• Title/Summary/Keyword: Underground facilities

Search Result 636, Processing Time 0.022 seconds

Empirical Investigation and Comparative Analysis of Underground Public Pedestrian Facilities in Daegu Metropolitan City

  • Lee, Gahng-Ju;Jung, Seong-Hwan
    • Architectural research
    • /
    • v.15 no.2
    • /
    • pp.95-102
    • /
    • 2013
  • The study establishes the analytical frame composed of 22 items according to the category of passageway, shop, entrance and amenity for the purpose of executing the empirical investigation of the Underground Public Pedestrian Facilities in Daegu Metropolitan City of Korea. As a result of the research work, the study finds out some problems about the facilities as follows: (1) Passageway elements - the skylight was constructed only in one place. In contrast, the standards of passageway and plaza were well-fulfilled except for one or two cases. (2) Shop elements - the cases of installing shops where they should not be located were found the most, and a case of over-establishing the shop area was found as well. (3) Entrance elements - the cases not matching roof or canopy standard over entrance facilities were found the most. Overall, the entrances and their connection to the adjacent buildings are appraised as not well-established. (4) Amenity elements - these were appraised as insufficient in all except two cases. Regarding this, not only necessary are the establishment of facilities and the effort of facility managers, but also urgent is the institutional improvement.

A Study on the Eco-friendly, Sustainable Underground Campus Plan - Based on the Case Study and User Satisfaction Research - (지속가능한 친환경 지하캠퍼스 계획 방향에 관한 연구 -사례분석과 이용자 만족도 조사를 중심으로-)

  • Chung, Jae-Hee;Lee, Sang-Yun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.17 no.6
    • /
    • pp.13-22
    • /
    • 2010
  • This study aims to propose design directions for the eco-friendly, sustainable underground campus in terms of integrated design. For this purpose, theoretical investigation, design methodology and quality investigation, analytical case studies on the domestic and foreign underground campus, and user survey for POE(Post Occupancy Evaluation) and analysis on the recently built domestic underground campus plans were conducted. As a conclusion, design direction and improvement areas for the synthesized sustainable underground campus plan were proposed. Underground campus plan will be a great alternative for a 21st century sustainable campus if well-developed plans with organized design guidelines are established.

Improvement on Surveying Performance Evaluation for Public Surveying of Underground Facilities (지하시설물의 공공측량 성과심사 방법 개선에 관한 연구)

  • Jung, Choong Ho;KIM, Chong-Mun;KIM, Ki-Su;CHOI, Yun-Soo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.2
    • /
    • pp.15-23
    • /
    • 2019
  • When the public surveying system was introduced in 1961, large scale surveying performances, such as infrastructure construction work, were dominant. However, due to changes in the environment, most of the current surveying performances focused on small scale underground facilities. The method of surveying underground facilities is as follows: "method of measurement before refilling after burying the pipeline" and "method of using exploration after refilling." There are advantages and disadvantages to each method. It became difficult to obtain the accuracy of the location of the underground facilities due to the fact that there were sections of the pipeline that had not been observed through exploration. Therefore, the 2017 performance evaluation regulations were revised. The revision included the addition of the "Underground Facilities Creation Period," a system that allows for surveys to be evaluated based on actual measurements. However, in this particular field, concerns about the advantages of exploration and the purpose of this study was to investigate the background and purpose of the limitations of the survey have been continuously raised. The purpose of this study was to investigate the background and purpose of the public surveying system and to identify the proportion of underground facilities surveying in comparison to public surveying. This study conducted surveys on the implementers of public surveying and those who did the actual surveying. The researcher has summarized the improvements that incorporate the analysis results and the field comments in the revised performance evaluation regulations in 2017.

Investigation of Health Hazards in the Underground Storage Facilities of Ginger Roots (생강 저장굴에서 발생한 건강 피해의 원인 조사)

  • Bae, Geun-Ryang;Lim, Hyun-Sul
    • Journal of Preventive Medicine and Public Health
    • /
    • v.35 no.1
    • /
    • pp.72-75
    • /
    • 2002
  • Objectives : To evaluate the health hazards in the underground storage facilities of ginger roots. Methods : The authors reviewed the emergency rescue records from the Seosan fire department over the period Jan 1, 1996 to Aug 31, 1999. The atmospheres in 3 different underground storage locations were analyzed for $O_2,\;CO_2,\;CO,\;H_2S\;and\;NH_4$. Results : From the emergency records, we were able to identify 20 individuals that had been exposed to occupational hazards in the underground storage facilities. Among these 20 cases, 13 were due to asphyxiation (resulting in f deaths) and 7 were due to falls. In the first atmospheric tests, peformed on Feb 25, 1998, the O2 level inside the underground storage facility, located about $5{\sim}6$ meters below the surface, was 20.6% and the $CO_2$ level was about 1,000 ppm. CO, $H_2S\;and\;NH_4$ were not detected. In the second tests on Jul 6, 1999, measurements of the $O_2$ level at 3 meters below the surface in two different storage locations were 15.3 and 15.1%. And the $O_2$ levels inside the storage facilities were 12.2 and 12.1%. The $CO_2$ level was above 5,000 ppm (beyond upper limits of measurement). CO, $H_2S\;and\;NH_4$ were not detected. Conclusions : We conclude that asphyxiation in the underground storage facilities for ginger roots was not due to the presence of toxic gases such as CO, $H_2S\;and\;NH_4$, but rather the exclusion of oxygen by carbon dioxide was responsible for causing casualties. For the development of a hazard free working environment, safety education as well as improvements in storage methods are needed.

Revision of related Regulations and Construction Standards for the Use of Information on Underground Facilities Quality Level (지하시설물 품질등급 정보의 활용을 위한 관련 규정 및 건설기준 개정 방안)

  • Park, Joon Kyu;Kim, Tae Hoon;Kim, Won Dae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.4
    • /
    • pp.343-350
    • /
    • 2022
  • The computerization project for underground facilities in Korea began in earnest after the city gas explosion in Seoul in 1994, and the Daegu subway explosion in 1995. As such a large-scale gas explosion accident caused enormous economic loss including human casualties and potential benefits, the need for computerized for efficient management of underground facilities was greatly emphasized in society. Meantime, computerization of underground facilities has been carried out according to the basic plan for building national geographic information system. In this study, problems were identified based on the current status of construction and management of underground facility information, as well as laws and regulations, and directions for establishing quality standards were presented. In addition, construction work standards such as 「Public Survey Work Regulations」, design standards, standard specifications, and technical specifications, gas technology standards, design standards, and communication works so that underground facility information can be linked and utilized in construction work by examining the linkage of the underground facilities, the targets that can be used for quality level information on underground facilities were derived, and a proposal to revise the construction standards was presented. In the future, if the quality standards are established, it is expected that the accuracy and utilization in the construction field will be increased.

Research on Improving Quality Management for Underground Space Integration Map - Focusing on pipe-type underground facilities - (지하공간통합지도 품질관리 개선방안 연구 - 관로형 지하시설물을 중심으로 -)

  • Bae, Sang-Keun;Kim, Sang-Min;Yoo, Eun-Jin
    • Journal of Cadastre & Land InformatiX
    • /
    • v.50 no.2
    • /
    • pp.221-235
    • /
    • 2020
  • The development and utilization of underground spaces are increasing as the use of land based on ground surface became limited due to rapid urbanization triggered by population growth and industrialization. Despite its merit of efficient use of limited land and space, it may contribute to occurrence of various disasters such as sinkholes and damage to underground facilities. After the sinkholes formed and occurred across the country in 2014, there has been an effort to establish Underground Space Integration Map containing 15 types of underground information. Still, there is an increasing demand to improve the quality of underground information stemmed from continuation of such events including the rupture of the hot water pipe in Goyang-si and the fire in the KT site in Ahyeon-dong, Seoul. Hereby, with the aim to improve the quality of Underground Space Integration Map, this study analyzes quality standards, regulations, and guidelines related to spatial data to improve quality inspection standards and methods included in the production rules for the Underground Space Integration Map. In particular, it suggests improvement plan for data quality management for pipe-type underground facilities, known as lifelines, which are essential part of daily life of the citizens, and the largest cause for accidents according to 15 types of underground information managed through the Underground Space Integration Map.

Constrution and Application of Underground Facilities Survey System using the 3D Integration Map of Underground Geospatial Information (3차원 지하공간통합지도를 활용한 지하시설물 현장 측량 시스템 구축 및 적용)

  • SONG, Seok-Jin;CHO, Hae-Yong;HEO, Hyun-Min;KIM, Sung-Gil
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.24 no.4
    • /
    • pp.164-173
    • /
    • 2021
  • Recently, as underground space safety issues such as sink hole, ground subsidence and damage to old underground facilities have been increasing in urban areas, the precise management of underground facilities ins more required. Thus, this study developed a function to that, visualize on Integration Map of Underground Geospatial Information a real-time survey data of underground facilities acquired on site or underground facility survey data acquired through on-site survey after underground facility exploration and developed a function convert to surveying-results. In addition, using the on-site survey performance utilization function in connection with the Integration Map of Underground Geospatial Information developed through this study, the surveying -results obtained with the Total-station at the water pipeline burial construction site in Eunpyeong-gu, Seoul are visualized on the Integration Map of Underground Geospatial Information and On-site verification was performed by converting spatial-information performance files and transmitting the Integration Map of Underground Geospatial Information to the mobile center. Based on this, it was possible to verify the work procedure using the surveying-results in the area where the Integration Map of Underground Geospatial Information was built, and to review the direction of future improvement directions.

Basic Study on Logical Model Design of Underground Facilities for Waterworks (상수도 지하시설물의 논리적 모델 설계에 관한 기초 연구)

  • Jeong, Da Woon;Yu, Seon Cheol;Min, Kyung Ju;Lee, Ji Yeon;Ahn, Jong Wook
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.533-542
    • /
    • 2020
  • This study proposes the logical data model design of a spatial data model that complies with international standards for the waterworks of underground facilities. We conduct a preliminary study related to underground spatial data standards and data models, and review the status of the existing systems. Then, we defined the conceptual design direction of underground spatial data model based on the problems and issues. Next, we defined the terminology, classification, semantic relationships of waterworks. Next, for the conceptual design of the underground spatial data model, we defined the naming criteria for all data according to the waterworks classification. In addition, a logical model is drawn and described using UML (Unified Modeling Language) diagrams. Based on the results, it is expected that the accuracy related to underground facilities data will be improved.

Updated Object Extraction in Underground Facility based on Centroid (중심점 기반 지하시설물 갱신객체 추출 기술)

  • Kim, Kwagnsoo;Lee, Kang Woo;Kim, Bong Wan;Jang, In Sung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.553-559
    • /
    • 2020
  • In order to prevent subsidence in urban areas, which is a major cause of damage to aging underground facilities, an integrated underground space map is being produced for systematic management of underground facilities. However, there is a problem of delaying the update time because an unupdated underground facility object is included in the process of updating the underground space integrated map. In this paper, we proposed a method to shorten the update time of the integrated map by selecting only the updated objects required for the update process of the underground space integrated map based on the central point of the underground facilities. Through the comparison of the centroid, the number of search targets is greatly reduced to shorten the search speed, and the distance of the actual location values between the two objects is calculated whether or not the objects are the same. The proposed method shows faster performance as the number of data increases, and the updated object can be reflected in the underground space integrated map about four times faster than the existing method.

A Study on Facility Information System using GIS and Semantic Web in Underground Space

  • Cui, Yulan;Hwang, Hyun-Suk;Kim, Chang-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.12
    • /
    • pp.1843-1854
    • /
    • 2010
  • The utilization of underground space has recently increased with the complication of road, the rise of the land price, and the development of green technology. Underground space ranges from classical excavations to subway, underground cities, and shopping malls where there are crowds of people. At this time, government has spent a lot of money in installing various types of safety facilities for preparations of increasing potential disasters. Therefore, an effective facility management system is required. In this paper, we propose an information retrieval process to effectively extract the facilities' information based on the ontology and spatial analysis in underground space. The ontology-based searching supports hierarchical and associated results as well as knowledge sharing with hierarchy concepts. The spatial analysis based searching has "Buffer" and "Near" functions to operate on a map without understanding any property of the facility information.