• 제목/요약/키워드: Unbalance and nonlinear load

검색결과 34건 처리시간 0.023초

불평형 부하에서 강인한 3상4족 전압형 인버터를 위한 하이브리드 제어기의 설계 (Design of the Robust Hybrid Controller for Three-Phase Four-Leg Voltage Source Inverter under the Unbalance Load)

  • 도안반투안;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.291-292
    • /
    • 2014
  • The three-phase four-leg voltage source inverter (VSI) topology can be an interesting option for the three phase-four wire system. With an additional leg, this topology can achieve superior performance with unbalanced and/or nonlinear load. This paper proposes a new hybrid controller which combines PI controller and resonant controller in synchronous frame for three phase four leg inverter. The hybrid controller is simple in structure and easy to implement. The performance of proposed controller is verified by the experiments and compared with that of the conventional PI controller.

  • PDF

단상 변압기 지그재그 결선에 의한 3고조파 전류 저감 효과 분석 (Analysis of Reduction Effect of Three Harmonic Currents by Zigzag Wiring of Single Phase Transformer)

  • 김종겸;김지명
    • 전기학회논문지P
    • /
    • 제66권3호
    • /
    • pp.99-104
    • /
    • 2017
  • The three-phase four-wire power distribution system can be used to supply power to single-phase and three-phase loads at the same time. There are linear loads and nonlinear loads as single-phase loads connected to each phase. The nonlinear load generates a harmonic current during the power energy conversion process. In particular, the single-phase nonlinear load has a higher proportion of generation of the third harmonic current than the harmonics of the other orders. In a three-phase four-wire system, the third harmonic current flows through the neutral wire to the power supply side, affecting the power supply side and the line. Furthermore, the magnitude of the current flowing in the neutral line can be higher than the current flowing in the individual phase. If the neutral current is higher than the phase current, the breaker may be blocked. Therefore, it is necessary to reduce the amount of current flowing in the neutral line by harmonics. There is a method of zigzag connecting a single phase transformer by a method of reducing 3 harmonic current. In this study, the method of reducing the magnitude of the three harmonic currents flowing through the zigzag wire by comparing the polarity and the negative polarity characteristics of the single phase transformer was compared through measurement and simulation.

대부하 표적지향 시스템의 정밀 제어 기법 연구 (A Study on Precision Control of a Heavy Load Pointing System)

  • 김병운;강이석
    • 제어로봇시스템학회논문지
    • /
    • 제10권9호
    • /
    • pp.840-846
    • /
    • 2004
  • In this study, the performance of a heavy load pointing system has been investigated. The PI controller are being widely used in industrial application because of simple, cheap, and excellent performance. However, the requirement for control precision becomes higher and higher, as well as the plants becomes more and more complex. In order to achieve the satisfied control performance, we have to consider the affection of nonlinear factor contained in plant. In this paper, the neural-PI control law have been evaluated. The proposed controller is compared with the existing controllers through simulations, and the results show that the pointing accuracy of the proposed control system is improved against the disturbance induced by vehicle running on the bump course.

가변 전류루프이득을 가지는 Power Conditioner (Power Conditioner with Variable Current Loop Gain)

  • 정창용;이영운;백주원;유동욱;안창모;조기연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1101-1104
    • /
    • 2001
  • This paper describes a newly developed power conditioner with variable current loop gain. The power conditioner consists of a do-link capacitor and three phase inverter with coupled inductor. This system is very well operated to compensate current harmonics and asymmetries caused by nonlinear load and unbalance loads. The power conditioner shapes the source current sinusoidal in phase with source voltage. A 100kVA power conditioner was built and the controller is realized with DSP Experimental results for many load conditions are presented to verify the performance of the controller.

  • PDF

맥동 전압 추출을 통한 배전용 정지형 보상기의 직류링크 전압제어 (DC-Link Voltage Control of Distribution Static Compensator using Ripple Voltage Extraction)

  • 김호열;최종우
    • 전력전자학회논문지
    • /
    • 제17권1호
    • /
    • pp.8-13
    • /
    • 2012
  • DSTATCOM is active filter that reduces nonlinear and unbalanced currents. Researches about DSTATCOM are mainly divided two parts, one is the reference value calculation of compensation current depending on the calculation of the load-side average active power and dc-link capacitor average voltage, the other part is actual current control depending on the reference value of compensation current. This paper proposes a calculation of dc-link capacitor average voltage ripple voltage extraction instead of conventional method using LPF. The utility of the proposed algorithm is verified through the theoretical analysis and the experiment under unbalance loads and non-linear load.

조합 유전 알고리듬을 이용한 항공기 엔진 시스템의 최적설계 (Optimal Design of Aircraft Gas Turbine System supported by Squeeze Film Damper Using Combined Genetic Algorithm)

  • 김영찬;안영공;양보석;길병래
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.514-519
    • /
    • 2003
  • The aircraft engine is usually supported by rolling element bearings and has a small damping rate, which is vol y sensitive to external force. The high-performance requirement of the rotors leads to complex assembly designs and are more flexible. Squeeze film dampers (SFDs) are introduced to provide damping while crossing the critical speeds and stability to the rotor s :stem. Hence, the focus of the present investigation is on the decision of an optimal size of the flexible rotor system supported by the squeeze film dampers to minimize the maximum transmitted load and unbalance response over a range operating speeds. The enhanced genetic algorithm (EGA), which was developed by authors, is used in the optimization process. This algorithm is based on the synthesis of a modified genetic algorithm and simplex method. The results show significant benefits in using EGA when compared with nonlinear programming (NLP).

  • PDF

베어링 Span을 고려한 저널 베어링의 동특성 해석 (Dynamic Characteristics of Journal Bearings Considering Bearing Span)

  • 윤진욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.906-910
    • /
    • 2003
  • This paper numerically analyzes the dynamic characteristics of a spindle system supported by two identical journal bearings considering bearing span that has dynamic load due to its mass unbalance. The Reynolds equation is transformed to solve a herringbone grooved journal bearing. The Reynolds equations are solved using FEM in order to calculate the pressure distribution in a fluid film. Reaction forces and friction torque are obtained by integrating the pressure and shear stress along the fluid film, respectively. Dynamic behaviors, such as whirl radius or angular displacement of a rotor, are determined by solving its nonlinear equations of motion with the Runge-Kutta method. This research shows that the same bearing spans of upper and lower journal bearings produce the minimum runout and friction torque of a spindle system.

  • PDF

베어링 Span을 고려한 저널 베어링의 동특성 해석 (Dynamic Characteristics of Journal Bearings Considering Bearing Span)

  • 윤진욱
    • 한국소음진동공학회논문집
    • /
    • 제14권9호
    • /
    • pp.779-784
    • /
    • 2004
  • This paper numerically analyzes the dynamic characteristics of a spindle system supported by two identical journal bearingsconsidering bearing span that has dynamic load due to its mass unbalance. The Reynolds equation is transformed to solve a herringbone grooved journal bearing. The Reynolds equations are solved using FEM in order to calculate the pressure distribution in a fluid film. Reaction forces and friction torque are obtained by integrating the pressure and shear stress along the fluid film, respectively. Dynamic behaviors, such as whirl radius or angular displacement of a rotor, are determined by solving its nonlinear equations of motion with the Runge-Kutta method. This research shows that the same bearing spans of upper and lower journal bearings produce the minimum runout and friction torque of a spindle system.

Power Quality Compensating System Using Series Active Power Filter

  • Kwon Hyoung-Nam;Gho Jae-Sok;Choe Gyu-Ha;Kim Hong-Sung;Han Suk-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.606-610
    • /
    • 2001
  • Voltage harmonics resulting from current harmonics produced by the nonlinear loads have become a serious problem in many systems. Moreover momentary interruptions and voltage sags are responsible for many of the power quality problems found in typical industrial plants. In this paper, proposed power system using series active power filter is not only harmonic compensation but also harmonic isolation between supply and load, and voltage regulation and unbalance compensation. The effectiveness of the proposed system is verified through computer simulations and experiments

  • PDF

능동필터 겸용 무정전 전원장치 (Parallel processing of an active filter and a UPS)

  • 강유리;김원호;김종수;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.550-552
    • /
    • 1994
  • Recently, various activ filters such as current type and voltage type have been proposed to suppress harmonics caused by nonlinear load due to the use of semiconductor switching devices. At the early stage, active filters are used only to suppress harmonics. However, it has been proposed that they offer more functions such as voltage regulations, improvements of power factor and 3 phase unbalance. This study presents a combined function of active filter and a UPSs with one power processing stage.

  • PDF