• Title/Summary/Keyword: Uniformity ratio of illumination

Search Result 20, Processing Time 0.038 seconds

Hybrid Illumination System Design based on Illuminance Uniformity for Surface Inspection (표면 검사를 위한 조도 균제도 기반 하이브리드 조명계 설계)

  • Cho, Eun Deok;Kim, Gyung Bum
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.3
    • /
    • pp.60-65
    • /
    • 2019
  • In this paper, the hybrid illumination system for effectively detecting surface defects in steel plate with lowcontrast, non-uniformity and featureless is designed based on illuminance uniformity. First of all, characteristics of steel plate defects were considered and typical inspection illumination system is implemented. Optimum illumination parameters for uniformly illuminating an inspection area in the typical illumination system are selected based on the illuminance uniformity and illuminance distribution measurement. The illuminance uniformity and illuminance distribution are measured using an illuminometer based on the arduino. Through illuminance distribution analysis of the typical illumination, an hybrid illumination is designed by fusing bi-directional illumination and coaxial illumination. The hybrid illumination showed higher uniformity ratio and illuminance distribution than the typical illuminations. The hybrid illumination system showed the ability to uniformly illuminate the entire inspection region of steel plate surface.

A Study of yield method including artificial lighting uniformity ration in interior space (실내공간에서의 인공조면 균제도 산출방법에 대한 일고찰)

  • ;金玹志
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.139-139
    • /
    • 1999
  • In this paper, the result of study in artificial lighting uniformity ratio yield method subject to lecture room are reported. It is desirable that the application of equation ① U=Ei/Ex×100 cannot be used to the mean value in place to be effective of light and darkness. And it is desirable that the application of equation ② U=Ei/Ea×100 or equation ③ U=(Ea-Ei)/Ea×100 be used to the mean Value equality illumination conditions. Also, requiring preparation of judgement standard, uniformity ratio equation agree with actual circumstances in this country. It must be considered intensity of illumination and specificity of space in established standard.

A Study of yield method including artificial lighting uniformity ration in interior space (실내공간에서의 인공조면 균제도 산출방법에 대한 일고찰)

  • 김현지;안옥희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.7-11
    • /
    • 1999
  • In this paper, the result of study in artificial lighting uniformity ratio yield Irethod subjtrt to lecture room are reported. It is desirable that the aWication of equation $\circled1 U=Ei/Ex\times100$ cannot be used to the rrean value in place to be efftrtive of light and darkness. And it is desirable that the awlication of equatioo $\circled2 U=Ei/Ea\times100$ or equation $\circled3 U=(Ea-Ei)/Ea\times100$ be used to the rrean Value equality illumination conditioos. Also, requiring preparation of judgarent standard, uniformity ratio equation agree with actual circumstances in this country. It must be considerai intensity of illumination and specificity of space in established standard.andard.

  • PDF

Economical Efficient Evaluation of Lighting Design in Lecture Room (강의실 조명설계의 경제성 평가)

  • Kim, Deog-Goo;Oh, Seong-Bo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.268-273
    • /
    • 2004
  • The visual environment in an educational building, apart from providing the comfortable seeing conditions needed for the performance of a wide variety of work tasks, must also satisfy the psychological and emotional needs of learners. This paper presents study on actual illumination environment of college and comparison of economical efficiency in order to figure out illumination problems. Furthermore, it attempts to suggest an optimum design of lecture room illumination through computer simulation. We try to evaluate economical efficiency of lighting design in lecture room under the illumination plan which is based on illumination maintenance and uniformity ratio that KS. illumination standard sets.

  • PDF

Lighting Analysis and Modeling on Jokcu Court (족구장 조명설비에 대한 해석 및 모델링)

  • Kim, Deog-Goo;Oh, Seong-Bo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.173-177
    • /
    • 2007
  • This paper describes the simulations on the actual measurement analysis and lighting design for recreational sports facility. Based on illumination requirements, sports may be divided into multidirectional sports and unidirectional sports. Typical multidirectional aerial sports include Jokcu. These sports require well distributed horizontal illumination and uniformity according to aiming. Therefore, this paper estimates horizontal illuminance and uniformity ratio by actual measurement of sports lighting at recreational Jokcu court in Cheju National University and evaluation of sports lighting conditions for optimal design by computer simulation.

  • PDF

A Study on the Actual Conditions of Living Room Lighting in Daegu and Gyeongbuk Districts (대구·경북 지역 거실 조명 실태조사)

  • Jo, Young-Mi;An, Ok-Hee;Kim, Hyun-Jin
    • Journal of the Korean housing association
    • /
    • v.23 no.3
    • /
    • pp.13-20
    • /
    • 2012
  • This research study was conducted to determine the actual conditions of living room lighting in Daegu and Gyeongbuk districts. For this study, 112 households were surveyed. The results of this study are as follows: Firstly, fluorescent light was used as the general illumination of living rooms, and the ratio of not using local sources of illumination was high. Secondly, the standard illuminance was found to be 221. The illuminance was the value that satisfied the activities for togetherness and entertainment, but did not reach the illuminance necessary for other activities, such as reading, make-up, and sewing. In addition, the uniformity of brightness used as a measure of uniformity in examining the results was normal. Thirdly, both the brightness and the satisfaction of lighting in the living room space were indicated to be normal. In addition, in regard to housing lighting, 'stability', and 'brightness of lighting' were indicated as important considerations and 'brightness of lighting', 'shadow' and 'management of lighting' were indicated as problem areas.

Development of Optical System for 50W LED Security Lamp (50W급 LED 보안등용 조명광학계 개발)

  • Jung, Byoung-Jo;Jang, Sung-Whan;Roh, Yong-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.296-305
    • /
    • 2012
  • In this paper, we develop about glare phenomenon at security light caused by light source's straight characteristic, maintaining uniformity ratio of illuminance as high, have long light distribution not by symmetry of rotation but a single axis. we develop second lens for security light that lack of light distribution phenomenon at each of security light can be solved. Our developed light system design satisfies lighting standard of security light's and shape of lens is single lens. so our lens optimizes designing or analysis by using lighting design and interpretation program. Making a Mock-up to do real measure, we have intensity of illumination and maintaining uniformity ratio of illuminance measurement data.

Actual Conditions on the Illumination Environment of the Study Rooms in the Youth of an Agriculture Village (농촌 청소년 공부방의 조명환경 실태조사)

  • Kim, Hyun-Ji;Jun, Kyoung-Sun;Lee, In-Hyo;An, Ok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.1-7
    • /
    • 2009
  • This study investigated the actual conditions of the illumination environment from agricultural youth study room. The result, average space of the study room was 11.42[$m^2$]. The illuminant uses the fluorescent lamp mainly, Method of using illumination was only general illumination the case which uses 73.8[%]. Method of light distribution was a direct lighting mainly. The house which has a stand illumination was also 45.7[%], The percentage using the stand illumination which was a local illumination was nothing but in 20[%] of the whole subject of investigation, therefore eye work could not effective. The internal illuminance was average 131.82[lx], the desk illuminance was 253.64[lx] which was the minimum permitted limit and poor. Uniformity ratio of illuminance appeared with average 35.61[%]. The satisfaction with 3.93 points to be high for illumination environment, therefore it was thought that the recognition of illumination was very insufficient.

Comparison on the lighting environment of living room between China and Korea : Comparative study on the lighting environment of houses in Korea and China 1

  • Kim, Hyun-Ji;Jia, Hao;An, Ok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.11
    • /
    • pp.1-8
    • /
    • 2009
  • To compare the lighting environment of the living rooms in the apartments in Korea and China, this research conducted a study of the current status, targeting 79 households in Korea and 68 households in China. The results are the following. First, the two nations use mostly fluorescent light as the general lighting for the living room. China, in particular, share of not using the local lighting is very high. Secondly, levels of illumination was measured. The result demonstrates that the brightness of the lighting is higher in Korea compared to China while China demonstrates higher uniformity ratio for the levels of illumination compared to Korea. However, levels of illumination in general are very low in China. Thus, it cannot be concluded that China offers favorable lighting environment. Third, study on the degree of living room lighting's brightness and satisfaction level demonstrates that they are both average in Korea and China. As for the important points for the house lighting, most Koreans cited 'brightness of the lighting' while most Chinese said 'ease of maneuvering'.

Reflector Design for LED Pedestrian Lighting Using Indirect Reflectance Type (간접 반사 방식의 LED 보안등기구 반사판 설계)

  • Chae, Sung-Gi;Jung, Dong-Hwan;Lee, Yoon-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.6-13
    • /
    • 2012
  • In this paper, we took an indirect reflectance type that irradiates light from an LED module, which reflects light from a reflector onto the road. This LED pedestrian lighting design produces minimal glare from a relatively simple structure. Using LightTools 7.2, we conducted a study on the varying shape and curvature of the reflector. In order to further investigate this data, we researched the ratio of the DLOR and ULOR, the average illuminance, and the uniformity of the illumination. Based on this research, we selected optimum conditions to realize the actual LED pedestrian lighting using RELUX software. We found the average illuminance value to be 22[1x] and the illuminance uniformity ratio to be 0.23, which met the criteria of the proposed standards set in KS C 7658. In addition, it also satisfied the criteria of the standards set in KS A 3701 by having TI (Threshold Increment) at 7[%].