• Title/Summary/Keyword: Uniform flow

Search Result 1,423, Processing Time 0.026 seconds

Study on Effect of Convection Current Aeration System on Mixing Characteristics and Water Quality of Reservoir (대류식 순환장치의 저수지수체 유동특성 및 수질영향)

  • Lee, Yo-Sang;Lee, Kwang-Man;Koh, Deok-Koo;Yum, Kyung-Taek
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.1
    • /
    • pp.85-94
    • /
    • 2009
  • This study examines the operational effectiveness of a Convection Current Aeration System (CCAS) in reservoir. CCAS was run from June, 2008 when the thermocline begun forming in the reservoir. This paper reviews the influence of stratification, dissolved oxygen dynamics and temperature in the lake's natural state from June to October 2008. The survey was done on a week basis. Upwelling flow effects a radius of $7{\sim}10m$ at a surface directly and was irrelevant to the strength of thermocline. On the other hand, it was affected the number of working days, and strength of thermocline at vertical profiles of the reservoir. Longer CCAS run, the deeper was the vertical direct flow area. However it didn't break the thermocline during summer season of 2008. The operating efficiency of the CCAS in the reservoir depends on hydraulics and meteological conditions. Computational Fluid Dynamics (CFD) is a very useful tool for evaluating the operating efficiency of fluid dynamics. The geometry for CFD simulation consists of a cylindrical vessel 25 m radius and 40 m height. The CCAS is located in center of domain. The non-uniform tetrahedral meshes had a bulk of the geometry. The meshes ranged from the coarse to the very fine. This is attributed to the cold water flowing into the downcomer and rising, creating a horizontal flow to the top of the CCAS. The result of CFD demonstrate a closer agreement with surveyed data for temperature and flow velocity. Theoretical dispersion volume were calculated at 8m depth, 120 m diameter working for 30 days and 10 m depth, 130 m diameter working for 50 days.

Determination of Chimera Types and Ploidy Level of Sports from 'Campbell Early' Grape (Vitis labruscana) (포도 '캠벨얼리' 품종에서 발생한 아조변이체의 배수성 및 키메라 형태 검정)

  • Noh, Jung-Ho;Park, Kyo-Sun;Yun, Hae-Keun;Do, Gyung-Ran;Hur, Youn-Young;Kim, Seung-Hui;Lee, Han-Chan;Ryou, Myung-Sang;Park, Seo-Jun;Jung, Sung-Min
    • Horticultural Science & Technology
    • /
    • v.28 no.6
    • /
    • pp.996-1002
    • /
    • 2010
  • Flow cytometry (FCM) was used to measure the ploidy level of three different sports from 'Campbell Early' ($Vitis$ $labruscana$) grape. Results of the study showed different ploidy levels. FCM analysis for 'Campbell Early' grape which contains 2C DNA diploid cells showed single peak around 35-40 while 'Kyoho' grape with 4C DNA tetraploid cells had a different level of 70-80. However, analysis of the sports displayed a histogram with 2 peaks containing both 2C and 4C nuclei. There was no difference in histograms of 2C DNA flesh and pericarp; on the other hand, 4C DNA flesh type of sports had a different histogram from that of the 2C DNA pericarp. Chromosome numbers of diploid ('Campbell Early'), tetraploid ('Kyoho'), and three sports were counted under the microscope. 'Campbell Early' and 'Kyoho' have 38 and 76 chromosomes, respectively. Three different sports are mixoploids with mixtures of diploid and tetraploid cells. Microscopic observations of shoot apical meristems in sports from 'Campbell Early' grape were carried out to determine the type of plant chimera. 'Campbell Early' grape (diploid) and 'Kyoho' grape (tetraploid) showed that both had 2 tunica layers covering corpus cells, while the three different sports had tunica layers showing mostly oblique division. Most cells from 'Kyoho' grape were larger than 'Campbell Early' grape. Cells from L-2 and L-3 layers of the three sports were similar to 'Kyoho' grape in size, although all cells in L-1 surface layer were uniform in size like 'Campbell Early' grape. Results of FCM analysis indicated that both normal and polyploid cells could be intermixed in sports and could become mixoploidy consisting of diploid and tetraploid. All sports used in the tests were periclinal chimera plants with two distinct L-1 and L-2 cell layers. The result of this study suggests that all three sports which originated from 'Campbell Early' grape might be 2-4-4 type chimera formation.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

An Experimental Study on Radiation/Convection Hybrid Air-Conditioner (복사-대류 겸용 하이브리드 냉방기에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.288-296
    • /
    • 2019
  • Radiation cooling has used ceilings or floors as cooling surfaces. In such cases, to avoid moisture condensation on the surface, the surface temperature needs be higher than the dew point temperature or an additional dehumidifier is added. In this study, with a goal for residential application, intentional moisture condensation on the cooling surface was attempted, which increased the cooling capacity and improved the indoor comfortness. This method included two separate refrigeration cycles - convection-type dehumidifying cycle and the panel cooling cycle. Test results on the panel cooling cycle showed that, at the standard outdoor ($35^{\circ}C/24^{\circ}C$) and indoor ($27^{\circ}C/19.5^{\circ}C$) condition, the refrigerant flow rate was 8.8 kg/h, condensation temperature was $51^{\circ}C$, evaporation temperature was $8.8^{\circ}C$, cooling capacity was 376 W and COP was 1.75. Furthermore, the panel temperature was uniform within $1^{\circ}C$ (between $13^{\circ}C$ and $14^{\circ}C$). As the relative humidity decreased, the cooling capacity decreased. However, the power consumption remained approximately constant. In the convection-type dehumidification cycle, the refrigerant flow rate was 21.1 kg/h, condensation temperature was $61^{\circ}C$, evaporation temperature was $5.0^{\circ}C$, cooling capacity was 949 W and COP was 2.11 at the standard air condition. When both the radiation panel cooling and the dehumidification cycle operated simultaneously, the cooling capacity of the radiation panel cycle was 333 W and that of the dehumidification cycle was 894 W, and the COP was 1.89. As the fan flow rate decreased, both the cooling capacity of the radiation panel and the dehumidification cycle decreased, with that of the dehumidification cycle decreasing at a higher rate. Finally, a possible control logic depending on the change of the cooling load was proposed based on the results of the present study.

Chemistry of mist deposition of organic polymer PEDOT:PSS on crystalline Si

  • Shirai, Hajime;Ohki, Tatsuya;Liu, Qiming;Ichikawa, Koki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.388-388
    • /
    • 2016
  • Chemical mist deposition (CMD) of poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) was investigated with cavitation frequency f, solvent, flow rate of nitrogen, substrate temperature $T_s$, and substrate dc bias $V_s$ as variables for efficient PEDOT:PSS/crystalline (c-)Si heterojunction solar cells (Fig. 1). The high-speed camera and differential mobility analysis characterizations revealed that average size and flux of PEDOT:PSS mist depend on f, solvent, and $V_s$. The size distribution of mist particles including EG/DI water cosolvent is also shown at three different $V_s$ of 0, 1.5, and 5 kV for a f of 3 MHz (Fig. 2). The size distribution of EG/DI water mist without PEDOT:PSS is also shown at the bottom. A peak maximum shifted from 300-350 to 20-30 nm with a narrow band width of ~150 nm for PEDOT:PSS solution, whose maximum number density increased significantly up to 8000/cc with increasing $V_s$. On the other hand, for EG/water cosolvent mist alone, the peak maximum was observed at a 72.3 nm with a number density of ~700/cc and a band width of ~160 nm and it decreased markedly with increasing $V_s$. These findings were not observed for PEDOT:PSS/EG/DI water mist. In addition, the Mie scattering image of PEDOT:PSS mist under white bias light was not observed at $V_s$ above 5 kV, because the average size of mist became smaller. These results imply that most of solvent is solvated in PEDOT:PSS molecule and/or solvent is vaporized. Thus, higher f and $V_s$ generate preferentially fine mist particle with a narrower band width. Film deposition occurred when $V_s$ was impressed on positive to a c-Si substrate at a Ts of $30-40^{\circ}C$, whereas no deposition of films occurred on negative, implying that negatively charged mist mainly provide the film deposition. The uniform deposition of PEDOT:PSS films occurred on textured c-Si(100) substrate by adjusting $T_s$ and $V_s$. The adhesion of CMD PEDOT:PSS to c-Si enhanced by $V_s$ conspicuously compared to that of spin-coated film. The CMD PEDOT:PSS/c-Si solar cell devices on textured c-Si(100) exhibited a ${\eta}$ of 11.0% with the better uniformity of the solar cell parameters. Furthermore, ${\eta}$ increased to 12.5% with a $J_{sc}$ of $35.6mA/cm^2$, a $V_{oc}$ of 0.53 V, and a FF of 0.67 with an antireflection (AR) coating layer of 20-nm-thick CMD molybdenum oxide $MoO_x$ (n= 2.1) using negatively charged mist of 0.1 wt% 12 Molybdo (VI) phosphoric acid n-Hydrate) $H_3(PMo_{12}O_40){\cdot}nH_2O$ in methanol. CMD. These findings suggest that the CMD with negatively charged mist has a great potential for the uniform deposition of organic and inorganic on textured c-Si substrate by adjusting $T_s$ and $V_s$.

  • PDF

Depositional Environments and Characteristics of Surface Sediments in the Nearshore and Offshore off the Mid-Western Coast of the Korean Peninsula (한반도 중서부 근 ${\cdot}$ 외해의 표층 퇴적물 특성과 퇴적환경)

  • Oh, Jae-Kyung;Kum, Byung-Chul
    • Journal of the Korean earth science society
    • /
    • v.22 no.5
    • /
    • pp.377-387
    • /
    • 2001
  • In order to elucidate sedimentation processes and depositional environments in transitional area between continental shelf and coastal zone, sedimentologic study has been done with 84 surface sediments sampled in nearshore/offshore off the mid-western coast of the Korean Peninsula for 3 years (1996${\sim}$1999). The surface sediment can be classified into 4 facies (gravelly sand, sand, silty sand and sandy silt). Mean grain size, sorting, skewenss and kurtosis varies -0.39${\sim}7.82{\Phi}$, 0.36${\sim}4.68{\Phi}$, -0.38${\sim}$0.86, -1.56${\sim}$3.43, respectively. The textural parameters show a finer-grained and poorly-sorted trend shoreward, northward and southward from the central part of the study area. The positively-skewed distribution and relationship of each textural parameters indicate a tide-dominated depositional environment. According to C/M diagram, there are 3 different domains (mode A, B, C) of sediment transport mode. The northern part is characterized by bedload transport (mode A) and represents co-influence of wave and tide, whereas domain C in the southern part is controlled by uniform suspension transport (mode C), correlating with sandy-silt area. In the broad middle area, transport processes are complex (the mixture of bedload, graded suspension and uniform suspension; mode B). Hence, the subdivision depositional environments of this study area may be classified by 3 depositional environments dependent on the interplay of sediment supplies from river, relict sediments and hydrologic conditions. In results, the nearshore and offshore areas are thus characterized as a mixing zone between coastal terrigenous sediments and relict sediments in the continental shelf by complex processes (tide, wave and river flow). These sedimentation processes play an important role in producing distinct sedimentologic features in the transitional zone linking coastal and shelfal areas.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

Petrological and Mineralogical Characteristics and Firing Temperature of Pottery in the 5-6th Century from Changnyeong, Gyeongsangnamdo (경상남도 창녕에서 출토된 5-6세기 토기의 암석광물학적 특성 연구 및 소성온도 추정)

  • Woo, Hyeon Dong;Kim, Ok Soon;Jang, Yun Deuk
    • Journal of the Mineralogical Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.63-72
    • /
    • 2014
  • This study is conducted to investigate mineralogical characteristics and estimate firing temperature and condition of earthenwares in the 5-6th Century which are found at ancient tombs in Gyo-dong, Gyo-ri, Changnyeong-eup, Changnyeong-gun, Gyeongsangnam-do, TKorea by applying petrological methods. For this study, mineralogical analysis, microtexture observation and chemical analysis were conducted. According to observations using a polarization microscope, the potshreds are mainly composed of quartz and feldspar and consist of some felsic volcanics, tempers, opaques and mullite, hematite and spinel were found under XRD and FTIR analysis. The flow pastes are observed in many potshreds, and it indicate that this textures made by the mixing process or the pottery made from the mixture of 2 sorts of clays at least. They dose not show the features of the potshreds firing under temperature of $1,200-1,300^{\circ}C$ rather than the earthenware firing under relatively low temperature of $1,000^{\circ}C$ approximately because of the existence of a number of pores and the crystals of the specific minerals. The growths mostly of mullite on the surface and into the cracks of the potshreds indicate that the firing condition was not uniform to make even temperature and oxidation. Most of the pottery shreds have felsic volcanic fragments and some of them have cristobalite which is formed at the temperature of more than 1,470^{\circ}C$. But considering the estimated firing temperature, these are not formed during firing but included in the original clay.

Development of Commercial-scaled Pervaporation Hollow Fiber Membrane System for High Pressure and High Temperature Applications (고온 고압용 상업적 규모의 중공사 투과증발 막시스템 개발)

  • Yeom, Choong Kyun;Kang, Kyeong Log;Kim, Joo Yeol;Ahn, Hyo Sung;Kwon, Konho
    • Membrane Journal
    • /
    • v.23 no.4
    • /
    • pp.257-266
    • /
    • 2013
  • The main purpose of this study is to develop a commercial scale of pervaporative process equipped with hollow fiber membrane modules, being able to effectually purify organic solvent at high temperature well over its boiling point under high vapor pressure. Three constituent technologies have been developed; 1) to fabricate braid-reinforced hollow fiber membrane stable in high pressure and high temperature application, 2) to design and fabricate a commercial scale of hollow fiber membrane module, and 3) to design and fabricate a pilot scale of pervaporation equipment system. The developed hollow fiber membrane possesses a membrane performance superior to the membrane of Sulzer (Germany) which is the most-well known for pervaporation process, and the membrane module equips hollow fiber membranes of $4.6m^2$ and the pervaporation system can treat organic liquid at 200 L/h, which is based on the dehydration of 95 wt% isopropyl alcohol (IPA). Since the membrane module is designed to flow in and pass through the inside of individual hollow fiber membrane, not to involve both the formation of feed's dead volume observed in flat-sheet membrane module and the channeling of feed occurring inside hollow fiber bundle which lower membrane performance seriously, it showed excellent separation efficiency. In particular, the module is inexpensive and has less heat loss into its surrounding, in compared with flat-sheet membrane module. In addition, permeant can be removed effectively from the outer surface of hollow fiber membrane because the applied vacuum is conveyed uniformly through space between fibers into respective fiber, even into one in the middle of the hollow fiber bundle in which the space between fibers is uniform in distance. Since the hollow fiber membrane pervaporation system is the first one ever developed in the world, our own unique proprietary technology can be secured, preoccupying technical superiority in export competitive challenges.

Liquid-Liquid Dispersion of an Immiscible Liquid Phase (n-Hexane/Water) System in a Stirred Tank (교반조에서 비혼화성 액상(n-헥산/물)계의 액-액분산)

  • Kim, Tae-Ok;Kim, Dong-Uk;Chun, Jong-Han
    • Applied Chemistry for Engineering
    • /
    • v.4 no.3
    • /
    • pp.537-543
    • /
    • 1993
  • The effect of agitation on liquid-liquid dispersion was investigated in an immisible liquid phase(n-hexane/water) system. Four different types of six-bladed turbine impellers were used: a flat blade, two screen blades and a solid edged 60 mesh screen blade. We found that the extent of dispersion of organic phase and power consumption of agitator were decreased in the order of flat, solid edged, 60 mesh, and 40 mesh blades at same agitation speed. And the minimum agitation speed for complete dispersion of organic phase was increased with increasing volume fraction of organic phase. Also, mean diameter of liquid droplets of dispersed phase was decreased with increasing agitation speed and it was increased in the order of solid edged, flat, 60 mesh, and 40 mesh screen blades at same agitation speed. At complete dispersion, the minimum power consumption was not vary significantly with impeller blade types, but the solid edged screen blade impeller gave the smallest and uniform sizes of liquid droplets, and it had a good performance for liquid-liquid dispersion. In this condition, Power number was not affected by Reynolds number and it was constant in turbulent flow region, and Sauter mean diameter($d_{32}$) of liquid droplets was expressed as a function of volume fraction of organic phase(${\phi}$) and Weber number($N_{We}$) as follows: $d_{32}/D=a(1+b{\phi})N_{We}{^{-0.6}}$.

  • PDF