3D 초음파 영상에서 방광 내 잔뇨량 추정을 위한 새로운 알고리즘 (A New Algorithm to Estimate Urine Volume from 3D Ultrasound Bladder Images)

  • 조태식;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권1호
    • /
    • pp.31-38
    • /
    • 2016
  • For the patients with bladder dysfunction, measurement of urine volume inside the bladder is very critical to avoid bladder failure. In measuring urine volume inside a bladder, low-resolution 3D ultrasound images are widely used. However, urine volume estimation from 3D ultrasound images is prone to big errors and inconsistency because of low spatial resolution and low signal-to-noise ratio of ultrasound images. We developed a new robust volume estimation algorithm which is not computationally expensive. We tested the algorithm on a lab-built ultrasound bladder phantom and volunteers. The average error rate of the human bladder volume estimation was 5.9% which was better than the commercial machine.

손 동작 스캔을 이용한 잔뇨량 측정용 초음파 방광 스캐너 (A New Ultrasound Bladder Scanner to Estimate Urine Volume Using Hand-Motion Scan)

  • 이정환;배정호;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권4호
    • /
    • pp.153-160
    • /
    • 2018
  • 3D ultrasound bladder scanners are getting popular in hospitals for the patients with bladder dysfunction. A current bladder scanner adopts a mechanical scan to acquire 3D images and requires two motors and complicated mechanical devices. In this paper, we propose a new ultrasound bladder scanner using hand-motion scan. Instead of two motors and mechanical devices, it has a motion sensor to record transducer positions during hand-motion scan. The experiments with a bladder phantom and volunteers showed similar measurement accuracy to a conventional 3D ultrasound bladder scanner. We expect that the proposed method will reduce the cost and size of the bladder scanner.

부피 측정을 위한 초음파 팬텀 개발 (Development of Ultrasound Phantom for Volume Calibration)

  • 김혜영;이지혜;이경자;서현숙;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.227-230
    • /
    • 2008
  • 본 연구에서는 2차원 초음파 시스템의 체적 측정 정확성을 측정하기 위한 초음파 팬텀을 설계 및 제작하였다. 팬텀은 체적 측정용 타겟과 백그라운드 물질로 구성되었다. 백그라운드 물질은 agarose gel과 물을 혼합하여 만들었다. 타켓은 모양과 부피를 변화시키기 위하여 신축성 있는 물질로 선택하였고 타겟에 물을 채운 후 백그라운드 물질에 삽입하였다. 2차원 초음파 시스템의 정확성을 평가하기 위하여 세가지 형태의 타겟(구형, 2가지 형태의 타원형, 삼각 기둥형)을 제작하였다. 타원형의 경우, 하나는 길이와 폭의 크기가 비슷하도록 제작하였고(타원 1) 다른 하나는 길이가 폭보다 2배 이상인 모양(타원 2)으로 제작하였다. 각각 형태의 타겟 부피는 94 cc에서 450 cc까지 변화하였고 2차원 초음파 장비(128XP, ACUSON)를 이용하여 정확성을 측정하였다. 구 모양의 타겟에 삽입된 물의 실제 체적과 측정된 체적 간의 차는 6.7에서 11% 이다. 타원형 타겟의 경우 타원 1은 9.2에서 10.5% 사이의 차이를 보이는데 타원 2의 경우는 25.7%의 오차가 있다. 삼각기둥 형태의 경우는 실제체적과 측정체적간 20.8에서 35%의 차이를 보였다. 쉽고 간편한 방법의 초음파 팬텀의 제작 방법을 소개하였고 제작된 팬텀을 이용할 경우 초음파 시스템의 부피 측정 정확성을 평가할 수 있음을 입증하였다.

  • PDF

CT 및 초음파 스캔 데이터를 이용한 체적 측정의 정확도 및 유용성 (Accuracy and Usefulness of Volume Measurement using CT and Ultrasound Scan Data)

  • 김현주;이후민;윤준
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.289-294
    • /
    • 2022
  • 본 연구는 CT와 USG 스캔 데이터를 이용하여 팬텀 실험과 환자 스캔 데이터를 활용하는 임상실험으로 체적 측정의 정확도 및 유용성을 알아보았다. 그 결과 CT와 USG 스캔 데이터 모두 다양한 체적의 실제 원형 팬텀의 체적과 유의한 차이가 없었으며(p>0.05), 동일 환자의 방광 체적 측정 결과 CT 데이터는 236.9±2.1, USG 영상은 236.9±1로 측정되어 통계분석 결과 유의한 차이가 없는 것으로 분석되었다(p>0.05). 본 결과의 임상 적용은 추가 임상실험이 필요하지만, 환자 피폭, 검사자의 스캔 기술, 그리고 CT 재구성 경험 등을 고려하여 CT 또는 초음파 장치를 선택 적용한다면 의료영상을 활용한 체적 측정의 유용성 측면에서 기초자료로 적용 가치가 있을 것으로 사료된다.

초음파 조영제를 애용한 Echo PIV 기법의 개발 (Development of Echo PIV Using Ultrasound Contrast Agent)

  • 김형범
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1528-1534
    • /
    • 2004
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) methods has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow result of echo PIV showed good agreement with both optical PIV measurements and the known analytic solution based on a volume flow measurement.

Comparison of real-time ultrasound imaging for manual lymphatic drainage on breast cancer-related lymphedema in individuals with breast cancer: a preliminary study

  • Seo, Dongkwon;Lee, Seungwon;Choi, Wonjae
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권1호
    • /
    • pp.43-48
    • /
    • 2020
  • Objective: Breast cancer-related lymphedema (BCRL) is a major sequela after surgery or radiotherarpy for breast cancer. Manual lymphatic drainage (MLD) is designed to reduce lymph swelling by facilitating lymphatic drainage. This study attempted to determine the histologic changes in the skin and subcutaneous layer, and the immediate effect of MLD in decreasing lymphedema using ultrasound imaging, which is the method used most commonly to eliminate BCRL. Design: A single-group experimental study. Methods: Five subjects who were diagnosed with hemiparetic upper extremity lymphedema more than six months after breast cancer surgery participated in the study. MLD was performed for 60 minutes in the order of the thorax, breast, axilla, and upper arm of the affected side. In order to determine the effect of MLD, ultrasound imaging and limb volume were assessed. Two measurement tools were used for asessing lymphedema thickness among the pretest, posttest, and 30-minute follow-up period. Results: Significant diferences in ultrasound imaging and upper limb volume were found between the affected side and non-affected side (p<0.05). On the affected side, although ultrasound imaging showed a significant decrease after MLD (p<0.05), there were no significant difference in upper limb volume when compared to the baseline. Conclusions: In this study, a significant decrease in lymphedema by MLD was demonstrated by ultrasound imaging, which is considered to be more useful in assessing histological changes than limb volume measurements. Further research on the protocol for eliminating lymphedema will be needed.

초음파를 이용한 Bladder형태에 따른 잔뇨량 측정의 정확도 연구 (A Study on the Accuracy of Measurement of Residual Urine Amount depending on the Bladder form using Ultrasonic)

  • 김연민;박태훈;김진혁;김수지;조다훈;허진영;한동균
    • 대한디지털의료영상학회논문지
    • /
    • 제16권2호
    • /
    • pp.1-7
    • /
    • 2014
  • This study is to increase the accuracy of the diagnosis of benign prostatic hyperplasia by presenting a method that can accurately measure the residual urine amount of the bladder by using an ultrasound image. Agar powder, Propanol and distilled water were used as materials for making a phantom. In order to measure the volume, a $10m{\ell}$ cylinder, syringe and beaker were used. The image was obtained by scanning phantoms produced into six shapes. Each constant value was obtained by using the expression designed to measure the residual urine amount of the bladder and was compared and analyzed. The measuring method of Bladder volume was presented and a constant value for each shape was obtained and five observers measured it five times. According to the results of clinical application, the errors of Ellipse-beanbag, Shield-shield were 11.0%, 18.2%, respectively. Constant values depending on the shape of each phantom were presented in order to accurately measure the volume of the bladder in measuring the amount of residual urine for the diagnosis of benign prostatic hyperplasia. The accuracy of the volume using this was verified statistically(p > 0.05). Therefore, it is considered to be useful in diagnosing benign prostatic hyperplasia by using the ultrasound imaging measuring method presented.

  • PDF

3차원 의료영상진단기기를 이용한 가상 전립선 용적 측정 (Measurement of Prostate Phantom Volume Using Three-Dimensional Medical Imaging Modalities)

  • 성열훈;주용현;최보영
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권4호
    • /
    • pp.285-291
    • /
    • 2010
  • Recently, advance on various modalities of diagnosing, prostate volume estimation became possible not only by the existing two-dimension medical images data but also by the three-dimensional medical images data. In this study, magnetic resonance image (MRI), computer tomography (CT) and ultrasound (US) were employed to evaluate prostate phantom volume measurements for estimation, comparison and analysis. For the prostate phantoms aimed at estimating the volume, total of 17 models were developed by using devils-tongue jelly and changing each of the 5ml of capacity from 20ml to 100ml. For the volume estimation through 2D US, the calculation of the diameter with C9-5Mhz transducer was conducted by ellipsoid formula. For the volume estimation through 3D US, the Qlab software (Philips Medical) was used to calculate the volume data estimated by 3D9-3Mhz transducer. Moreover, the images by 16 channels CT and 1.5 Tesla MRI were added by the method of continuous cross-section addition and each of imaginary prostate model's volume was yielded. In the statistical analysis for comparing the availability of volume estimation, the correlation coefficient (r) was more than 0.9 for all indicating that there were highly correlated, and there were not statistically significant difference between each of the correlation coefficient (p=0.001). Therefore, the estimation of prostate phantom volume using three-dimensional modalities of diagnosing was quite closed to the actual estimation.

초음파 뇨량검출 센서의 제작 및 방광 벽간거리와 뇨량과의 상관관계에 관한 연구 (A Study on the Development of Ultrasonic Urine Volume Detection Sensor and the Correlation between Urine Volume and Bladder Interwall Distance)

  • 최흥호;이응혁
    • 센서학회지
    • /
    • 제9권4호
    • /
    • pp.256-267
    • /
    • 2000
  • 본 논문에서는 뇨실금 환자들에 대한 지원 기술의 일환으로 인체에 무해하고 비침습적인 초음파를 이용하여 배뇨시기를 알려주는 뇨의 경보기용 뇨량검출 센서의 개발과 이를 이용한 방광 벽간거리와 뇨량과의 상관관계에 관하여 연구하였다. 개발된 센서의 중심 주파수는 2.25 MHz이며, 이는 인체내로의 침투력이 비교적 좋으면서도 분해능이 높아 오차를 감소시킬 수 있게 설계하였다. 이 센서를 이용하여 방광 전 후벽간의 거리를 검출하여 이로부터 뇨량을 정량적으로 측정하기 위한 기초 실험을 실시하였다. 기초실험은 건강한 성인 남자 3명을 대상으로 초음파 뇨량검출 센서를 이용한 초음파 RF 반사신호 획득장치와 초음파 진단기에 의한 2가지 방법으로 이루어졌고 그 결과 뇨량과 벽간거리와의 사이에는 높은 상관성이 있음을 확인할 수 있었다. 결론적으로, 실험 결과를 토대로 하여 제작된 초음파 뇨량검출용 센서는 뇨실금 환자로 하여금 배뇨시기를 알려주는 뇨의 경보 시스템으로 활용될 수 있으며, 보건 복지적인 측면에서 현대사회에 기여할 공헌도가 매우 클 것이라 생각된다.

  • PDF

Characteristics of deodorization for malodorants in aqueous solution by sonication

  • Yoo, Young-Eok;Maeda, Yasuaki
    • 한국환경과학회지
    • /
    • 제13권2호
    • /
    • pp.167-173
    • /
    • 2004
  • A aqueous solution of malodorants (i.e., n-valeraldehyde, n-valeric- acid, 2-methylisoborneol, and trimethylamine) was exposed to 200KHz ultrasound with a power of 6.0W/$\textrm{cm}^2$ per unit volume in a sonochemical reactor under room temperature and atmospheric pressure condition. The concentration of malodorants decreased with irradiation time, indicating pseudo-first-order kinetics. The removal efficiency of malodorants was about from 50% to 96% decomposed after 90 minutes sonication. At the deodorization, it was determined by triangle odor bag(TOB) method for odor sensory measurement, and it indicated that over 60% of relative odors were deodorized with degradation by the sonication.