• Title/Summary/Keyword: Ultrasound head

Search Result 99, Processing Time 0.027 seconds

Result of a Long-Term Follow-Up of Arthroscopic Partial Repair for Massive Irreparable Rotator Cuff Tears Using a Biceps Long Head Auto Graft (봉합 불가능한 광범위 회전근 개 파열에서 상완 이두근 건 장두를 이용한 관절경하 부분 봉합술의 장기 추적 관찰 결과)

  • Ko, Sang-Hun;Park, Ki-Bong;Park, Gil-Young;Kwon, Sun-Hwan;Kim, Myung-Seo;Park, Sun-Jae
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.135-142
    • /
    • 2020
  • Purpose: This paper presents the long term follow-up results of arthroscopic partial repair for massive irreparable rotator cuff tears using a biceps long head auto graft. Materials and Methods: Forty-one patients with massive irreparable rotator cuff tear, who underwent arthroscopic repair, were reviewed retrospectively. Patients who underwent arthroscopic partial repair using a biceps long head auto graft were assigned to group 1, and patients in group 2 underwent arthroscopic partial repair alone. Patients with a less than 50% partial tear of the long head biceps tendon were included in this study. The clinical scores were measured using a visual analogue pain scale (VAS) for pain, range of motion (ROM), The University of California, Los Angeles shoulder score (UCLA), American Shoulder and Elbow Surgeons Shoulder Score (ASES), and Korean Shoulder Scoring System (KSS) scores preoperatively and at the final follow-up. The acromiohumeral interval (AHI) was measured using plain radiographs taken preoperatively and at the final follow-up, and re-tear was evaluated using postoperative ultrasound or magnetic resonance imaging at the last follow-up. Results: The mean age of the patients was 62.1±12.7 years, and the mean follow-up period was 90.3±16.8 months. No significant differences in the VAS and ROM (forward flexion, external rotation, internal rotation) were found between the two groups (p=0.179, p=0.129, p=0.098, p=0.155, respectively). The UCLA (p=0.041), ASES (p=0.023), and KSS (p=0.019) scores showed functional improvements in group 1 compared to group 2. At the last follow-up, the measured AHI values were 9.46±0.41 mm and 6.86±0.64 mm in group 1 and 2, respectively (p=0.032). Re-tear was observed in six out of 21 cases (28.6%) in group 1 and nine out of 20 cases (45.0%) in group 2; the retear rate was significantly lower in group 1 than in group 2 (p=0.011). Conclusion: Arthroscopic partial repair for a massive irreparable rotator cuff tear using a biceps long head auto graft has significant clinical usefulness in functional recovery and decreases the re-tear rates after surgery than arthroscopic partial repair alone, showing favorable results after a long-term follow-up.

The Effects of ESWT and US on Muscle Power, Pain and Muscle Tension at Trigger Point of the Scapular Inter Angle (견갑골 내측 상부의 발통점에 체외충격파와 초음파 적용시 통증과 피부두께, 근력변화에 미치는 영향)

  • Lee, Seung-Hyub;Pi, Eo-Ra;Jung, Ha-Ney;Lee, Ho-Seok;Joo, Da-Sol;Lee, Seung-Hee;Choi, Min-Hee;Choi, Hyun-Ji;Hong, Young-In;Kim, Ji-Eun;Han, Sang-Wan
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.7 no.1
    • /
    • pp.29-34
    • /
    • 2009
  • Purpose : This study aims to investigate into the change in muscle power, pain and muscle tension upon application of extracorporeal shock wave therapy (ESWT) and ultrasound (US) at trigger point (TrP) of the Scapular inter angle. Methods : In total of 24 human subjects that experience pain upon stimulation at the scapular inter angle were recruited. They were divided into three groups: control, ESWT and US group. Each group was subjected to appropriate stimulation three times per week for four weeks except the control group which had no restrictions in lifestyle. The ESWT group was subjected to Extracorporeal Shock Wave Therapy with a 2 $cm^2$ head, 20 times at speed of application of 60 pulses/min and depth of intrusion of 25 mm Whereas the US group was subject to Ultra sound therapy with 1$cm^2$ head, 1 MHz in frequency, 1.5 W/$cm^2$ of strength with five minutes of continuous application. Measurements were performed immediately prior to and at the end of the experiment. Results : There was no statistical significance in the change in muscle tension and muscle power as well as the difference between both groups before and after the experiment. VAS and VRS, all of which indicates changes in pain level, had statistically significant differences between them in pretest posttest comparisons. However, ESWT was superior to US in terms of decreasing muscle tension and pain while increasing muscle power. Conclusion : This study has made it evident that ESWT is far more reasonable to apply to TrP.

Clinicopathologic Characteristics of Incidentally Discovered Thyroid Carcinomas (갑상선 우연암종의 임상병리적 특성)

  • Chung Woung-Youn;Cheong Jae-Ho;Chang Hang-Seok;Park Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.16 no.1
    • /
    • pp.64-68
    • /
    • 2000
  • Objectives: With the recent advances and increasing use of imaging techniques in examination of the neck, the incidence of incidentally discovered thyroid carcinoma has been increasing. This study was carried out to evaluate the clinicopathologic characteristics of incidental thyroid carcinomas and to find optimal therapeutic strategies for these lesions. Materials & Methods: From Jan. 1988 to Aug. 1998, 1,053 patients were operated on for thyroid cancer, of whom 127(12.1%) had incidentally discovered thyroid cancers which were identified during routine health checkups(n=40), diagnostic procedures for unrelated medical conditions(n=39) and mass screening for thyroid cancer(n=48). The preoperative diagnosis was obtained by ultrasound-guided FNAB and the extent of surgery was determined based on frozen section examinations, as well as prognostic factors and gross findings at the time of surgery. Results: There were 6 men and 121 women with a mean age of 45.9 years. Histopathological diagnosis included papillary carcinomas(n=1l9), follicular carcinomas(n=6), poorly differentiated carcinoma(n=l) and medullary carcinoma(n=1). Thirty patients(23.6%) had multifocallesions. The mean diameter of the tumors was 1.1 cm(0.2-3.4 cm). Capsular invasions were found in 53 patients(41.7%) and nodal metastases in 41(32.3%). The surgical procedures used were: 90 less-than total thyroidectomies and 37 total thyroidectomies with central neck node dissection. Lateral neck dissection was added in 5 patients. According to TNM staging, 79 patients(63.2%) were at stage I, 15(12.0%) at stage II, 31(24.8%) at stage III and 0(0.0%) at stage IV. By AMES scoring system, 102 patients(81.6%) were in the low-risk group and 23(18.4%) in the high-risk group. And by MACIS scoring system, 103(86.6%) of 119 papillary thyroid cancer patients were less than 6. Conclusions: The clinicopathological characteristics of incidentally discovered thyroid carcinomas are similar to ordinary thyroid carcinomas. The treatment of choice should be individualized based on the particular clinical situation encountered, as in ordinary thyroid carcinomas.

  • PDF

Development of rotational pulse-echo ultrasonic propagation imaging system capable of inspecting cylindrical specimens

  • Ahmed, Hasan;Lee, Young-Jun;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.657-666
    • /
    • 2020
  • A rotational pulse-echo ultrasonic propagation imager that can inspect cylindrical specimens for material nondestructive evaluations is proposed herein. In this system, a laser-generated ultrasonic bulk wave is used for inspection, which enables a clear visualization of subsurface defects with a precise reproduction of the damage shape and size. The ultrasonic waves are generated by a Q-switched laser that impinges on the outer surface of the specimen walls. The generated waves travel through the walls and their echo is detected by a Laser Doppler Vibrometer (LDV) at the same point. To obtain the optimal Signal-to-Noise Ratio (SNR) of the measured signal, the LDV requires the sensed surface to be at a right angle to the laser beam and at a predefined constant standoff distance from the laser head. For flat specimens, these constraints can be easily satisfied by performing a raster scan using a dual-axis linear stage. However, this arrangement cannot be used for cylindrical specimens owing to their curved nature. To inspect the cylindrical specimens, a circular scan technology is newly proposed for pulse-echo laser ultrasound. A rotational stage is coupled with a single-axis linear stage to inspect the desired area of the specimen. This system arrangement ensures that the standoff distance and beam incidence angle are maintained while the cylindrical specimen is being inspected. This enables the inspection of a curved specimen while maintaining the optimal SNR. The measurement result is displayed in parallel with the on-going inspection. The inspection data used in scanning are mapped from rotational coordinates to linear coordinates for visualization and post-processing of results. A graphical user interface software is implemented in C++ using a QT framework and controls all the individual blocks of the system and implements the necessary image processing, scan calculations, data acquisition, signal processing and result visualization.

The Effects of Bridge Exercise with Contraction of Hip Adductor Muscles on Thickness of Abdominal Muscles (고관절 내전근 수축을 이용한 교각운동이 복부근육의 두께에 미치는 영향)

  • Lee, Geon-Cheol;Bae, Won-Sik;Kim, Chi-Hyok
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.2
    • /
    • pp.233-242
    • /
    • 2014
  • PURPOSE: The purpose of this study was to determine the correlation between the hip adductor muscles and abdominal muscles during bridge exercise. METHOD: Participants who met the criteria for this study(n=36) were divided into the three groups. The first experimental group performed normal bridge exercises and the second group performed bridge exercises with the contraction of the hip adductor muscles and the control group didn't perform any exercise. Transversus abdominis muscle thickness was measured by ultrasound imaging with a special transducer head device, at pre exercise, after 2 weeks, 4 weeks, and 6 weeks. RESULT: Data were analyzed using repeated ANOVA with the level of significance set at ${\alpha}=.05$. Transversus abdominis muscle thickness was influenced by contraction of the hip adductor muscles during bridge exercise in people without lower back pain. Compared with normal bridge exercise, transversus abdominis muscle thickness significantly increased in thickness during bridge exercise with contraction of the hip adductor muscles(p<.05). CONCLUSION: The results from this study showed that contraction of the hip adductor muscles during bridge exercise increased change in the transversus abdominis muscle thickness. These results can be a good source to prevent low back pain due to hip adductor weakness. Therefore, inducing activation of hip adductor with abdominal stabilizing exercise is more effective in patients with low back pain.

A Study on a Mask R-CNN-Based Diagnostic System Measuring DDH Angles on Ultrasound Scans (다중 트레이닝 기법을 이용한 MASK R-CNN의 초음파 DDH 각도 측정 진단 시스템 연구)

  • Hwang, Seok-Min;Lee, Si-Wook;Lee, Jong-Ha
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.183-194
    • /
    • 2020
  • Recently, the number of hip dysplasia (DDH) that occurs during infant and child growth has been increasing. DDH should be detected and treated as early as possible because it hinders infant growth and causes many other side effects In this study, two modelling techniques were used for multiple training techniques. Based on the results after the first transformation, the training was designed to be possible even with a small amount of data. The vertical flip, rotation, width and height shift functions were used to improve the efficiency of the model. Adam optimization was applied for parameter learning with the learning parameter initially set at 2.0 x 10e-4. Training was stopped when the validation loss was at the minimum. respectively A novel image overlay system using 3D laser scanner and a non-rigid registration method is implemented and its accuracy is evaluated. By using the proposed system, we successfully related the preoperative images with an open organ in the operating room

Hepatic Encephalopathy in a Connemara Pony

  • Park, Kyung-won;Lee, Eun-bee;Park, Young-jae;Jung, Ji-Youl;Kim, Jae-Hoon;Jeong, Hyohoon;Seo, Jong-pil
    • Journal of Veterinary Clinics
    • /
    • v.38 no.6
    • /
    • pp.299-304
    • /
    • 2021
  • A 3-year-old female Connemara pony was referred to Jeju National University Equine Hospital because of weight loss and prolonged anorexia. On admission, heart and respiratory rates were slightly elevated while body temperature was within the normal range. The color of the conjunctival and oral mucosa was yellowish pink. The blood chemistry results showed that total bilirubin, aspartate aminotransferase, and gamma-glutamyl transferase levels were remarkably elevated while blood urea nitrogen was within the reference range. Transcutaneous abdominal ultrasound revealed an enlarged right lobe of the liver with prominently increased parenchymal echogenicity, reduced hepatic vessels, and rounded caudal border. The pony was tentatively diagnosed with chronic hepatitis and icterus; rest and supportive treatments were provided. Clinical signs aggravated on day 2 with hind quarter paresis and cranial nerve signs such as circling, drooping, jerking, and head pressing against walls. Recumbency and generalized ataxia (grade 5/5) were shown on day 3. Plasma ammonia concentration on day 3 was as high as 656 µmol/L. Necropsy and histopathologic examinations strongly supported a diagnosis of hepatic encephalopathy. This case of hepatic encephalopathy exhibited rapid progress from low to terminal grade within 4 days in a Connemara pony. The results provide well-established clinical and pathological data for future application.

Granular Cell Tumor of the Axillary Accessory Breast: A Case Report (액와부 부유방에 발생한 과립 세포 종양: 증례 보고)

  • Youn Joo Jung;Kyung Jin Nam;Ki Seok Choo;Kyeyoung Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.275-279
    • /
    • 2023
  • Granular cell tumors (GCTs) are rare benign soft tissue tumors that can occur throughout the body, particularly the head and neck; only 5%-8% of GCTs occur in the breast. We report a case of a GCT of the axillary accessory breast, which is a rare location of this tumor. A 50-year-old woman had a 2-month history of a palpable mass in the left axilla. Physical examination, as well as mammographic and ultrasonographic findings suggested a breast malignancy. Histopathological examination showed a benign GCT, and wide local excision was performed. The patient has remained disease-free over 2 years postoperatively. Although most GCTs are benign, wide complete resection of the tumor and follow-up are required considering the possibility of recurrence. The radiologist should know the characteristics of GCTs as a differential diagnosis of breast and axillary lesions to prevent unnecessary treatment.

Evaluation of Dose and Position Compensation of Parotid Gland Using CT On-rail System in Head-and-Neck Cancer (두경부 암환자 치료 시 CT On-rail System을 이용한 이하선의 위치 보정 및 선량 평가)

  • Jang, Hyeong-Jun;Im, Chung-Geun;Chun, Geum-Sung;Jeong, Il-Seon;Kim, Hoi-Nam
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • Purpose: The checking method of target and normal structure are used by MVCBCT, KVCBCT, CT On-rail System, Ultrasound in H&N cancer patient. In case of MVCT, the utilization of bone structure is valuable to check around tissue. But the utilization of soft tissue is not enough. The point of this paper is dose variation in movable parotid and changeable volume of H&N cancer patient of CT On-rail System. Materials and Methods: The object of H&N cancer patient is 5 in this hospital. The selected patient are scanned ARTISTE CT Vision (CT On-ral System) a triweekly. After CT scanning, tranfered coordinates are obtained by movable of parotid gland comparison with planning image. Checking for the changeable volume of parotid gland. A Obtained CT image are tranfered to the RTP System. So dose variation are checked by following changed volume. Results: The changes of target coordinate by the parotid gland movement are X: -0.4~0.4 cm, Y: -0.4~0.3 cm, Z: -0.3~0.3 cm. the volume of GTV is decreased to about 7.11%/week and then both parotid gland volume are shrinked about 4.81%/week (Lt), 2.91%/week (Rt). At the same time, each parotid gland are diminished in radiation dose as 3.66%/week (Lt), 2.01%/week. Conclusion: Images from CT on the rail System which are able to aquire the better quality images of soft tissue in Target area than MVCBCT. After replanning and dose redistribution by required images, It could gain not only the correction of the patient set-tup errors but exact dose distribution. Accordingly, the delivery of compensated dose, It makes that we could do Adaptive Targeting Radiotherapy and need Real Time Adaptive Targeting Radiotherapy by reduce beam delivary time.

  • PDF

In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma (직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Lee, Hwang Kyu;Jee, Keum Nahn;Hong, Sujin;Koh, Jae Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Purpose : To evaluate and compare the accuracy of magnetic resonance imaging (MRI) and ultrasound (US) for detection and estimation of invasion depth of colorectal carcinoma (CRC) by correlation with histopathologic findings in vitro, and to find out the best MR pulse sequence for accurate delineation of tumor from surrounding normal tissue. Materials and Methods: Resected specimens of CRC from 45 patients were examined about tumor detectability and invasion depth of US using high frequency (5-17 MHz) linear transducer in a tube filled with normal saline and MRI in a 8-channel quadrate head coil. The institutional review board approved this study and informed consent was waived. MRI with seven pulse sequences of in- and out-of-phases gradient echo T1 weighted images, fast spin echo T2 weighted image and its fat suppression image, fast imaging employing steady-state acquisition (FIESTA) and its fat suppression image, and diffusion weighted image (DWI) were performed. In each case, both imaging findings of MRI and US were evaluated independently for detection and estimation of invasion depth of tumor by consensus of two radiologists and were compared about diagnostic accuracy according to the histopathologic findings as reference standard. Seven MR pulse sequences were evaluated on the point of accurate delineation of tumor from surrounding normal tissue in each specimen. Results: In specimens of CRC, both imaging modalities of MRI (91.1%) and US (86.7%) showed relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of tumor. In early CRC, diagnostic accuracy of US was 87.5% and that of MRI was 75.0%. There was no statistically significant difference between two imaging modalities (p > 0.05). The best pulse sequence among seven MR sequences for accurate delineation of tumor from surrounding normal tissue in each specimen of CRC was fast spin echo T2 weighted image. Conclusion: MRI and US show relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of resected specimen of CRC. The most excellent pulse sequence of MRI for accurate delineation of tumor from surrounding normal tissue in CRC is fast spin echo T2 weighted image.