• 제목/요약/키워드: Unified power model

검색결과 98건 처리시간 0.022초

태양광 발전 시스템용 3-레벨 부스트 컨버터 제어기 설계에 관한 연구 (A Study on the Controller Design of the Three-Level Boost Converter for Photovoltaic Power Conditioning System)

  • 이규민;김일송
    • 전력전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.227-236
    • /
    • 2021
  • This research proposes a modeling and controller design of a three-level boost (TLB) converter for the implementation of maximum power point tracking (MPPT) in the photovoltaic power conditioning system (PCS). Contrary to the output voltage control of the conventional controller, the Photovoltaic PCS requires an input voltage controller for MPPT operation. A TLB converter has the advantage of decreasing the inductor size and increasing efficiency compared with the existing booster converter. However, an optimal controller is difficult to design due to the complexity of the TLB operations, which have two operational modes on the duty ratio boundary of 0.5. Therefore, the unified linear model equations of the TLB converters, which can be applicable to both operational modes, are derived using linearized solar cell expressions. Furthermore, the transfer functions are obtained for the controller design. The MPPT voltage controller is designed using MATLAB SISOTOOL. In addition, a controller for capacitor voltage unbalancing is described and designed. The simulations and experimental verifications are conducted to verify the effectiveness of the small-signal analysis and control system design.

다중브리지로 구성된 UPQC(Unified Power Quality Conditioner)의 동적 성능분석 (Dynamic Performance Analysis of Unified Power Quality Conditioner with Cascaded H-Bridges)

  • 조윤호;배병열;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.241-243
    • /
    • 2006
  • This paper describes experimental analysis of UPQC, which is composed of cascaded H-bridges and single-phase multi-winding transformers. The operational characteristic was analyzed through experimental works with a scaled model, and simulations with PSCAD/EMTDC. The UPQC proposed in this paper can be directly connected to the distribution line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual UPQC system applicable for the actual distribution system.

  • PDF

H-브리지로 구성된 UPQC(Unified Power Quality Conditioner)의 축소모형 실험결과 분석 (Experimental Analysis Result of Unified Power Quality Controller with Cascaded H-Bridges using Scaled Prototype)

  • 조윤호;한병문;김현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.93-96
    • /
    • 2005
  • This paper describes experimental analysis of UPQC, which is composed of cascaded H-bridges and single-phase multi-winding transformers. The operational characteristic was analyzed through experimental works with a scaled model, and simulations with PSCAD/EMTDC. The UPQC proposed in this paper can be directly connected to the distribution line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual UPQC system applicable for the actual distribution system.

  • PDF

Modeling and Analysis of the KEPCO UPFC System by EMTDC/PSCAD

  • Yoon, Jong-Su;Kim, Soo-Yeol;Chang, Byung-Hoon;Lim, Seong-Joo;Choo, Jin-Boo
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권3호
    • /
    • pp.148-154
    • /
    • 2003
  • This paper describes the development of KEPCO's 80MVA UPFC electromagnetic transient model and the analysis of its performance in the actual Korean power system. KEPCO's 80MVA UPFC is currently undergoing installation and will be ready for commercial operation from the year 2003. In order to apply a new FACTS device such as the UPFC to the actual power system, the utility needs, in advance, both load flow stability studies and transient studies. Therefore, KEPRI, the research institute of KEPCO, developed a detailed transient analysis model that is based on the actual UPFC S/W algorithm and H/W specifications. This simulation model is implemented by an EMTDC/PSCAD package. The results of the simulation show the effectiveness of UPFC operation in the KEPCO power system.

최적의 UPFC 위치 결정에 관한 연구 (A Study on the Determination of Optimal UPFC Location)

  • 배철오
    • 해양환경안전학회지
    • /
    • 제15권3호
    • /
    • pp.257-262
    • /
    • 2009
  • 일체형 조류제어기인 UPFC는 FACTS 기기중 가장 효과적인 기기 중 하나이다. 본 논문에서는 전력시스템에서 UPFC의 최적위치를 결정하는 데 필요한 컴퓨터의 계산을 줄이는 방법에 대하여 기술한다. 이를 위해 UPFC 제어 변수들과 관련된 발전 비용의 민감도가 평가되었다. 모든 송전선로의 UPFC 민감도를 얻기 위해 단지 한 번의 최적조류제어만으로 해결하였다. 전력시스템에서 UPFC의 최적 위치를 알아내기 위해 여러 권선비와 가변 션트 어드미턴스로 구성된 이상변압기 모델을 사용하였다. 이 모델에서 UPFC 제어 변수들은 UPFC 입 출력의 전류와 전압에 대해서 종속되지 않는다. 민감도 방법은 그의 효율성을 파악하기 위해 IEEE 14 모선에서 파생된 5 모선시스템과 IEEE 14 모선시스템을 대상으로 실험하였다.

  • PDF

통합기술수용이론 관점에서 블록체인기술의 사용자 수용과 이용 행동에 관한 연구 (A Study on the Acceptance Intention and Usage Behavior of Blockchain Technology : From the Perspective of Unified Theory of Acceptance and Use of Technology)

  • 김병곤;이병길;윤일기
    • Journal of Information Technology Applications and Management
    • /
    • 제27권3호
    • /
    • pp.1-18
    • /
    • 2020
  • Recently, following the development of FinTech technology that combines finance and information and communication technology, the need and social demands for a block chain technology-based trading system have increased significantly. In this study, a research model was developed and hypothesized through literature research on the concept of block chain technology, the technology acceptance model, and the unified theory of acceptance and use of technology. The research theories were tested by collecting data through surveys and analyzing the collected data. This study conducted empirical research to identify the factors influencing the user acceptance intention and utilization behavior of the block chain technology in introducing the block chain technology. First, factors affecting the acceptance intention of the blockchain user were performance expectation, effort expectation, social impact, and blockchain transparency variables. Second, the facilitation conditions and stakeholder confidence variables were analyzed as factors that did not affect the acceptability of the blockchain users. Third, variables such as blockchain transparency, stakeholder trust and intention of acceptance are factors that affect the usage behavior of the blockchain. Fourth, it was confirmed that the acceptance intention had a very high explanatory power on usage behavior of Blockchain technology.

게임이론을 적용한 전력시장 전력거래방식의 후생 측면 비교 연구 (A Comparative Welfare Analysis on the Trading System in an Electricity Market by Using Game Theory)

  • 이광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권10호
    • /
    • pp.616-623
    • /
    • 2003
  • Competition among electric generation companies is a major goal of restructuring in the electricity industry, The trading system in an electricity market has been one of the most important issues in deregulated electricity market. This paper deals with comparisons of the major two types of the trading system: compulsory pool market and bilateral contract market. The two trading systems are compared quantitatively from the viewpoint of consumer's surplus and social welfare, This paper, also, proposes a unified model of Cournot and Bertrand for analyzing the mixed trading system of pool market and bilateral contract market. Nash equilibrium of the unified model is derived by criteria for participating in bilateral contract market. Numerical results from a sample case show that a mixed trading system of pool market and price-competitive bilateral market is beneficial to consumer from the view points of consumer's surplus.

조류계산을 위한 분리된 UPFC 모형에서의 제한값 해결 (Limit Resolution in the Decoupled UPFC Model for Power Flow)

  • 김태현;서장철;임정욱;문승일;박종근;한변문
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권7호
    • /
    • pp.824-831
    • /
    • 1999
  • This paper presents new methods to resolve the important limits in the decoupled UPFC model for power flow, by which conventional power flow program can be performed with addition of two buses per one UPFC. In order to operate UPFC to the desired value, the series voltage and shunt current of UPFC should be computed. So a method of calculating these by simple equations after power flow is derived. However, the calculated magnitude of series voltage and/or shunt current of UPFC may not be allowed because of the UPFC limit \ulcorner to the ratings of inverters. In this case, the active power and the reactive power (or the voltage magnitude) of UPFC buses should be revised to resolve the limit. This paper proposes the Newton Raphson method to resolve these limits. Particularly, when resolving the series voltage magnitude, three strategies are proposed according to the priority of the active power and the reactive power (or the voltage magnitude).

  • PDF

UPFC가 계통에 미치는 영향을 선로정수 G, B의 함수로 표현한 새로운 UPFC 정태 해석모델 개발 (The Development of New UPFG Steady-State Model using Transmission Line Constant G. B)

  • 전동훈;김태균;추진부;김건중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1167-1169
    • /
    • 1999
  • This paper presents the new unified power flow controller(UPFC) load flow algorithm using UPFC transmission line constant model. The UPFC transmission line constant model represents a function of transmission line constant(G.B) UPFC's effect in power system. It can easily be incorporated in a load flow program. The algorithm is suited for monitoring the power system state as well as determining the magnitude and Phase angle of UPFC serial voltage source.

  • PDF