• 제목/요약/키워드: Ultrasound sonography

검색결과 57건 처리시간 0.025초

Can Ultrasound be Used to Differentiate Tubular Adenomas of Breast from Fibroadenomas or Carcinoma?

  • Fu, Ying;Miao, Li-Ying;Ge, Hui-Yu;Mei, Fang;Wang, Jin-Rui
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권3호
    • /
    • pp.1269-1274
    • /
    • 2014
  • Breast tubular adenomas are rare benign breast tumors and detailed descriptions of their sonographic appearance are necessary for differential diagnosis from fibroadenomas or breast cancers. This study investigated twenty-one histology-proved tubular adenomas in 17 patients and also included 48 fibroadenomas in 35 patients as a control group. There was no significant difference between the two groups with clinical presentation, which was age, tumor location, tumor number (p>0.05). Statistic analysis showed three significant factors in the differential diagnosis of tubular adenomas and fibroadenomas, including macro-lobulation (p=0.01), "tiny branch like" patterns (p=0.001) and vascularity (p=0.02). Other ultrasonographic features such as echogenicity, border, uniformity of echotexture, posterior acoustic enhancement, lateral wall shadowing were of no clinical significance (p>0.05). Calcifications were seen in three tubular adenomas which were different from those of carcinomas. Although tubular adenomas have some typical characteristics on sonography, surgery and core needle biopsy are still needed for complex cases to exclude progress to malignancy.

복부초음파를 이용한 상완혈(上脘穴)-췌장 수직거리 측정시스템의 재현성 반복성 평가실험-A Pilot Study- (Gage R&R Study on Abdominal Sonography for Measuring Distance from Sangwan (CV13) to Pancreas - A Pilot Study -)

  • 남동현
    • 대한한의진단학회지
    • /
    • 제14권2호
    • /
    • pp.75-84
    • /
    • 2010
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from Sangwan (CV13) to pancreas. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from CV13 to pancreas with a ultrasound device three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from CV13 to pancreas was 6.29. So we concluded that repeatability and reproducibility of the ultrasound device system for measuring distance from CV13 to pancreas was acceptable.

족저근막염의 초음파유도하 봉약침 치험1례 (A Case Report of Ultrasound-guided Bee Venom Pharmacopuncture on Plantar Fasciitis)

  • 오승윤;염지윤;박수정
    • 대한한의학회지
    • /
    • 제44권1호
    • /
    • pp.108-116
    • /
    • 2023
  • Objectives: This study is to report the usefulness of ultrasound in diagnosing plantar fasciitis and the effectiveness of ultrasound-guided bee venom pharmacopuncture as a treatment of it. Methods: A 61-year-old woman suffered from plantar fasciitis on her right foot for 1 month. The sonographic findings were fascial thickening, blurring of perifascial border and perifascial effusion. The ultrasound-guided bee venom pharmacopuncture for 6 times and conventional Korean medicine therapies like acupuncture and moxibustion for 12 times in 5 weeks. Numeric rating scale (NRS) and foot function index(FFI) was used to evaluate the pain and its progress. and thickness of plantar fascia was measured by sonography every week. Results: After treatments, NRS and FFI were reduced from 10 to 1 and from 190 to 72. The thickness of fascia was reduced from 0.43cm to 0.40. Blurring and effusion of perifascial border were also improved. Conclusion: This report suggests that the Ultrasound-guided Bee Venom Pharmacopuncture is effective for Plantar Fasciitis. Ultrasonography could be one of the most valuable items in the clinical practice of Korean medicine doctors who seek minimally invasive treatment.

신체활동과 골초음파지표와의 연관성 (Association Between Physical Activity and Quantitative Ultrasound in a Rural Population)

  • 김승준;신민호;권순석
    • 한국전문물리치료학회지
    • /
    • 제12권2호
    • /
    • pp.20-27
    • /
    • 2005
  • Osteoporosis is characterized by low bone mass and the microarchitectural deterioration of bone tissue with a consequent increase in bone fragility and susceptibility to fracture. It has been suggested that speed of sound (SOS) and broadband ultrasound attenuation (BUA) of quantitative ultrasound sonography (QUS) may provide information about not only bone density but also the microarchitecture and elastic properties of bone. Physical inactivity reduced mechanical usage and it made process to the bone changes. This study aimed to association between the physical activity and the QUS parameters in 1305 (593 men, 712 women) aged 20 years over in a rural population. Two QUS parameters, BUA (p=.23) and SOS(p=.73) were measured at the right calcaneus of postmenopausal women, no significant associations were observed between sports index and SOS and BUA. These results suggest that work, non-sports leisure physical activity (p<.01) have a significant influence on QUS parameters in a rural population. Physical activity are meaningful predictor of QUS parameters of the calcaneus in a rural population.

  • PDF

BreastLight Apparatus Performance in Detection of Breast Masses Depends on Mass Size

  • Shiryazdi, Seyed Mostafa;Kargar, Saeed;Taheri-Nasaj, Hossein;Neamatzadeh, Hossein
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권3호
    • /
    • pp.1181-1184
    • /
    • 2015
  • Background: Accurate measurement of breast mass size is fundamental for treatment planning. We evaluated performance of BreastLight apparatus in detection breast of masses with this in mind. Materials and Methods: From July 2011 to September 2013, a total of 500 women referred to mammography unit in Yazd, Iran for screening were recruited to this study. Performance of BreastLight in detection breast masses regard their sizeing, measured with clinical breast examination (CBE), mammography and sonography, was assessed. Sonographic and mammography examinations were performed according to breast density among women in two groups of women younger (n=105) and older (n=395) than 30 years. Size correlations were performed using Spearman rho analysis. Differences between mass size as assessed with the different methods (mammography, sonography, and clinical examination) and the BreastLight detection were analyzed using $X^2$-trend test. Results: Performance of the BreastLight in detection of lesions smaller than or equal to 1 cm assessed by CBE, mammography and sonography was 4.4%,7.7% and 12.5% and for masses larger than 4 cm was 65%, 100% and 57.1%, respectively. The performance of BreastLight in detection was significantly increased with larger masses (p<0.001). Conclusions: We conclude that clinical measurement of breast cancer size is as accurate as that from mammography or ultrasound. Accuracy can be improved by the use of a simple formula of both clinical and mammographic measurements.

하악골 신장술의 초음파적 변화 (SONOGRAPHIC CHANGE OF MANDIBULAR DISTRACTION OSTEOGENESIS)

  • 김철환
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권4호
    • /
    • pp.297-306
    • /
    • 2007
  • Distraction osteogenesis was pioneered by Ilizarov in the treatment of injured extremities. Its subsequent application to Oral and Maxillofacial Surgery has opened a new chapter in the treatment of facial deformity. Careful monitoring of the period of distraction and consolidation of the callus is important and has been well described. Complications, such as infection, haematoma and premature ossification, are difficult to diagnose and can compromise the outcome after the surgery. Too slow rate of distraction results in premature fusion of cortices and too rapid information of bone 'cyst' within the callus distraction. I experienced 2 patients of congenital unilateral mandibular hypoplasia, so called Hemifacial Microsomia. After distraction surgery, I evaluated callus formation of mandibular distraction with Ultrasound Sonography during distraction and consolidation period. Plain radiography, although it enables accurate measurement of the distraction gap, did not give sufficient detail to allow assessment of early stages of bone formation, But, ultrasound monitoring could enable continuous monitoring of the distraction gap without exposure to ionizing radiation and allow detection of fine detail, which may influence manipulation of the callus.

초음파를 활용한 회전근개 간격으로 접근한 견관절 주사법 (Ultrasound Guided Shoulder Joint Injection through Rotator Cuff Interval)

  • 임종범;김영기;김성우;성규완;정일;이청
    • The Korean Journal of Pain
    • /
    • 제21권1호
    • /
    • pp.57-61
    • /
    • 2008
  • Background: Shoulder joint injection is currently performed under fluoroscopic or computed tomography scan guidance. We performed this study to determine if an ultrasound guided shoulder joint injection through rotator cuff interval would have clinical usefulness. Methods: A total of 17 volunteers [12 women, 5 men; mean age 28 yr (23-32 yr)] received shoulder joint injection under multilinear ultrasound (5-10 MHz). Volunteers were positioned supinely on a table with their arm in a neutral position. The anterior shoulder region of the patient was sterilized using povidone iodine. A 24 gauge needle was introduced and directly visualized in real time as it passed obliquely from the skin surface to the inferior space of the biceps tendon. If there was little or no resistance to the injection, a contrast media (omnipaque) was injected and checked fluoroscopically. Results: Ultrasound guided shoulder joint injection through rotator cuff interval was successful in all cases. The average time taken for the procedure was $27.5{\pm}16.5sec$. The vertical distance from skin to the inferior space of the biceps tendon was $1.6{\pm}0.4cm$ and the distance of needle from the skin to the inferior space of biceps tendon was $2.8{\pm}0.6cm$. The procedure was well tolerated by all volunteers. Conclusions: Ultrasound guided shoulder joint injection through rotator cuff interval is an effective, rapid, and easy-to-perform injection technique. Ultrasound guided injection enables exact needle placement and avoids the use of both ionizing radiation and iodinated contrast material.

방사선사의 초음파검사 시 체감하는 직무만족도의 구조적 관계 해석 (Analysis of Structural Relationship of Job Satisfaction Levels Felt in Ultrasound Examination by Radiological Technologists)

  • 김혜진;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권4호
    • /
    • pp.325-336
    • /
    • 2023
  • The purpose of this study was to analyze the structural relationship between job satisfaction levels felt during ultrasound examination of radiological technologists (RTs) using a structural equation model. The subjects were a total of 203 RTs currently working in medical institutions. The method was conducted as a survey study using a questionnaire consisting of a total of 29 questions consisting of demographic characteristics and job satisfaction levels that were self-efficacy, job competency, extrinsic compensation, and job satisfaction. The reliability was secured with the Cronbach's alpha coefficient of 0.6 or higher. For statistical analysis, a significant difference between the frequency analysis of demographic characteristics and the mean of the job satisfaction levels were performed by independent sample T-test and one-way analysis of variance (ANOVA) followed by Scheffe's post hoc test. The correlation analysis between variables was tested with Spearman's and Pearson's correlation coefficient. We analyzed the structural relationships between variables by structural equations. As a result, first, job competency and extrinsic compensation had a positive effect on job satisfaction on ultrasound examination of RTs. Second, the self-efficacy of ultrasound examination RTs showed a high correlation with job competency. Third, the job satisfaction levels showed in the order of job competency, job satisfaction, self-efficacy, and extrinsic compensation. In conclusion, this study are expected to be provided as data to identify factors that could improve job satisfaction during ultrasound examination of RTs by empirically analyzing the structural relationship of self-efficacy, job competency, and external compensation.

이중 초음파 검사를 이용한 미숙아의 전 뇌동맥 혈류 측정 (The Measurement of Blood Flow of Anterior Cerebral Artery in Premature Newborns Using Duplex Doppler Ultrasonography)

  • 황미수;배경국;이재교
    • Journal of Yeungnam Medical Science
    • /
    • 제14권1호
    • /
    • pp.77-84
    • /
    • 1997
  • 55명의 미숙아를 대상으로 이중 도플러 초음파 검사를 실시하여 대천문을 통한 전 뇌동맥의 혈류속도 및 혈류형태를 조사하였다. 미숙아에서 뇌 혈류속도 및 pulsatility index는 재태기간, 출생 체중, 및 미숙아의 나이 등의 증가에 따라 비례하여 증가하였으나 resistive index는 감소하였다. 뇌실 출혈이 있는 환아 군에서는 특징적인 resistive index의 증가가 보였지만 혈류속도 및 plusatility index는 불규칙하였다. 정상 미숙아의 뇌혈류 관찰 및 환아 군에서의 뇌혈류 검사에서 이중 도플러 초음파 검사는 비침습적이고 재현성도 뛰어나 선별검사로 유용한 방법이라고 생각한다.

  • PDF

추나요법을 포함한 한의학적 치료로 호전된 드퀘르벵 건초염 2예: 초음파 전후 관찰 비교 (Korean Medicine Treatment Including Chuna Manual Therapy on De Quervain's tenosynovitis Two Cases Reports: Comparision by Ultrasound)

  • 배준형;이성준;변상현;안해인;김남권
    • 한방재활의학과학회지
    • /
    • 제31권4호
    • /
    • pp.211-219
    • /
    • 2021
  • This study reports the effectiveness of Korean medicine and Chuna manual therapy on patients with De Quervain's tenosynovitis. Two patients were treated with Chuna manual therapy, electro-acupuncture, moxibustion therapy. We used numeric rating scale (NRS), Finkelstein's test, sonography to measure changes during treatment. After each treatment, NRS, Finkelstein's test, sonography outcome were improved. Korean medicine including Chuna manual therapy can be effectively used to improve De Quervain's tenosynovitis. This study may suggest that korean medicine including Chuna manual therapy can be effective for De Quervain's tenosynovitis.