• Title/Summary/Keyword: Uneven surface

Search Result 195, Processing Time 0.027 seconds

Identifying and quantitating defects on chemical vapor deposition grown graphene layers by selected electrochemical deposition of Au nanoparticles

  • So, Hye-Mi;Mun, Jeong-Hun;Bang, Gyeong-Sook;Kim, Taek-Yong;Cho, Byung-Jin;Ahn, Chi-Won
    • Carbon letters
    • /
    • v.13 no.1
    • /
    • pp.56-59
    • /
    • 2012
  • The defect sites on chemical vapor deposition grown graphene are investigated through the selective electrochemical deposition (SED) of Au nanoparticles. For SED of Au nanoparticles, an engineered potential pulse is applied to the working electrode versus the reference electrode, thereby highlighting the defect sites, which are more reactive relative to the pristine surface. Most defect sites decorated by Au nanoparticles are situated along the Cu grain boundaries, implying that the origin of the defects lies in the synthesis of uneven graphene layers on the rough Cu surface.

Reduction of the residual stresses during the additive manufacturing of a thermo-viscoelastic growing cylinder under non-uniform volumetric heating by electric induction

  • Fekry, Montaser
    • Structural Engineering and Mechanics
    • /
    • v.82 no.2
    • /
    • pp.259-270
    • /
    • 2022
  • The paper investigates the residual stresses arising in a thermoviscoelastic cylinder as a result of layer-by-layer deposition of material on its lateral surface. Internal stresses are caused by incompatible deformations that accumulate in the assembly as a result of joining parts with different temperatures. For the analysis of internal stresses, an analytical solution to the axisymmetric quasi-static problem of thermoelasticity for a growing cylinder is constructed. It is shown that the distribution of residual stresses depends on the scenario of the surfacing process. In this case, the supply of additional heat to the growing body can significantly reduce the unevenness of temperature fields and reduce the intensity of residual stresses. The most effective is uneven heating, which can be realized, by the action of an alternating current with a tunable excitation frequency. The temperature and residual stresses fields on the growing surface is analyzed numerically for Titanium and Copper materials.

Thermal buckling of porous FGM plate integrated surface-bonded piezoelectric

  • Mokhtar Ellali;Khaled Amara;Mokhtar Bouazza
    • Coupled systems mechanics
    • /
    • v.13 no.2
    • /
    • pp.171-186
    • /
    • 2024
  • In the present paper, thermal buckling characteristics of functionally graded rectangular plates made of porous material that are integrated with surface-bonded piezoelectric actuators subjected to the combined action of thermal load and constant applied actuator voltage are investigated by utilizing a Navier solution method. The uniform temperature rise loading is considered. Thermomechanical material properties of FGM plates are assumed to be temperature independent and supposed to vary through thickness direction of the constituents according to power-law distribution (P-FGM) which is modified to approximate the porous material properties with even and uneven distributions of porosities phases. The governing differential equations of stability for the piezoelectric FGM plate are derived based on higher order shear deformation plate theory. Influences of several important parameters on the critical thermal buckling temperature are investigated and discussed in detail.

The effect of conditioning by Tetracycline-Hcl on implant surface;The SEM study and. surface roughness measurements : RBM surface (염산 테트라싸이클린이 RBM적용 임프란트 표면구조에 미치는 영향의 미세구조 및 표면 거칠기 변화에 관한 연구)

  • Lim, Hae-Soo;Park, Joon-Bong;Kwon, Young-Hyuk;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.585-597
    • /
    • 2007
  • The present study was performed to evaluate the effect of Tetracycline-HCI and Saline on the change of implant surface microstructure and surface roughness according to application time. Implants with resorbable blasting media surface were utilized. Before test all 13 implants were measured surface roughness. Among them, 6 implants were rubbed with 50mg/ml Tetracycline-HCl solution and other 6 implants with saline for $\frac{1}{2}$min., 1min., $1\frac{1}{2}$min., 2min., $2\frac{1}{2}$min and 3min. Then, specimens were processed for scanning electron microscopic observation and surface roughness after test. The results of this study were as follows. 1. Control group showed a few irregular, rough, uneven surface with crater-like depression. 2. The test group with Tetracycline-HCl conditioning showed an altered surface when Tetracycline-HCl was applied for 30secs, and showed a various surface alteration as application times go on. 3. The test group with Saline conditioning showed no significant surface differences and surface roughness. 4. The significant increase of Ra value was showed when Tetracycline-HCl was applied for 30secs. In conclusion, the 50mg/ml Tetracycline-HCl must not be applied for the RBM surface implant for surface treatment.

The Change of Hair Surface According to Perm Treatment Method (퍼머 시술방법에 따른 모발표면의 변화)

  • Kim, Jung-Hae;Yoo, Tae-Soon;Jung, Youn
    • Fashion & Textile Research Journal
    • /
    • v.9 no.3
    • /
    • pp.341-346
    • /
    • 2007
  • This research is the hair damage as treating a perm before and after that is compared the change of surface characteristics of human hair. On the basis of this, we would to show a basic data for hair damage prevention and hair improvement to keep the beautiful and healthy hair. Results are as follows; For the change of formational characteristics of hair surface, untreated hair before the perm treatment had smooth appearance overall and undamaged scale that is in pattern and finely folded was observed but damaged hair and extremely hair had uneven edge and damages throughout along with the dissolution of scale which the border of epidermal gap is unclear. Hair after a perm treatment caused cortical exposures due to extensive loss of scale during the treatment and even bubble effect. Protein perm, regular perm, soft perm, and direct heating perm, in that order, had the most damages to the hair.

Effect of silica fume content in concrete blocks on laser-induced explosive spalling behavior

  • Seong Y. Oh;Gwon Lim;Sungmo Nam;Byung-Seon Choi;Taek Soo Kim;Hyunmin Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.1988-1993
    • /
    • 2023
  • This experimental study investigated the effect of silica fume mixed in concrete blocks on laser-induced explosion behavior. We used a 5.3 kW fiber laser as a thermal source to induce explosive spalling on a concrete surface blended with and without silica fume. An analytical approach based on the difference in the removal rate and thermal behavior was used to determine the effect of silica fume on laser-induced explosive spalling. A scanner was employed to calculate the laser-scabbled volume of the concrete surface to derive the removal rate. The removal rate of the concrete mixed with silica fume was higher than that of without silica fume. Thermal images acquired during scabbling were used to qualitatively analyze the thermal response of laser-induced explosive spalling on the concrete surface. At the early stage of laser heating, an uneven spatial distribution of surface temperature appeared on the concrete blended with silica fume because of frequent explosive spalling within a small area. By contrast, the spalling frequency was relatively lower in laser-heated concrete without silica fume. Furthermore, we observed that a larger area was removed via a single explosive spalling event owing to its high porosity.

The Micromorphometric change of the GBA and RBM implant surface conditioned with tetracycline-HCI (염산테트라싸이클린 적용시간에 따른 GBA 및 RBM 임프란트 표면변화)

  • Park, Kang-Hun;Herr, Yeek;Kwon, Young-Hyuk;Park, Joon-Bong;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.3
    • /
    • pp.705-716
    • /
    • 2006
  • The present study was performed to evaluate the effect of tetracycline-HCl on the change of implant surface microstructure according to application time. Implant with pure titanium machined surface, GBA surface and RBM surface were utilized. Implant surface was rubbed with 50mg/ml tetracycline-HCl solution for ${\frac{1}{2}}$min. 1min. $1{\frac{1}{2}}$min. 2min. and $2{\frac{1}{2}}$min. respectively in the test group. Then, specimens were processed for scanning electron microscopic observation. The results of this study were as follow. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two group. 2. In GBA surfaces, control group exhibit many porous depression, and each depression were divided by strict border. Experimental group applied with tetracycline-HCl for 2min. were similar with control group. But when applied for $2{\frac{1}{2}}$min. surface alteration and border breakdown started, resulting enlargement of the porous depression. 3. In REM surface, control group exhibit rough, uneven surface with crater-like depression can be found. The surface alteration started when tetracycline-HCl was applied for 30sec. resulting breakdown of the crater-like depression. Depression became larger as applying time increased.

Sensitivity improvement of $CeO_2$ oxygen sensor by betterment of surface characteristics through chemical mechanical polishing process (CMP 공정을 통한 표면 특성 개선에 의한 $CeO_2$ 산소 센서 감도 향상 연구)

  • Jung, Pan-Gum;Jun, Young-Kil;Ko, Pil-Ju;Kim, Nam-Hoon;Lee, Woo-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.65-65
    • /
    • 2007
  • Microstructure and surface roughness of the sensing materials should be improved to use them in advanced sensor applications because the uneven surface roughness degrades the light reflection, pattern resolution, and devices performance. Chemical mechanical polishing (CMP) processing was selected for improving the surface roughness of $CeO_2$ which is one of the well known materials for the oxygen gas sensors. Surface roughness and removal rate of spin coated $CeO_2$ thin films were examined with a change of CMP process parameters such as down force and table speed. The optimized process condition, reflected by the surface roughness with the hillock-free surface as well as the excellent removal rate with the good uniformity, was obtained. The effects of the improved surface roughness on the sensing property of $CeO_2$ thin films were also confirmed. The improved sensitivity of $CeO_2$ thin films for oxygen sensors were obtained after CMP process by the improved surface characteristics. Therefore, we conclude that sensing property of $CeO_2$ thin film is strongly dependent on the surface roughness of $CeO_2$ thin films by using CMP process.

  • PDF

A Study on Machinability of SM55C for Deep Hole Drilling (Deep Hole 가공시 SM55C의 절삭성에 관한 연구)

  • 이충일
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.177-182
    • /
    • 1997
  • The purpose of this study is to analyze how tools, guide bush type and the change of cutting speed have effects on the diameter of cutting hole, surface roughness of workpiece and roundness during the deep hole machining of SM55C with solid BTA drill by using BTA drilling system through experiment. Conclusion reached is as follows. (1) The diameter was expanded for 25${\mu}{\textrm}{m}$ at the first section and then was reduced 0${\mu}{\textrm}{m}$ and 15${\mu}{\textrm}{m}$ respectively at the 10m and 20m section comparing to the diameter of tool with respect to the variation of cutting length. (2) It was proved that roughness was below 12S for the whole section of cutting length. (3) The roundness has been below 12${\mu}{\textrm}{m}$. Regarding the polygon phenomenon, it has bee proved that not only uneven number of angle but also even number (quadrilateral, elliptical) of angle were made. (4) Variation of diameter, surface roughness of workpiece and roundness turned out to ve the best at 70m/min of cutting speed, 0.15mm/rev of feed.

  • PDF

A Study on Electrostatic Powder Coating for 3D Scanning of Diffused Surfaces (난반사 표면의 3D 스캐닝을 위한 정전분말코팅 연구)

  • Maeng, Heeyoung;Lee, Myoung Sang
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.1
    • /
    • pp.56-62
    • /
    • 2015
  • Using an optical 3D scanning device to collect data from a diffused reflection surface is very difficult. To solve this problem, there are many applications including a spray-type developer and silicon molds. However, using a developer can cause chemical reactions between objects and particles of the developer and uneven surfaces on the object. To overcome these problems, we suggest an electrostatic powder coating method for even coating of particles onto surfaces for collecting 3D shape data. We have developed an automatic, electrostatic powder-coating machine and performed three different experiments to compare this system with a laser interferometer and a T-scan 3D scanner. As a result, we could ascertain the various characteristics of this new method, including good sensitivity for the various surface states of the bare surface, developer, and electrostatic powder coating. Finally, we verified the outstanding scanning performance and were able to demonstrate that this method achieves quality than traditional methods.