• Title/Summary/Keyword: Unbalance factor

검색결과 115건 처리시간 0.024초

전압불평형의 표현방식에 관한 연구(II) - 전압불평형계수의 근사적 표현방식 - (A Study on the Representation of Voltage Unbalance: Part II-Approximations of Voltage Unbalance Factor)

  • 정승기
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권5호
    • /
    • pp.263-270
    • /
    • 2003
  • In field applications, to represent the degree of voltage unbalance, the maximum voltage deviation from the average is preferred to the voltage unbalance factor based on symmetrical component analysis. This paper first clarifies the relationship between the voltage unbalance factor and the maximum deviation factor showing that the maximum deviation factor approximates the voltage unbalance factor under relatively low unbalanced conditions. Several alternative ways of approximation are introduced and examined by comparing with the conventional maximum deviation factor. It appears that these alternatives provide more accurate approximation to the voltage unbalance factor over wider range of voltage unbalance while maintaining simplicity in their formula.

부하 변동에 의한 전압불평형율의 특성 해석 (Analysis on the Characteristics of Voltage Unbalance Factor by Load Variations)

  • 김종겸;박영진;이은웅
    • 전기학회논문지P
    • /
    • 제54권1호
    • /
    • pp.47-53
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Voltage unbalance factor is mainly affected by load system rather than stable power system. Unbalanced voltage will draw a highly unbalanced current. As a result, the three-phase currents may differ considerably, thus resulting in an increased temperature rise in the machine. This paper presents a scheme on the characteristics of voltage and current unbalance factor under the load variation at the three phase 4-wire system. Load unbalance factor is measured by the power quality measurement apparatus and compared by the current unbalance factor. Two methods are indicated similar results. The voltage unbalance factor of the three-phase 4-wire system is approved by the field measurement. Each phase has an impedance each other by the unbalanced operation pattern and give rise to voltage unbalance.

전압불평형의 표현방식에 관한 연구(I) - 선간전압 크기에 의한 불평형계수의 표현 - (A Study on the Representation of Voltage Unbalance: Part I-Voltage Unbalance Factor in terms of Line Voltage Magnitudes)

  • 정승기
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권5호
    • /
    • pp.257-262
    • /
    • 2003
  • The voltage unbalance factor derived from symmetrical component analysis requires manipulation of complex quantities. To facilitate the calculation of the voltage unbalance factor in field applications, this paper proposes the method for calculating the voltage unbalance factor in terms of the line voltage magnitudes that are readily available in moat practical circumstances. It is shown that the line voltages appear as circular Phasor loci for given voltage unbalance factor, and a graphical chart is developed that can be used to determine the voltage unbalance factor in a straightforward manner avoiding calculation.

부하 불평형율에 대한 새로운 해석 (A New Analysis for Load Unbalance Factor)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제55권2호
    • /
    • pp.67-72
    • /
    • 2006
  • Most of the load distributions in low voltage power feeder distribution systems are designed with approximately balanced and connected at the three phase four wire systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating load unbalance. Load unbalance factor is mainly affected by the impedance of load system. Unbalanced current will draw a highly unbalanced voltage. This paper presents a new calculation method for unbalance factor under the load variation at the three phase four wire system. Load unbalance factor is measured by the power quality measurement apparatus and compared with the current unbalance factor. Two methods are indicated similar results.

선간전압과 상전압에 대한 전압불평형율의 비교 (Comparison of Voltage Unbalance Factor for Line and Phase Voltage)

  • 김종겸;박영진;이은웅
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권9호
    • /
    • pp.403-407
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, voltage unbalance is generated at the user's 3-phase 4-wire distribution systems with single & three phase. Voltage unbalance is mainly affected by load system rather than power system. Unbalanced voltage will draws a highly unbalanced current and results in the temperature rise and the low output characteristics at the machine. It is necessary to analyse correct voltage unbalance factor for reduction of side effects in the industrial sites. Voltage unbalance is usually defined by the maximum percent deviation of voltages from their average value, by the method of symmetric components or by the expression in a more user-friendly form which requires only the three line voltage readings. If the neutral point is moved by the unbalanced load at the 3-phase 4-wire system. Line and phase voltage unbalance leads to different results due to zero-sequence component. So that it is difficult to analyse voltage unbalance factor by the conventional analytical method, This paper presents a new analytical method for phase and line voltage unbalance factor in 4-wire systems. Two methods indicate exact results.

전압불평형율의 현장측정 및 분석 (Field Measurement and Analysis of Voltage Unbalance Factor)

  • 정종호;박영진;이은웅;김종겸
    • 전기학회논문지P
    • /
    • 제54권1호
    • /
    • pp.41-46
    • /
    • 2005
  • Most of LV customer have applied the 3-phase four wire system distribution system because it has advantage of supplying both of 1-phase & 3-phase loads simultaneously. Due to its structural simplicity, it is more convenient for use rather than the conventional separated scheme. But voltage unbalance more commonly emerges in individual customer loads due to phase load unbalance, especially where, single-phase power loads are used. Voltage unbalance factor(VUF) represents the loss of symmetry in the supply(magnitude and angle). It leads some problems such as de-rating or power losses. In this paper, voltage and current waveform in the actual fields have been measured and analyzed in relation with internationally allowable voltage unbalance limits.

전압, 전류 및 부하 불평형율에 대한 비교 연구 (The Comparison Study for Voltage, Current and Load Unbalance Factor)

  • 김종겸;박영진;이은웅
    • 전기학회논문지P
    • /
    • 제54권2호
    • /
    • pp.88-93
    • /
    • 2005
  • Most of the LV customer have been applied the distribution system of 3-phase four wire system because of its advantage of supplying both of 1-phase & 3-phase loads simultaneously. Due to its structural simplicity, it is more convenient for use rather than the conventional separated scheme. But uneven load distribution or unclean voltage quality has occurred various problems such as de-rating, losses increase and vibration, etc. In this paper, voltage, current and power waveform in the actual fields have measured and analyzed in relation with internationally allowable voltage unbalance limits and compared the current unbalance factor with the load unbalance factor.

3상 4선식 부하설비의 전압, 전류 및 부하 불평형율 측정 분석 (The measurement & Analysis of Voltage, Current and Load Unbalance Factor at Three Phase Four Wire Load System)

  • 김종겸;박영진;이동주;이종한;정종호;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.28-30
    • /
    • 2005
  • This paper presents a scheme on the characteristics of voltage and current unbalance factor under the load variation at the three phase 4-wire system. The voltage unbalance factor of the three-phase 4-wire system is approved by the field measurement. This system is composed of three one-phase transformer with each other capacity. Current unbalance factor is measured by the power quality measurement apparatus and compared by the load unbalance factor. Each phase has an impedance each other by the unbalanced load operation pattern and give rise to voltage unbalance.

  • PDF

Input Current Characteristics of a Three-Phase Diode Rectifier with Capacitive Filter Under Line Voltage Unbalance Condition

  • Jeong Seung-Gi;Lee Dong-Ki;Park Ki-Won
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.808-815
    • /
    • 2001
  • The three-phase diode rectifier with a capacitive filter is highly sensitive to line voltage unbalance, and may cause significantly unbalanced line currents even under slightly unbalanced voltage condition. This paper presents an analysis of this 'unbalance amplification' effect for an ideal rectifier circuit without ac-and dc-side inductors. The voltage unbalance is modeled by introducing a deviation voltage superimposed on balanced three-phase line voltages. With proper approximations, closed-form expressions for symmetrical components of the line current and current unbalance factor are derived in terms of the voltage unbalance factor, filter reactance, and load current. The validity of analytical predictions is confirmed by simulation.

  • PDF

전원 불평형과 역률을 보상하는 직렬형 능동전력필터의 통합적 제어 (Integrative Control of Series Active Power Filters for Source Voltage Unbalance Compensation and Power Factor Correction)

  • 장정익;석줄기;이동춘
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권5호
    • /
    • pp.258-264
    • /
    • 2006
  • This paper presents an integrative control scheme for series-type active power filters combined with shunt passive filters not only to compensate for the source voltage unbalance and current harmonics but also to correct the power factor. To reduce the power capacity of the active filters, passive filters are connected in parallel. Diode rectifiers are replaced by the PWM converters in order to feed the real power back to the source. Power factor control is performed by changing the phase of the load voltage so that the phase of the source current coincides with that of the source voltage. The resultant voltage reference is the addition of the voltage component compensating for the source voltage unbalance and harmonic currents and the voltage component correcting the power factor. The validity of the proposed algorithm has been verified by experimental results.