urban green space planning by enhancing its practicality and detail. A ventilation network feature extraction technique using roughness length($z_0$) was proposed. Continuously surfaced DZoMs generated from $z_0$(cadastral unit) using three interpolations(IDW, Spline, and Kriging) were compared to choose the most suitable interpolation method. Ventilation network features were extracted using the most suitable interpolation technique and studied with land cover and land surface temperature by spatial overlay comparison. Results show Kriging is most suitable for DZoM and feature extraction in comparison with IDW and Spline. Kriging based features are well fit to the land surface temperature(Landsat-7 ETM+) on summer and winter nights. Noteworthy is that the produced ventilation network appears to mitigate urban heat loads at night. The practical use of proposed ventilation network features are highly expected for urban green space planning, though strict validation and enhancement should follow. (1) $z_0$ enhancement, (2) additional ventilation network interpretation and editing, (3) linking disconnected ventilation network features, and (4) associated dataset enhancement with data integrity should technically preceded to enhance the applicability of a ventilation network for green space planning. The study domain will be expanded to the Seoul metropolitan area to apply the proposed ventilation network to green space planning practice.

A l0b 150 MSample/s 1.8V 123 mW CMOS A/D Converter (l0b 150 MSample/s 1.8V 123 mW CMOS 파이프라인 A/D 변환기)

  • Kim Se-Won;Park Jong-Bum;Lee Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.1
    • /
    • pp.53-60
    • /
    • 2004
  • This work describes a l0b 150 MSample/s CMOS pipelined A/D converter (ADC) based on advanced bootsuapping techniques for higher input bandwidth than a sampling rate. The proposed ADC adopts a typical multi-step pipelined architecture, employs the merged-capacitor switching technique which improves sampling rate and resolution reducing by $50\%$ the number of unit capacitors used in the multiplying digital-to-analog converter. On-chip current and voltage references for high-speed driving capability of R & C loads and on-chip decimator circuits for high-speed testability are implemented with on-chip decoupling capacitors. The proposed AU is fabricated in a 0.18 um 1P6M CMOS technology. The measured differential and integral nonlinearities are within $-0.56{\~}+0.69$ LSB and $-1.50{\~}+0.68$ LSB, respectively. The prototype ADC shows the signal-to-noise-and-distortion ratio (SNDR) of 52 dB at 150 MSample/s. The active chip area is 2.2 mm2 (= 1.4 mm ${\times}$ 1.6 mm) and the chip consumes 123 mW at 150 MSample/s.

Fatigue Analysis of External Fuel Tank and Pylon for Fixed Wing Aircraft (고정익항공기용 외부연료탱크 및 파일런 피로 해석)

  • Kim, Hyun-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.162-167
    • /
    • 2020
  • In this study, a fatigue analysis of an external fuel tank and pylon for fixed-wing aircraft was carried out as part of the domestic development of fixed-wing aircraft. Through structural analysis, the analysis areas were selected, and the transfer function for unit loads was established in the selected parts. For each of the continuous load profiles, stress components in the selected areas were calculated using the load of each profile and the transfer function, and the Von Mises equivalent stress was employed as the representative stress of each profile. In addition, the rainflow counting technique was used to extract individual profiles obtained from the initial large load profiles and to calculate their amplitude and average values. For life evaluation, the S-N diagram of the Metallic Materials Properties Development and Standardization (MMPDS) was applied, and the damage value was calculated by Miner's rule to assess the life of the selected area. As a result of the life assessment, the life span requirement for the selected area of the external fuel tank and the pylon was assessed as being satisfied.

Development of 3D Radiation Position Identification System of Multiple Radiation Sources using Plastic Scintillator and NaI(TI) Detector (플라스틱 Scintillator와 NaI(TI) 검출기를 이용한 다수의 방사선원 위치를 3차원으로 판별하는 측정시스템 개발)

  • Kwak, Dong-Hoon;Ko, Tae-Young;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.638-644
    • /
    • 2018
  • In this paper, we develop a measurement system that uses 3D Scintillator and NaI(TI) Detector to 3-dimensionally identify the location of multiple radiation sources in moving vehicle loads. The radiation measurement system consists of radiation measurement (plastic scintillator), 2-channel Pulse Counter Board, nuclide analysis (NaI(TI) detector) and 1 channel MCA Board. The source locator algorithm calculates the coordinate value of the ratio of the CPS value($1/r^2$) of the source according to the angle(${\theta}$) in inverse proportion to the square of the distance(X, Y) through the SVM classification. The coordinate values are input every predetermined period of the spectrum, and after analyzing the spectrum per unit cycle, the position of the nuclide at the time is calculated by determining whether or not the nuclide is present in the remaining part except for the background area. As a result of the position discrimination test, the error within the international standard of ${\pm}1m$ was shown. Thus, the utility of the proposed system has been demonstrated.

A PHOTOELASTIC STUDY OF THE STRESS DISTRIBUTION IN THE SURROUNDING TISSUES OF THE FIXED PARTIAL DENTURE WITH INTERMEDIATE ABUTMENT (중간지대치가 포함된 고정가공의치의 지대치 주위조직에서 발생하는 응력에 관한 광탄성학적 연구)

  • Jo, Kwang-Hyun;Choi, Boo-Byung;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.55-69
    • /
    • 1987
  • The purpose of this study was to evaluate the stress distributions of the fixed partial denture with five unit intermediate abutment. This fixed partial denture was attached to a three dimensional photoelastic epoxy resin model. Three dimensional photoelastic models were used, with the stress areas recorded photographically. A vertical load was applied to the second molar, which is the most posterior abutment of the fixed partial denture. Similarly, a vertical load was applied to the first molar because this tooth receives the heaviest masticatory load. These loads were added to two types of fixed partial denture. the rigid connector, and the nonrigid connector which was connected on the distal side of the intermediate abutment by a key and keyway device. After the stress patterns in surrounding tissues were observed, the following conclusions were as follows: 1. When the vertical load was applied to the first and second molars on the occlusal surfaces, the surrounding tissues of the roots of the canine, the second premolar, and the second molar were all compressive stresses. 2. When the vertical load was applied on the occlusal surface of the second molar, the tissue surrounding the roots of the canine, the second premolar, and the second molar all showed more stresses with the nonrigid connector than with the rigid connector. 3. When the vertical load was applied to the occlusal surface of the first molar, the stress concentration on the canine and the second molar was similar, whether the rigid or nonrigic connectors were used. However, on the second premolar, the stress concentration shown by the nonrigid connector was noticeably more than that shown by the rigid connector. 4. Whether the rigid or nonrigid connectors were used, when the load was placed on the first molar, the stress concentration on the canine and the second premolar was greater than that observed for the second molar. When the load was placed on the second molar, the load affected the second molar more than the canine and the second premolar.

  • PDF

Development of Tacho Generator for Application of Anti-aircraft Weapon System (대공무기체계 적용을 위한 타코제너레이터 개발)

  • Byun, Kisik;Park, Jun Young;Cho, Sung-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.174-180
    • /
    • 2020
  • This paper presents the development of a tacho generator that is applicable to a DC motor for anti-aircraft weapon systems. In general, devices such as tacho generators and resolvers are used as feedback devices for controlling DC motors. A tacho generator with a wide operating temperature range was developed, which has robust characteristics against shock loads and vibrations according to the operational characteristics of anti-aircraft weapon systems. The target specifications were set based on the requirements of the tacho generator currently in operation. A rotor coupled to the shaft of the motor and a stator coupled to the housing of the motor were then designed and manufactured. The inductance was 31.0 mH, the terminal resistance was 147.7 ohms, and the rotational measurement factor was satisfactory under both normal operation and operating conditions after the maximum speed for the standard of 9.500 ± 0.475 V/krpm. In addition, the environmental suitability of the applied equipment was confirmed through the rate of change in unit temperature, and it was found that the temperature characteristics were all within 0.03 %/℃.

A Study on the Ultimate Point Resistance of Rock Socketed Drilled Shafts Using FLAC3D and UDEC (유한차분해석과 개별요소해석을 이용한 암반에 근입된 현장타설말뚝의 선단지지력 연구)

  • Lee, Jae-Hwan;Cho, Hoo-Yeon;You, Kwang-Ho;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.1
    • /
    • pp.29-39
    • /
    • 2012
  • The maximum unit point resistance ($q_{max}$) of rock socketed drilled shafts subjected to axial loads was investigated by a numerical analysis. A 3D Finite Difference Method (FDM) analysis and a Distinct Element Method (DEM) analysis were performed with varying rock elastic modulus (E), discontinuity spacing ($S_j$), discontinuity dip angle ($i_j$), and pile diameter (D). Based on the results of obtained, it was found that the ultimate point resistance ($q_{max}$) increased as rock elastic modulus (E) and rock discontinuity spacing ($S_j$) increased. But, it was found that $q_{max}$ decreased as pile diameter (D) increased. As for the influence of the dip angle of rock discontinuity ($i_j$), it was shown that $q_{max}$ decreased up to 50% of maximum value within the range of $0^{\circ}$ < $i_j$ < $60^{\circ}$ due to the shear failure at rock discontinuities. Furthermore, it was found that if $20^{\circ}{\leq}i_j{\leq}40^{\circ}$, influence of $i_j$ should be taken into account because $q_{max}$ tended to approach a minimum value as $i_j$ approached a value near the friction angle of the discontinuity (${\phi}_j$).

Nutrient Balance in the Paddy Fields Watershed with a Source of River Water (하천관개지역 광역논에서의 영양물질의 물질수지)

  • Lee, Jeong Beom;Lee, Jae Yong;Li, Si Hong;Jang, Jeong Ryeol;Jang, Ik Geun;Kim, Jin Soo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.5
    • /
    • pp.11-19
    • /
    • 2014
  • The objective of this research was to investigate concentration and load of nutrients such as total nitrogen (TN), nitrate nitrogen ($NO_3$-N) total phosphorous (TP), and phosphate phosphorous ($PO_4$-P) in a 23.4-ha paddy fields watershed with river water source. Water samples for irrigation water, drainage water, ponded water and groundwater were collected, and irrigation and drainage water were measured at 5~10 day intervals during normal days and at 2~6 hours intervals during three storm events. The amount of irrigation water in the study area was over 2,000 mm, which is almost identical to that in the area irrigated from a large reservoir but much more than that in the area irrigated from a pumping station. Mean flow-weighted concentrations of TN and TP in irrigation water were 2.8 and 0.15 mg/L, respectively, higher than those in the area irrigated from a large reservoir or a pumping station. The ratios of irrigation load to total inflow load for TN and TP were 88 %, and the ratios of surface outflow load to total outflow load for TN and TP were over 90 %, indicating that total nutrient load may be greatly affected by water management. The nutrient loads per area in the study area were estimated as TN 21.1 kg/ha and TP 1.1 kg/ha. Especially, the TP load per area in the study area was smaller than that in the area irrigated from a large reservoir or a pumping station. This may be because outflow load is not high likely due to sedimentation of particulate P and irrigation water load is high due to high TP concentration in irrigation water and high amount of irrigation water.

Object-oriented Design for Water Quality Monitoring Networks in the Han River System (한강수계 수질측정망 개선을 위한 목적 지향 설계 방안에 관한 연구)

  • Wang, Soo-Kyun;Na, Eun-Hye;Park, Seok-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.5
    • /
    • pp.453-460
    • /
    • 2005
  • Since late 1970s, water quality monitoring had been performed in Korea by various agencies according to their own needs and objectives. Lacking of consistency in principles, such diverse operation has been producing difficulties in management of information on water quality parameters. These difficulties resulted from the fact that the expansion of monitoring networks had been based not on systematic methodology with considerations on scientifically established planning objectives but on personal experiences and subjective judgments in locating monitoring stations. This study aimed, therefore, to develop a selection methodology for locating monitoring stations to provide various informations on water quality to satisfy various monitoring objectives such as understanding short and long term trends of water quality, monitoring violations to water quality standards, identifying external causes and sources affecting water quality changes, supporting utilization of water resources, examining short-term variations in water quality through a concentrated investigation, estimating pollution loads from each unit watershed, supporting water quality modeling, and establishing informative systems for water resources management. Also, we applied the proposed methodology and presented an improved expansion plan for water quality monitoring networks in the Han River.

Analysis of the Implementation Effect of Total Water Load Management System Using Load Duration Curves in Sapgyo Watershed (부하지속곡선을 이용한 삽교천 유역의 오염총량관리제도 시행효과 분석)

  • Lee, Eunjeong;Kim, Taegeun
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.6
    • /
    • pp.536-548
    • /
    • 2019
  • In order to quantify the effect of the newly established the Total Water Load Management System in Sapgyo watershed, this study predicted the achievement of the target water quality at each unit watershed and the water quality according to the flow section. The HSPF model, which is the watershed runoff model, was constructed and operated based on 2015, and the water quality was predicted by inputting the loads in final target year(2030). The Load Duration Curve (LDC) was created using the simulated results of base year and target year. As a result of plotting water quality by flow conditions, it was simulated to be close to the BOD target with a difference of 0.1 ~ 0.2 mg/L in all three watersheds during the mid-range flow interval (40 ~ 60%). In case of T-P, although the target water quality was not set, the water quality was improved by Cheonan A 46%, Kokgyo A 29% and Namwon A 25%. The Muhan and Sapgyo river basins meet the target grade of middle-watershed standards. The improvement effect will be positive, as water quality, which achieves the target of Total Load Management System and the target grade of the middle-watershed standards will be expected to flow into the Sapgyo lake.