Development of a Grain Circulating Type Natural Air In-bin Dryer (I) - Development of dryer and analysis of drying performance (곡물 순환식의 상온통풍 건조기 개발(I) - 건조기 개발 및 벼의 건조성능 분석)

  • Yun, H. S.;Chung, H.;Cho, Y. G.;Park, W. K.
    • Journal of Biosystems Engineering
    • /
    • v.25 no.3
    • /
    • pp.227-232
    • /
    • 2000
  • A natural air in-bin grain dryer with a grain circulator was developed for on farm use. Natural air drying test for rough rice was carried out to evaluate drying rate, uniformity of moisture content distribution in grain bed and energy consumption. It took 10 days to dry 8 ton of paddy rice from 21.9%(w.b) of moisture contents to 16.7%(w.b), by prototype dryer and the average drying rate was 0.52%/day. The uniformity of moisture content after drying was superior to a conventional natural air dryer in which grains were not mixed during drying periods. The dryer performance evaluation index was 738.3kJ/(kg.water), which was more effective than that of grain circulation type hot air dryer(3,500∼5,000 kJ/kg.water)

  • PDF

Numerical Study to Improve the Flow Uniformity of Blow-Down HVAC Duct System for a Train (전동차용 Blow-Down HVAC 덕트 시스템의 유동 균일도 향상을 위한 수치적 연구)

  • Kim, Joon-Hyung;Rho, Joo-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.1
    • /
    • pp.18-23
    • /
    • 2016
  • A HVAC(Heating Ventilation and Air Conditioning) is adapted to increase the comfort of the cabin environment for train. The train HVAC duct system has very long duct and many outlets due to the shape of a train set. the duct cross section shape is limited by a roof structure and equipments. Therefore, the pressure distribution and flow uniformity is an important performance indicator for the duct system. In this study, the existing blow down type HVAC duct system for a train was supplemented to improve the flow uniformity by applying a design method combining design of experiment (DOE) with numerical analysis. The design variables and the test sets were selected and the performance for each test set was evaluated using CFD(Computational Fluid Dynamics). The influence of each design variable on the system performance was analysed based on the results of the performance evaluation on the test sets. Furthermore, the optimized model, whose the flow uniformity was improved was produced using the direct optimization(gradient-based method). Finally, the performance of the optimized model was evaluated using numerical analysis, and it was confirmed that its flow uniformity has indeed improved.

Effects of the Floor Pannel on Flows in a Vertical Laminar Flow Type Clean Room (수직 층류형 클린룸의 바닥 패널이 실내기류에 미치는 영향)

  • Kang, S.H.;Jeon, W.P.;Oh, M.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.4
    • /
    • pp.303-315
    • /
    • 1990
  • Uniformity of velocity is quite important design points of a vertical laminar flow type clean room. In the present paper, flows in a room with a bottom pannel are numerically simulated by using a low-Reynolds number $k-{\epsilon}$ model, and a new flow model of the pannel are suggested. Resistance coefficient of the pannel and size of the exhaust channel show considerable effects on flow pattern and uniformity of flow on the bottom. Reflection coefficient also has important roles. A possibility to obtain the uniform and unidirectional flow is tested by adjusting the distribution of resistance coefficient of the pannel. Such a numerical simulation of the flow will be a good method to get optimun design parameters.

  • PDF

Analysis of Temperature Rise on the Air-Guide's Position of Wind Power Generator (풍력발전기 Air Guide 위치별 온도상승 해석)

  • Han, Chang-Woo;Kim, Hyun-Jae;Kweon, Ki-Yeoung;Lee, Hahk-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.282-285
    • /
    • 2008
  • In this paper, the numerical analysis of the model without air-guide was carried out in wind power generator. From numerical results, the temperature rise was not satisfied for the class F insulation and the non-uniformity of temperature distribution was a wide difference in heating elements. To improve these problems, the air-guide was installed in front of the coil head of non-drive end(NDE). The short distance between coil head and air-guide was more effective than long distance in cooling performance. Compared to that of the preliminary design, it was found that the cooling performance of the modification design was improved about 12%.

  • PDF

Spray Deposit Distribution of a Small Orchard Sprayer (소형 과수방제기 살포입자의 부착량 분포)

  • Koo, Young-Mo
    • Journal of Biosystems Engineering
    • /
    • v.32 no.3
    • /
    • pp.145-152
    • /
    • 2007
  • Uniformity of spray deposit is one of the important factors in spray performance affecting efficacy of pest management. Distributions of spray deposit on artificial targets were measured and analyzed to enhance the efficiency of spray application. The research was studied to understand the deposition characteristics of spray droplets and to determine the optimum conditions of chemical application. The deposit and its pattern by the lower fan speed was more uniform and higher than that by the higher fan speed. The upward blasting distance was limited within 3 m, but the limit to the ground level was expanded the distance more than 3.5 m because of the accumulated droplets. When the fan speed was higher at the distance of 2.5 m, deposit reached to maximum. When the distance increased, deposit was getting lower. At the both fan speeds, the deposit was concentrated below $30^{\circ}$ because of the gravitation and the resistance of wind. This research can be useful in designing an orchard sprayer and its operation for various tree canopies. To achieve a uniform distribution of deposit using the air-blast type orchard sprayer, the application rate from the middle boom should be increased as the air velocity to the upward increased. The spray rate to the side boom should be limited in a minimal level.

LCD 제조용 스퍼터링 장비의 비접촉식 유리평판 이송장치에 대한 수치적 연구

  • Gang, U-Jin;Im, Ik-Tae;Kim, U-Seung
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2007.06a
    • /
    • pp.149-156
    • /
    • 2007
  • Non-contact transportation of the large-sized glass plate using air-cushion is considered for sputtering system of LCD panel. The Argon gas from second gas injection holes is injected to levitate and transport the glass plate. Low maximum pressure and uniform pressure distribution on the bottom surface of the glass plate must be maintained for stable levitation and transportation of the glass plate. Therefore, the analysis of fluid flow between the glass plate and the air-pad is numerically performed for varying space between the injection holes in this study. The pressure uniformity on the bottom surface of the glass plate is evaluated for overall glass plate. The distance between the injection holes must be designed below 90 mm for obtaining the low maximum pressure and uniform pressure distribution.

  • PDF

The Effect of Various Processing Conditions on Temperature Distribution in Steam-air Retort (스팀-에어 레토르트의 온도분포에 미치는 공정 변수 영향)

  • Lee, Sun-Young;Shin, Hae-Hun;In, Ye-Won;Cho, Hyung-Yong
    • Food Engineering Progress
    • /
    • v.23 no.2
    • /
    • pp.87-93
    • /
    • 2019
  • Temperature distribution studies were performed in steam-air retort to investigate the influence of various processing conditions (come-up time, sterilization temperature, and internal pressure throughout the steam-air retort). Retort temperature data were analyzed for temperature deviations during holding phase, maximum temperature difference between test locations at the beginning and after 1, 3, and 5 min of the holding phase, and box-and-whiskers plots for each location during the holding phase. The results showed that high sterilization temperature led to a more uniform temperature distribution than low sterilization temperature (pasteurization). In pasteurization condition, the temperature stability was slightly increased by increasing pressure during the holding phase. On the other hand, the temperature stability was slightly decreased in high sterilization temperature condition. Programming of the come-up phase did not affect the temperature uniformity. In addition, the slowest cold spot was found at the bottom floor during the holding phase in all conditions. This study determined that the temperature distribution is affected by retort processing conditions, but the steam-air retort needs more validation tests for temperature stability.

Simulation for Improvement of Temperature Distribution Inside Refrigerator (냉장고 고내 온도산포 개선에 관한 전산모사)

  • Gao, Jia-Chen;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.12
    • /
    • pp.98-103
    • /
    • 2019
  • With the increasing need for environmental protection, it is particularly important to improve the energy saving and reliability of refrigerators. Generally, the cold air flowing into the freezer compartment transits to the bottom of the refrigerating compartment, which can lead to uneven temperature distribution. This paper proposes two design solutions for improving the temperature distribution problem. Of these, the optimal refrigeration design was selected and tested using Computational Fluid Dynamics (CFD) modeling and simulation. The results showed improved uniformity of the temperature distribution inside the refrigerator, thus benefitting food storage while reducing energy consumption.

Effects of Circulation Fans on Uniformity of Meteorological Factors in Warm Air Heated Greenhouse (순환팬이 온풍난방 온실의 기상분포 균일화에 미치는 영향)

  • Yu, In-Ho;Cho, Myeong-Whan;Lee, Si-Young;Chun, Hee;Lee, In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.16 no.4
    • /
    • pp.291-296
    • /
    • 2007
  • This study was conducted to investigate the effects of horizontal air flow produced by circulation fans on horizontal and vertical profiles of meteorological factors. The three-dimensional distributions of air speed, air temperature, relative humidity and carbon dioxide $(CO_2)$ concentration were measured with and without the fans in operation. The uniformity of the spatial distribution of meteorological factors decreased as the outside air temperature decreased. In "fans off" condition, spatial variations of $4.7^{\circ}C$ in air temperature, 19% in relative humidity were detected. When the fans were operated, these variations were reduced to 2.2 and 6.3%, respectively. As the fan capacity increased, the difference in air temperature among sampling points decreased. The fan capacity of $0.0104m^3{\cdot}s^{-1}{\cdot}m^{-2}$ was enough to obtain a reasonable air flow in greenhouse. The vertical profiles of air temperature and $CO_2$ concentration were reasonably uniform regardless of measurement height and fan capacity. Further researches on the position of fans to reduce the difference in air temperature along the width and the effects of using a larger number of smaller fans are required.

Studies on Combustion Synthesis of Carbon Nanotubes Using a Double-faced Wall Stagnation Flow Burner (양면정체유동버너를 이용한 탄소나노튜브 합성에 대한 연구)

  • Hong, Young-Taek;Woo, Sang-Kil;Kwon, Oh-Chae
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2154-2159
    • /
    • 2007
  • The potential of using a double-faced wall stagnation flow burner in mass production of carbon nanotubes was evaluated experimentally and computationally. With nitrogen-diluted premixed ethylene-air flames established on the Nickel-coated stainless steel double-faced wall, the propensities of carbon nanotube formation were experimentally determined using SEM and FE-TEM images and Raman spectroscopy, while the flame structure was computationally predicted using a 3-dimensional CFD code with a reduced reaction mechanism. The uniformity and yields of synthesized carbon nanotubes were evaluated in terms of the flame stretch rates. Results show substantial increase of area on the wall surface where uniform carbon nanotubes are synthesized with using the double-faced wall stagnation flow burner due to enhanced uniformity of temperature distribution along the wall surface and support the potential of using a double-faced wall stagnation flow burner in mass production of carbon nanotubes.

  • PDF