• Title/Summary/Keyword: Underground station

Search Result 315, Processing Time 0.027 seconds

A by-pass rainwater penetration sewer system for urban flooding mitigation (도시침수 저감을 위한 by-pass 빗물침투성 우수관거)

  • Lee, Bum-Sub;Ko, Keon-Ho;Kang, Ho-Yeong;Moon, Young-Il
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.9
    • /
    • pp.799-807
    • /
    • 2016
  • The aim of this study is to determine and propose the by-pass rainwater sewer system in order to reduce the urban floodplain from the locality heavy rain every year during the dry season and the sinkholes in the city as well as the shortage of groundwaters due to extreme hot weather condition and urban heat island phenomenon. Heavy rain occurs more than the years of heavy rainfall probability, comparison between the place where uses the existing pipes and connect the sewer system with by-pass rain permeability and without expanding sewer pipe replacement at intersection of Gangnam station 3.07 ha at Gangnam-gu, Seoul Metropolitan area, it indicates that average of 27 million KRW (44%) maintenance cost savings and maintain existing sewer system without any other countermeasures. For the city flooded reduction, by-pass rainwater permeable rainwater pipe multiplying the probability the number of years during summer season and increase the water flow capacity during spring and fall when a small amount of rain that, it also contribute to the total amount of underground water secured through the by-pass penetration.

Slotted ALOHA Random Access with Multiple Coverage Classes for IoT Applications (사물인터넷 응용을 위한 다중 커버리지 클래스를 지원하는 슬롯화된 알로하 랜덤 접속)

  • Kim, Sujin;Chae, Seungyeob;Cho, Sangjin;Rim, Minjoong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.3
    • /
    • pp.554-561
    • /
    • 2017
  • IoT (Internet of Things) devices are often located in environments where indoor or underground, signals are difficult to reach. In addition, the transmission power is low, the base station should be designed to be able to receive signals even at low reception sensitivity. For this reason, a device having a poor channel condition can be transmitted at a low data rate using a low coding rate or repetition. When the coverage class is divided according to the channel condition and the data rate, the packet length may vary from one coverage class to another, and the performance of the slotted aloha random access may be degraded. We will focus on two methods of using shared-resource and seperate resources among multiple slotted aloha methods. In particular, when devices with different coverage classes use shared resources, performance of a device with a bad channel condition may deteriorate. Conversely, when using separate resources for each coverage class, there is a problem that congestion may occur which increases the number of devices that perform random access to one resource area. In this paper, we propose some methods to overcome this problem. This study is mainly focused on MTC devices, and is considered to be a high possibility of future development.

Study on the optimal design of floor exhaust system using computational fluid dynamics for subway platform (수치해석을 활용한 승강장 바닥배기 시스템 최적화 연구)

  • Namgung, Hyeong-Gyu;Park, Sechan;Kim, Minhae;Kim, Soo-Yeon;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.443-449
    • /
    • 2017
  • The imbalance of air supply and the exhaust on subway platforms has led to the installation of platform screen doors in underground subway stations. This imbalance causes the accumulation of pollutants on the platform and loss of comfort due to the lack of ventilation. In this study, a floor exhaust system was optimized using computational fluid dynamics (CFD) and an optimization program. The optimized floor exhaust system was manufactured and tested experimentally to evaluate the particle collection efficiency. CFX 17.0 and HEEDS were used to analyze the flow field and optimize the principal dimensions of the exhaust system. As a result of the three-step optimization, the optimized floor exhaust system had a total height of 1.78 m, pressure drop of 430 Pa, and particle collection capability of 61%. A fine dust particle collection experiment was conducted using a floor exhaust system that was manufactured at full scale based on the optimized design. The experiment indicated about 65% particle collection efficiency. Therefore, the optimized design can be applied to subway platforms to draw in exhaust air and remove particulate matter at the same time.

Studies on the Environmental Factors Affecting Growth and Tuber Formation of Eleocharis kuroguwai Ohwi (올방개(Eleocharis kuroguwai Ohwi)의 생장(生長)과 괴경형성(塊莖形成)에 미치는 환경요인(環境要因))

  • Ku, Y.C.;Choung, S.G.
    • Korean Journal of Weed Science
    • /
    • v.13 no.1
    • /
    • pp.44-54
    • /
    • 1993
  • This experiment was conducted to understand the environmental factors affecting growth and tuber formation such as temperature, day length, tight intensity, water condition and cutting time of Eleocharis kuroguwai Ohwi. Plant height, shoot number and dry weight of E. kuroguwai were higher at high temperature, 25/$25^{\circ}C$ (day/night), while nitrogen content was higher at low temperature, 20/$15^{\circ}C$. Plant height was more affected by water temperature, while shoot number and dry weight were more affected by air temperature. Contents and absorption of nitrogen, phosphorus, and potassium in top parts of E. kuroguwai were higher under greater difference between air and water temperatures, i.e., 18/$28^{\circ}C$ and 28/$18^{\circ}C$. The number and weight of tubers were increased under greater difference between air and water temperatures, i.e, 18/$28^{\circ}C$ and 28/$18^{\circ}C$, while they were inhibited at low or high air/water temperatures (18/$18^{\circ}C$ or 28/$28^{\circ}C$). Tubers of E. kuroguwai were formed at 8-or 12-hour day length, however, no tuber was formed at l6-hour day length. Photoinductive period for tuber initiation of E. kuroguwai was between 30 and 45 days after emergence, and the induction period of short-day treatment was less than 10 days. Tuber number and weight were reduced by shading due to inhibition of the growth of top and underground parts. Number of days from planting to tuber initiation was shortned as planting time was delayed and plant height, dry weight, and tuber number were also reduced by delayed planting. Tuber number at l0 to 15cm water depth was decreased 63 to 75% as compared with 1 to 5cm water depth. Tuber number and dry weight were not affected by the size of tubers at planting. Due to the reduced growth of top and underground parts, tuber number and dry weight of E. kuroguwai were decreased by delayed shoot cutting. The critical cutting time to inhibit the growth of E. kuroguwai was about 70 days after emergence.

  • PDF

Monitoring North Korea Nuclear Tests: Comparison of 1st and 2nd Tests (북한 핵실험 모니터링 : 1, 2차 비교)

  • Chi, Heon-Cheol;Park, Jung-Ho;Kim, Geun-Young;Che, Il-Young;Sheen, Dong-Hoon;Shin, Jin-Soo;Cho, Chang-Soo;Lee, Hee-Il
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.3
    • /
    • pp.243-248
    • /
    • 2010
  • Two suspicious events, which were claimed as underground nuclear tests by North Korea, were detected in the northern Korean Peninsula on October 9, 2006 and May 25, 2009. The KIGAM and Korea-China Joint seismic stations are distributed uniformly along the boundaries between North Korea and adjacent countries. In this study, the data from broadband stations with the distance of 200 to 550 km from the test site are used to analyze and compare two nuclear tests of North Korea. By comparing the time differences of the Pn-wave arrival times of 1st and 2nd tests at multiple stations, the relative locations of two test sites could be calculated precisely. From the geometrical calculation with the velocity of Pn wave $V_{Pn}$ = 8 km/s, the 2nd test site is estimated to move in the WNW direction from 1st one with the distance of 2 km. Body wave magnitude, mb of the 2nd test, which was announced officially as the network average of 4.5, varies widely with the directional location of stations from 4.1 to 5.2. The magnitude obtained from Lg wave, $m_b$(Lg), shows less variation between 4.3 to 4.7 with the average of 4.6. The moving-window spectra of time traces of 1st and 2nd tests show very similar pattern with different scale level. In addition, the corner frequencies of P wave of 1st and 2nd tests at each station show no or negligible difference. This indicates the burial depths of two tests might be very similar. The relative yield amount of the 2nd test is estimated 8 times larger than that of the 1st from the weighted average of ground-velocity amplitude ratios.