• 제목/요약/키워드: Underground Sound

검색결과 57건 처리시간 0.028초

파이프-유체의 연성진동을 이용한 누수위치 식별연구 (Pinpointing of Leakage Location Using Pipe-fluid Coupled Vibration)

  • 이영섭;윤동진
    • 한국소음진동공학회논문집
    • /
    • 제14권2호
    • /
    • pp.95-104
    • /
    • 2004
  • Leaks in underground pipelines can cause social, environmental and economical problems. One of relevant countermeasures against leaks is to find and repair of leak points of the pipes. Leak noise is a good source to identify the location of leak points of the pipelines. Although there have been several methods to detect the leak location with leak noise, such as listening rods, hydrophones or ground microphones, they have not been so efficient tools. In this paper, accelermeters aroused to detect leak locations which could provide an easier and more efficient method. Filtering, signal processing and algorithm of raw input data from sensors for the detection of leak location are described. A 120m-long and a 70m-long experimental pipeline systems are installed and the results with the systems show that the algorithm with the accelerometers offers accurate pinpointing for leaks location detection. Theoretical analysis of sound wave propagation speed of water in underground pipes, which is critically important in leak locating, is also described.

가속도계를 이용한 상수도 배관의 누수위치 식별연구 (Pinpointing of Leakage Location of Water Pipelines using Accelerometers)

  • 이영섭;윤동진;정중채
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.821-826
    • /
    • 2003
  • Leaks in underground pipelines can cause social, environmental and economical problems. One of a good contermeasures of leaks Is to find and repair of leak points of pipes. Leak noise is a good source to identify the location of leak points of pipelines. Although there have been several methods to detect the leak location with leak noise, such as listening rods, hydrophones or ground microphones, they were not so efficient tools beca. In this paper, two accelermeters are used to detect leak locations which could provide an easier and efficient method. The filtering, signal processing and algorithm is described for the detection of leak location. A 120m-long pipeline system for experiment is installed and the results with the system show that the algorithm with the two accelerometers gives very accurate pinpointing of leaks. Theoretical analysis of sound wave propagation speed in underground pipes is also described.

  • PDF

도시철도 역사개선에 관한연구 (A study on the subway-station improvement of metropolitan subway)

  • 김동원;박수중;이희성;문대섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1641-1646
    • /
    • 2007
  • Subway station is installed with equipment of deficient ventilation and air purification in need of routine activity for users because projectors didn't have recognition of the importance of prevention equipment on disasters in subway stations. So if the accident in Deagu is occurred again, we can't prevent it. And it is urgently necessary to improve antique subway station for the safety and service to citizens because users were increased far more. Improvement of subway station has to be modernized the backward and antique subway station and maintained and developed by the center of traffic to give the social contribution with management of social facilities. And subway station has to be made conveniently so that everyone may use the station with one-stop system including sales, business, service equipment. This study will show the improvement plan of problem in underground space and situation of metropolitan-train history to improve metropolitan-train station .we will study a traffic line and equipment relocation of underground space considering safety by choosing the improved station and problems of the underground station in seoul. And then we will study the improvement plan of air purification and sound isolation to upgrade service in citizens.

  • PDF

폐기물 소각시설 내부 소음에 관한 연구 (A Study on Noise in Waste Facilities)

  • 서병석;박노국;전용한
    • 대한안전경영과학회지
    • /
    • 제22권2호
    • /
    • pp.15-21
    • /
    • 2020
  • Industrial facilities need design to predict and reduce noise from design to prevent and reduce noise. The purpose of this study is to predict worker's environment and evaluate safety by analyzing noise inside underground blower room and air compressor room with fluid machinery in waste facility. This waste incineration facility was analyzed based on the ground floor, ground floor blower chamber, and air compressor chamber. The results of SPL(Sound Pressure Level) analysis at 1.5m away, which are frequently used to measure the SPL as a noise source, are as follows. SPL of basement level: 46.80[dB], SPL of ground layer: 48.57[dB]. As a result, it was expected that the noise level would be considerably lower than the 8 hours 50[dB] noise exposure per day.

지중매설 폴리에틸렌 관의 장기거동 예측 (Prediction of Long-Term behavior of polyethylene pipe buried underground)

  • 이재호;김빈;윤수현;김응호
    • 상하수도학회지
    • /
    • 제31권1호
    • /
    • pp.7-12
    • /
    • 2017
  • Most of existing buried pipes are composed of reinforced concrete. Reinforced concrete pipes have many problems such as aging, corrosion, leaking, etc. The polyethylene (PE) pipes have advantages to solve these problems. The plastic pipes buried underground are classified into a flexible pipe. National standard that has limited the long-term vertical deformation of the pipe to 5% for flexible pipes including PE pipe. This study presents a prediction for the long-term behavior of the polyethylene pipe based on ASTM D 5365. This prediction method is presented to estimate by using the statistical method from the initial deflection measurement data. We predict the behavior of long-term performance on the double-wall pipe and multi-wall pipe. As a result, it was found that the PE pipe will be sound enough more than 50 years if the compaction of soil around the pipe is more than 95% of the standard soil compaction density.

전산모형 및 공간정보시스템을 결합한 지하환경관리시스템의 개발 및 적용 (A Subsurface Environment Management System Combining Computational Model and Spatial Information System)

  • 김준현;한영한
    • 환경영향평가
    • /
    • 제10권2호
    • /
    • pp.99-108
    • /
    • 2001
  • This study was performed to develop an information processing system for the sound conservation of soil and groundwater resources. The system contains numerical models and geographic information systems for underground flow and contamination. Multidimensional Finite Element Model for Subsurface Environment (MFEMSE) was invented to analyze underground flow and pollution problems of water and gas phases. Newly developed and conventional models (MODFLOW, MOC3D, MT3D, PMPATH, PEST, UCODE) were integrated with GIS (ArcView) for the construction of an integrated information management system of subsurface environment. This system was applied to the management of three mineral water companies located in clean high mountain basin. Desirable management criteria and operational strategies were suggested using this system. The system was constructed to be applied for the broad sense of decision supporting tools in related topics of this study, so that it can be used not only for the prevention regulations, but also for clean up projects.

  • PDF

배관-유체 연성진동을 이용한 누수지점 탐지알고리듬 개발연구 (An Algorithm for Leak Locating using Coupled Vibration of Pipe-Water)

  • Lee, Yeong-Seop;Yun, Dong-Jin
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.985-990
    • /
    • 2004
  • Leak noise is a good source to identify the exact location of a leak point of underground water pipelines. Water leak generates broadband noise from a leak location and can be propagated to both directions of water pipes. This sound propagation due to leak in water pipelines is not a non-dispersive wave any more because of the surrounding pipes and soil. However, the necessity of long-range detection of this leak location makes to identify low-frequency acoustic waves rather than high frequency ones. Acoustic wave propagation coupled with surrounding boundaries including cast iron pipes is theoretically analyzed and the wave velocity was confirmed with experiment. The leak locations were identified both by the acoustic emission (AE) method and the cross-correlation method. In a short-range distance, both the AE method and cross-correlation method are effective to detect leak position. However, the detection for a long-range distance required a lower frequency range accelerometers only because higher frequency waves were attenuated very quickly with the increase of propagation paths. Two algorithms for the cross-correlation function were suggested, and a long-range detection has been achieved at real underground water pipelines longer than 300m.

  • PDF

전력선 통신을 이용한 재해 발생시 피난구 유도 제어장치 시스템 (A Shelter Guidance Control System from the Disaster using the PLC)

  • 엄기환;현교환;김주웅;정성부;김인국
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2005년도 하계학술대회
    • /
    • pp.92-96
    • /
    • 2005
  • 본 연구에서는 현재 지하공간에 설치되어 있는 기존의 피난구 유도등의 문제점을 개선하기 위하여 전력선 통신을 이용한 피난구 유도 제어장치 시스템을 제안하였다. 제안한 피난구 유도 제어장치 시스템은 주제어부, 전력선 통신 원격 제어부, 충전부, 음성발생부, 표시부, 경보알람부, 연기감지부 둥으로 구성된다. 제안한 전력선 통신을 이용한 피난구 유도 제어장치 시스템을 실험을 통하여 전력선 통신의 단점인 잡음을 개선하였으며, 기존의 피난구 유도등이 가지는 단점을 보완하는 것을 확인하였다.

  • PDF

PLC 통신을 이용한 피난구 유도장치 시스템 (A Shelter Guidance System using the PLC Communication)

  • 이창영;이규윤;이현관;김인국;엄기환
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 춘계종합학술대회
    • /
    • pp.583-586
    • /
    • 2005
  • 본 연구에서는 현재 지하공간에 설치되어 있는 기존의 피난구 유도등의 문제점을 개선하기 위하여 PLC 통신을 이용한 피난구 유도장치 시스템을 제안하였다. 제안한 피난구 유도장치 시스템은 주제어부, PLC 통신 원격 제어부, 충전부, 음성발생부, 표시부, 경보알람부, 연기감지부 등으로 구성된다. 제안한 PLC 통신을 이용한 피난구 유도 장치 시스템을 실험을 통하여 PLC 통신의 단점인 잡음을 개선하고 유용성을 확인하였다.

  • PDF

시간지연 추정을 통한 누수위치 식별 연구 (Time Delay Estimation for the Identification of Leak Location)

  • 이영섭;윤동진;김치엽
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.327-332
    • /
    • 2004
  • Leak noise is a good source to identify the exact location of a leak point of underground water pipelines. Water leak generates broadband noise from a leak location and can be propagated to both directions of water pipes. This sound propagation due to leak in water pipelines is not a non-dispersive wave any more because of the surrounding pipes and soil. However, the necessity of long-range detection of this leak location makes to identify low-frequency acoustic waves rather than high frequency ones. Acoustic wave propagation coupled with surrounding boundaries including cast iron pipes is theoretically analyzed and the wave velocity was confirmed with experiment. The leak locations were identified both by the acoustic emission (AE) method and the cross-correlation method. In a short-range distance, both the AE method and cross-correlation method are effective to detect leak position. However, the detection for a long-range distance required a lower frequency range accelerometers only because higher frequency waves were attenuated very quickly with the increase of propagation paths. Two algorithms for the cross-correlation function were suggested, and a long-range detection has been achieved at real underground water pipelines longer than loom.

  • PDF