• Title/Summary/Keyword: Ultraviolet lamp

Search Result 109, Processing Time 0.028 seconds

A Study of Characteristic of Oriental Herbal Medicine Storage System using Ozone Lamp (오존램프를 이용한 한약재 저장 장치의 특성 연구)

  • Woo, Sung-Hun;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.98-103
    • /
    • 2007
  • We made a oriental herbal medicine storage system and studied a preservation characteristic of oriental herbal medicine in this research. The lamp(OZ-Lamp) in a storage system is the low pressure ultraviolet lamp which radiates the sterilizing and ozonic rays. We made research ozone generation and electric discharge characteristic of a oriental herbal medicine storage system, which have radiation feature of ultraviolet rays of a short wavelength to be happened in the electric discharge. Also, we made research an ingredient and quality characteristic of oriental herbal medicine according to ozone treatment storage.

Design Method for Flowing Water Purification with UV Lamp (UV램프를 이용한 유수처리형 살균장치의 설계방법)

  • Jung, Byung-Kyun;Lee, Jin-Jong;Jeong, Byeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.455-460
    • /
    • 2009
  • A number of factors combine to make ultraviolet radiation a superior means of water purification for ground water, rainwater harvesting systems and so on. Ultraviolet radiation is capable of destroying all types of bacteria. Additionally, ultraviolet radiation disinfects rapidly without the use of heat or chemical additives which may undesirably alter the composition of water. In a typical operation, water enters the inlet of a UV lamp and flows through the annular space between the quartz sleeve and the outside chamber wall. The irradiated water leaves through the outlet nozzle. Several design features are combined to determine the dosage delivered. The first is Wavelength output of the lamp, the Second is Length of the lamp - when the lamp is mounted parallel to the direction of water flow, the exposure time is proportional to the length of the lamp, the third is Design water flow rate - exposure time is inversely related to the linear flow rate, the forth is Diameter of the purification chamber - since the water itself absorbs UV energy, the delivered dosage diminishes logarithmically with the distance from the lamp. In this paper, It describe the how to design optimal UV disinfection device for ground water and rainwater. To search the optimal design method, it was performed computer simulation with 3D-CFD discrete ordinates model and manufactured prototype. Using proposed design method manufactured prototype applied to disinfection test and proved satisfied performance.

A New Xenon Plasma Flat Fluorescent Lamp Enhanced with MgO Nano-Crystals for Liquid Crystal Display Applications

  • Lee, Yang-Kyu;Heo, Seung-Taek;Lee, You-Kook;Lee, Dong-Gu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.4
    • /
    • pp.186-189
    • /
    • 2010
  • Nano-sized MgO single crystal powders have recently been reported to emit ultraviolet by stimulation of electrons in a vacuum. In this study, nanocrystalline MgO powders were applied to a xenon plasma flat fluorescent lamp (FFL) for a liquid crystal display backlight to improve its emission efficiency through the extra ultraviolet from the nano-MgO crystals. For comparison, a MgO nano-thin film was applied directly on the phosphors inside a lamp panel through e-beam evaporation. Adding MgO nano-crystal powders to the phosphors improved the luminance and efficiency of FFLs by around 20% and MgO nano-crystal coverage of 40% of the phosphor provided the best FFL emission characteristics; however, application of MgO thin film to the phosphors degraded the emission characteristics, even compared to FFLs without MgO. This was due to insufficient ultraviolet stimulation of the phosphors and the crystallinity and low secondary electron coefficient of the MgO.

High Power Factor Electronic Ballast for Ultraviolet Germicidal Lamp (자외선 살균 램프용 고역률 전자식 안정기에 관한 연구)

  • Kang, Bum-Suk;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1202-1205
    • /
    • 2000
  • Germicidal lamps efficiently emit a large amount of ultraviolet rays 253.7nm which have excellent germicidal effect. The lamps are primarily useful for sterilization of air, the surface of various materials and water or liquid. In this paper, analysis of the charge pump power factor correction inverter for driving a 65W UV lamp and electrical characteristics of the lamp are discussed. The operation of the inverter circuit. in which the lamp is included as a load, is analyzed. Experimental results of the inverter circuit are also presented.

  • PDF

Measurement Technique of Ozone Density by Using UV Sensor System

  • Trung, Nguyen Huu;Van Men, Le;Van Hieu, Nguyen
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.80-86
    • /
    • 2015
  • There are many studies and products using a test paper impregnated with chemical solution can react with ozone. The color of a test paper can indicate the concentration of ozone. The purpose of this research is to design and manufacture a system using ultraviolet light source to measure the ozone density. This new technique is based on the characteristic of decomposition from ozone into oxygen under ultraviolet light. We used two sources of ultraviolet light including UV lamp and UVLED to determine the decomposition of ozone. This system is built with the electronic components, sensors and sealed pump tube to measure the ozone density in units of $g/cm^3$,ppm,ppb. In this paper,, we present some initial results of measuring the ozone density from ozone generator after completing inspection for safety.

The Research of Electrical and Optical Properties for 24″ Flat Panel-Florescent Lamp (24″평판형광램프에 관한 전기적광학적특성연구)

  • 김수용;박승곤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.527-530
    • /
    • 2001
  • In this paper, the basic characteristics of flat fluorescent lamp using ultraviolet generate from gas discharge and powder type electrolyminescent display(P-ELD) using a phenomenon of the light emission eaused by the electrical field applied to phosphor are studied. The lamp is a simple structure with insulator layer, phosphor layer, and gas gap. Current(displacement current + discharge current) in flat fluorescent lamp using.

  • PDF

Ultraviolet Lamp Replacement Period and Hygiene Management Plan of Ultraviolet Sterilizer (자외선 살균고의 자외선 램프 교체 주기와 위생관리 방안)

  • Young-Ju Lee;Ju-Hyun Lee;Eun-Sol Go;Jung-Beom Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.1
    • /
    • pp.26-30
    • /
    • 2023
  • In this study, we analyzed the microbial contamination level of ultraviolet sterilizer (UVS) chambers and suggested plans to improve hygiene management. In this study, UVS chambers targeted 98 UVS in some childcare centers in Jeollanam-do, Korea. Total aerobic bacteria and coliform bacteria were tested according to the Korean Food Code. Of the 98 UVS chambers, total aerobic bacteria were detected in 67 (68.4%) and coliform bacteria in 5 (5.1%). Six kinds of food-poisoning bacteria, including Salmonella spp., were not detected, but Bacillus cereus was detected in 1 (2.8%) out of 98 UVS chambers. According to the UV lamp replacement period, the detection rate of total aerobic bacteria was 3 (50%) out of 6 UVS within 3 months, 3 (60%) out of 5 UVS in 3 to 6 months, and 61 (70.1%) out of 87 UVS over 6 months. The detection rate of coliform bacteria according to the UV lamp replacement period was not detected within 6 months, however, they were detected in 5 (5.7%) out of 87 chambers after more than 6 months. The level of microbial contamination in the UVS chambers was higher as the lamp replacement period was longer. Considering these results, it was determined that the UVS chambers should be kept dry and clean, and the UV lamp should be replaced periodically. In addition, it is necessary to provide the staff catering for childcare centers with continuous education regarding the cleaning of UVS chambers and the replacement of UV lamps.

Surface Discharge Characteristics of New Flat Fluorescent Lamp Enhanced by MgO Nano-Crystals

  • Lee, Yang-Kyu;Heo, Seung-Taek;Lee, You-Kook;Lee, Dong-Gu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.687-690
    • /
    • 2009
  • It has been recently reported that nano-sized MgO single crystal powders emit ultraviolet by stimulation of electrons under vacuum condition. Therefore, in this study, nano-crystalline MgO powders were applied to a xenon plasma flat fluorescent lamp for LCD backlight to improve emission efficiency of the lamp by help of extra ultraviolet from nano-MgO. For comparison with nano-crystalline MgO powders, MgO nano-thin film was applied directly on phosphors inside a lamp panel through e-beam evaporation The luminance and efficiency of FFL with an addition of MgO nano-crystal powders on phosphors were improved by around 20%. Application of MgO thin film to phosphors worsened the emission characteristics of FFLs, even rather than FFL without MgO. The reason came from insufficient stimulation of phosphors by UV, crystallinity of MgO, and low secondary electron coefficient.

  • PDF

A Study on Electrical and Optical Charateristics of Flat Fluorescent Lamp (평판형광램프 전기적광학적 특성 연구)

  • Kim, Soo-Yong;Lee, Oh-Keol
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1792-1794
    • /
    • 2001
  • In this paper, the basic characteristics of flat fluorescent lamp using ultraviolet generated from gas discharge and powder type electro luminescent display using a phenomenon of the light emission caused by the electrical field applied to phosphor are studied. The lamp is a simple structure with insulator layer, phosphor layer, and gas gap. Current(displacement current + discharge current) in flat fluorescent lamp using.

  • PDF

A clean technology development using the molybdenum dissolution reaction with hydrogen peroxide/UV/Ozone ($오존/UV/H_2O_2$를 이용한 몰리브덴(Mo) 용해 반응에 따른 청정기술 개발에 관한 연구)

  • 김재우;홍종순;신대윤
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.143-149
    • /
    • 1999
  • In the tungsten industry as light source material, tungsten filament which used as light source material could form after molybdenumwire which used as the center supporter for coil shape tungsten wire was removed. This process uses hydrogen peroxide, Ozone and UV(Ultraviolet)Lamp, for the quantity of hydrogen peroxide decrease. The results were as follows : 1. An incandescent electric Lamp type : FL(FL-20) type : A standard of commodity (P.W.: $19{\pm}1.0mg$, $C.R:4.5{\pm}0.3{\Omega}$) 1) Only hydrogen peroxide treated ; Reaction Time : 65Min., P.W.: 18.60mg, $C.R.:4.60{\Omega}$ 2) Ozone/Ultraviolet/70% of hydrogen peroxide; Reaction Time : 64Min., P.W.: 18.61mg, C.R.: $4.61{\Omega}$ 2. A Fluorescent Lamp Type : GLS(GLS-40) Type : A standard of commodity(P.W.: $11.8{\pm}0.2mg$$65{\pm}1.5{\Omega}$) 1) Only hydrogen peroxide treated ; Reaction Time: 72Min, P.W.:11.88mg, C.R.: $65.62\Omega$ 2) Ozone/Ultraviolet/70% of hydrogen peroxide;Reaction Time:71Min., P.W.:11.88mg, C.R.: $65.63\Omega$

  • PDF