• Title/Summary/Keyword: Unit Factors

Search Result 2,395, Processing Time 0.067 seconds

Targeting Risk Factors for the Control of Central Line-Associated Bloodstream Infection in the Neonatal Intensive Care Unit: A Single Tertiary Center Experience

  • Jeong, Jiyoon;Kwun, Yoojin;Kim, Min-ju;Choi, Sang-Ho;Jung, Euiseok;Lee, Byong Sop;Kim, Ki-Soo;Kim, Ellen Ai-Rhan
    • Neonatal Medicine
    • /
    • v.28 no.3
    • /
    • pp.116-123
    • /
    • 2021
  • Purpose: The aim of this study was to estimate the effect of targeting risk factors for the control of central line-associated bloodstream infection (CLABSI) among high-risk infants in a tertiary neonatal intensive care unit (NICU). Methods: Infants admitted to the NICU and diagnosed with CLABSI from January to December 2013 were eligible for inclusion to the study. The CLABSI group (n=47) was matched in a 1:2 ratio to the control group (n=94) based on gestational age, birth weight, and Score for Neonatal Acute Physiology-II. Risk factors for CLABSI were identified using the Cox proportional hazard model, and analysis of the effect of these risk factors targeting infection control was performed. Results: The risk factors associated with CLABSI were prolonged central line dwell days (adjusted hazard ratio [HR], 1.028; 95% confidence interval [CI], 1.011 to 1.045; P=0.001), use of a silicone catheter (adjusted HR, 5.895; 95% CI, 1.893 to 18.355; P=0.002), surgical treatment (adjusted HR, 3.793; 95% CI, 1.467 to 9.805; P=0.006), and less probiotic supplementation (adjusted HR, 0.254; 95% CI, 0.068 to 0.949; P=0.042). By targeting these risk factors with a quality improvement initiative, the mean CLABSI incidence rate per 1,000 catheter-days decreased from 6.6 to 3.1 (P=0.004). Conclusion: Targeting risk factors for infection control significantly reduced the rate of CLABSI among high-risk infants in the NICU.

Factors Related with Residential Satisfaction of Urban Villages in Shenzhen, China (중국 심천시 어번 빌리지 주거만족도에 관련된 요소)

  • Zhang, Gui-Xian;Lee, Yeun-Sook;Lee, Soo-Jin
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.19-26
    • /
    • 2012
  • Residential satisfaction is one of the most studied topics in the field of housing. This paper is to find factors that correlate with residential satisfaction of the residents and study the satisfaction differences between different groups of residents in urban village in Shenzhen. A questionnaire of 61 satisfaction variables grouped into five components based on literature review and actual situation in targeted village was conducted to find out factors related with residential satisfaction in urban villages. These components are dwelling unit, building conditions, village environment, neighborhood environment, and neighbors. Factors were extracted from these components and the correlations between the factors and residential satisfaction were analyzed by using Pearson's correlation coefficient to find out factors that most correlate to residential satisfaction. Satisfaction differences of the five components between respondents with different characteristics were also studied. The result showed all the factors positively correlated with residential satisfaction and residential satisfaction correlated the most with the factors of perception and information exchange, room sizes, and air condition and quality. The characteristics of gender, unit type, and interaction frequency with neighbors contributed to different satisfaction with certain components.

A Study on the Preference for the Way of Composing the Unit Plan for Apartment Houses by Lifestyle (라이프스타일에 따른 공동주택 단위평면 공간구성방식에 관한 선호도 조사.연구)

  • Jun, Su-Young;Park, Seung-Hwan;Kim, Sung-Hwa;Choi, Moo-Hyuck
    • Journal of the Korean housing association
    • /
    • v.17 no.5
    • /
    • pp.147-157
    • /
    • 2006
  • A study on Composing Unit Spaces of Apartment Houses according to the Differentiation in Lifestyle by survey on preferences. The purpose of this study is to propose composition models of unit spaces for 85m2 net area apartment houses by lifestyle types. This study set up a hypothesis that there is a critical divergence of preferences in composition types of unit spaces according to lifestyle. To prove the hypothesis, investigation on variable floor plans of apartments to extract spatial composition types of units and questionnaire survey on lifestyleand preferences for composition types were implemented. To extract several factors regarding, characteristics of lifestyle, factor analysis, was implemented for each variable. Cluster analysis was conducted to cluster interviewees by similarity of lifestyle. To identify and define how each factor reacts, ANOVA and cross tabulation analysis between factors and clusters were used. The type of spatial composition was analyzed by plane characteristic, spatial relation and spatial usability on the basis of apartment plate type. As a result, lifestyle was divided into three types: reasonable lifestyle, trend-seeking lifestyle and conservative lifestyle. As, the result of investigating characteristics for the type of spatial composition according to the type of lifestyle, preferred types and main districts were different. Therefore, the hypothesis was proved.

A Study on exposure-Worker to Formaldehyde in the Endoscopy Unit of Hospitals (일부 종합병원 내시경실 근무자의 포름알데히드 노출에 관한 연구)

  • Kim, Jeong Hun;Kim, Dae-Jong;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.195-201
    • /
    • 2009
  • To identify relationship between the airborne concentrations of formaldehyde and the causal factors in the endoscope unit of hospitals, a total of 48 workers selected from 4 hospitals (3 university hospitals and 1 national hospital) were investigated. Airborne formaldehyde samples were collected using passive samplers and subsequently analyzed by HPLC according to the OSHA method 1007. The geometric mean(GM) of airborne formaldehyde concentrations was 0.056 ppm (range: 0.003~0.923 ppm). The rates of exceeding exposure limits of OSHA PEL-TWA and NIOSH REL-TWA were 4.2 % and 83.3%, respectively. The STEL GM concentration was 1.428 ppm(range: 0.103~14.773 ppm). Ventilation condition (p=0.001) and temperature (p=0.017) were statistically significant causal factors for the airborne exposure concentration of formaldehyde in the endoscope unit of hospitals. In conclusion, the workers in the endoscope unit of hospitals were highly exposed to formaldehyde, and adequate controls such as appropriate management of ventilation and temperature are recommended to reduce over exposure to formaldehyde.

A Study on Expressive Methods and Application of Aesthetics Factors for Design of Hosing Space with the Differentiation (주거공간의 차별화된 디자인을 위한 심미적요소의 표현방법 및 적용에 관한 연구)

  • Seo, Ji-Eun;Jeong, Ji-Seok
    • Journal of the Korean housing association
    • /
    • v.20 no.2
    • /
    • pp.101-108
    • /
    • 2009
  • The purpose of this study is to develop basic data for the design of the housing space for unit that factors in the sentiment of the residents by using aesthetic elements and expression method to search for the ways to design housing space for differentiated unit. The results are as follows: First, aesthetic elements in the aesthetic element in the unit housing space for unit can be classified into basic elements and detailed elements. Second, it is possible to classify into distortion, mixing, superposition and juxtaposition methods. Third, use of the 'material' for 'wall' is recommended when designing differentiated housing space by using basic elements. At this time, expression using the method of 'mixing' is effective for inducing differentiation. In particular, elements that can perceive the difference in time are mixed, to add on slight differentiation. Fourth, 'illumination' and 'material' are used when designing differentiated housing space by using detailed elements. Fifth, preference degree of the expression method is manifested differently depending on the selected elements. Lastly, this study conducted a study on the preference level of the aesthetic elements and expression method targeting the experts alone to differentiate the design of the residential space for unit.

A Study on the Evaluation of Thermal Environment according to the Location of Ceiling Type Unit in Classroom (교실 천장형 Unit의 위치에 따른 온열환경 평가 연구)

  • Cho, Sung-Woo;Choi, Jeong-Min;Son, Young-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.135-140
    • /
    • 2005
  • Installation of ceiling type unit is achieved by one of efforts for agreeable classroom environment embodiment along with economic growth. But research about changing the position of ceiling type unit is lacking in present. Therefore, this thesis is to study the thermal environment of 5 different position cases of ceiling type, namely Case A, B, C, D, E. Here, Case C is the case that has the position of ceiling type center of the classroom and the other 4 alternatives are 0.7 m away from the Case C according to x and z axis. In this thesis temperature distributions, air current distribution, heat amenities such as PMV of occupants are analyzed as the environmental factors. Through these factors, Case C and Case D are the better position alternatives than the alternatives of Case A, Case B and Case E because the latter cases the air current reaches directly to indoor occupants so that occupants feel chilly. This thesis has a conclusion under the condition of only one inlet air temperature and seat arrangement. But afterwards more inlet air condition and seat arrangement must be considered.

  • PDF

A predictive nomogram-based model for lower extremity compartment syndrome after trauma in the United States: a retrospective case-control study

  • Blake Callahan;Darwin Ang;Huazhi Liu
    • Journal of Trauma and Injury
    • /
    • v.37 no.2
    • /
    • pp.124-131
    • /
    • 2024
  • Purpose: The aim of this study was to utilize the American College of Surgeons Trauma Quality Improvement Program (TQIP) database to identify risk factors associated with developing acute compartment syndrome (ACS) following lower extremity fractures. Specifically, a nomogram of variables was constructed in order to propose a risk calculator for ACS following lower extremity trauma. Methods: A large retrospective case-control study was conducted using the TQIP database to identify risk factors associated with developing ACS following lower extremity fractures. Multivariable regression was used to identify significant risk factors and subsequently, these variables were implemented in a nomogram to develop a predictive model for developing ACS. Results: Novel risk factors identified include venous thromboembolism prophylaxis type particularly unfractionated heparin (odds ratio [OR], 2.67; 95% confidence interval [CI], 2.33-3.05; P<0.001), blood product transfusions (blood per unit: OR 1.13 [95% CI, 1.09-1.18], P<0.001; platelets per unit: OR 1.16 [95% CI, 1.09-1.24], P<0.001; cryoprecipitate per unit: OR 1.13 [95% CI, 1.04-1.22], P=0.003). Conclusions: This study provides evidence to believe that heparin use and blood product transfusions may be additional risk factors to evaluate when considering methods of risk stratification of lower extremity ACS. We propose a risk calculator using previously elucidated risk factors, as well as the risk factors demonstrated in this study. Our nomogram-based risk calculator is a tool that will aid in screening for high-risk patients for ACS and help in clinical decision-making.

Estimation of water unit factor and water demand of domestic airports (공항용수 원단위 산정 및 용수 사용량 추정방법)

  • Kim, Taeyoung;Kim, Taehwan;Huh, Dong;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.2
    • /
    • pp.231-239
    • /
    • 2009
  • The purpose of this research is to provide more reliable water unit factors of domestic airports by investigating of general informations related to the domestic airport. The informations of domestic airports such as passengers, settled population of airports, building areas and water amount are investigated to estimate the unit factor of water of domestic airports. The domestic airports are divided into three type such as central airport, position airport and general airport. Through analysis of relationship between water amount and the others, the unit factor of water could be calculated. The water amount of central airport as Incheon international airport and position airports could be estimated by unit factor of settled population. The others could be estimated by unit factor of building area.

Load Distribution Factors for Hollow Core Slabs with In-situ Reinforced Concrete Joints

  • Song, Jong-Young;Kim S, Elliott;Lee, Ho;Kwak, Hyo-Gyoung
    • International Journal of Concrete Structures and Materials
    • /
    • v.3 no.1
    • /
    • pp.63-69
    • /
    • 2009
  • This paper provides the engineer with a simple design method dealing with situations arise where in-situ reinforced concrete joints are cast between hollow core units. Using finite element method, hollow core slabs with wide in-situ RC joints under point load and line loads are analysed. In addition, some important behavioural characteristics of the floor slab subjected to line and point loads are investigated. In-situ reinforced concrete joint causes reduction of load distribution for remote units because distance to the remote units from the point of load is increased, while the portion of load distribution carried by loaded unit increases. Also, it was turned out load distribution factors for point load and line loads are almost same. Finally, we suggest a simple analytical method, which can determine load distribution factors using normalized deflections by regression analysis for design purposes.

A Study on Annual Atmospheric Dispersion Factors Between Continuous and Purge Releases of Gaseous Radioactive Effluents

  • Kim, Na-Hyun;Hwang, Won-Tae;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.2
    • /
    • pp.177-186
    • /
    • 2021
  • Radioactive materials from nuclear power facilities can be released into the atmosphere through various channels. Recently, the dispersion of radioactive materials has become critical issue in Korea after Kori Unit 1 and Wolsong Unit 1 were permanently shut down. In this study, annual atmospheric dispersion factors were compared based on the continuous release and purge release using the XOQDOQ computer program, a method for calculating atmospheric dispersion factors at commercial nuclear power stations. The meteorological data analyzed in this study was based on the Shin Kori nuclear power meteorological tower which has the largest operating nuclear power plants in Korea, for three years (from 2008 to 2010). The analysis results of the dispersion factor of the radioactive material release obtained using the XOQDOQ program showed that the difference between the continuous release and purge release was within two times. This study will be valuable helpful for revealing the uncertainty of the predictive atmospheric dispersion factor to achieve regulation.