• Title/Summary/Keyword: Underground Shopping Center

Search Result 39, Processing Time 0.028 seconds

Universal Design in Main Entrance Space of Underground Passage Shopping Center (지하도상가 주출입 공간의 유니버설 디자인 적용 현황에 관한 연구)

  • Lee, Hyo-Chang;Ha, Mi-Kyoung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.11a
    • /
    • pp.99-102
    • /
    • 2007
  • Underground passage shopping center which is one of the underground space is a public facility. Therefore, underground passage shopping center needs physical environment that everyone (such as ordinary adults, seniors, disabled and ETC) could use it without any difficulties. The purpose of this research is to evaluate the application of universal design into main entrance space of underground passage shopping center. The scope of this research was adjusted as 8 underground passage shopping centers that are located in Seoul. Spacial scope of the research was set as public space such as main entrance space, slope way, stairway of underground passage shopping center and the content of scope of this research was the application of universal design. The conclusion of this research is as following. First, public space of underground passage shopping center needs physical environmental improvement for the convenient usage for seniors and disabled. Second, the application of universal design is needed for public space for shelter and rescue of underground passage shopping center. Third, Underground passage shopping center needs a plan to minimize the safety infringement of user by commercial activity of stores in it.

  • PDF

A Study on Air Pollution and Thermal Factors in Underground Shopping Center of Pusan Area (부산시내 지하생활권의 공기오염도와 온열인자에 관한 조사연구)

  • Choi, Sung-Yong;Moon, Deog-Hwan;Lee, Jong-Tae;Song, In-Hyuk;Lee, Cha-Eun;Lee, Sung-Min
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.3 s.47
    • /
    • pp.505-516
    • /
    • 1994
  • For the purpose of preparing the fundamental data on air pollution in underground shopping center and also contributing to the health improvement of residents, the authors measured the level of $SO_2,\;NO_2,\;TSP,\;CO,\;CO_2$ and also some related factors as air temperature, air movement, relative humidity and mean radiation temperature at inside and outside of underground shopping center in Pusan from January to February and from July to August 1994. The results were as follows : 1. The mean concentration of CO within the underground shopping center was $3.1{\pm}1.3ppm$ in winter and $2.1{\pm}0.9ppm$ in summer. There was a negative correlation (p<0.01) between inner CO concentration and temperature in summer and no correlation between inner CO concentration and outer CO concentration in underground shopping center 2. The mean concentration of COE within the underground shopping center was $876{\pm}353ppm$ in winter and $757{\pm}125ppm$ in summer. There was a negative correlation (p<0.01) between inner $CO_2$ concentration and air movement in summer and positive correlation (p<0.05) between inner $CO_2$ concentration and outer $CO_2$ concentration in underground shopping center. 3. The mean concentration of $SO_2$ within a underground shopping center was $0.036{\pm}0.019ppm$ in winter and $0.040{\pm}0.013ppm$ in summer. There was a positive correlation(p<0.01) between inner $SO_2$ concentration and temperature in summer and positive correlation between inner $SO_2$ concentration and outer $SO_2$ concentration in summer and winter in underground shopping center. 4. The mean concentration of $NO_2$ within a underground shopping center was $0.052{\pm}0.038ppm$ in winter and $0.042{\pm}0.016ppm$ in summer. There was a no correlation between inner $SO_2$ concentration and thermal factors in summer and winter and low correlation between inner $SO_2$ concentration and outer $SO_2$ concentration in underground shopping center 5. The mean concentration of TSP within a underground shopping center was $430{\pm}214{\mu}g/m^3$ in winter, $366{\pm}73{\mu}g/m^3$ in summer, and very in excess of the atmospheric environmental quality standards of Korea ($150{\mu}g/m3{\downarrow}$). There was low correlation between inner TSP concentration and temperature in summer and high correlation between inner TSP concentration and outer TSP concentration in underground shopping center.

  • PDF

Estimation of the Formaldehyde Concentration of Subterranean Shopping Centers according to their Spatial Configuration and Renovation (지하도상가의 리모델링 및 공간 특성에 따른 포름알데히드 농도 분석)

  • Sim, Kyung-Sub;Kim, Hyunsoo;Yu, Seulgi;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.25 no.3
    • /
    • pp.182-187
    • /
    • 2014
  • Underground shopping center has become a important commercial facility due to their good accessibility to the public transport. However, underground shopping center has high risk of air contaminants emission like formaldehyde and lowered indoor air quality. In this study, formaldehyde concentration of the underground shopping center was estimated according to the renovation and characteristics of space. It was found that newly renovated underground shopping center has low formaldehyde concentration. In case of closed entrance type, the formaldehyde concentration was 320 % higher than open type. Formaldehyde concentration was varied by product type and especially, high formaldehyde concentration was measured near the stores selling nail polish and cosmetics. It is important to apply appropriate ventilation system according to characteristics of space.

  • PDF

Behavior of Formaldehyde Concentration by Temperature and Humidity of Indoor and Outdoor in Underground Shopping Center and Subway(II) (지하상가 실내외 및 지하철의 온도와 습도에 따른 Formaldehyde 거동(II))

  • 권우택
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.1
    • /
    • pp.67-75
    • /
    • 1994
  • Formaldehyde has been in widespread industrial use since World War II . Numerous sources of formaldehyde are present in the indoor environment. Additionally, the current trend toward tighter, more energy efficient buildings with lower ventilation rates has led to increase concentrations of this and other pollutants generated indoors. In this paper, the field survey was carried out once a month from January to MarctL 1994 to measure indoor and outdoor formaldehyde concentration in several underground locations in Seoul. The results could be summarized as follows : 1. At Yang- jae underground shopping center, the mean formaldehyde concentration was 77.8ppb for indoor and 68.4ppb for outdoor. At Ban- po underground shopping center, it was 175.8ppb for indoor and 127.3ppb for outdoor. At Jam- shil underground shop ping center, it was 135.2ppd for indoor and 34.6ppb for outdoor. Indoor the No.2 sub way line, it was 105.6ppb. The formaldehyde concentration using Berge equation was as follows : At Yang- jae underground shopping center, the mean formaldehyde concentration was 85.99ppb for indoor and 72.75ppb for outdoor At Ban- po underground shopping center, it was 254. 17ppb for indoor and 138.14ppb for outdoor. At Jam- shil underground shopping center, it was 249.13ppb for indoor and 36.87ppb for outdoor. Indoor the No.2 subway line, it was 131.73ppb. 3, The result of correlation analysis indicated that the relationship between temperature and formaldehyde concentration is very high( $\gamma $= 0.831 ∼ 0.974). 4. Also, the relationship between humidity and formaldehyde concentration is variant ($\gamma $ = 0.246 ∼0.999). 5. The mean formaldehyde concentration indoor and outdoor Ban- po underground shop ping center and indoor Jam- shil underground shopping center and indoor the No.2 sub way line exceed the American Society of Heating, Refrigeration, Air- conditioning Engineers( ASHRAE) stflndard of 100ppb(120 $\mu $g/m$^{3}$).

  • PDF

An Experimental Study on the Characteristics of Train-Wind in Underground Shopping Center Connected to Subway Station (지하도 상가와 지하 역사 연계구에서 열차풍 발생 특성에 관한 실험적 연구)

  • Hwang, In-Ju;Lee, Hong-Cheol
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.82-87
    • /
    • 2005
  • The characteristics of train-wind in the underground shopping center(UGSC) connected to subway station is investigated by field measurement for the case of train movement such as arrival and departure, etc. Also air curtain installed at the pass way between underground shopping center and subway station were considered as the parameter in order to analysis the effect on indoor air quality and thermal condition. The measurement data such as velocity, relative humidity, wind-pressure were plotted as quantity variation with time scale. The train-wind affected wind velocity, air pressure and relative humidity at the connecting area of underground shopping center and subway station, and the variation was about 4.5 m/s, 8%, 40 Pa. Also the result showed that the air curtain is not proper to reduce influence of train-wind

  • PDF

An Experimental Study on the Heating Characteristics of HVAC Systems for Shopping Center in Underground Passage (지하도 상가 냉난방.환기 시스템의 난방운전 특성 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju;Kim, Tae-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2989-2994
    • /
    • 2008
  • The shopping center in underground passage for efficient space utilization is increased in urban area. This study describes operation characteristics of HVAC systems with ventilation and individual heating and cooling unit for shopping center in underground passage. In order to compare energy saving, thermal environment and installation space, etc., an integrated simulator with heat production and distribution system was designed and constructed. Energy delivery efficiency is improved over 20%, and energy saving of the hybrid system is calculated as over 30% compared to conventional all air type in the case of heating. And also the results showed that humidity decreased about $5{\sim}6%$, also characteristics of thermal control is improved over 34%.

  • PDF

Indoor and Outdoor Formaldehyde Concentrations in Underground Environments (실내외 포름안데히드 농도에 관한 조사연구)

  • 김윤신;김미경
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.2
    • /
    • pp.1-9
    • /
    • 1989
  • A pilot study was conducted in order to measure indoor and outdoor formaldehyde levels during August 3 - 22, 1988 in several underground spaces in Seoul. Formaldehyde concentrations were monitored during 1 week in selected sampling areas (subway station, underground shopping center, underpass, tunnel, underground parking lot) using passive formaldehyde monitors. In order to investigate a relationship between respiratory prevalence and levels of formaldehyde, each subject was asked to answer respiratory questions. The mean formaldehyde concentrations were 60.1 ppb in subway station, 122.2 ppb in underground shopping stores, 72.1 ppb in underpasses, 39.7 ppb in tunnel, and 75.9 ppb in underground parking lots, respectively. The mean indoor formaldehyde concentrations in underground environments varied from 28.6 ppb to 118.7 ppb. Generally, the mean formaldehyde concentrations in ticketing office in subway stations appeared higher than those level measured in platform. The mean formaldehyde concentrations of underground shopping center in Gangnam Terminal were higher than any other areas and it exceeded 100 ppb of the American Ambient Air Quality Standards of formaldehyde. Prevalence rates of respiratory symptoms of dwellers seemed to be related to higher indoor formaldehyde levels.

  • PDF

Analysis on the Factors Affecting the Satisfaction of Underground Shopping Center -From the cases in Busan Metropolitan Region- (지하도 상가 만족도에 영향을 미치는 요인 분석 -부산시 사례를 중심으로-)

  • Han, Seung-Uk;Jang, Jin-Hyeok;Choi, Yeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.297-307
    • /
    • 2017
  • There are many underground spaces available in an urban environment and they represent an important factor for efficient land use. Especially, underground shopping centers perform both physical and commercial functions at the same time and are frequently used as a means of achieving the revitalization of the city center. However, the underground shopping centers that were developed in the past sometimes led to recession due to their deterioration. This study was carried out for the purpose of proposing alternative methods for the (revitalization) of underground shopping centers. A survey was conducted on seven underground shopping centers in the Busan metropolitan area to understand the factors that determine their user satisfaction and future improvement. The survey data was analyzed using an ordered logit model. As a result of the analysis, service satisfaction, underground environment satisfaction and public facility satisfaction were selected as significant variables. It was concluded that it is necessary to take these factors into consideration, appropriately, when developing a new or renewing an existing underground shopping mall.

A Study on the Activation Strategy of Underground Shopping Malls: Focusing on Public Underground Shopping Malls in Six Major Cities

  • KIM, Gi Pyoung;LEE, Yong Kyu;LEE, Guen Woo;YOU, Chang Kwon
    • The Journal of Industrial Distribution & Business
    • /
    • v.13 no.6
    • /
    • pp.39-49
    • /
    • 2022
  • Purpose: As part of these efforts, in-depth research is needed on efficient and practical utilization of underground spaces and underground shopping malls. In addition, efforts are being made to find effective alternatives to various problems currently occurring in underground shopping malls, but it is not easy. In addition, the development entity and the maintenance entity are different from each other, and the management is not unified, making it difficult to maintain underground shopping malls. From this point of view, it can be said that it is time to actively and specifically discuss ways to revitalize underground shopping malls. Data and methodology: In the domestic distribution environment, traditional markets and shops are stagnating due to rapid changes in consumption patterns, such as the spread of large companies with advanced distribution techniques such as hypermarkets, shopping malls, and SCM, the rapid increase in Internet and home shopping, and the importance of convenience for young consumers. In order to revitalize underground shopping malls, it is necessary to strengthen the organization and self-rescue efforts of merchants' associations, change consciousness through merchant education, change to specialized markets, find nuclear stores and representative restaurants, and support the hardware sector. Results: The connection of underground shopping malls in each region of the country, where commercial districts are separated from each other, will also play an important role in reviving the function of the city in the future. To do this, it is first necessary to connect underground shopping malls that have been cut off. In other words, connection between connectable underground shopping malls should be promoted. Of course, long-term projects should be promoted step by step, and many consultations should be made on how to connect with the ground for each local government. Conclusion: This is because in the future, the underground space cannot just be a walking place, but another space of the Korean Wave where you can experience satisfying the five senses. K-shopping Hallyu content can be created by creating a characteristic story for each underground shopping mall in the city, permanently this story-oriented event, and creating a safe and elegant environment. If there is a story, so-called "Senomi Shopping" will be possible. A new Korean Wave will be created that can satisfy "the fun of writing, the fun of seeing, and the fun of feeling" at the same time.

An Experimental Study on the Operating Characteristics with HVAC Type of Shopping Center in Underground Passage (지하도상가의 HVAC 구성방식에 따른 운전특성 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.76-81
    • /
    • 2007
  • The shopping center in underground passage increased for efficient space utilization in urban area. This study describes operation characteristics of all air type and hybrid type with local ventilation and fan coil unit fixed to ceiling. In order to compare energy saving, thermal environment and installation space, etc., integrated simulator with heat production and indoor distribution system is designed and constructed. Energy saving of the hybrid system is calculated as over 30% compared to conventional all air type. And also the results showed that humidity decreased about 6%, also indoor thermal distribution is improved as temperature variation of around $1^{\circ}C$.

  • PDF