• Title/Summary/Keyword: Ultrasound sensing method

Search Result 10, Processing Time 0.025 seconds

NO Sensing Characteristics of ZnO Nanorod Prepared by Ultrasound Radiation Method (초음파 처리에 의해 합성된 ZnO 나노로드 센서의 일산화질소 가스에 대한 감응 특성)

  • Park, Sun-Min;Zhang, Shao-Lin;Huh, Jeung-Soo
    • Korean Journal of Materials Research
    • /
    • v.18 no.7
    • /
    • pp.367-372
    • /
    • 2008
  • ZnO nanorod gas sensors were prepared by an ultrasound radiation method and their gas sensing properties were investigated for NO gas. For this procedure, 0.01, 0.005 and 0.001M of zinc nitrate hydrate [$Zn(NO_3)_2\;{\cdot}\;6H_2O$] and hexamethyleneteramine [$C_6H_{12}N_4$] aqueous solutions were prepared and then the solution was irradiated with high intensity ultrasound for 1 h. The lengths of ZnO nanorods ranged from 200 nm to 500 nm with diameters ranging from 40 nm to 80 nm. The size of the ZnO nanorods could be controlled by the concentration of solution. The sensing characteristics of these nanostructures were investigated for three kinds of sensor. The properties of the sensors were influenced by the morphology of the nanorods.

An Implementation of Mobile Respiration Detection Diagnostic System Using Ultrasound Sensing Method (초음파 센싱 방식의 이동형 호흡 측정 진단 시스템의 구현)

  • 김동학;김영길;정승호
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.514-517
    • /
    • 2003
  • Oxygen supply is one of the most basic things in human body. Breathing is controlled by the lungs' stationary function and the respiratory center which is in the mesulla oblongata. Nothing but, the external breathing that air movement between the lungs and atmosphere and the internal breathing that cellular air movement between the hemoglobin and a single cell. The adult's number of times of the respirations is about 15∼20 per 1 minute, but it depends ages, exercise, temperature, disease, etc. The important thing in detecting the respiration is that doing it in object person's resting time. Detecting the respiration have to be done without attracting any attention of object person. In present using method is detecting the pulse with catching an object person's wrist and observing the object person's movement. In this paper, we propose the mobile respiration detection diagnostic system using ultrasound sensing method that does not be influenced by the inertia error and the pressure error.

  • PDF

Sensitivity Elevation about Spirometer Using Ultrasound Sensing Method (초음파 센싱 방식의 spirometer에 대한 sensitivity 향상)

  • 한승헌;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.269-272
    • /
    • 2004
  • The respiration measurement method using the ultrasound sensor hardly gets an influence of an error of inertia and pressure and it is a respiratory detection device available semi-permanently. This device measures the amount and flow of respiration through using a delivery speed difference of the ultrasound waves that are a return format by the pneumatic stream that is a flogging of ultrasound waves during transmission and receipt as having used a characteristic of ultrasound waves. In this paper, it improved sensitivity of a signal to happen during transmission and receipt of a sensor because measurement must be performed with a patient to the center and measurement was played in a weak breathing so that it was possible.

  • PDF

A Study on the Sensitivity Elevation about Spirometer Using Ultrasound Sensing Method (초음파 센싱 방식의 spirometer에 대한 sensitivity 향상 연구)

  • Han, Seung-Heon;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.1
    • /
    • pp.204-209
    • /
    • 2005
  • The respiration measurement method using the ultrasound sensor hardly gets an influence of an error of inertia and pressure and it is a respiratory detection device available semi-permanently. This device measures the amount and flow of respiration through using a delivery speed difference of the ultrasound waves that are a return format by the pneumatic stream that is a flogging of ultrasound waves during transmission and receipt as having used a characteristic of ultrasound waves. In this paper, it improved sensitivity of a signal to happen during transmission and receipt of a sensor because measurement must be performed with a patient to the center and measurement was played in a weak breathing so that it was possible.

Indoor Localization of a Mobile Robot Using External Sensor (외부 센서를 이용한 이동 로봇 실내 위치 추정)

  • Ko, Nak-Yong;Kim, Tae-Gyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.5
    • /
    • pp.420-427
    • /
    • 2010
  • This paper describes a localization method based on Monte Carlo Localization approach for a mobile robot. The method uses range data which are measured from ultrasound transmitting beacons whose locations are given a priori. The ultrasound receiver on-board a robot detects the range from the beacons. The method requires several beacons, theoretically over three. The method proposes a sensor model for the range sensing based on statistical analysis of the sensor output. The experiment uses commercialized beacons and detector which are used for trilateration localization. The performance of the proposed method is verified through real implementation. Especially, it is shown that the performance of the localization degrades as the sensor update rate decreases compared with the MCL algorithm update rate. Though the method requires exact location of the beacons, it doesn't require geometrical map information of the environment. Also, it is applicable to estimation of the location of both the beacons and robot simultaneously.

Estimation of Ultrasonic Attenuation Coefficients in the Frequency Domain using Compressed Sensing (압축 센싱을 이용한 주파수 영역의 초음파 감쇠 지수 예측)

  • Shim, Jaeyoon;Kim, Hyungsuk
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.167-173
    • /
    • 2016
  • Compressed Sensing(CS) is the theory that can recover signals which are sampled below the Nyquist sampling rate to original analog signals. In this paper, we propose the estimation algorithm of ultrasonic attenuation coefficients in the frequency domain using CS. While most estimation algorithms transform the time-domain signals into the frequency-domain using the Fourier transform, the proposed method directly utilize the spectral information in the recovery process by the basis matrix without the completely recovered signals in the time domain. We apply three transform bases for sparsifying and estimate the attenuation coefficients using the Centroid Downshift method with Dual-reference diffraction compensation technique. The estimation accuracy and execution time are compared for each basis matrix. Computer simulation results show that the DCT basis matrix exhibits less than 0.35% estimation error for the compressive ratio of 50% and about 6% average error for the compressive ratio of 70%. The proposed method which directly extracts frequency information from the CS signals can be extended to estimating for other ultrasonic parameters in the Quantitative Ultrasound (QUS) Analysis.

Preliminary study of time-of-flight measurement for 3D position sensing system based on acoustic signals

  • Kim, Heung-Gi;Park, Youngjin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.79.4-79
    • /
    • 2002
  • Our goal is the development of a system that estimates the location of interested point in a room with accuracy and low cost. Non-contacting position estimating method is widely used in various areas. Among these methods, acoustic signal-based method is the cheapest and provides reasonably accurate estimation as a result of many research efforts. Most of the acoustic-signal-based three-dimensional location estimators such as 3D sonic digitizer are using the ultrasound, and are organized with two procedures; time-of-flight (TOF) estimation and localization estimation. Since the errors in estimating the TOF could be accumulated with that of localization estimate, accuracy of TOF estimate is as...

  • PDF

Design and Implementation of Mobile ]Respiration Detection Diagnostic System using Ultrasound Sensing Method fficient Multicasting Environment (초음파 센싱 방식을 이용한 이동형 호흡량 측정 진단기의 설계 및 구현)

  • 김동학;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.509-515
    • /
    • 2004
  • Pulmonary function tests are widely used to diagnose and determine patients' therapy in clinic. And it was also applied in the research of the physiology and dynamics for lung disease. Among the pulmonary function tests, spirometry is the most easy and economic test. Spirometers are medical instruments that measure the instantaneous rate of volume flow of respired Bas. The mechanical spirometer was mostly used in the past. Up to the present, the most popular method of spirometer is the differential pressure technique with which change in the volume of flow are transferred to change in pressure. This kind of instrument suffers from several limitations, pressure drop, difficulty in maintenance and short period of calibration. Therefore, this study has begun to implement ultrasound spirometer, which is free of pressure loss and has wide range, focusing on the flow measurement technique and diagnostic algorithm.

Location Tracking System for Container Trailer Using Ubiquitous Sensor Networks (USN를 이용한 컨테이너 트레일러 위치추적 시스템)

  • Park, Jong-Hyun;Choo, Young-Yeol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.3
    • /
    • pp.627-633
    • /
    • 2007
  • This paper describes position tracking system of a container trailer approaching to a gantry crane for loading or unloading a container into or from a ship, respectively. Proposed position tracking system informs the trailer driver of right position to stop the car under a gantry crane. To measure the location of a trailer, we used Cricket Mote modules which adopted RF and ultrasound technology. We present an elaborate method to improve position errors occurring at sensing and calculate three dimensional position by triangulation along with how to reduce location tracking interval for real-time monitoring. The location information was transmitted to a Personal Digital Assistant (PDA) periodically through Bluetooth communication for guidance of the trailer driver. In indoor and outdoor tests, position errors were less than 3 cm and location tracking interval was 0.5 second on average.

Development of Fine Dust Measurement Method based on Ultrasonic Scattering (초음파 산란 기법을 적용한 미세먼지 측정법 개발)

  • Choi, Hajin;Woo, Ukyong;Hong, Jinyoung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.40-48
    • /
    • 2019
  • New concept of fine dust measurement method is suggested based on ultrasonic scattering. These days, fine dust has been social problem in Korea, and many researches has been conducted including the area structural maintenance. Conventional measurement system such as optical scattering and semiconductor has a limit from environmental factors like relative humidity. However, ultrasound is based on mechanical waves, which perturb mechanical properties of medium such as density and elastic constants. Using the advantage, the algorithm for fine dust measurement is derived and evaluated using 2-D finite difference method. The numerical analysis simulates ultrasonic wave propagation inside multiple scattering medium like fine dust in air. Signal processing scheme is also suggested and the results show that the error of the algorithm is around minimum of 0.7 and maximum of 24.9 in the number density unit. It is shown that cross-section of fine dust is a key parameter to improve the accuracy of algorithm.