• 제목/요약/키워드: Uncertainty of measurement

검색결과 918건 처리시간 0.025초

대전력시험에 사용되는 측정시스템의 평가 (The evaluation of measurement system for high power tests)

  • 이동준;정흥수;김원만;김선구;나대열;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.286-288
    • /
    • 2002
  • The rapid development of measurement systems for high power tests makes it possible to measure signals as well as analyze with the help of computer. Also, methods to evaluate such measurement systems are required recently. Uncertainty has been regarding as the most important factor in evaluating the measurement systems. Because of the character of the measurement systems for high power tests. the uncertainty shall be evaluated by each component. If the uncertainty evaluated by each component, it is convenient to evaluate total uncertainty of the measurement systems according to each component setting's combination. In this paper each component of high current measurement system of high power testing Dept. II in Korea Electrotechnology Research Institute is evaluated except sensors such as shunts and CTs. The total uncertainty of the measurement systems can be determined by that of each component including uncertainty of sensors.

  • PDF

피스톤 푸루버 개발 및 불확도 평가 (Development and Uncertainty Evaluation of Piston Prover)

  • 최해만;박경암
    • 한국유체기계학회 논문집
    • /
    • 제6권2호
    • /
    • pp.47-53
    • /
    • 2003
  • The piston prover was developed and the flow measurement uncertainty of this piston prover was evaluated according to ISO/IEC 17025. The laser interferometer, instead of the optical sensors used in the typical provers, was employed in this prover to measure accurately the testing time and the moved distance of the piston. Uncertainty was calculated with evaluation of various uncertainty factors affecting flow measurement. The expanded uncertainty (U) of the piston prover was $1.3{\times}10^{-3}$ (at the confidence level of $95\%$). This evaluation example will be useful in the flow measurement uncertainty determination of other gas flow measurement system.

측정 불확도에 따른 중량충격음 측정편차에 관한 연구 (Measurement uncertainty in heavy-weight floor impact sounds)

  • 유승엽;김용희;심명희;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.826-829
    • /
    • 2008
  • In a field measurement, measurement errors are produced by measuring environments and systematic errors in the measurement procedure. Measurement errors can be expressed as a measurement uncertainty. In this study, the measurement uncertainty and various measuring factors are investigated in heavy-weight impact sounds. According to KS 2810-2, the model functions, which is the estimation of the maximum SPL measurement in each octave band frequency, are determined. From this estimation model, 3.53dB is shown in 63Hz. This level is caused by the sound field of the receiving room, which does not meet the diffusing field.

  • PDF

고정밀 공작기계의 열적효과 측정 및 불확도 추정에 관한 연구 (A Study on the Thermal Effects Measurement and Uncertainty Estimation for High Precision Machine Tools)

  • 손덕수;김상화;박일환
    • 한국기계가공학회지
    • /
    • 제12권2호
    • /
    • pp.107-113
    • /
    • 2013
  • When the main spindle of high precision machine tools are run many hours, heat is generated in bearing parts of the inside of the spindle. Also, headstock is appeared distortion by inside and outside temperature difference of a machine. This paper studies method to measure behavior of machine tool about these thermal effects. In addition, it estimates measurement uncertainty factors which can be appeared in thermal effects measurement. Finding the factor of thermal affect measurement is important for estimation of measurement uncertainty. This paper measures thermal effects of high precision machine tools and evaluates the important factors of uncertainty.

공기열원 히트펌프의 에너지 효율 비율에 관한 실험적 연구 (An Experimental Study on the Energy Efficiency Ratio of Heat Pump for Air Source)

  • 정순영
    • 한국수소및신에너지학회논문집
    • /
    • 제33권6호
    • /
    • pp.838-844
    • /
    • 2022
  • In this paper, an experimental study was conducted on the energy efficiency ratio of performance for air source heat pump. The energy efficiency ratio presents the operating efficiency of heat pump performance. In order to improve reliability in the energy efficiency ratio test of air source heat pump, the measurement uncertainty of the instrument was estimated. Measurement uncertainty refers to the uncertainty of a measurement, estimates the range in which the expected value of the measurement can be within a certain confidence level, and suggests a range in which the measured representative value is incorrect. The measurement uncertainty for the energy efficiency ratio test of air source heat pump was calculated and the measured results were presented.

데오도라이트 시스템의 측정 불확도 연구 (A Study on Measurement Uncertainty of Theodolite System)

  • 이건탁;이동주;박흥철;오재명
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 춘계학술대회 논문집
    • /
    • pp.229-233
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is 0.5 mm or better for distance 0 ~ 100m. And the system is used for a product of middle and large scale. This study is performed for the measurement uncertainty of the system. We could know that the main uncertainty factors are temperature, illumination and skill. And, we perform the study for the effect according to the height difference of scale bar. And, we calculated the measurement uncertainty with those factors.

  • PDF

전기화학적 노이즈 저항 측정에서의 불확도 평가 (Uncertainty evaluation in electrochemical noise resistance measurement)

  • 김종집;강수연
    • Corrosion Science and Technology
    • /
    • 제12권5호
    • /
    • pp.220-226
    • /
    • 2013
  • The uncertainty in statistical noise resistance measurement was evaluated for a type 316 stainless steel in NaCl solutions at room temperature. Sensitivity coefficients were determined for measurands or variables such as NaCl concentration, pH, solution temperature, surface roughness, inert gas flow rate and bias potential amplitude. The coefficients were larger for the variables such as NaCl concentration, pH, inert gas flow rate and solution temperature, and they were the major factors increasing the combined standard uncertainty of noise resistance. However, the contribution to the uncertainty in noise resistance measurement from the above variables was remarkably low compared to that from repeated measurements of noise resistance, and thus, it is difficult to lower the uncertainty in noise resistance measurement significantly by lowering the uncertainties related with NaCl concentration, pH, inert gas flow rate and solution temperature. In addition, the uncertainty in noise resistance measurement was high amounting to 17.3 % of the mean, indicating that the reliability in measurement of noise resistance is low.

동전위 분극저항 측정에서의 불확도 (Uncertainty in Potentiodynamic Polarization Resistance Measurement)

  • 김종집
    • Corrosion Science and Technology
    • /
    • 제8권5호
    • /
    • pp.193-196
    • /
    • 2009
  • For the estimation of uncertainty in potentiodynamic polarization resistance measurement, the type A uncertainty was measured using type 316 stainless steel in an acidified NaCl solution. Sensitivity coefficients were determined for measurand such as scan rate of potential, temperature of solution, concentration of NaCl, concentration of HCl, surface roughness of specimen and flow rate of purging gas. Sensitivity coefficients were large for the measurand such as the scan rate of potential, temperature of solution and roughness of specimen. However, the sensitivity coefficients were not the major factors influencing the combined standard uncertainty of polarization resistance due to the low values of uncertainty in measurements of the measurands. A major influencing factor was the concentration of NaCl. The value of type A uncertainty was 1.1 times the value of type B uncertainty, and the combined standard uncertainty was 10.5 % of the average value of polarization resistance.

Application of Monte Carlo simulations to uncertainty assessment of ship powering prediction by the 1978 ITTC method

  • Seo, Jeonghwa;Park, Jongyeol;Go, Seok Cheon;Rhee, Shin Hyung;Yoo, Jaehoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제13권1호
    • /
    • pp.292-305
    • /
    • 2021
  • The present study concerns uncertainty assessment of powering prediction from towing tank model tests, suggested by the International Towing Tank Conference (ITTC). The systematic uncertainty of towing tank tests was estimated by allowance of test setup and measurement accuracy of ITTC. The random uncertainty was varied from 0 to 8% of the measurement. Randomly generated inputs of test conditions and measurement data sets under systematic and random uncertainty are used to statistically analyze resistance and propulsive performance parameters at the full scale. The error propagation through an extrapolation procedure is investigated in terms of the sensitivity and coefficient of determination. By the uncertainty assessment, it is found that the uncertainty of resultant powering prediction was smaller than the test uncertainty.

버어리종 담배 중 질산성 질소에 대한 측정불확도 (Uncertainty of Measurement in Nitrate Analysis from Burley Leaf Tobacco)

  • 이정민;이경구;한상빈
    • 한국연초학회지
    • /
    • 제27권2호
    • /
    • pp.226-234
    • /
    • 2005
  • The uncertainty of measurement in nitrate from burley leaf tobacco by continuous-flow analysis method was evaluated following internationally accepted guidelines. The sources of uncertainty associated with the analysis of nitrate were weight of standard and sample, purity of standard, dilution of standard solution, calibration curve, water content, etc. The calculation of uncertainty based on the GUM(Guide to the Expression of Uncertainty in Measurement) and EURACHEM/CITAC Guide. An expanded uncertainty was obtained by multiplying the combined standard uncertainty with a coverage factor (k) calculated from the effective degree of freedom. The concentration of nitrate from burley leaf tobacco was $2.09\%$ and the expanded uncertainty by multiplying by the coverage factor(k, 2.20) was $0.13\%\;at\;a\;95\%$ confidence level.