• Title/Summary/Keyword: Ultrasound measure

Search Result 152, Processing Time 0.026 seconds

Changes of abdominal muscle thickness during stable and unstable surface bridging exercise in young people

  • Kim, Tae Hoon;Hahn, Joohee;Jeong, Ju-Ri;Lee, Changjoo;Kim, You Jin;Choi, Sung Min;Jeon, Da Young;Lee, Jin Hwa;Lim, In-Hyuk;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.4
    • /
    • pp.210-214
    • /
    • 2016
  • Objective: The aim of this study was to measure the muscle architectural parameters of abdominal muscles in healthy individuals by rehabilitative ultrasound imaging (RUSI) and to investigate their changes after bridging exercise in various environments. Design: Cross-sectional study. Methods: The study included 40 healthy participants (19 men, 21 women). Subjects were randomly allocated to a stable surface group (SG, n=20) or an unstable surface group (UG, n=20). The participants assumed three positions in rest, bridging exercise with knee flexion $60^{\circ}$, and bridging exercise with knee flexion $90^{\circ}$ for the measurement of abdominal muscle thickness by RUSI. For the resting position, the participants held the head neutral in a hook-lying position and the dominant side was measured. For contraction, the participants performed the bridging exercise with the knee joint in $60^{\circ}$ and $90^{\circ}$ of flexion for 10 seconds each. Results: For transversus abdominis, external oblique muscle thickness, within the stable surface group and the unstable surface group, no significant contraction difference was observed in both the $60^{\circ}$ and $90^{\circ}$ bridge exercise conditions. Contraction difference of internal oblique muscle was significantly larger at $90^{\circ}$ than at $60^{\circ}$ within the SG (p<0.05). But within the UG, no significant contraction difference was shown. There was no significant contraction difference between the surface group and the unstable SG at $60^{\circ}$ condition and at $90^{\circ}$ condition in all measured muscles. Conclusions: The contraction difference is different for each muscle during bridge exercise with knee flexion $60^{\circ}$ and bridging exercise with knee flexion $90^{\circ}$. Muscle contraction difference is generally large when exercised on an unstable surface than a stable surface, but these are not statistically significant when bridging exercise is performed using dynamic air cushion for unstable surface.

Comparative Study of Cryostripping and Endovenous Laser Therapy for Varicose Veins: Mid-Term Results

  • Lee, Kwang Hyoung;Chung, Jae Ho;Kim, Kwang Taik;Lee, Sung Ho;Son, Ho Sung;Jung, Jae Seung;Kim, Hee Jung;Lee, Seung Hun
    • Journal of Chest Surgery
    • /
    • v.48 no.5
    • /
    • pp.345-350
    • /
    • 2015
  • Background: Conventional stripping is considered to be the standard procedure for great saphenous vein (GSV) varicosities, but many other alternative treatments such as cryostripping, endovenous laser therapy (EVLT), radiofrequency ablation, and ultrasound-guided foam sclerotherapy have been developed. Among them, both cryostripping and laser therapy have been reported to be less traumatic, with lower rates of complications and recurrences when compared to conventional stripping. To compare the efficacy of these treatments, we have analyzed and compared the mid-term clinical outcomes of cryostripping and EVLT. Methods: Patients diagnosed with varicose veins of the GSV and treated with cryostripping or laser therapy between September 2008 and April 2013 were enrolled in this study. Duplex ultrasonography was used for the diagnosis and evaluation of varicosity and reflux, and the clinical-etiology-anatomy-pathophysiology classification was used to measure the clinical severity. The symptoms, Venous Clinical Severity Score (VCSS), recurrence rates, and complication rates of the cryostripping and laser therapy groups were analyzed and compared. Results: A total of 68 patients were enrolled in this study. 32 patients were treated with cryostripping, and 36 patients were treated with laser therapy. The median follow-up period was 29.6 months. Recurrence was noted in three patients from the cryostripping group and in two patients from the EVLT group. There was no difference in the VCSS score, operative time, duration of hospital stay, and complication rate between the cryostripping group and the EVLT group. Conclusion: The mid-term clinical outcomes of cryostripping were not inferior to those of EVLT. Further, considering its cost-effectiveness, cryostripping seems to be a safe and feasible method for the treatment of varicose veins.

Relationship between corpus luteum size as determined by ultrasonography and milk progesterone concentration during the estrous cycle in dairy cows (젖소에서 발정주기중 초음파 진단장치로 측정된 황체의 크기와 progesterone 농도와의 관계)

  • Son, Chang-ho;Kang, Byong-kyu;Choi, Han-sun
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.4
    • /
    • pp.833-841
    • /
    • 1995
  • Ultrasonography was used to measure the corpus luteum area for determining the relationships between corpus luteum size and milk progesterone concentration during the estrous cycle in 16 dairy cows. Cows were classified retrospectively into cows that had corpus luteum with(n=P) and without(n=7) cavity. Ultrasound examination and collection of milk samples for progesterone assay were performed with 2 day intervals from Days 0 to 12, and then daily from Day 14 to the day of the next ovulation. The means for corpus luteum area and for milk progesterone concentration during the estrous cycle were not significantly different between cows that had corpus luteum with and without cavity. The correlation coefficients between corpus luteum area and milk progesterone concentration during luteal development (Days 2 to 8) were 0.71(p<0.0001) and 0.74(p<0.0001) for corpus luteum with and without cavity, respectively, during luteal regression(Days -6 to 0 relative to the next ovulation) 0.73(p<0.0001) and 0.76(p<0.0001), respectively. The correlation coefficients combined fur both stages of estrous cycle and both luteal statuses were 0.70(p<0.0001). These results indicate that corpus luteum area is significantly correlated to milk progesterone concentration, and ultrasonographic assessment of the corpus luteum is a reliable method fur estimating peripheral progesterone concentrations during the estrous cycle in cows.

  • PDF

Gender Differences in Physiological Effects of a Transient Exposure to Experimental Noise

  • Hyun, Kyung-Yae;Kim, Chong-Rak;Kim, Hwa-Il;Kim, Young-Hwal;Choi, Seok-Cheol
    • Biomedical Science Letters
    • /
    • v.12 no.4
    • /
    • pp.375-383
    • /
    • 2006
  • The physiological responses following stress are different in individual or personality. We performed this study to clarify gender differences in influences of noise stress on physiological factors. 70 healthy subjects, which was divided man (n=30) and woman (n=40) groups, were exposed to 85 decibels of excavator noise for 15 minutes. Cardiac factors such as heart rate (HR), systolic and diastolic blood pressures (SBP and DBP, respectively), and heart rate-systolic pressure product (RPP) were determined. Transcranial Doppler ultrasound (TCD) was used to measure mean blood flow velocity (Vm), pulsatility index (PI), and resistance index (RI) in the middle, anterior and posterior cerebral arteries (MCA, ACA and PCA, respectively) before and during noise exposure. Cortisol level and hematological variables were also measured before (baseline) and immediately after the end of noise exposure. In the both groups HR, SBP, and RPP significantly decreased during noise exposure (P<0.05) but not significantly different between two groups (P>0.05). Vms of three cerebral arteries in man group decreased, whereas Vm of PCA in woman group fell during noise exposure (P<0.05). Vm, PI and RI in MCA and ACA during noise exposure were low in man group compared with woman group (P<0.05). Vm of PCA was low, whereas PI and RI of PCA were high in man group compared with woman group during noise exposure (P<0.05). Total leukocyte and red blood cell (RBC) counts slightly decreased during noise exposure but not significant (P>0.05). Levels in hematological variables decreased but not significant changed following noise exposure. Decreased rate of total leukocyte in man group was higher (P<0.05). Cortisol levels in the both groups decreased immediately after the end of noise exposure, while the decreased rate in man group was greater than that in woman group (p<0.05). These findings indicate that a transient exposure to experimental excavator noise may cause decreased changes in cardiac factors, cerebral hemodynamics and cortisol levels and the changes may be greater in men than in women.

  • PDF

Risk Analysis of Factors for Metabolic Diseases according to the Epicaridal Adipose Tissue Thickness - which Focused on the Presented Subjects with Asymptomatic Screening Purposes (심장외막의 지방두께에 따른 대사질환의 위험도 분석 - 무증상의 검진목적으로 내원한 대상자를 위주로)

  • Kim, Sun-Hwa;Kim, Jung-Hoon;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.7
    • /
    • pp.476-483
    • /
    • 2016
  • Epicardial adipose tissue(EAT) is metabolically active endocrine organ that secretes several hormones in fat thickness is a risk factor for cardiovascular disease and metabolic disorders. This study was to measure and then using ultrasound epicardial adipose tissue thickness, abdominal subcutaneous fat thickness in the target group correlates and general blood properties and characteristics, and presents a local thickness for prediction of metabolic disorders. Results epicardal adipose tissue of the average thickness measured in each of the subjects was 8.890mm, 4.783mm, 4.777, 6.147mm in each section. Showed the epicardial adipose tissue in correlation with the average thickness of the risk factors age, BMI, SBP, LDH, LDL, TC is a positive correlation relationship(p<0.05) in each section. In particular, the thickness of the metabolic disorders epicardial adipose tissue thickness, abdominal subcutaneous compared to subjects that do not have the risk subjects with a risk factor for fat significantly higher(p<0.05). It showed the most reliable that can be cut-off value of 8.950mm obtained with 66.7 % sensitivity and 80 % specificity for predicting the risk of metabolic disorders.

Location Studies of Prostate Volume Measurement by using Transrectal Ultrasonography: Experimental Study by Self-Produced Prostate Phantom (경직장초음파를 이용한 전립선 볼륨측정 시의 위치 연구: 전립선모형 제작과 실험)

  • Kim, Yun-Min;Yoon, Joon;Byeon, II-kyun;Lee, Hoo-Min;Kim, Hyeong- Gyun
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.437-442
    • /
    • 2015
  • Accurate volume measurement of the prostate is a significant role in determining the result of diagnosis and treatment of benign prostate hyperplasia. The purpose of this study was to determine, when measuring prostate volume by TRUS, whether location is more accurately determined by transaxial or longitudinal scanning. With reference to the patient's image, it was produced six prostate model. It compares the actual volume and the measurement volume, and find the optimal measurement position of each specific model. Prostate volume measured by TRUS closely correlates with prostate phantom volume. There was no significant difference(p = .156). To measure the accurate volume of prostate with focal protrusion, its length should be measured exclude the protrusions.

A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants (원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구)

  • Kim, Kyung-Cho;Kang, Suk-Chull;Goo, Charles;Kim, Jin-Ho;Park, Jae-Seok;Joo, Geum-Jong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.325-330
    • /
    • 2004
  • Several kinds of low voltage cables have been used in nuclear power plants for the supply of electric power, supervision, and the propagation of control signals. These low voltage tables must be inspected for safe and stable operation of nuclear power plants. In particular, the degradation diagnosis to estimate the integrity of low voltage rabies has recently been emphasized according to the long use of nuclear power plants. In order to evaluate their degradation, the surrounding temperature, hardness of insulation material, elongation at breaking point (EAB), etc. have been used. However, the measurement of temperature or hardness is not useful because of the absence of quantitative criteria; the inspection of a sample requires turning off of the power plant power; and, the electrical inspection method is not sufficiently sensitive from the initial through the middle stage of degradation. In this research, based on the theory that the ultrasonic velocity changes with relation to the degradation of the material, we measured the ultrasonic velocity as low voltage cables were degraded. To this end, an ultrasonic degradation diagnosis device was developed and used to measure the ultrasonic velocity with the clothing on the cable, and it was confirmed that the ultrasonic velocity changes according to the degradation of low voltage cables. The low voltage cables used in nuclear power plants were degraded at an accelerated rate, and EAB was measured in a tensile test conducted after the measurement of ultrasonic velocity. With the increasing degradation degree, the ultrasonic velocity decreased, whose potential as a useful parameter for the quantitative degradation evaluation was thus confirmed.

Puerarin pretreatment attenuates cardiomyocyte apoptosis induced by coronary microembolization in rats by activating the PI3K/Akt/GSK-3β signaling pathway

  • Chen, Zhi-Qing;Zhou, You;Huang, Jun-Wen;Chen, Feng;Zheng, Jing;Li, Hao-Liang;Li, Tao;Li, Lang
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.25 no.2
    • /
    • pp.147-157
    • /
    • 2021
  • Coronary microembolization (CME) is associated with cardiomyocyte apoptosis and cardiac dysfunction. Puerarin confers protection against multiple cardiovascular diseases, but its effects and specific mechanisms on CME are not fully known. Hence, our study investigated whether puerarin pretreatment could alleviate cardiomyocyte apoptosis and improve cardiac function following CME. The molecular mechanism associated was also explored. A total of 48 Sprague-Dawley rats were randomly divided into CME, CME + Puerarin (CME + Pue), sham, and sham + Puerarin (sham + Pue) groups (with 12 rats per group). A CME model was established in CME and CME + Pue groups by injecting 42 ㎛ microspheres into the left ventricle of rats. Rats in the CME + Pue and sham + Pue groups were intraperitoneally injected with puerarin at 120 mg/kg daily for 7 days before operation. Cardiac function, myocardial histopathology, and cardiomyocyte apoptosis index were determined via cardiac ultrasound, hematoxylin-eosin (H&E) and hematoxylin-basic fuchsin-picric acid (HBFP) stainings, and TdT-mediated dUTP nick-end labeling (TUNEL) staining, respectively. Western blotting was used to measure protein expression related to the phosphoinositide 3-kinase (PI3K)/protein kinase B (Akt)/glycogen synthase kinase-3β (GSK-3β) pathway. We found that, puerarin significantly ameliorated cardiac dysfunction after CME, attenuated myocardial infarct size, and reduced myocardial apoptotic index. Besides, puerarin inhibited cardiomyocyte apoptosis, as revealed by decreased Bax and cleaved caspase-3, and up-regulated Bcl-2 and PI3K/Akt/GSK-3β pathway related proteins. Collectively, puerarin can inhibit cardiomyocyte apoptosis and thus attenuate myocardial injury caused by CME. Mechanistically, these effects may be achieved through activation of the PI3K/Akt/GSK-3β pathway.

Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study (동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발)

  • Lee, Suk;Lee, Sang-Hoon;Shin, Dong-Ho;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.122-125
    • /
    • 2004
  • In radiotherapy of tumors in liver, enough planning target volume (PTV) margins are necessary to compensate breathing-related movement of tumor volumes. To overcome the problems, this study aims to obtain patients' body movements by using a moving phantom and an ultrasonic sensor, and to develop respiration gating techniques that can adjust patients' beds by using reversed values of the data obtained. The phantom made to measure patients' body movements is composed of a microprocessor (BS II, 20 MHz, 8K Byte), a sensor (Ultra-Sonic, range 3 cm ${\sim}$3 m), host computer (RS232C) and stepping motor (torque 2.3Kg) etc., and the program to control and operate it was developed. The program allows the phantom to move within the maximum range of 2 cm, its movements and corrections to take place in order, and x, y and z to move successively. After the moving phantom was adjusted by entering random movement data(three dimensional data form with distance of 2cm), and the phantom movements were acquired using the ultra sonic sensor, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using guinea pigs, the real-time respiration gating techniques were drawn by operating the phantom with the reversed values of the data. The result of analyzing the acquisition-correction delay time for the three types of data values and about each value separately shows that the data values coincided with one another within 1% and that the acquisition-correction delay time was obtained real-time (2.34 ${\times}$ 10$^{-4}$sec). This study successfully confirms the clinic application possibility of respiration gating techniques by using a moving phantom and an ultra sonic sensor. With ongoing development of additional analysis system, which can be used in real-time set-up reproducibility analysis, it may be beneficially used in radiotherapy of moving tumors.

  • PDF

Relationship Between Carotid Intima-Media Thickness Using Ultrasonography and Diagnostic Indices of Metabolic Syndrome (초음파를 이용한 경동맥 내-중막 두께와 대사증후군 진단지표의 연관성)

  • Ko, Kyung-Sun;Heo, Kyung-Hwa;Won, Yong-Lim;Lee, Sung-Kook;Kim, Ki-Woong
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.285-291
    • /
    • 2009
  • The aim of the present study was undertaken to investigate the association between diagnostic indices of metabolic syndrome(MetS) with carotid intima-media thickness using ultrasonography. The participants in the study were 315 male employees without carotid atherosclerosis and other cardiovascular disease. This study was approved by the Institutional Review Board of Occupational Safety and Health Research Institute. Written informed consent for the participants in this study was obtained from all individuals. Anthropometric parameters and biochemical characteristics were done using each specific equipments and the NCEP-ATP III criteria were used to define MetS. They were examined by B-mode ultrasound to measure the carotid intima-media thickness(carotid IMT) at the near and far walls of common carotid and bifurcation(bulb). The mean carotid IMT was $0.739{\pm}0.137\;mm$ and it's thickness significantly increased with the increase in age. Also, amounts of systolic and diastolic blood pressure, triglyceride and fasting glucose were significantly increased with the increase in age. Carotid IMT were significantly correlated with BMI(r=0.170, p=0.004), systolic(r=0.148, p=0.011) and diastolic blood pressure(r=0.123, p=0.036) and HDL-cholesterol(r=-0.164, p=0.005). On multiple logistic regression analysis for the diagnostic indices of MetS, carotid IMT were significantly associated with blood pressure(OR=4.220, p<0.01) and MetS(OR=1.301, p<0.05). The results indicate that blood pressure and MetS are important risk factors for carotid atherosclerosis.

  • PDF