• Title/Summary/Keyword: Under-Water Treatment

Search Result 1,627, Processing Time 0.033 seconds

Saturation curves for chemical coagulation of wastewater treatment (화학 응집제 투입에 따른 수질항목별 하수처리 반응곡선)

  • Ryu, Jae-Na;Oh, Je-Ill;Lee, Kyeoung-Jong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.537-548
    • /
    • 2010
  • Recently the Government has announced updated water quality standards for wastewater treatment effluent (become effective in 2012). That includes highly enforced regulations for T-P, BOD and COD, and a large budget, in particular for phosphorus removal, was set by the Ministry of environment. Chemical coagulation destabilizes colloidal particles so that particles grow to larger flocs, and solid particles are removed by solid-liquid separation. The efficiency of chemical coagulation depends on a various factors, including coagulant types and costs, construction and operation costs for the treatment facilities and so on. The proper selection should be based on the treatment efficiency of coagulants and underlying costs. The current research was to evaluate the treatment efficiencies of coagulants on a variety of wastewater influents and to develop saturation curves for several water quality parameters. Typical $Al_2(SO_4)_3$ and $FeCl_3$ were tested under a range of coagulant concentrations. The pollutant removal efficiencies of chemical treatment both for the $Al_2(SO_4)_3$ and $FeCl_3$ were especially high for T-P, followed by SS, BOD and COD. Correlation test also proved the highest relationship between SS and T-P.

A Study on the Application of Micro Hydro Power Generator at the Water Treatment Plant (정수장 마이크로 소수력 발전기 적용에 대한 연구)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Kim, Il-Jung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.67-72
    • /
    • 2014
  • Inflow or outflow from the water treatment plant and the sewage water has potential energy. If this potential energy can be converted into electrical energy by water turbine generator, it can help to save energy because of the high capacity utilization. So recently, micro hydro power plant is reviewed in the water treatment facility. If generation capacity is low, induction generator is primarily used. If output capacity is low, generated power is supplied to the inside load. Induction generator can cause voltage drop by the inrush current at a start-up and requires reactive power for magnetization. In this study, we analyzed the flow of power and voltage variation against inrush current that occurs when the induction generator starts under the terms that loads of linear and non-linear of the water purification plant are used. Analysis results are that the voltage drop is within an allowable range and the power factor is slightly reduced by the need of reactive power.

Plasma-Surface-Treatment of Nylon 6 Fiber for the Improvement of Water-Repellency by Low Pressure RF Plasma Discharge Processing (나일론 6 섬유의 발수성 향상을 위한 RF 플라스마 표면처리)

  • Ji, Young-Yeon;Jeong, Tak;Kim, Sang-Sik
    • Polymer(Korea)
    • /
    • v.31 no.1
    • /
    • pp.31-36
    • /
    • 2007
  • It has been reported that the surface properties of the plasma treated material were changed while maintaining its bulk properties. In this study, surface modification of nylon fiber by plasma treatment was tried to attain high water-repellency Nylon fiber was treated with RF plasma under a vacuum system using various parameters such as gas specious, processing time and processing power. Morphological changes by low pressure plasma treatment were observed using scanning electron microscopy (SEM) and atomic force microscopy (AFM). Moreover, the mechanical and inherent properties were analyzed by tensile strength, differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). The high water-repellency property of nylon fiber was evaluated by a water-drop standard test under various conditions in terms of aging effect. The results showed that the water-repellency of plasma-surface-treated nylon fiber was greatly improved compared to untreated nylon fiber.

The Effect of Functional Water on the compressive strength of Mortar (기능수가 모르타르의 압축강도에 미치는 영향)

  • Han, Jeong-Seb
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.79-82
    • /
    • 2002
  • To study the effect of functional water on the compressive strength of mortar, city water was changed to functional water through ceramics treatment. The change of characteristics of water was measured with $O^{17}$ NMR and Killian Camera. The compressive strength of mortar was measured with various curing conditions. The test results show that by the ceramics treatment the characteristics of city water was changed. At 28 days under curing condition, the compressive strength of mortar which was mix-proportioned with treated water was increased about 22 % than that of mortar which was mix-proportioned with untreated city water.

  • PDF

Lignification in Relation to the Influence of Water-deficit Stress in Brassica napus

  • Lee, Bok-Rye;Zhang, Qian;Kim, Tae-Hwan
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.34 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • To investigate lignification process and its physiological significance under water-deficit condition, the responses of peroxidases, polyphenol oxidase (PPO) and phenylalanine ammonia-lyase (PAL) in relation to leaf water status to the short term of water deficit treatment in the leaves with different maturities in forage rape were measured. The significant decrease in relative water content (RWC) and leaf osmotic potential (${\Psi}{\pi}$) were apparent after 5 d of water-deficit treatment. The activity of guaiacol peroxidase (GPOD), ascorbate peroxidase (APOD), coniferyl alcohol peroxidase (CPOD), and syringaldazine peroxidase (SPOD) was depressed especially in middle and old leaves when compared with that of control leaves. On the other hand, in young leaves, a significant increase in CPOD (+34%) and SPOD (+24%) activity as affected by water-deficit treatment was apparent. The activation of PAL and PPO was observed in middle and old leaves for PAL and in young and middle leaves for PPO. These results suggest that peroxidases in middle and old leaves did not involve in lignification under mild water-deficit stress, whereas CPOD and SPOD in young leaves participate in lignification by a coordination with PAL and PPO to incorporate phenol and lignin into the cell walls.

Preliminary Studies for Efficient Treatment of Wastewater Milking Parlor in Livestock Farm (젖소 착유세정폐수의 효율적인 정화처리를 위한 기초연구)

  • Jang, Young Ho;Lee, Soo Moon;Kim, Woong Su;Kang, Jin Young
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.500-507
    • /
    • 2020
  • This study examined the wastewater at a livestock farm, and found that the dairy wastewater from the milking parlor had a lower concentration than the piggery wastewater, and that it was produced at a rate under 1.3 ㎥/day in a single farmhouse. The amount of dairy wastewater was determined based on the performance of the milking machine, the maintenance method of the milking parlor, and the amount of milk production allocated for each farmhouse, not by the area. The results confirmed that both dairy wastewater treatment processes, specifically those using Hanged Bio-Compactor (HBC) and Sequencing Batch Reactor (SBR), can fully satisfy the water quality standards of discharge. The dairy wastewater has a lower amount and concentration than piggery wastewater, meaning it is less valuable as liquid fertilizer, but it can be easily degraded using the conventional activated sludge process in a public sewage treatment plant. Therefore, discharging the dairy wastewater after individual treatment was expected to be a more reasonable method than consigning it to the centralized wastewater treatment plant. The effluent after the SBR process showed a lower degree of color than the HBC effluent, which was attributed to biological adsorption. In the case of the milking parlor in the livestock farm, the concentrations of the effluents obtained after HBC and SBR treatments both satisfied water quality standards for the discharge of public livestock wastewater treatment plants at 99% confidence intervals, and the concentrations of total nitrogen and phosphorous in untreated wastewater were even lower than the water quality standards of discharge. Therefore, we need to discuss strengthening the water quality standards to reduce environmental pollution.

Application of peak load for industrial water treatment plant design (공업용수 정수장 설계시 첨두부하 적용방안)

  • Kim, Jinkeun;Lee, Heenam;Kim, Dooil;Koo, Jayong;Hyun, Inhwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.225-231
    • /
    • 2016
  • Peak load rate(i.e., maximum daily flow/average daily flow) has not been considered for industrial water demand planning in Korea to date, while area unit method based on average daily flow has been applied to decide capacity of industrial water treatment plants(WTPs). Designers of industrial WTPs has assumed that peak load would not exist if operation rate of factories in industrial sites were close to 100%. However, peak load rates were calculated as 1.10~2.53 based on daily water flow from 2009 to 2014 for 9 industrial WTPs which have been operated more than 9 years(9-38 years). Furthermore, average operation rates of 9 industrial WTPs was less than 70% which means current area unit method has tendency to overestimate water demand. Therefore, it is not reasonable to consider peak load for the calculation of water demand under current area unit method application to prevent overestimation. However, for the precise future industrial water demand calculation more precise data gathering for average daily flow and consideration of peak load rate are recommended.

Effect of Hot Water and Heat Treatment on the Apatite-forming Ability of Titania Films Formed on Titanium Metal via Anodic Oxidation in Acetic Acid Solutions

  • Cui, Xinyu;Cui, Xinyu
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.36.2-36.2
    • /
    • 2011
  • Titanium and its alloys have been widely used for orthopedic implants because of their good biocompatibility. We have previously shown that the crystalline titania layers formed on the surface of titanium metal via anodic oxidation can induce apatite formation in simulated body fluid, whereas amorphous titania layers do not possess apatite-forming ability. In this study, hot water and heat treatments were applied to transform the titania layers from an amorphous structure into a crystalline structure after titanium metal had been anodized in acetic acid solution. The apatite-forming ability of titania layers subjected to the above treatments in simulated body fluid was investigated. The XRD and SEM results indicated hot water and/or heat treatment could greatly transform the crystal structure of titania layers from an amorphous structure into anatase, or a mixture of anatase and rutile.The abundance of Ti-OH groups formed by hot water treatment could contribute to apatite formation on the surface of titanium metals, and subsequent heat treatment would enhance the bond strength between the apatite layers and the titanium substrates. Thus, bioactive titanium metals could be prepared via anodic oxidation and subsequent hot water and heat treatment that would be suitable for applications under load-bearing conditions.

  • PDF

Overcapacity of Water Treatment Plants in Korea (국내 정수장 과다시설용량 실태 분석)

  • Lee, Sangeun;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.57-67
    • /
    • 2009
  • Under the supply-oriented policy, efficiency and rationale have not been fully considered in planning of water supply facilities in Korea. As a case, this study shows that large-size systems are suffering from overcapacity problem of water treatment plants, and thus discusses what options should be applied to deal with inefficiency. Water demand of large-size systems has suddenly decreased for the last 10 years while water demand has been often assumed to increase at a regular rate in planning of plants according to excess capacity hypothesis. This inconsistency led to a serious overcapacity. In 2006, total excess capacity of nine large-size systems was more than 1.2 times as large as maximum daily demand of total customers in Seoul. However, their options are expected to stay ex post facto. To prepare the risk of overcapacity, and draw large benefits out of the plants, the authors and other professionals in Korea should further discuss the more adaptive method for prediction of water demand, and systems integration between a large-size system and adjoining systems.

Effects of Water Deficit on Biomass Accumulation and Water Use Efficiency in Soybean during Vegetative Growth Period

  • Kim, Wook-Han;Hong, Byung-Hee;Larry C. Purcell
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.45 no.1
    • /
    • pp.6-13
    • /
    • 2000
  • Water deficit is the primary constraint of soybean [Glycine max (L.) Merr.] yield, and a physiological understanding of processes affected by water deficit is a key step in identifying and improving drought tolerance in soybean. The objectives of this research were to evaluate biomass and nitrogen accumulation patterns and water use efficiency (WUE) as possible mechanisms associated with the drought tolerance of Jackson. Biomass accumulation of Jackson was contrasted with the PI416937, which also has demonstrated tolerance to drought. For water-deficit treatment, total biomass accumulation was negligible for PI416937, but biomass accumulation continued at approximately 64 % of the well-watered treatment of Jackson. Transpirational losses for Jackson and PI416937 were approximately the same for the water-deficit treatment, indicating that Jackson had superior WUE. Isotopic discrimination of $^{13}$ C relative to $^{12}$ C also indicated that Jackson had higher WUE. Results indicated that increased WUE for Jackson under water deficit showed it was tolerant to drought rather than had an avoidance mechanism.

  • PDF