• Title/Summary/Keyword: Underground Waterproofing

Search Result 82, Processing Time 0.026 seconds

Analysis of underground post-tensioned precast concrete box utility tunnel under normal fault displacement

  • Wu, Xiangguo;Nie, Chenhang;Qiu, Faqiang;Zhang, Xuesen;Hong, Li;Lee, Jong-Sub;Kang, Thomas H.K.
    • Computers and Concrete
    • /
    • v.29 no.2
    • /
    • pp.69-79
    • /
    • 2022
  • For long underground box utility tunnels, post-tensioned precast concrete is often used. Between precast tunnel segments, sealed waterproof flexible joints are often specified. Fault displacement can lead to excessive deformation of the joints, which can lead to reduction in waterproofing due to diminished contact pressure between the sealant strip and the tunnel segment. This paper authenticates utilization of a finite element model for a prefabricated tunnel fault-crossing founded on ABAQUS software. In addition, material parameter selection, contact setting and boundary condition are reviewed. Analyzed under normal fault action are: the influence of fault displacement; buried depth; soil friction coefficient, and angle of crossing at the fault plane. In addition, distribution characteristics of the utility tunnel structure for vertical and longitudinal/horizontal relative displacement at segmented interface for the top and bottom slab are analyzed. It is found that the effect of increase in fault displacement on the splice joint deformation is significant, whereas the effects of changes in burial depth, pipe-soil friction coefficient and fault-crossing angle on the overall tunnel and joint deformations were not so significant.

A Study on the Swelling Property of Bentonite Mat under Salt Water Condition (담수환경하에 노출된 일반 벤토나이트 매트재의 팽윤성능 평가)

  • 양승도;김영삼;유재강;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.81-84
    • /
    • 2002
  • Recently Bentonite mat is applied various structure : External waterproofing for underground structure, A reclaimed land, Artificial lake, Large-scaled civil structure, etc. With these various structure environment, water quality for application of Bentonite Mat affects watertightness. Specially spot with a large quantity of Chloride ion like salt water, degree of watertightness revelation is evaluated and applied. In this study, it is a main goal to investigate watertightness of Bentonite Mat with distilled water and salt water dissolved chloride ion Contents 0.88%. The result of this paper is as follows. 1) Water permeability coefficient of Bentonite Mat : distilled water(1.21$\times$10$^{-9}$cm/sec), salt water(3.12$\times$10$^{-7}$cm/sec). 2) Variation of thickness : distilled water(187%), salt water(108%). 3) Swelling ratio : distilled water(1500%), salt water(350%).

  • PDF

A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Cracks Repairing Material using on the Underground Structure (지하구조물에 적용하는 누수균열 보수용 방수씰의 성능평가 방법에 관한 연구)

  • Kwon Shi Won;Kwon Kee Joo;Lee Jong Yong;Oh Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.652-655
    • /
    • 2004
  • In these days, repair materials for leakage cannot help but being taken in temporary way without any noticeable countermeasure. This kind of repair is socially criticized many times that is defective construction even if tills costs a lot. It was not arrange the standard for performance evaluation test method and quality maintenance for materials, even it has been used various injection repairing agent. In conclusion, We suggest that the test method for repair materials for leakage to establish the leakage repairing technology as increase of structure demand, so that the necessity of the establishment of the quality control standard and the performance testing way on the relevant water-proof seal is increasing a lot to regulate the water-proof technology and the leakage repair technology.

  • PDF

Reconsideration of Waterproofing and Rootproofing to keep Durable Safety of Concrete Structure in the Greening System (콘크리트 구조물 기반 녹화 공사에 있어서 콘크리트의 내구안전성 확보를 위한 방수 및 방근 기술의 제고)

  • Oh, Sang-Keun;Kim, Hyeon-Soo;Kim, Young-Geun;Kwon, Shi-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.927-930
    • /
    • 2008
  • Recently, the scale and form of the construction promoting in government and private organization have large scaled town. The underground area of whole town are used for every facilities, and most of concrete area are used for greening part for friendly environment construction. This greening part for concrete area have good point such as being amendment and various economical effect and improvement for environmental problem, moreover, the amount of greening part become great increased. For this factor, we have to newly consider to keep durable safety for concrete structure, therefore, we suggest that how to keep structural safety of greening area on the concrete.

  • PDF

The Effects of Activities and Working Conditions on Fire Accidents on Construction Sites

  • Yi, Kyoo-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.4
    • /
    • pp.383-389
    • /
    • 2020
  • Accidents on construction sites involving fires do not occur as often as accidents involving falls from height or collapses. However, once a fire accident occurs, there is a high risk of a large number of casualties. Fire on construction sites is affected by working conditions and the types of activities the construction workers are engaged in at the sites. This study aims to identify activities and working conditions at construction sites that are vulnerable to fire, and analyse how they correlate with each other and how they affect the causes and consequences of fire accidents at construction sties. I analysed 40 fire accident reports and listed the situations vulnerable to fire at construction sites considering direct causes, activities, and working conditions. The most dangerous combination of fire hazards can be the heating devices used during rest/sleep in the office/cabin/storage during cold weather. The next most hazardous combination can be sparks arising from painting, waterproofing, insulation, plumbing, or welding/melting work in an underground or confined space.

Information Network Usage Plan for the Quality Control of Leakage Prevention (누수예방을 위한 품질확보 관련 정보공유시스템의 활용방안의 관한 연구)

  • Kang, Hyo-Jin;An, Ki-Won;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.217-218
    • /
    • 2017
  • Residential apartment underground structures are being utilized for many purposes such as parking lots, community centers, fitness centers, etc. for efficient use of space. However, there are increasing problems of leakage due to various environmental and deterioration conditions. This paper proposes the development of an information network system which can serve as a base to provide solutions, alternatives and technical information for leakage prevention and effective design at the beginning of the construction stage.

  • PDF

Evaluation of Mechanical Performance of a Segment Lining coated by a Sprayed Waterproofing Membrane by a Full-scale Loading Test (실물 재하실험에 의한 뿜칠 방수 멤브레인이 타설된 세그먼트 라이닝의 역학적 성능 평가)

  • Kang, Tae-Ho;Choi, Soon-Wook;Lee, Chulho;Park, Byungkwan;Kim, Jintae;Choi, Myung-Sik;Chang, Soo-Ho
    • Tunnel and Underground Space
    • /
    • v.28 no.1
    • /
    • pp.97-110
    • /
    • 2018
  • The application of sprayed waterproofing membrane with high adhesion and ductility is considered to be promising as a measure for repair and reinforcement of a tunnel structure. Therefore, a powder-type and one-component membrane prototype with high tensile and bond strengths was made in this study. Then, its reinforcement effect on a shield segment was evaluated by carrying out a series of full-scale loading tests of segment specimens on which the membrane was sprayed. From the tests, it was confirmed that the initial cracking loads increased by approximately 34% due to cracking retardation by membrane coating. Even though the increase of failure loads were not so high as cracking loads, the strain-softening behaviors were observed from specimens coated by the membrane. Therefore, it is expected that the membrane coated on the inner surface of a lining might be effective in preventing its brittle failure.

Experimental Study on the Characteristics of Asphalt Seal Waterproofing Material for Underground External Walls According to Temperature (온조도건에 따른 외벽방수용 아스팔트 씰계 재료의 흘러내림 특성에 관한 실험)

  • Um, Tae-Ho;Kim, Young-Sam;Shin, Hong-Chul;Cho, Jae-Woo;Kim, Young-Geun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.1-5
    • /
    • 2018
  • The present study investigated the characteristics of vertical sagging down of high temperature in chamber and characteristics of vertical sagging down in the outdoor asphalt sheet and asphalt seal under korea ltimate condition using asphalt seal products of solvent based type, solventless type, water dispersion type, and heat melting type, which are currently applied in Korea. Prior to the investigation of outdoor vertical sagging down characteristics, the assessment of sagging down performance of single use of sealing products at $20^{\circ}C$, $40^{\circ}C$, $60^{\circ}C$ was conducted and the result showed that sagging down did not occur at $20^{\circ}C$ but some solventless type, water dispersion type specimens at $40^{\circ}C$ had sagging down up to 10 mm. In addition, some solventless type, water dispersion type specimens had sagging down up to 55 mm at $60^{\circ}C$. For specimens to which asphalt seal and renovated asphalt sheet were layered over the outdoor concrete vertical surface, sheet sagging and sagging down occurred up to 50 mm in water dispersion specimens after three month later since the construction in summer.

A fundamental study of slurry management for slurry shield TBM by sea water influence (해수의 영향에 따른 이수식 TBM의 슬러리 관리를 위한 기초적 연구)

  • Kim, Dae-Young;Lee, Jae-won;Jung, Jae-Hoon;Kang, Han-Byul;Jee, Sung-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.463-473
    • /
    • 2017
  • Bentonite swells when it comes into contact with water and makes it a viscous fluid. Thus it is widely used in civil engineering works for waterproofing. Utilizing the properties of bentonite, the slurry shield TBM supports excavated face with pressurized slurry as well as transporting excavated muck. When bentonite is in contact with seawater, due to the change of double layer thickness, its expandability and viscosity are lowered. This may cause problems for excavation stability and muck discharge due to the increase of sea water inflow when Slurry TBM is used under sea water conditions. In this study, the change of slurry condition caused by the inflow of sea water during tunnel excavation with Slurry TBM was investigated and a slurry management guideline was proposed. For this purpose, a laboratory test was carried out based on the slurry management criterions applied in the field, and a method applicable to the field where sea water is affected has been proposed.

Numerical study on contact behavior of TSL (Thin Spray-on Liner) (접촉 거동을 고려한 TSL(Thin Spray-on Liner)의 수치해석 연구)

  • Lee, Chulho;Chang, Soo-Ho;Lee, Kicheol;Kim, Dongwook
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.6
    • /
    • pp.665-674
    • /
    • 2015
  • A TSL (Thin Spray-on Liner) which consists of polymers has a higher initial strength, faster construction time and higher waterproofing performance than the conventional cementitious shotcrete. Main supporting mechanism of TSL is the adhesion and tensile strength which is distinct from the conventional shotcrete. Even though highly in demand due to its outstanding characteristics, TSL is not yet well-known support material. In this study, to evaluate contact behavior of TSL, numerical analysis was performed with comparing result from laboratory tests. From the analysis, cohesive behavior at the contact surface between TSL and rock can be evaluated by using combination of cohesive and the damage model. In addition, results show that the cohesive stiffness controled slope between force and displacement, the fracture energy controled level of force at the contact.