• Title/Summary/Keyword: Underground

Search Result 7,730, Processing Time 0.031 seconds

A Study on the Spatial Planning of Community in Urban Underground Space for Sustainable Urban Regeneration (지속가능한 도시재생을 위한 도심 지하공간의 커뮤니티 공간 계획에 관한 연구)

  • Ha, Mi-Kyoung;Kim, A-Hyun;Lee, Hyo-Chang
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.3
    • /
    • pp.205-216
    • /
    • 2013
  • Korean cities need sustainable urban regeneration based on the effective application of space and resource. Especially a sustainable urban regeneration needs the activation of community in the urban underground space as urban development center. The purpose of this study is to propose elements and factors of spatial planning of community in urban underground space for sustainable urban regeneration and to propose the characteristics of spatial planning of community in urban underground space according to strategies of sustainable urban regeneration. The research methods of this study used to conduct research include precedent study reviews and survey. The conclusions of this study are as following; The application of various factors related to spatial planning aspect of communication, supportive cultural facilities, accessibility and nature is needed for creating a sustainable urban regeneration. Especially, in urban underground space, the application of spatial planning for community activation considered strategies of sustainable urban regeneration should be necessary. And introduction of cultural facilities, multi-dimensional pedestrian network for accessibility and natural elements for activating community in urban underground space are needed for making sustainable urban regeneration.

Heating Effect of Greenhouse Cultivated Mangos by Heat Pump System using Underground Air as Heat Source (지하공기 이용 히트펌프시스템의 망고온실 난방효과)

  • Kang, Younkoo;Kim, Younghwa;Ryou, Youngsun;Kim, Jongkoo;Jang, Jaekyoung;Lee, Hyoungmo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.200.1-200.1
    • /
    • 2011
  • Underground air is a special energy source in Jeju and distributes lava cave, pyroclastic, open joint, and crushing zone. A possible area to utilize underground air is 85% of Jeju except to the nearby area of Sambang Mt. and 25m high coastal area from sea level. In Jeju, underground air is used for heating agricultural facilities such as greenhouse cultivated mangos, Hallbong and mandarin orange, pigsty, mushroom cultivation house, etc. and fertilizing natural $CO_2$ gas by suppling directly into agricultural facilities. But this heating method causes several problem because the underground air has over 90% relative humidity and is inadequate in heating for crops. Mangos are the most widely grown tropical fruit trees and have been cultivated since 1993 in Jeju. In Jeju, the cultivating area is about 20ha and amount of harvest is 275ton/year in 2010. In this study, the heat pump system using underground air as heat source was installed in mangos greenhouse which area is $495m^2$. The capacity of heat pump system and heat storage tank was 10RT, 5ton respectively and heating effect and heating performance of the system were analysed.

  • PDF

Incorporating ground motion effects into Sasaki and Tamura prediction equations of liquefaction-induced uplift of underground structures

  • Chou, Jui-Ching;Lin, Der-Guey
    • Geomechanics and Engineering
    • /
    • v.22 no.1
    • /
    • pp.25-33
    • /
    • 2020
  • In metropolitan areas, the quantity and density of the underground structure increase rapidly in recent years. Even though most damage incidents of the underground structure were minor, there were still few incidents causing a great loss in lives and economy. Therefore, the safety evaluation of the underground structure becomes an important issue in the disaster prevention plan. Liquefaction induced uplift is one important factor damaging the underground structure. In order to perform a preliminary evaluation on the safety of the underground structure, simplified prediction equations were introduced to provide a first order estimation of the liquefaction induced uplift. From previous studies, the input motion is a major factor affecting the magnitude of the uplift. However, effects of the input motion were not studied and included in these equations in an appropriate and rational manner. In this article, a numerical simulation approach (FLAC program with UBCSAND model) is adopted to study effects of the input motion on the uplift. Numerical results show that the uplift and the Arias Intensity (Ia) are closely related. A simple modification procedure to include the input motion effects in the Sasaki and Tamura prediction equation is proposed in this article for engineering practices.

Artifical Groundwater Recharge Using Underground Piping Method

  • Ahn, Sang-Jin;Lee, Jong-Hyong
    • Korean Journal of Hydrosciences
    • /
    • v.3
    • /
    • pp.11-29
    • /
    • 1992
  • Recently, rapid industrialization, urbanization and higher living standards accelerate to increase groundwater consumption resulting in continuously dropping groundwater elevations. To maintain enough groundwater volume without dropping groundwater elevations, the proper groundwater rechatge is necessary. The groundwater rechatge can be classified into two categories which are natural rechatge and artiticial rechatge. Even though the natural rechatge through by dired infiltration from the rainfall is desirable, the artificial groundwater rechatge is necessaty when the increment of groundwater consumption exceeds natural recharge rate. Well method and scattering method are utilized as artificial rechatging method, a severe disadvantage, which is the reduction of the void of soil surface, is indicated in the well method. Recently, the underground piping method, which is a scattering method, is receiving increasing attention as a proper recharging method. The method is indirectly to supply water to the underground using an underground piping system. Therefore, the void of soil surface is not severely reduced and better infiltration rate can be achieved. In this paper, the artificial groundwater rechatge using underground piping method is investigated through experiments and numerical analysis. The influence of the groundwater by underground piping method is evaluated through comparing recharging heights. Good agreements between experiments and numerical analysis are obtained and the artificial groundwater recharge by underground piping method is well tested and verified.

  • PDF

Design of Wireless Underground Sensor System Using Magnetic Field Communication (자기장 통신을 이용한 무선 지중 센서 시스템 설계)

  • Kim, Sun-Hee;Lee, Seungjun;Hwang, Kyu-Sung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.97-102
    • /
    • 2012
  • Recently, a wireless sensor network system has been receiving great attention for management of underground facilities. However, traditional wireless communication systems using microwaves in several hundred MHz ~ several GHz experience significant performance degradation in the non-uniform underground environment. In this research, in order to make a robust communication for the underground facilities, we propose a wireless underground sensor system based on magnetic field communication. In 3 meters underground environment including rocks, soils, water, etc.,, our proposed sensor network system has proved fully functional and met its performance specification.

Development of Standard Guideline for Water-leakage and Maintenance by parts of the Underground Structures in Multi-Family Housing - A Case Analysis of Water Leak Diagnosis - (공동주택 지하구조물의 부위별 표준 누수 진단 유지관리 지침 개발 - 누수 진단 사례 분석 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.142-143
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF

Establishment of Design Standard and Analysis of Insulation Property for Underground Space in Architecture (건축물의 지하공간을 위한 단열재의 특성 분석 및 설계 기준 수립)

  • Hwang, Min-Kyu;Cho, Woo-Jin;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • The purpose of this study is to analyze an insulation property and to establish a design standard for the underground space in architecture. Insulation materials for this study are 12 kinds of Insulation which qualified KS standards(3 classes of EPS type 1, 3 classes of EPS type 2(Neopor), 3 classes of XPS and 3 classes of PU Boards). For insulation materials of underground space, insulating and water tightening property are desired. So conductivity for insulating and water absorption for water tightening are measured in this study. Temperature, insulation is exposed to in the underground space, is different from temperature above the ground. Conductivity is measured in a temperature of $17^{\circ}C$, $20^{\circ}C$, $23^{\circ}C$ and $26^{\circ}C$. In KS standards, water absorption are measure after 24 hours, but insulation is exposed to water for a long time in the underground. So after 110 days, water absorption are measured. As time goes by, increasing of water absorption means decreasing of water tightening and insulating. So after water absorption had measured for 110 days, conductivity has measured again. As a result, XPS is selected as optimized insulation for underground. And Conductivity of XPS insulation with water should be added by 20%.

Developed Location Based Service System for Management of Underground Facilities' DB (지하시설물 DB의 유지관리를 위한 LBS 시스템 개발)

  • 이현직;황창섭;박기석;유지호
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.11a
    • /
    • pp.325-333
    • /
    • 2004
  • Since 1995, One of the NGIS(National Geographic Information System) projects, the underground utilities project has been finished in 2003. The 19 cities in korea for this project will use underground utilities management system using underground utilities database focusing on water and sewage system. However, special expert, technical and experience problem in computer environment has not been had in working department for water and sewage management and maintenance for each local government. The management and maintenance of underground utilities database by manual method is getting lowered a data quality of underground utilities database because of the data omitting, error in writing and securing of the lasted database. Therefore, in this study, Application test for field workers using a mobile tool and environment analysis of wireless communication in Korea and application test of GPS receiver for mobile tools had been processed and made a mobile working environment. The efficient management and maintenance method for underground utilities database has been developed an off- line method for modification and update of database about general work which has a high working frequency because of the limitation of wireless communication environment Also, the emergency working has been applied for on-line method.

  • PDF

The Possibility on Utilization of Underground Pit for Reduction of Cooling and Heating Load (냉방과 난방 부하 감소를 위한 지하피트의 이용 가능성)

  • Cho Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.144-150
    • /
    • 2006
  • The purpose of this study is to predict outlet temperature and humidity through underground pit for the reduction of cooling load and heating load. Commonly, the underground temperature is lower than outdoor in summer but the reverse happens in winter. When the outdoor average air temperature is $25.7^{\circ}C$ during cooling periods, the average outlet air temperature through underground pit is $23.6^{\circ}C$ with 3 m-depth and 60m-length and is $22.2^{\circ}C$ with 3 m-depth and 150 m-length. When the outdoor average air temperature is $4.9^{\circ}C$ during heating periods, the average outlet air temperature through underground pit is $7.7^{\circ}C$ with 3m-depth and 60 m-length and is $10.8^{\circ}C$ with 3 m-depth and 150 m-length. The outlet air temperature is affected by more length than depth of underground pit. The diffusion ratio of outdoor humidity is $-7.7\times10^{-8}kg/s$ in cooling periods and $9.29\times10^{-7}kg/s$ in heating periods.

Proposal on the Standard Water Leakage Diagnosis Manual of Leakage Type in Underground Structures Housing -Focused on Maintenance Plan - (공동주택 지하구조물 표준 누수 진단 매뉴얼 제안 - 유지관리 계획을 중심으로 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.221-222
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF