• 제목/요약/키워드: Underwater concrete structures

검색결과 35건 처리시간 0.019초

수중 및 습윤 환경구조물 보수용 에폭시 모르타르의 경화제 종류에 따른 공학적 특성에 관한 연구 (A Study on the engineering Properties of Repairing Epoxy-Mortar According to Hardener types for Structures under Underwater and Humidity)

  • 박덕준;박상훈;이대경;배기선;김진만;백신원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.277-280
    • /
    • 2005
  • Epoxy-mortar composites have been wildly used as finishing and repairing materials in the construction because of their excellent properties. Conventional epoxy-mortars and concretes have an inferior applicability and cost performance ratio due to the two component mixing of the epoxy resin and hardener. In this study, we examined the engineering effect of compressive strength and flexible strength according to the various epoxy-hardener in underwater and humidity environment, and evaluated the hardener types and physical effect of Epoxy mortar using cement binder in underwater and air condition. In this study, it was clarified that the engineering properties of repairing epoxy-motars were effected by the type of hardener.

  • PDF

고장도용 수중불분리성 콘크리트의 현장적용을 위한 연구 (A Study for In-situ Application of High Strength Antiwashout Underwater Concrete)

  • 문한영;송용규;이승훈;정재홍
    • 콘크리트학회논문집
    • /
    • 제13권4호
    • /
    • pp.336-345
    • /
    • 2001
  • 수중콘크리트는 재료분리에 의한 품질의 저하, 현장 주변의 오염 등 문제점이 있을 뿐만 아니라 고강도 및 초대형 수중콘크리트 구조물을 축조해야 할 필요성이 요구되면서 새로운 재료 및 공법의 개발이 요망된다. 그래서 수중불분리성 콘크리트의 재료분리와 수화열의 저감 및 장기강도 증진을 목표로 제조한 수중불분리성 콘크리트의 현장적용성에 대한 연구를 착안하게 되었다. 모형 실험체(I)에 의한 실험결과, 슬럼프 플로우 58cm인 수중불분리성 콘크리트를 24㎥/hr 정도의 속도로 타설할 경우, 5m의 단부까지 약 1분 정도 소요되었으며, 타설면은 거의 수평을 유지하는 시공성을 나타내었으며, 각 부위별 코어 공시체의 압축강도는 240 kgf/$\textrm{cm}^2$을 상회하는 값임을 알 수 있었다. 한편, 모형 실험체(II)에 사용된 고강도용 수중불분리성 콘크리트의 pH값과 현탁물질량은 각각 경과시간 30분에서 10.0~11.0 및 51 mg/$\ell$, 초결 및 종결시간은 각각 30 및 37시간 정도 그리고 슬럼프플로우 값은 53$\pm$2cm범위였다. 이 콘크리트로서 27㎥/hr 정도의 속도로 타설한 결과, 철근 배근의 유무에 관계없이 유동속도는 큰 차이가 없었으며 유동 구배는 거의 수평면을 유지하였다. 코어 공시체의 압축강도 및 탄성계수는 유동거리가 멀어질수록 약간 감소하였으나 중앙부위에서 가장 큰 값을 나타내었다.

해양에 위치한 고속도로교량에 대한 내염보수 공법(2)-전기방식시공결과 (Repair of Highway Bridge damaged by Chloride Attack in Marine Environment(2) - Application of Cathodic Protection)

  • 지한상;한복규;정해문;안태송;류종현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.786-789
    • /
    • 2004
  • Corrosion of reinforced concrete structures in marine environment is one of the most important mechanism of deterioration. However, conventional rehabilitation techniques in tidal zone, which consist of removing delaminated areas of concrete, cleaning affected steel and patching with portland cements mortar, have proven to be ineffective for marine structures. Also, repairs are often repeated every several years. The purpose of this report is to announce appropriate repair method of highway bridge damaged by chloride attack in marine environment (application of cathodic protection) using FRP and antiwashout underwater mortar.

  • PDF

반발경도와 초음파속도를 이용한 수중 콘크리트 구조물의 압축강도 예측 기술 (Compressive Strength Estimation Technique of Underwater Concrete Structures using Both Rebound Hardness and Ultrasonic Pulse Velocity Values)

  • 신은석;이지성;박승희;한상훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권4호
    • /
    • pp.118-125
    • /
    • 2014
  • 본 논문은 기존 수중 콘크리트 구조물의 강도관리 및 진단기술의 중요성은 날로 증가함에 따라 개발되고 있는 ROV (Remote Control Vehicle)에 탑재될 수 있는 비파괴 검사 장비를 개발하여 콘크리트 내부의 강도측정을 하고자하였다. 수중화된 슈미트해머와 초음파센서를 통하여 수중에 있는 콘크리트 공시체의 반발경도 및 초음파속도를 계측하여 실제 압축강도 값과 비교하였으며 이를 통하여 수중에서의 강도추정식을 도출하였다. 도출된 3가지 식 중에서 반발경도와 초음파속도를 복합적으로 사용하는 복합식이 가장 정확도가 높았으며 이에 따라 실제 수중에서의 콘크리트의 강도를 추정하고자 할 때 활용 가능성도 높아질 것으로 예상된다.

Development and Application of Dry Process Caisson for Maintenance of Submerged Barber Structure

  • Lee, Joong-Woo;Lee, Seung-Chul;Oh, Dong-Hoon;Kwak, Seung-Kyu;Lee, Jeong-Su
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 Asia Navigation Conference
    • /
    • pp.105-114
    • /
    • 2006
  • Together with the trend of enhancement in domestic industrial development and economic progress due to import and export, the demand for construction of the roads, bridges, especially port facilities, and several coastal protection and ocean structures is increasing rapidly. MOMAF of Korean Government is driving construction of 9 new ports and renovation of the existing fishery ports. Among these structures most of bridge base, wharves, dolphins, quays, and jetties are being newly built of steel or concrete pile. As the base, supporting bulkheads, and piles are underwater after construction, it is difficult to figure out the status of structures and not enough to get maintenance and strengthen the structures. Every year, moreover, these works suck the government budget due to higher incomplete maintenance expense for protection from corrosions of structures and increased underwater construction period. for the purpose of cutting down the government budget, it is necessary to extend the life cycle of the existing structures. We developed a new method for maintenance of submerged structures near the waterline by allowing dry work environment with the floating caisson. The method shows easy to move around the working area and handle. It also showed not only a significant reduction of maintenance expenses and time for anti-corrosion work but also better protection. This will be a milestone to reduce the maintenance and construction expenses for the shore and water structures.

  • PDF

콘크리트 수리구조물의 수중마모저항성 평가기술에 관한 실험적 연구 (Experimental Study on Evaluation of Abrasion Resistance of Concrete Irrigation Facilities)

  • 김명원
    • 한국농공학회논문집
    • /
    • 제60권3호
    • /
    • pp.123-133
    • /
    • 2018
  • The purpose of this paper is to propose an experimental method to evaluate the resistance of abrasion about 24 MPa, 27 MPa, and 30 MPa compressive strength. These strength are used in the design and construction of concrete hydraulic structures in Korea. The mixing ratios of the ready mixed concrete strengths were investigated countrywide and set the representative mixture proportion ratios of the nine mixed types of OPC, FA and BFS. After making and curing the test specimens, the underwater abrasion test was performed. ASTM C 1138 International Standard was used to fabricate the test equipment, and the surface abrasion resistance of the specimen was tested using the test equipment. In the case of OPC, the 30% abrasion resistance improvement effect was observed at 72 hours as the water-binder ratio decreased. That was reason the coated cement bond strength of the specimen was strong. In the case of BFS and FA, it was improved by 9.9% and 3.8%, respectively, at 72 hours as the water-binder ratio decreased. It was due to the characteristics of the latent hydraulic and pozzolanic reactions. Generally, the relative abrasion resistance of concrete can be evaluated at 24 hours. However, in case of low strength (under 24 MPa), the surface mortar layer wears much faster at the first 12 hours, so it can be considered to evaluate the relative abrasion loss rate at this point.

폴리머 디스퍼션을 이용한 프리팩트 콘크리트용 주입 모르타르의 배합에 관한 연구 (Mix Design of Polymer Grouting Mortar for Prepacked Concrete Using Polymer Dispersions)

  • 조영국;김완기
    • 한국건축시공학회지
    • /
    • 제8권5호
    • /
    • pp.85-91
    • /
    • 2008
  • Prepacked concrete has recently been used in the special constructions fields such as underwater concrete work, heavy-weight concrete work, underground structure work, partial repair works for damaged reinforced concrete structures. and polymer-modified mortars have been employed as grouting mortars for the prepacked concrete. The purpose of this study is to recommend the optimum mix design of polymer-modified grouting mortars for prepacked concrete. Polymer-modified mortars using SBR and EVA emulsions as admixture of grouting mortars for prepacked concrete are prepared with various mix proportions such as sand-binder ratio, fly ash replacement ratio, polymer-binder ratio. and tested for flowability, viscosity of grouting mortars, bleeding ratio, expansion ratio, flexural and compressive strengths of grouting mortars and compressive and tensile strengths of prepacked concretes. From the test results, it is apparent that polymer-modified mortars can be produced as grouting mortars when proper mix design is chosen. We can design the mix proportions of high strength mortars for prepacked concrete according to the control of mix design factors such as type of polymer, polymer-binder ratio, sand-binder ratio and fly ash replacement ratio. Water-binder ratio of plain mortars for a constant flowability value are in the ranges of 43% to 50%. SBR-modified mortar has a little water-binder ratios compared to those of plain mortar, however, EVA-modified mortar needs a high water-binder ratio due to a high viscosity of polymer dispersion. The expansion and bleeding ratios of grouting mortars are also controlled in the proper value ranges. Polymer-modified grouting mortars have good flexural. compressive and tensile strengths, are not affected with various properties with increasing fly ash replacement to cement and binder-sand ratio. In this study, SBR-modified grouting mortar with a polymer-binder ratio of 10% or less, a fly ash replacement of 10% to cement and a sand-binder ratio of 1.5 is recommended as a grouting mortar for prepacked concrete.

수중 항만구조물의 유지보수를 위한 건식 케이슨 공법 개발 (Development of Dry Process Caisson Method for Maintenance of Submerged Harbor Structure)

  • 이중우;오동훈;곽승규;김성태
    • 한국항해항만학회지
    • /
    • 제30권6호
    • /
    • pp.447-455
    • /
    • 2006
  • 근래 국내 산업의 고도화와 수출입 증가에 따른 경제력의 상승과 함께 도로, 교량 및 항만시설의 확충과 각종 호안 및 해상구조물의 건설요구가 급증하고 있다. 해양수산부는 9대 신항만의 건설과 기존어항의 재개발을 추진하고 있다 이들 구조물의 대부분은 교각기초, 안벽, 돌핀, 안벽, 돌제 등은 강재나 콘크리트 파일로 새롭게 건설되고 있다. 이들 기초, 지지격벽 및 파일은 건설 후에 수면아래에 있게 되므로 구조물의 상태를 파악하기가 어렵고, 그 구조물의 보수나 보강이 충분하지 못한 상태이다. 더구나 매년 이러한 유지 보수작업은 구조물의 부식을 방지하기 위한 불완전한 보수와 수중공사로 인한 장기작업으로 고비용 때문에 정부의 예산을 소진하게 된다. 이와 같은 정부예산의 지출을 절감하기 위해서는 기존 구조물의 내구연한을 연장시킬 필요가 있는 것이다. 그러므로, 부유식 케이슨으로 건식작업환경을 제공함으로써 평균해수면 수중구조물의 유지를 위한 새로운 기법을 개발하였다. DCPM은 작업구간을 쉽게 이동하고 취급이 용이한 것으로 나타났다. 또한 DCPM은 유지보수비용 및 방식작업 시간을 현저하게 줄였다. DCPM은 해안 및 수중구조물의 유지와 건설비용을 줄이는 이정표가 될 것으로 본다.

수중 항만구조물의 유지보수를 위한 건식 케이슨 공법 개발 (Development of Dry Process Caisson Method for Maintenance of Submerged Harbor Structure)

  • 이중우;오동훈;곽승규;김성태
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 춘계학술대회 및 창립 30주년 심포지엄(논문집)
    • /
    • pp.163-170
    • /
    • 2006
  • 근래 국내 산업의 고도화와 수출입 증가에 따른 경제력의 상승과 함께 도로, 교량 및 항만시설의 확충과 각종 호안 및 해상구조물의 건설요구가 급증하고 있다. 해양수산부는 9대신항만의 건설과 기존어항의 재개발을 추진하고 있다. 이들 구조물의 대부분은 교각기초, 안벽, 돌핀, 안벽, 돌제 등은 강재나 콘크리트 파일로 새롭게 건설되고 있다. 이들 기초, 지지격벽 및 파일은 건설 후에 수면아래에 있게 되므로 구조물의 상태를 파악하기가 어렵고, 그 구조물의 보수나 보강이 충분하지 못한 상태이다. 더구나 매년 이러한 유지 보수작업은 구조물의 부식을 방지하기 위한 불완전한 보수와 수중공사로 인한 장기작업으로 고비용 때문에 정부의 예산을 소진하게 된다. 이와 같은 정부예산의 지출을 절감하기 위해서는 기존 구조물의 내구연한을 연장시킬 필요가 있는 것이다. 그러므로, 부유식 케이슨으로 건식작업환경을 제공함으로써 수선부근에서의 수중구조물의 유지를 위한 새로운 기법을 개발하였다. 개발한 방법은 작업구간을 쉽게 이동하고 취급이 용이한 것으로 나타났다. 또한 기 기법은 유지보수비용 및 방식작업 시간을 현저하게 줄이는 것은 물론 보다 나은 방식을 제공하는 것으로 나타났다. 이 기술은 해안 및 수중구조물의 유지와 건설비용을 줄이는 이정표가 될 것으로 본다.

  • PDF

수중운항체에 대한 해중터널의 충돌해석 (Collision Analysis of Submerged Floating Tunnel by Underwater Navigating Vessel)

  • 홍관영;이계희
    • 한국전산구조공학회논문집
    • /
    • 제27권5호
    • /
    • pp.369-377
    • /
    • 2014
  • 본 논문에서는 해중터널와 수중운항체의 충돌거동을 파악하기 위하여 두 구조체를 모델링하고 해석을 수행하였다. 충돌이 일어나는 해중터널은 원통형으로 단면을 가정하고 콘크리트와 라이닝강판을 가진 구조로 가정하였다. 충돌부위를 제외한 인접부분은 탄성거동을 하는 보요소로 모델링하고 계류라인은 장력을 받는 케이블로 모델링하였다. 수중운항체는 1800톤급 잠수함을 가정하였으며 수리동역학적 부가질량을 고려하여 충돌질량을 산정하였다. 해중터널에 작용하는 부력은 동적완화방법을 사용하여 초기조건에 포함시켰다. 부력비의 변화와 충돌속도의 변화를 고려하여 충돌해석을 수행한 결과, 충돌에너지의 소산은 주로 해중터널에서 발생하고 수중운항체에 의한 에너지 소산은 미미한 것으로 나타났다. 또한 계류라인의 장력과 부력비의 변화에 따라 해중터널의 충돌거동은 큰 영향을 받았다. 특히 충돌력은 기존의 설계기준의 선박충돌력과는 상이한 경향을 보이는 것으로 나타났다.