• 제목/요약/키워드: Under frame

검색결과 1,698건 처리시간 0.032초

고속전철용 대차프레임의 다축피로해석에 관한 연구 (A Study on the Multiaxial Fatigue Analysis of Bogie Frame for High Speed Train)

  • 이상록;이학주;한승우;강재윤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 춘계학술대회 논문집
    • /
    • pp.344-351
    • /
    • 1999
  • Stress analysis of bogie frame by using the finite element method has been performed for the various loading conditions according to the UIC (International Union of Railways) Code 615-4. Multiaxial fatigue damage models such as signed von Mises method and typical critical plane theories were reviewed, and multiaxial fatigue analysis program (MUFAP) has been developed. Fatigue analysis of bogie frame under multiaxial loading was performed by using MUFAP and finite element analysis results. The procedure developed in this study is considered to be useful for the life prediction in preliminary design stage of railway components under multiaxial loading conditions. 3-dimensional surface modeling, mesh generation and finite element analysis were performed by Pro-Engineer, MSC/PATRAN and MSC/NASTRAN, respectively, which were installed in engineering workstation.

  • PDF

Redundancy of Dual and Steel Moment Frame Systems under Earthquakes

  • Song, S.H.;Wen, Y.K.
    • Computational Structural Engineering : An International Journal
    • /
    • 제1권2호
    • /
    • pp.137-137
    • /
    • 2001
  • The reliability/redundancy of structural system has become a serious concern among engineers and researchers after structural failures in Northridge and Kobe earthquakes. The reliability/redundancy factor, ρ, in current codes considers only member force and floor area and has received much criticism from dissatisfied engineers. Within a reliability framework. the redundancy is investigated for dual systems of primary shear walls and secondary moment frames and steel moment frame systems. Probabilistic performance analyses are carried out baled on nonlinear responses under SAC ground motion. The effects of structural configuration, ductilily capacity, 3-D motion, and uncertainty of demand verses capacity are investigated. Important redundancy-contributing factors are identified and a uniform-risk redundancy factor is developed for design. The result are compared with the p factor and its inconsistency is pointed out.

  • PDF

계통 연계형 단상 인버터의 단독 운전 모드를 위한 정지좌표계 전압 제어기 (Stationary Reference Frame Voltage Controller for Single Phase Grid Connected Inverter for Stand Alone Mode)

  • 홍창표;김학원;조관열;임병국
    • 전력전자학회논문지
    • /
    • 제20권6호
    • /
    • pp.517-525
    • /
    • 2015
  • A grid connected inverter must be operated as the main electricity source under an isolated condition caused by the grid problem. Conventionally, the dual loop controller is used for the grid inverter, and the controller is used for control under the stand-alone mode. Generally, the PI(Proportional - Integral) controller is highly efficient under a synchronous reference frame, and stable control can be available. However, in this synchronous frame-based control, high-quality DSP is required because many sinusoidal calculations are necessary. When the PI control is conducted under a stationary frame, the controller constructions are made simple so that they work even with a low-price micro controller. However, given the characteristics of the PI controller, it should be designed with the phase of reference voltage considered. Otherwise, the phase delay of the output voltage can occur. Although the current controller also has a higher bandwidth than the voltage controller, distortion of the voltage is difficult to avoid only by the rapid response of the PI controller, as a sudden load change can occur in the nonlinear load. In this study, a new control method that solves the voltage controller bandwidth problem and rapidly copes with it even in the nonlinear load situation is proposed. The validity of the proposed method is proved by simulation and experimental results.

An Improved Stationary Frame-based Digital Current Control Scheme for a PM Synchronous Motor

  • Kim Kyeong-Hwa;Youn Myung-Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.174-178
    • /
    • 2001
  • An improved stationary frame-based digital current control technique for a permanent magnet (PM) synchronous motor is presented. Generally, the stationary frame current controller is known to provide the advantage of a simple implementation. However, there are some unavoidable limitations such as a steady-state error and a phase delay in the steady-state. On the other hand, in the synchronous frame current regulator, the regulated currents are dc quantities and a zero steady-state error can be obtained through the integral control. However, the need to transform the signals between the stationary and synchronous frames makes the implementation of a synchronous frame regulator complex. Although the PI controller in the stationary frame gives a steady-state error and a phase delay, the control performance can be greatly improved by employing the exact decoupling control inputs for the back EMF, resulting in an ideal steady-state control characteristics irrespective of an operating condition as in the synchronous PI decoupling controller. However, its steady-state response may be degraded due to the inexact cancellation inputs under the parameter variations. To improve the control performance in the stationary frame, the disturbance is estimated using the time delay control. The proposed scheme is implemented on a PM synchronous motor using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF

Experimental studies on steel frame structures of traditional-style buildings

  • Xue, Jianyang;Qi, Liangjie
    • Steel and Composite Structures
    • /
    • 제22권2호
    • /
    • pp.235-255
    • /
    • 2016
  • This paper experimentally investigated the behavior of steel frame structures of traditional-style buildings subjected to combined constant axial load and reversed lateral cyclic loading conditions. The low cyclic reversed loading test was carried out on a 1/2 model of a traditional-style steel frame. The failure process and failure mode of the structure were observed. The mechanical behaviors of the steel frame, including hysteretic behaviors, order of plastic hinges, load-displacement curve, characteristic loads and corresponding displacements, ductility, energy dissipation capacity, and stiffness degradation were analyzed. Test results showed that the Dou-Gong component (a special construct in traditional-style buildings) in steel frame structures acted as the first seismic line under the action of horizontal loads, the plastic hinges at the beam end developed sufficiently and satisfied the Chinese Seismic Design Principle of "strong columns-weak beams, strong joints-weak members". The pinching phenomenon of hysteretic loops occurred and it changed into Z-shape, indicating shear-slip property. The stiffness degradation of the structure was significant at the early stage of the loading. When failure, the ultimate elastic-plastic interlayer displacement angle was 1/20, which indicated high collapse resistance capacity of the steel frame. Furthermore, the finite element analysis was conducted to simulate the behavior of traditional-style frame structure. Test results agreed well with the results of the finite element analysis.

Micro-concrete composites for strengthening of RC frame made of recycled aggregate concrete

  • Marthong, Comingstarful;Pyrbot, Risukka N.;Tron, Stevenly L.;Mawroh, Lam-I D.;Choudhury, Md. Sakil A.;Bharti, Ganesh S.
    • Computers and Concrete
    • /
    • 제22권5호
    • /
    • pp.461-468
    • /
    • 2018
  • In this paper, to access the suitability of recycled aggregate for structural applications, concrete strength i.e., compressive, tensile and flexural strength were evaluated and compared with those specimens made of natural aggregates. Test results indicated that 30 to 42% of the mentioned strength decreases. To study the performance of frame structures made of recycled aggregate concrete (RAC) two reinforced RAC frames were prepared and tested under monotonic loading. The joint regions of one of the RAC frame were casted with micro-concrete. A reference specimen was also prepared using natural aggregate concrete (NAC) and subjected to a similar loading condition. The RAC frame resulted in a brittle mode of failure as compared to NAC frame. However, the presence of a micro-concrete at the joint region of an RAC frame improved the damage tolerance and load resisting capacity. Seismic parameter such as energy dissipation, ductility and stiffness also improves. Conclusively, strengthening of joint region using micro-concrete is found to have a significant contribution in improving the seismic performance of an RAC frame.

An Improved Stationary Frame-based Digital Current Control Scheme for a PM Synchronous Motor

  • Kim, Kyeong-Hwa;Young, Myung-Joong
    • Journal of Power Electronics
    • /
    • 제1권2호
    • /
    • pp.88-98
    • /
    • 2001
  • An improved stationary frame-based digital current control technique for a permanent magnet(PM) synchronous motor is presented. Generally, the stationary frame current controller is known to provide the advantage of a simple implementation. However, there are some unavoidable limitations such as a steady-state error and a phase delay in the steady-state. On the other hand, in the synchronous frame current regulator the regulated currents are dc quantities and a zero steady-state error can be obtained through the integral control. However, the need to transform the signals between the stationary and synchronous frames makes the implementation of a synchronous frame regulator complex. Although the PI controller in the stationary frame gives a steady-state error and a phase delay, the control performance can be greatly improved by employing the exact decoupling control inputs for the back EMF., resulting in an ideal steady-state control characteristics irrespective of an operating condition as in the synchronous PI decoupling controller. However, its steady-state response may be degraded due to the inexact cancellation inputs under the parameter variations. To improve the control performance in the stationary frame, the disturbance is estimated using the time delay control. The proposed scheme is implemented on a PM synchronous motor using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF

Effect of staircase on seismic performance of RC frame building

  • Kumbhar, Onkar G.;Kumar, Ratnesh;Adhikary, Shrabony
    • Earthquakes and Structures
    • /
    • 제9권2호
    • /
    • pp.375-390
    • /
    • 2015
  • Staircase is a vertical transportation element commonly used in every multistoried structure. Inclined flights of staircase are usually casted monolithically with RC frame. The structural configuration of stairs generally introduces discontinuities into the typical regular reinforced concrete frame composed of beams and columns. Inclined position of flight transfers both vertical as well as horizontal forces in the frame. Under lateral loading, staircase in a multistory RC frame building develops truss action creating a local stiffening effect. In case of seismic event the stiff area around staircase attracts larger force. Therefore, special attention is required while modeling and analyzing the building with staircase. However, in general design practice, designers usually ignore the staircase while modeling either due to ignorance or to avoid complexity. A numerical study has been conducted to examine the effect of ignoring staircase in modeling and design of RC frame buildings while they are really present in structure, may be at different locations. Linear dynamic analysis is performed on nine separate building models to evaluate influence of staircase on dynamic characteristics of building, followed by nonlinear static analysis on the same models to access their seismic performance. It is observed that effect of ignoring staircase in modeling is severe and leads to unsafe structure. Effect of location and orientation of staircase is also important in determining seismic performance of RC frame buildings.

Hysteretic performance of a novel composite wall panel consisted of a light-steel frame and aerated concrete blocks

  • Wang, Xiaoping;Li, Fan;Wan, Liangdong;Li, Tao
    • Steel and Composite Structures
    • /
    • 제41권6호
    • /
    • pp.861-871
    • /
    • 2021
  • This study aims at investigating the hysteretic performance of a novel composite wall panel fabricated by infilling aerated concrete blocks into a novel light-steel frame used for low-rise residential buildings. The novel light-steel frame is consisted of two thin-wall rectangular hollow section columns and a truss-beam assembled using patented U-shape connectors. Two bare light-steel frames and two composite wall panels have been tested to failure under horizontal cyclic loading. Hysteretic curves, lateral resistance and stiffness of four specimens have been investigated and analyzed. Based on the testing results, it is found that the masonry infill can significantly increase the lateral resistance and stiffness of the novel light-steel frame, about 2.3~3 and 21.2~31.5 times, respectively. Failure mode of the light-steel frame is local yielding of the column. For the composite wall panel, firstly, masonry infill is crushed, subsequently, local yielding may occur at the column if loading continues. Hysteretic curve of the composite wall panel obtained is not plump, implying a poor energy dissipation capacity. However, the light-steel frame of the composite wall panel can dissipate more energy after the masonry infill is crushed. Therefore, the composite wall panel has a much higher energy dissipation capacity compared to the bare light-steel frame.

실동응력 측정을 통한 전동차 대차프레임의 내구수명 평가 (Evaluation of Total Serviceable Life of Bogie Frame of Electric Multiple Unit by Dynamic Strain Measurement)

  • 김승섭;한성욱;박근수;우관제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.277-282
    • /
    • 2011
  • Bogie frame is typical safety part of railway vehicle. Total serviceable life of bogie frame will be evaluated by Cumulative Damage Approach Method that is defined by dynamic strain measurement during revenue service under the actual track conditions. As a result of the standardization process developed in British Standard Institution, BS 7608 defines for fatigue design and test method of steel structure by fatigue test results over the long period. This paper evaluates the total serviceable life applying BS 7608 for the bogie frame of Electric Multiple Unit to verify structural safety of the bogie frame.

  • PDF