• Title/Summary/Keyword: Ultrasound head

Search Result 96, Processing Time 0.024 seconds

Development of rotational pulse-echo ultrasonic propagation imaging system capable of inspecting cylindrical specimens

  • Ahmed, Hasan;Lee, Young-Jun;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.657-666
    • /
    • 2020
  • A rotational pulse-echo ultrasonic propagation imager that can inspect cylindrical specimens for material nondestructive evaluations is proposed herein. In this system, a laser-generated ultrasonic bulk wave is used for inspection, which enables a clear visualization of subsurface defects with a precise reproduction of the damage shape and size. The ultrasonic waves are generated by a Q-switched laser that impinges on the outer surface of the specimen walls. The generated waves travel through the walls and their echo is detected by a Laser Doppler Vibrometer (LDV) at the same point. To obtain the optimal Signal-to-Noise Ratio (SNR) of the measured signal, the LDV requires the sensed surface to be at a right angle to the laser beam and at a predefined constant standoff distance from the laser head. For flat specimens, these constraints can be easily satisfied by performing a raster scan using a dual-axis linear stage. However, this arrangement cannot be used for cylindrical specimens owing to their curved nature. To inspect the cylindrical specimens, a circular scan technology is newly proposed for pulse-echo laser ultrasound. A rotational stage is coupled with a single-axis linear stage to inspect the desired area of the specimen. This system arrangement ensures that the standoff distance and beam incidence angle are maintained while the cylindrical specimen is being inspected. This enables the inspection of a curved specimen while maintaining the optimal SNR. The measurement result is displayed in parallel with the on-going inspection. The inspection data used in scanning are mapped from rotational coordinates to linear coordinates for visualization and post-processing of results. A graphical user interface software is implemented in C++ using a QT framework and controls all the individual blocks of the system and implements the necessary image processing, scan calculations, data acquisition, signal processing and result visualization.

The Effects of Bridge Exercise with Contraction of Hip Adductor Muscles on Thickness of Abdominal Muscles (고관절 내전근 수축을 이용한 교각운동이 복부근육의 두께에 미치는 영향)

  • Lee, Geon-Cheol;Bae, Won-Sik;Kim, Chi-Hyok
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.2
    • /
    • pp.233-242
    • /
    • 2014
  • PURPOSE: The purpose of this study was to determine the correlation between the hip adductor muscles and abdominal muscles during bridge exercise. METHOD: Participants who met the criteria for this study(n=36) were divided into the three groups. The first experimental group performed normal bridge exercises and the second group performed bridge exercises with the contraction of the hip adductor muscles and the control group didn't perform any exercise. Transversus abdominis muscle thickness was measured by ultrasound imaging with a special transducer head device, at pre exercise, after 2 weeks, 4 weeks, and 6 weeks. RESULT: Data were analyzed using repeated ANOVA with the level of significance set at ${\alpha}=.05$. Transversus abdominis muscle thickness was influenced by contraction of the hip adductor muscles during bridge exercise in people without lower back pain. Compared with normal bridge exercise, transversus abdominis muscle thickness significantly increased in thickness during bridge exercise with contraction of the hip adductor muscles(p<.05). CONCLUSION: The results from this study showed that contraction of the hip adductor muscles during bridge exercise increased change in the transversus abdominis muscle thickness. These results can be a good source to prevent low back pain due to hip adductor weakness. Therefore, inducing activation of hip adductor with abdominal stabilizing exercise is more effective in patients with low back pain.

A Study on a Mask R-CNN-Based Diagnostic System Measuring DDH Angles on Ultrasound Scans (다중 트레이닝 기법을 이용한 MASK R-CNN의 초음파 DDH 각도 측정 진단 시스템 연구)

  • Hwang, Seok-Min;Lee, Si-Wook;Lee, Jong-Ha
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.183-194
    • /
    • 2020
  • Recently, the number of hip dysplasia (DDH) that occurs during infant and child growth has been increasing. DDH should be detected and treated as early as possible because it hinders infant growth and causes many other side effects In this study, two modelling techniques were used for multiple training techniques. Based on the results after the first transformation, the training was designed to be possible even with a small amount of data. The vertical flip, rotation, width and height shift functions were used to improve the efficiency of the model. Adam optimization was applied for parameter learning with the learning parameter initially set at 2.0 x 10e-4. Training was stopped when the validation loss was at the minimum. respectively A novel image overlay system using 3D laser scanner and a non-rigid registration method is implemented and its accuracy is evaluated. By using the proposed system, we successfully related the preoperative images with an open organ in the operating room

Hepatic Encephalopathy in a Connemara Pony

  • Park, Kyung-won;Lee, Eun-bee;Park, Young-jae;Jung, Ji-Youl;Kim, Jae-Hoon;Jeong, Hyohoon;Seo, Jong-pil
    • Journal of Veterinary Clinics
    • /
    • v.38 no.6
    • /
    • pp.299-304
    • /
    • 2021
  • A 3-year-old female Connemara pony was referred to Jeju National University Equine Hospital because of weight loss and prolonged anorexia. On admission, heart and respiratory rates were slightly elevated while body temperature was within the normal range. The color of the conjunctival and oral mucosa was yellowish pink. The blood chemistry results showed that total bilirubin, aspartate aminotransferase, and gamma-glutamyl transferase levels were remarkably elevated while blood urea nitrogen was within the reference range. Transcutaneous abdominal ultrasound revealed an enlarged right lobe of the liver with prominently increased parenchymal echogenicity, reduced hepatic vessels, and rounded caudal border. The pony was tentatively diagnosed with chronic hepatitis and icterus; rest and supportive treatments were provided. Clinical signs aggravated on day 2 with hind quarter paresis and cranial nerve signs such as circling, drooping, jerking, and head pressing against walls. Recumbency and generalized ataxia (grade 5/5) were shown on day 3. Plasma ammonia concentration on day 3 was as high as 656 µmol/L. Necropsy and histopathologic examinations strongly supported a diagnosis of hepatic encephalopathy. This case of hepatic encephalopathy exhibited rapid progress from low to terminal grade within 4 days in a Connemara pony. The results provide well-established clinical and pathological data for future application.

Granular Cell Tumor of the Axillary Accessory Breast: A Case Report (액와부 부유방에 발생한 과립 세포 종양: 증례 보고)

  • Youn Joo Jung;Kyung Jin Nam;Ki Seok Choo;Kyeyoung Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.275-279
    • /
    • 2023
  • Granular cell tumors (GCTs) are rare benign soft tissue tumors that can occur throughout the body, particularly the head and neck; only 5%-8% of GCTs occur in the breast. We report a case of a GCT of the axillary accessory breast, which is a rare location of this tumor. A 50-year-old woman had a 2-month history of a palpable mass in the left axilla. Physical examination, as well as mammographic and ultrasonographic findings suggested a breast malignancy. Histopathological examination showed a benign GCT, and wide local excision was performed. The patient has remained disease-free over 2 years postoperatively. Although most GCTs are benign, wide complete resection of the tumor and follow-up are required considering the possibility of recurrence. The radiologist should know the characteristics of GCTs as a differential diagnosis of breast and axillary lesions to prevent unnecessary treatment.

Evaluation of Dose and Position Compensation of Parotid Gland Using CT On-rail System in Head-and-Neck Cancer (두경부 암환자 치료 시 CT On-rail System을 이용한 이하선의 위치 보정 및 선량 평가)

  • Jang, Hyeong-Jun;Im, Chung-Geun;Chun, Geum-Sung;Jeong, Il-Seon;Kim, Hoi-Nam
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • Purpose: The checking method of target and normal structure are used by MVCBCT, KVCBCT, CT On-rail System, Ultrasound in H&N cancer patient. In case of MVCT, the utilization of bone structure is valuable to check around tissue. But the utilization of soft tissue is not enough. The point of this paper is dose variation in movable parotid and changeable volume of H&N cancer patient of CT On-rail System. Materials and Methods: The object of H&N cancer patient is 5 in this hospital. The selected patient are scanned ARTISTE CT Vision (CT On-ral System) a triweekly. After CT scanning, tranfered coordinates are obtained by movable of parotid gland comparison with planning image. Checking for the changeable volume of parotid gland. A Obtained CT image are tranfered to the RTP System. So dose variation are checked by following changed volume. Results: The changes of target coordinate by the parotid gland movement are X: -0.4~0.4 cm, Y: -0.4~0.3 cm, Z: -0.3~0.3 cm. the volume of GTV is decreased to about 7.11%/week and then both parotid gland volume are shrinked about 4.81%/week (Lt), 2.91%/week (Rt). At the same time, each parotid gland are diminished in radiation dose as 3.66%/week (Lt), 2.01%/week. Conclusion: Images from CT on the rail System which are able to aquire the better quality images of soft tissue in Target area than MVCBCT. After replanning and dose redistribution by required images, It could gain not only the correction of the patient set-tup errors but exact dose distribution. Accordingly, the delivery of compensated dose, It makes that we could do Adaptive Targeting Radiotherapy and need Real Time Adaptive Targeting Radiotherapy by reduce beam delivary time.

  • PDF

In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma (직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Lee, Hwang Kyu;Jee, Keum Nahn;Hong, Sujin;Koh, Jae Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Purpose : To evaluate and compare the accuracy of magnetic resonance imaging (MRI) and ultrasound (US) for detection and estimation of invasion depth of colorectal carcinoma (CRC) by correlation with histopathologic findings in vitro, and to find out the best MR pulse sequence for accurate delineation of tumor from surrounding normal tissue. Materials and Methods: Resected specimens of CRC from 45 patients were examined about tumor detectability and invasion depth of US using high frequency (5-17 MHz) linear transducer in a tube filled with normal saline and MRI in a 8-channel quadrate head coil. The institutional review board approved this study and informed consent was waived. MRI with seven pulse sequences of in- and out-of-phases gradient echo T1 weighted images, fast spin echo T2 weighted image and its fat suppression image, fast imaging employing steady-state acquisition (FIESTA) and its fat suppression image, and diffusion weighted image (DWI) were performed. In each case, both imaging findings of MRI and US were evaluated independently for detection and estimation of invasion depth of tumor by consensus of two radiologists and were compared about diagnostic accuracy according to the histopathologic findings as reference standard. Seven MR pulse sequences were evaluated on the point of accurate delineation of tumor from surrounding normal tissue in each specimen. Results: In specimens of CRC, both imaging modalities of MRI (91.1%) and US (86.7%) showed relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of tumor. In early CRC, diagnostic accuracy of US was 87.5% and that of MRI was 75.0%. There was no statistically significant difference between two imaging modalities (p > 0.05). The best pulse sequence among seven MR sequences for accurate delineation of tumor from surrounding normal tissue in each specimen of CRC was fast spin echo T2 weighted image. Conclusion: MRI and US show relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of resected specimen of CRC. The most excellent pulse sequence of MRI for accurate delineation of tumor from surrounding normal tissue in CRC is fast spin echo T2 weighted image.

The Developmental Outcome of Fetal Mild Isolated Ventriculomegaly (단독 태아 경뇌실확장증의 임상적 예후)

  • Jeong, Myung Sook;Chun, Jung Mi;Kim, Kyung Ah;Ko, Sun Young;Lee, Yeon Kyung;Shin, Son Moon;Lee, Eu-Ree
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.8
    • /
    • pp.826-831
    • /
    • 2005
  • Purpose : This study is directed to evaluate standardized developmental test performances of infants and children who, as fetuses, had mild isolated cerebral ventriculomegaly diagnosed by ultrasound. Methods : All prenatal sonographic findings from 2001 to 2002 were evaluated. Live isolated mild ventriculomegaly(IMVM) of 10-15 mm were observed in 95 cases(1.1 percent). Standardized developmental testing of 40 cases of IMVM and 36 cases in a comparison group were offered to parents Both groups of children were adjusted to normal antepatum subjects with respect to sex, race, indication for ultrasound and gestational age at the time of ultrasound. Test of cognitive and motor development(Bayley Scales of Infant Development, Second Edition; BSID-II) were administered by developmental examiners. Results : Forty cases and 34 comparison sujects completed the testing. The IMVM and comparison groups were similar with respect to parental age, gestational age, birth weight, familial socioeconomic status. The IMVM subjects scored lower than the comparison group on both the BSID-II, but there was not statistically significant. differences; metal development index(MDI)($92.7{\pm}12.9$ vs $94.7{\pm}14.1$, P=0.47) and psychomotor development index(PDI)($100.3{\pm}14.1$ vs $101.3{\pm}10.7$, P=0.75). Eleven cases(27.5 percent) of IMVM group and five cases(14.7 percent) of the comparison group were developmentally delayed, but most cases in both groups showed mild delays. Resolution or lack of progression, lateral ventricle diameter ${\leq}12mm$ and females were associated with better scores, but there were not statistically significant. Polarity, and head circumference were not related to later development. Conclusion : This study show children with MIVM did not delay performance in the developmental test, but we might suggest a tendency to increase the risk of mild developmental delay.

Studies on Variation of Characteristics in Hanwoo Steers by Pen and Group Size (한우 거세우의 군집크기에 따른 산육특성 연구)

  • Ha, J.J.;Rhee, Y.J.;Jang, W.J.;Kim, Y.W.;Shaogang, Li;Song, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.15 no.1
    • /
    • pp.9-16
    • /
    • 2009
  • This study, tasting 14 months, was conducted to investigate the effects of different pen size and group size on growing-fattening characteristics of Hanwoo steers. Forty-eight, 12-month-old Hanwoo steers($305.8{\pm}32.2\;kg$) were randomly assigned to three groups($35.28\;m^2$; n=4 heads, $70.56\;m^2$; n=8 heads, $105.84\;m^2$; n=12 heads) and reared in separate pens with a constant space allowance of $8.82m^2$ per head from 12 to 21 month of age and then regrouped to 4 heads per pen. A common diet including concentrate(limited) and forage(ad lib) was provided to all the animals. Images of live animal ultrasonic back fat thickness, longissimus muscle area and Marbling score were evaluated in three months interval from 12 months of age using an ultrasound equipment(HS-2000) at the 13th rib and lumber vertebra interface of left side. Significant differences of ADG was found mainly at $15{\sim}18$ month and $18{\sim}21$ month fattening stages(p<0.05). Marbling score(MS) was higher(p<0.05) in 12 heads group when compared with that of 4 and 8 heads groups after 18 months. Animals in 12 heads group had the lowest Average daily gain(ADG) but showed the highest longissimus muscle area(LMA) and marbling score(MS). In addition, Hanwoo steers in 12 heads group obtained a higher quality appearance(HQA) of 82.7% than that of other treatments. The results indicated that Hanwoo steers housed on large group size and pen size decreased their ADG but improved meat quality.

  • PDF

Extraction of Sternocleidomastoid Muscle for Ultrasound Images of Cervical Vertebrae (경추 초음파 영상에서 흉쇄유돌근 추출)

  • Kim, Kwang-Baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.11
    • /
    • pp.2321-2326
    • /
    • 2011
  • Cervical vertebrae are a complex structure and an important part of human body connecting the head and the trunk. In this paper, we propose a method to extract sternocleidomastoid muscle from ultrasonography images of cervical vertabrae automatically. In our method, Region of Interests(ROI) is extracted first from an ultrasonography image after removing unnecessary auxiliary information such as metrics. Then we apply Ends-in search stretching algorithm in order to enhance the contrast of brightness. Average binarization is then applied to those pixels which its brightness is sufficiently large. The noise part is removed by image processing algorithms. After extracting fascia encloses sternocleidomastoid muscle, target muscle object is extracted using the location information of fascia according to the number of objects in the fascia. When only one object is to be extracted, we search downward first to extract the target muscle area and then search from right to left to extract the area and merge them. If there are two target objects, we extract first from the upper-bound of higher object to the lower-bound of lower object and then remove the fascia of the target object area. Smearing technique is used to restore possible loss of the fat area in the process. The thickness of sternocleidomastoid muscle is then calculated as the maximum thickness of those extracted objects. In this experiment with 30 real world ultrasonography images, the proposed method verified its efficacy and accuracy by health professionals.