• Title/Summary/Keyword: Ultraviolet detection

Search Result 145, Processing Time 0.027 seconds

Tidal Dwarf Galaxies around a Post-Merger Galaxy, NGC 4922

  • Sheen, Yun-Kyeong;Jeong, Hyun-Jin;Yi, Suk-Young K;Ferreras, Ignacio;Lotz, Jennifer M.;Olsen, Knut A.G.;Dickinson, Mark;Barnes, Sydney;Lee, Young-Wook;Park, Jang-Hyun;Ree, Chang-H.
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.35.2-35.2
    • /
    • 2009
  • One possible channel for the formation of dwarf galaxies involves birth in the tidal tails of interacting galaxies. We report the detection of a bright UV tidal tail and several young tidal dwarf galaxy candidates in the post-merger galaxy NGC 4922 in the Coma cluster. Based on a two-component population model (combining young and old stellar populations), we find that its light predominantly comes from young stars (a few Myr old). The Galaxy Evolution Explorer (GALEX) ultraviolet data played a critical role in the parameter (age and mass) estimation. Our stellar mass estimates of the tidal dwarf galaxy candidates are ~10^{6-7} M_sun, typical for dwarf galaxies.

  • PDF

Simultaneous Quantitative Determination of Monosaccharides Including Fructose in Hydrolysates of Yogurt and Orange Juice Products by Derivatization of Monosaccharides with p-Aminobenzoic Acid Ethyl Ester Followed by HPLC

  • Ko, Joung-Ho;Huang, Huazi;Kang, Gyoung-Won;Cheong, Won-Jo
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.10
    • /
    • pp.1533-1538
    • /
    • 2005
  • We have determined the contents of monosaccharides in the hydrolysates of some yogurt and orange juice products by derivatizing monosaccharides with p-aminobenzoic acid ethyl ester (ABEE). The separation of the ABEE-derivatized monosaccharides was efficiently carried out by HPLC using a microcolumn packed with the Alltima $C_{18}$ stationary phase. The concentrations of monosaccharides were determined based on the measured peak area/height counts. ABEE derivatization of fructose and its detection have never been successfully carried out before this work. In this study, two peaks were observed in a fixed ratio for ABEE-fructose, and the ratio was maintained over a wide range of fructose concentration. In order to prove the validity of the above method, we compared the concentrations of glucose, galactose and fructose determined by ABEE derivatization and UVD (ultraviolet detector) chromatography with those determined by RID (refractive index detector) chromatography without derivatization. The determined concentrations of monosaccharides obtained from the two chromatographic methods were found close to each other within acceptable error ranges.

Quantitation of Mevinolinic Acid in Human Plasma by HPLC (고속액체크로마토그래피를 이용한 사람 혈장중 메비놀린 산의 정량)

  • Oh, Han-Suk;Park, Dong-Young;Seo, Sung-Hoon;Kim, Young-Gwan;Hong, Seon-Pyo;Choi, Young-Wook;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.4
    • /
    • pp.279-282
    • /
    • 2000
  • Simple and precise high-performance liquid chromatographic (HPLC) assay was developed and validated for the determination of a HMG-CoA reductase inhibitor, $lovastatin^{TM}$ and its active metabolite (mevinolinic acid) in human plasma. The method involved solid phase extraction of mevinolinic acid and internal standard using Sep-Pak Cartridge. Samples were analyzed by reversed-phase HPLC using $Capcell-Pak\;C_{18}$ column with ultraviolet detection at 238 nm. The quantitation limit of mevinolinic acid was 2 ng/ml and the calibration curve was linear over the range of 2-50 ng/ml $(r^2>0.999)$ with human plasma. The analyses of quality control samples indicated that the normal values could be predicted with an accuracy >97%. The intra- and inter-day coefficients of variation for the analyses were <10%. The average recoveries were similar (79%) for mevinolinic acid and methylmevinolinic acid. The method described has been successfully applied to the quantification of mevinolinic acid in about 1,000 human plasma samples over six-month period.

  • PDF

Comparative bioavailability of synthetic vitamin C and Nutra-C (calcium ascorbate) in Korean healthy volunteers

  • Choi, Kyung-Mi;Hoon, Kim Man;Won, Hwang Tae;Kim, Jong-Dae;Park, Keum duck;Kim, Mi-Young;Jung, Young-Rim;Shin, Hye-Seoung
    • Analytical Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.162-169
    • /
    • 2016
  • The purpose of this study was to compare the relative bioavailability of synthetic Vitamin C and Nutra-C® (calcium ascorbate) using a randomized parallel pharmacokinetics study design. Under fasting conditions, 20 healthy volunteers were randomly allocated to receive a single oral dose (500 mg of ascorbic acid) of either synthetic Vitamin C or Nutra-C®. Fasting blood was collected pre-dose and 1, 2, 3, 4, 7 and 10 hr post-dose. The ascorbic acid content of human serum was determined using HPLC with ultraviolet detection. The fasting serum ascorbic acid concentrations of synthetic Vitamin C and Nutra-C® were 6.734 ± 2.09 ng/mL (n = 10) and 7.542 ± 2.96 ng/mL (n = 10), respectively. The bioavailability of Nutra-C® was significantly greater (128 %, p < 0.05) than that of the synthetic Vitamin C.

Fate and Characteristics of Dissolved Organic Matters in a Water Reclamation Facility, Korea (하수처리수 재이용시설의 공정별 용존유기물질 거동 및 특성)

  • Kwon, Eun-Kwang;Lee, Wontae
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.5
    • /
    • pp.355-362
    • /
    • 2021
  • This study investigated the fate of dissolved organic matter (DOM) in a water reclamation facility (WRF) in Korea. The WRF consists of coagulation, sedimentation, microfiltration, and reverse osmosis (RO) components. The production capacity of WRF is 90,000 m3/day. The reclaimed water is reused as industrial water. We also characterized DOM in raw, processed, and finished waters based on analysis of dissolved organic carbon (DOC), ultraviolet absorbance at 254 nm (UVA254), fluorescence excitation emission matrix (FEEM), and DOC fractions via liquid chromatography-organic carbon detection (LC-OCD). Based on the results of DOC, UVA254, and FEEM analyses, neither the coagulation/sedimentation nor the microfiltration at the WRF effectively removed DOM. The RO process removed more than 94% of DOM. The raw water (i.e., secondary treated effluent obtained from a wastewater treatment plant) exhibited tryptophan-like peaks, which are a promising marker of wastewater, in the FEEM analysis. Coagulation and microfiltration failed to eliminate the wastewater marker, whereas RO completely removed it. The raw water also carried high levels (89.4%) of hydrophilic and low-molecular weight substances, which are difficult to remove via coagulation-sedimentation or microfiltration. Humic substance was a major component of the hydrophilic fractions. Based on the LC-OCD analysis, RO effectively removed the humic and polymeric materials from DOM.

Chromophorylation of a Novel Cyanobacteriochrome GAF Domain from Spirulina and Its Response to Copper Ions

  • Jiang, Su-Dan;sheng, Yi;Wu, Xian-Jun;Zhu, Yong-Li;Li, Ping-Ping
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.2
    • /
    • pp.233-239
    • /
    • 2021
  • Cyanobacteriochromes (CBCRs) are phytochrome-related photoreceptor proteins in cyanobacteria and cover a wide spectral range from ultraviolet to far-red. A single GAF domain that they contain can bind bilin(s) autocatalytically via heterologous recombination and then fluoresce, with potential applications as biomarkers and biosensors. Here, we report that a novel red/green CBCR GAF domain, SPI1085g2 from Spirulina subsalsa, covalently binds both phycocyanobilin (PCB) and phycoerythrobilin (PEB). The PCB-binding GAF domain exhibited canonical red/green photoconversion with weak fluorescence emission. However, the PEB-binding GAF domain, SPI1085g2-PEB, exhibited an intense orange fluorescence (λabs.max = 520 nm, λfluor.max = 555 nm), with a fluorescence quantum yield close to 1.0. The fluorescence of SPI1085g2-PEB was selectively and instantaneously quenched by copper ions in a concentration-dependent manner and exhibited reversibility upon treatment with the metal chelator EDTA. This study identified a novel PEB-binding cyanobacteriochrome-based fluorescent protein with the highest quantum yield reported to date and suggests its potential as a biosensor for the rapid detection of copper ions.

Liquid chromatographic enantioseparation of several amino acids as nitrobenzoxadiazole derivatives on polysaccharide trisphenylcarbamate derived chiral stationary phases

  • Suraj Adhikari;Alisha Bhandari;Wonjae Lee
    • Analytical Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.143-151
    • /
    • 2023
  • Considering the greater role of α-amino acids in our daily lives, the enantiomer resolution of seven α-amino acids derivatized with fluorogenic reagent (4-fluoro-7-nitro-2,1,3-benzoxadiazole, NBD-F) by chiral HPLC on amylose or cellulose trisphenylcarbamate derived chiral stationary phases (CSPs) under simultaneous ultraviolet (UV) and fluorescence (FL) detection was performed. The degree of enantioseparation and resolution was affected by nature and selector backbones of the CSPs as well as the kind of amino acids. Baseline enantiomer separation and resolutions were observed for the enantiomers of all analytes as NBD derivatives especially on coated type amylose tris(3,5-dimethylphenylcarbamate) derived CSPs (Chiralpak AD-H and Lux Amylose-1). The other CSPs also showed good enantioselectivity except for the CSPs (Chiralpak IB, Chiralcel OD-H and Lux Cellulose-1) having cellulose tris(3,5-dimethylphenylcarbamate) as chiral selectors. The developed analytical chiral method was applied to determine the enantiomeric purity of seven commercially available L-α-amino acids and the impurities as D-forms were found to be in the range 0.08-0.87 %, respectively. The intra- and interday accuracy and precision assays showed high accuracy and precision of the developed analytical method. This chiral HPLC method for the enantiomer resolution of amino acids using fluorescent derivatization could be useful for the determination of enantiomeric purity of pharmaceuticals and biological study for amino acid type compounds among chiral drugs.

Quantitative analysis of capsaicinoids in Capsicum annuum using HPLC/UV

  • Gia Han Tran;Hyejin Cho;Chohee Kim;Ohyeol Kweon;Jun Yeon Park;Sullim Lee;Sanghyun Lee
    • Journal of Applied Biological Chemistry
    • /
    • v.66
    • /
    • pp.320-327
    • /
    • 2023
  • Capsicum annuum belongs to the Solanaceae family, crops of which are extensively cultivated worldwide. It is a food source containing various nutrients and vitamins and also serves as a medicine for treating ailments. The burning feeling experienced while consuming Capsicum fruits is due to the presence of capsaicinoids, particularly capsaicin and dihydrocapsaicin. This study aimed to assess the content of these two compounds in 34 varieties of capsicum and paprika. High-performance liquid chromatography with a gradient elution system and a reverse-phase YMC Pack-Pro column with UV detection at 280 nm was employed. The results revealed that, among the 34 samples, only six samples (samples 1, 15, 20, 29, 32, and 34) contained capsaicin and dihydrocapsaicin, and their highest contents were found in sample 1 - variety name: Sungil-c (capsaicin: 3.42 mg/g extract, dihydrocapsaicin: 1.20 mg/g extract). These findings suggest that the content of these two compounds is attributed to the variety and is influenced by geographical location and environmental factors. Additionally, this study provides a basis for establishing a C. annuum variety with high capsaicin and dihydrocapsaicin contents.

Oil Fluorescence Spectrum Analysis for the Design of Fluorimeter (형광 광도계 설계인자 도출을 위한 기름의 형광 스펙트럼 분석)

  • Oh, Sangwoo;Seo, Dongmin;Ann, Kiyoung;Kim, Jaewoo;Lee, Moonjin;Chun, Taebyung;Seo, Sungkyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.304-309
    • /
    • 2015
  • To evaluate the degree of contamination caused by oil spill accident in the sea, the in-situ sensors which are based on the scientific method are needed in the real site. The sensors which are based on the fluorescence detection theory can provide the useful data, such as the concentration of oil. However these kinds of sensors commonly are composed of the ultraviolet (UV) light source such as UV mercury lamp, the multiple excitation/emission filters and the optical sensor which is mainly photomultiplier tube (PMT) type. Therefore, the size of the total sensing platform is large not suitable to be handled in the oil spill field and also the total price of it is extremely expensive. To overcome these drawbacks, we designed the fluorimeter for the oil spill detection which has compact size and cost effectiveness. Before the detail design process, we conducted the experiments to measure the excitation and emission spectrum of oils using five different kinds of crude oils and three different kinds of processed oils. And the fluorescence spectrometer were used to analyze the excitation and emission spectrum of oil samples. We have compared the spectrum results and drawn the each common spectrum regions of excitation and emission. In the experiments, we can see that the average gap between maximum excitation and emission peak wavelengths is near 50 nm for the every case. In the experiment which were fixed by the excitation wavelength of 365 nm and 405 nm, we can find out that the intensity of emission was weaker than that of 280 nm and 325 nm. So, if the light sources having the wavelength of 365 nm or 405 nm are used in the design process of fluorimeter, the optical sensor needs to have the sensitivity which can cover the weak light intensity. Through the results which were derived by the experiment, we can define the important factors which can be useful to select the effective wavelengths of light source, photo detector and filters.

HPLC Analysis of Piroxicam in the Rabbit Plasma and its Bioavailability after the Transdermal Administration of Patches (토끼 혈장 중 피록시캄의 HPLC 분석 및 패취제 투여 후 경피흡수)

  • Shin, Dae-Hwan;Park, Seong-Hyeok;Lee, Gyeong-Bok;Lee, Chong-Kil;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.3
    • /
    • pp.177-183
    • /
    • 2009
  • A rapid and sensitive reversed-phase high performance liquid chromatography (HPLC) method was developed for the determination of piroxicam in the rabbit plasma. After a treatment of plasma sample by liquid-liquid extraction, the drug was analyzed on an HPLC system with ultraviolet detection at 330 nm. HPLC was carried out using reversed-phase isocratic elution with a C18 column, a mobile phase of a mixture of acetonitril, doubly deionized water and acetic acid 43.74:56.00:0.26 v/v%) at a flow rate of 1.1 mL/min. The chromatograms showed good resolution and sensitivity and no interference of plasma. The calibration curve for the drug in plasma sample was linear over the concentration range of 0.01-2.0 ${\mu}$g/mL. The intra- and inter-day assay accuracies of this method ranged from 86.82% to 108.33% of normal values and the precision did not exceed 13% of relative standard deviation. The plasma concentration of piroxicam decreased to below the quantifiable limit at 12 hr after the i.v. bolus administration to rabbits following dose of 0.375 mg/kg yielding a apparen t plasma half life of 1.38 hr. The transdermal route prolongs plasma levels of piroxicam. The bioavailability, calculated from the dose-adjusted ratio of the $AUC_{transdermal}$ to the $AUC_{i.v.}$, was 7.44%. The plasma concentration of piroxicam was detected by 48 hr after the transdermal administration of patch at a dose of 32 mg/kg. This method was suitable for cutaneous absorption studies of piroxicam in the rabbit after transdermal administration of different types of dosages of the drug.