• Title/Summary/Keyword: Ultrasound signal

Search Result 195, Processing Time 0.026 seconds

Removal Method of Signal Interference between Ultrasound Sensors (초음파 센서 간 신호 간섭 제거 방법)

  • Im, Hyungchul;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.584-590
    • /
    • 2021
  • This paper proposes a removal method of signal interference between ultrasound sensors where ghost signals due to interference are excluded and correct signal is recognized in distance mensurement using ultrasound sensors. The proposed method detects and excludes ghost signals when previous measured distance is compared to current measured distance and the distance difference exceeds a threshold. The threshold is fixed in conventional methods, so ghost signals cannot be correctly excluded when ultrasound sensor or target object move rapidly. On the contrary, to improve accuracy, the threshold is not fixed in the proposed method, and the threshold is adpatively determined based on the relative velocity when ultrasound sensor or target object move. Experiments of distance measurement with ultrasound signal interference are carried out where multiple ultrasound sensors of same type are exploited with maximum interference, and the results show that the proposed method efficiently exclude ghost signals.

Distance Estimation Using Discretized Frequency Synthesis of Ultrasound Signals (초음파의 이산 주파수 합성을 이용한 거리 측정)

  • Park, Sang-Wook;Kim, Dae-Eun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.5
    • /
    • pp.499-504
    • /
    • 2011
  • In this paper, we suggest a method for discretized frequency modulations of ultrasonic signals. A continuous sweep of frequency modulation signals can be modelled with fine levels of discretization. If the ultrasound signals are modulated with monotonically decreasing frequencies, then the cross-correlation between an emitted signal and received signal can be used to identify the distance of multiple target objects. For the discretized frequency synthesis, CF ultrasounds with different frequencies are serially ordered. The auto-correlation test with the signal shows effective results for distance estimation. The discretized frequency syntheses have better distance resolution than CF ultrasound signals and the resolution depends on the number of the combined ultrasound frequencies.

Implementation of low-noise, wideband ultrasound receiver for high-frequency ultrasound imaging (고주파수 초음파 영상을 위한 저잡음·광대역 수신 시스템 구현)

  • Moon, Ju-Young;Lee, Junsu;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.4
    • /
    • pp.238-246
    • /
    • 2017
  • High frequency ultrasound imaging typically suffers from low sensitivity due to the small aperture of high frequency transducers and shallow imaging depth due to the frequency-dependent attenuation of ultrasound. These limitations should be overcome to obtain high-frequency, high- resolution ultrasound images. One practical solution to the problems is a high-performance signal receiver capable of detecting a very small signal and amplifying the signal with minimal electronic noise addition. This paper reports a recently developed low-noise, wideband ultrasound receiver for high-frequency, high-resolution ultrasound imaging. The developed receiver has an amplification gain of up to 73 dB and a variable amplification gain range of 48 dB over an operating frequency of 80 MHz. Also, it has an amplification gain flatness of ${\pm}1dB$. Due to these high performances, the developed receiver has a signal-to-noise ratio of at least 8.4 dB and a contrast-to-noise ratio of at least 3.7 dB higher than commercial receivers.

A Study of the Development for Fatty Liver Quantification Diagnostic Technology from Ultrasound Images using a Simulated Fatty Liver Phantom (모사 지방간 팬텀을 활용한 초음파영상에서 지방간 정량화 진단 기술 개발을 위한 연구)

  • Yei-Ji Lim;Seung-Man Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.135-144
    • /
    • 2024
  • Ultrasonography examination has limitations in quantifying hepatic fat quantification. Therefore, this study aimed to experimentally demonstrate whether changes in signal attenuation during ultrasound imaging can be quantified using simulated hepatic phantoms to assess hepatic fat content. Additionally, we aimed to evaluate the potential of ultrasound imaging for diagnosing hepatic fatty liver by analyzing the relationship between hepatic fat content and signal intensity in ultrasound images. In this study, we developed a total of five stimulated hepatic phantoms by homogeneously mixing water and oil. We confirmed the fat content of the phantoms using magnetic resonance imaging (MRI) and ultrasound imaging, and measured signal intensity according to distance in ultrasound images to analyze the correlation and mean comparison between fat content and signal intensity. We observed that as the fat content increased, the ultrasound penetration intensity decreased, confirming the potential for quantifying hepatic fat content using ultrasound. Additionally, the analysis of the correlation between the measured fat content using MRI and the signal intensity measured in ultrasound images showed a high correlation. Statistical analysis in our study confirmed that as the fat content increased, the slope representing signal during ultrasound imaging (US-GRE) decreased. In this study, it was statistically confirmed that the US-GRE value of ultrasound images gradually decreases as the fat content increases, and it is believed that US-GRE can serve as a biomarker expressing fatty liver content.

Advanced Indoor Zone Detection with Bluetooth and Ultrasound of Smartphone (스마트폰의 블루투스와 초음파를 이용한 향상된 실내 영역 결정)

  • Kwon, Jin-Se;Lee, Je-Min;Kim, Hyung-Shin
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.11 no.3
    • /
    • pp.135-141
    • /
    • 2016
  • Indoor zone-based services have continuously become popular by increased prevalence of smartphones. Bluetooth and ultrasound can be used for zone detection. However, bluetooth does not guarantee precise zone detection if the signal degrades due to the obstacles. Ultrasound can be easily forged by recording sound on the smartphone. For that reason, zone detection based on ultrasound has a security hole. To remedy each limitation, we propose an advanced zone detection method, that combines bluetooth and ultrasound. An authentication server issues a one-time password to the user over bluetooth. The user generates an ultrasound signal that encodes the password. In this manner, the proposed method ensures secure and accurate zone detection.

Signal Processing in Medical Ultrasound B-mode Imaging (의료용 초음파 B-모드 영상을 위한 신호처리)

  • Song, Tai-Kyong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.521-537
    • /
    • 2000
  • Ultrasonic imaging is the most widely used modality among modern imaging device for medical diagnosis and the system performance has been improved dramatically since early 90's due to the rapid advances in DSP performance and VLSI technology that made it possible to employ more sophisticated algorithms. This paper describes "main stream" digital signal processing functions along with the associated implementation considerations in modern medical ultrasound imaging systems. Topics covered include signal processing methods for resolution improvement, ultrasound imaging system architectures, roles and necessity of the applications of DSP and VLSI technology in the development of the medical ultrasound imaging systems, and array signal processing techniques for ultrasound focusing.

  • PDF

Automatic optimization for time gain compensation and dynamic range control in ultrasound diagnostic systems (초음파 진단 기기에서의 시간 이득 보상과 다이나믹 범위 조절을 위한 자동 최적화 알고리즘)

  • Lee, Duhg-Oon;Kim, Yong-Sun;Ra, Jong-Beom
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.399-402
    • /
    • 2005
  • For efficient and accurate diagnosis of ultrasound images, the time gain compensation (TGC) and dynamic range (DR) control of the ultrasound echo signal are important. TGC is for compensating the attenuation of the ultrasound echo signal along the depth, and DR is used to control the image contrast. In this paper, we propose an algorithm for finding the optimized values of TGC and DR automatically. For TGC, the degree of compensation is determined along the depth based on the effective attenuation estimation of ultrasound signal. For DR optimization, we introduce a novel cost function on the basis of the characteristics of ultrasound image, which provides the minimum value at the optimal DR. Experiments have been performed by applying the proposed algorithm to a real US imaging system. The results show that the algorithm automatically can determine the values of TGC and DR in realtime so that the subjective quality of the corresponding US image may be good enough for diagnosis.

  • PDF

Development of Self-compensated Technique for Evaluation of Surface-breaking Crack by Using Laser Based Ultrasound

  • Choi, Sang-Woo;Lee, Joon-Hyun;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.3
    • /
    • pp.215-221
    • /
    • 2005
  • It is required to evaluate nondestructively depth of surface-breaking cracks in structures. In this paper, the self-compensated technique by laser-based ultrasound is used to measure the depth of surface-breaking defect. Optical generation of ultrasound produces a well defined pulse with reliable frequency content. It is broad banded and suitable for measurement of attenuation and scattering over a wide frequency range. The self-calibrated signal transmission data of surface wave shows good sensitivity as a practical tool far assessment of surface-breaking defect depth. It is suggested that the relationship between the signal transmission and crack depth can be used to predict the surface-breaking crack depths in structures.

Resolution Improvement of Ultrasound Signal Using Kalman Filter (칼만 필터를 이용한 초음파 신호의 해상력 향상)

  • Woo, Kwang-B.;Nam, Sang-E.;Shin, Dong-H.;Chin, Young-M.;Lee, Sung-M.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1985 no.06
    • /
    • pp.15-19
    • /
    • 1985
  • This study deals with a kind of signal processing, Kalman filtering techniques, which are applied to ultrasound signal to improve resolution capability. The main advantage of Kalman filter algorithm for the analysis of reflected ultrasound signal is its recursive structure which can be easily adapted to time-varing system. In state-space description of the system, the 6th order system produces the best spectral approximation to the source pulse. As a result of spectrum analysis, 6th order estimator for two closely spaced (0.5mm) reflectors enhance resolution by 4dB - 10dB. By using this result, the possibility to detect even minute tumor is found.

  • PDF

The Influence of the Pattern of Gripping the Ultrasound Head on the Activity of Upper Limb Muscles (초음파 도자를 쥐는 방법이 팔 근육의 근활성도에 미치는 영향)

  • Choi, Seok-Ho;Yi, Chung-Hwi;Jeon, Hye-Sun;Lee, Jeong-Weon
    • Physical Therapy Korea
    • /
    • v.20 no.2
    • /
    • pp.28-37
    • /
    • 2013
  • This study examined differences in the activity of upper limb muscles according to how an ultrasound head is gripped. Twenty-two adult males were participated in the study. Each participant was asked to apply ultrasound treatment on to a lump of pork meat by two different ultrasound head grip patterns: spherical and cylindrical grips. Muscle activity was measured in the extensor carpi radialis longus (ECRL), flexor carpi ulnaris (FCU), and pronator teres (PT), triceps brachii (TB), middle deltoid (MD), and upper trapezius (UT) muscles. There were no significant differences in the EMG signals of any muscle according to the ultrasound head grip pattern (p>.05). There were significant differences in the EMG signal of each type of muscle (p<.05). The EMG signal of UT was the lowest and that of TB was lower than ECRL and FCU. There were interactions between ECRL and FCU, between ECRL and PT, between FCU and ECRL, and between FCU and MD. The EMG signal of ECRL using the cylindrical head was low and that of FCU with the cylindrical head was high, while the opposite was the case with the spherical head ($p_{adj}$ <.05/15). The results of this study indicate that the wrist muscles worked actively when the participants applied ultrasound therapy using both spherical and cylindrical heads. A spherical head might induce imbalanced muscle activity among the wrist muscles, leading to deviation of the wrist joint. Therefore, the cylindrical head is recommended for ultrasound therapy because it produced a constant, repeated force.