• Title/Summary/Keyword: Under Cover

Search Result 856, Processing Time 0.026 seconds

A Study on the Scope of Application of Preliminary Draft Convention on International Contract Concluded or Evidenced by Data Message (국제전자계약준비초안(國際電子契約準備草案)의 적용범위에 관한 비교 연구)

  • Oh, Won-Suk
    • International Commerce and Information Review
    • /
    • v.4 no.2
    • /
    • pp.1-12
    • /
    • 2002
  • The purpose of this paper is to examine the scope of the application of Preliminary Draft Convention, which will be fixed as international uniform rules soon, in relation to the CISG. First, this Draft Convention will cover service contracts as well as sales contract of goods, but the license agreement will be excepted because it does not transfer the complete property. Second, this will cover the commercial contracts(sales or services) concluded by data message fully or partially. Third, this will be applied in international contract regardless of contracting states or non-contracting states. As it is very difficult to confirm the places of business of contracting parties in on-line contracts, the first criterion to confirm them is the indication by the party in each contract. This presumption may be supplemented, if they are not indicated in the contract, by the location of the equipment and technology supporting an information system used by a legal entity for the conclusion of a contract. It is essential to establish an international uniform rules as soon as possible in order to activate the international businesses with on-line basis. Thus this author hopes that this paper will contribute to the clear understanding to the scope of application of Preliminary Draft Convention for which the UNCITRAL is under working.

  • PDF

Temperature Analysis for Optimizing the Configuration of the Linear Cell

  • Choi Jong-Wook;Kim Sung-Cho;Kim Jeong-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.7
    • /
    • pp.1089-1097
    • /
    • 2006
  • The market demand of display devices is drastically increasing in the information technology age. The research on OLED (Organic Light Emitting Diodes) display with the luminescence in itself is being more paid attention than LCD (Liquid Crystal display) with the light source from the back. The vapor deposition process is most essential in manufacturing OLED display. The temperature distribution of the linear cell in this process is closely related to securing the uniformity of organic materials on the substrate. This work analyzed the temperature distribution depending on the intervals between the crucible and the heating band as well as on the amount of the heat flux from the heating band. Moreover, the roles of the water jacket and the configuration of the cover within the linear cell were examined through the temperature analysis for six configurations of the linear cell. Under the above temperature analysis, the variations in the intervals and the amount of the heat flux were considered to have an effect on building the uniform temperature distribution within the crucible. It is predicted that the water jacket and the adequate configuration of the cover will prevent the blowout and clogging phenomena, respectively. The results can be used as the fundamental data for designing the optimal linear cell.

changers of Mechanical Properties of Wool Woresed fabrics with fusible Interlingings(Part II) (모직물의 접착심 접착에 의한 물성의 변화 (제2보))

  • 지주원;유효선;이대훈
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.1
    • /
    • pp.22-29
    • /
    • 1999
  • This paper descrived the changes of peel strength wrinkle recovery and dimensional stability after fusing 4 different wool face fabrics with 3 different fusible interlinings. The fusing condition was conducted by fusing press machine under 4kg.f/cm2 at 15$0^{\circ}C$. To determine the effect of the varous physical properties of the fused fabrics face fabrics and interlinings on the peel strength wrinkle recovery and dimensional stability(hygral expansion and relaxation shrinkage) of fused fabrics correlation among the KES values of fused fabrics face fabrics and interlinings to the peel strength rinkle recovery and dimensional stability of fused fabrics were expeerimentally analyzed,. As the results the peel strength was mainly influenced by the cover factor of face fabric and interlinings. After fusing wrinkle recovery and hygral expansion were decreased. The cover factor wrinkle recovery weight thickness shear rigidity and frictional properties of face fabric and the thickness of fused fabrics were not influence to the wrinkle recovery of fused fabrics. In addition the dimensional stabilities of fused fabrics were mainly influenced by the tensile and frictional properties of the wrinkle recovery of fused fabrics. In addition the dimensional stabilities of fused fabrics were mainly influenced by the tensile and frictional properties of the face fabrics.

  • PDF

Analysis of Timed Automata Model-based Testing Approaches and Case Study (타임드 오토마타 모델 기반 테스팅 기법 분석 및 사례 연구)

  • Kim, Hanseok;Jee, Eunkyoung;Bae, Doo-Hwan
    • KIISE Transactions on Computing Practices
    • /
    • v.21 no.2
    • /
    • pp.132-137
    • /
    • 2015
  • A real-time system is a system wherein the behavior of the system depends not only on the input but also on the timing of the input. Timed automata is a widely used model for real-time system modeling and analysis. Model-based testing is employed to check whether the system under test (SUT) works according to the model specifications by using test cases generated from models that represent software requirements. In this paper, a case study was performed applying the timed automata based testing tools, UPPAAL-TRON, UPPAAL-COVER and SYMBOLRT, to the same system. Comparison of the testing approaches and tools is then made based on the results of the case study.

Corrosion effects on tension stiffening behavior of reinforced concrete

  • Shayanfar, M.A.;Ghalehnovi, M.;Safiey, A.
    • Computers and Concrete
    • /
    • v.4 no.5
    • /
    • pp.403-424
    • /
    • 2007
  • The investigation of corrosion effects on the tensile behavior of reinforced concrete (RC) members is very important in region prone to high corrosion conditions. In this article, an experimental study concerning corrosion effects on tensile behavior of RC members is presented. For this purpose, a comprehensive experimental program including 58 cylindrical reinforced concrete specimens under various levels of corrosion is conducted. Some of the specimens (44) are located in large tub containing water and salt (5% salt solution); an electrical supplier has been utilized for the accelerated corrosion program. Afterwards, the tensile behavior of the specimens was studied by means of the direct tension tests. For each specimen, the tension stiffening curve is plotted, and their behavior at various load levels is investigated. Average crack spacing, loss of cross-section area due to corrosion, the concrete contribution to the tensile response for different strain levels, and maximum bond stress developed at each corrosion level are studied, and their appropriate relationships are proposed. The main parameters considered in this investigation are: degree of corrosion ($C_w$), reinforcement diameter (d), reinforcement ratio (${\rho}$), clear concrete cover (c), ratio of clear concrete cover to rebar diameter (c/d), and ratio of rebar diameter to reinforcement percentage ($d/{\rho}$).

Growth Reaction of Some Ground Cover Plant in Korean Native Greening according to Shading Levels (몇 가지 자생 지피식물의 차광에 따른 생장반응)

  • Kim, Gui Soon;Lee, Jeong Sik
    • FLOWER RESEARCH JOURNAL
    • /
    • v.17 no.2
    • /
    • pp.75-80
    • /
    • 2009
  • The objective of this research was to select the native shade tolerance plant which grows well from landscape objective of the urban. Seven species native ground cover plants were evaluated on the growth and chloropyll under 0, 40, 60, 90% shading treatments. Hosta longipes was showed the quite good growth from 60% level of natural light. The plant growth of Liriope platyphylla was good within $144.2{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ intensity which is 90% shade level of natural light. But, Dryiopteris crassirhizoma was judged with shade tolerance plant which grow quite well from shading condition level of 60% degree. Carex siderosticea was showed the highest plant length and plant width in 40% shading of natural light more than at conditon too much shading. Hosta longipes, Liriope platyphylla, Dryiopteris crassirhizoma, and Carex siderosticea were as shade tolerance plant with increases chlorophyll content well to overcome a light restrictive condition and is adapted to seem with the result.

Service life prediction of a reinforced concrete bridge exposed to chloride induced deterioration

  • Papadakis, Vagelis G.
    • Advances in concrete construction
    • /
    • v.1 no.3
    • /
    • pp.201-213
    • /
    • 2013
  • While recognizing the problem of reinforcement corrosion and premature structural deterioration of reinforced concrete (RC) structures as a combined effect of mechanical and environmental actions (carbonation, ingress of chlorides), emphasis is given on the effect of the latter, as most severe and unpredictable action. In this study, a simulation tool, based on proven predictive models utilizing principles of chemical and material engineering, for the estimation of concrete service life is applied on an existing reinforced concrete bridge (${\O}$resund Link) located in a chloride environment. After a brief introduction to the structure of the models used, emphasis is given on the physicochemical processes in concrete leading to chloride induced corrosion of the embedded reinforcement. By taking under consideration the concrete, structural and environmental properties of the bridge investigated, an accurate prediction of its service life is taking place. It was observed that the proposed, and already used, relationship of service lifetime- cover is almost identical with a mean line between the lines derived from the minimum and maximum critical values considered for corrosion initiation. Thus, an excellent agreement with the project specifications is observed despite the different ways used to approach the problem. Furthermore, different scenarios of concrete cover failure, in the case when a coating is utilized, and extreme deicing salts attack are also investigated.

A Systems Engineering Approach to Multi-Physics Load Follow Simulation of the Korean APR1400 Nuclear Power Plant

  • Mahmoud, Abd El Rahman;Diab, Aya
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.16 no.2
    • /
    • pp.1-15
    • /
    • 2020
  • Nuclear power plants in South Korea are operated to cover the baseload demand. Hence they are operated at 100% rated power and do not deploy power tracking control except for startup, shutdown, or during transients. However, as the contribution of renewable energy in the energy mix increases, load follow operation may be needed to cover the imbalance between consumption and production due to the intermittent nature of electricity produced from the conversion of wind or solar energy. Load follow operation may be quite challenging since the operators need to control the axial power distribution and core reactivity while simultaneously conducting the power maneuvering. In this paper, a systems engineering approach for multi-physics load follow simulation of APR1400 is performed. RELAP5/SCDAPSIM/MOD3.4/3DKIN multi-physics package is selected to simulate the Korean Advanced Power Reactor, APR1400, under load follow operation to reflect the impact of feedback signals on the system safety parameters. Furthermore, the systems engineering approach is adopted to identify the requirements, functions, and physical architecture to provide a set of verification and validation activities that guide this project development by linking each requirement to a validation or verification test with predefined success criteria.

Spalling Analysis of High-Strength Reinforced Concrete Columns under High Temperature (고온에 노출된 고강도 콘크리트 기둥의 폭렬해석)

  • Shin, Sung-Woo;Yoo, Suk-Hyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.6
    • /
    • pp.193-200
    • /
    • 2007
  • The spalling analysis of high strength concrete columns needs a very complex and difficult process accounting for peeling of cover concrete as well as thermal, thermo-stress and hygro-transfer phenomena. However, the study on the spalling analysis method is insufficient. The practical spalling analysis algorithm is developed in this study, which formulates a vapor pressure equation as the parameter of temperature and cover depth and uses the compatibility condition In results of the spalling analysis, as the concrete strength increases and the content of PP fiber decreases the degree of spalling increases. This shows a similar result as the previous experimental study. Therefore the developed algorithm suggested in this study is expected to be useful in predicting the spalling of high strength concrete columns.

Alpha spectrometry: Avoiding recoil contamination of solid state alpha detectors

  • C. Olondo;R. Idoeta;M. Herranz
    • Nuclear Engineering and Technology
    • /
    • v.56 no.11
    • /
    • pp.4661-4670
    • /
    • 2024
  • Due to its low background, alpha spectrometry is capable of determining very low activity concentrations of alpha emitters in all types of samples, including environmental samples. This low background can be lost due to detector contamination caused by recoil nuclei, which can even render the detector useless. In this paper, the thickness of a thin film used to cover the source is calculated analytically. This film, capable of retaining these nuclei and avoiding this contamination, allows all the alpha particles emitted by the source to reach the detector. The energy loss of the alpha particles passing through it was also estimated in order to identify the peaks in the spectrum, including the unexpected ones. The validity of the calculations carried out and the effectiveness of the film in retaining the recoil nuclei were verified using thorium samples. Finally, the effect of applying a negative potential to the source on the retention of these nuclei was studied. The study was carried out using a PIPS detector under vacuum conditions (0.1 mm Hg) with the samples placed at a distance of 5 mm from the detector. The recoil suppression systems of some commonly used commercial instruments were also tested.