복부초음파를 이용한 상완혈(上脘穴)-췌장 수직거리 측정시스템의 재현성 반복성 평가실험-A Pilot Study- (Gage R&R Study on Abdominal Sonography for Measuring Distance from Sangwan (CV13) to Pancreas - A Pilot Study -)

  • 남동현
    • 대한한의진단학회지
    • /
    • 제14권2호
    • /
    • pp.75-84
    • /
    • 2010
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from Sangwan (CV13) to pancreas. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from CV13 to pancreas with a ultrasound device three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from CV13 to pancreas was 6.29. So we concluded that repeatability and reproducibility of the ultrasound device system for measuring distance from CV13 to pancreas was acceptable.

상완혈 자침시 복부 장기의 안전성 확보를 위한 초음파시스템의 신뢰도 측정 (Reliability Measurement of the Ultrasound for Safety of the Abdominal Organs on Acupuncturing Sangwan (CV13))

  • 김지혜;백태현
    • 대한한의진단학회지
    • /
    • 제15권2호
    • /
    • pp.203-214
    • /
    • 2011
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with a ultrasound device with three methods of 3.5 MHz convex probe and gel, 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad, three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver were 9.20 (9 MHz linear probe and gel), 14.70 (9 MHz linear probe and solid gel pad). So we concluded that repeatabilities and reproducibilities of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with the methods of 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad were acceptable.

로봇 지원 원격 초음파 영상진단을 위한 마스터-슬레이브 시스템의 개발 (Development of Master-slave System for Robot-assisted Remote Ultrasound Diagnosis)

  • 서준호;조장호;권오원
    • 로봇학회논문지
    • /
    • 제12권4호
    • /
    • pp.395-401
    • /
    • 2017
  • In this paper, we introduce a robot-assisted medical diagnostic system that enables remote ultrasound (US) imaging to be applied to the conventional telemedicine, which has been possible only with interviewing or a visual exam. In particular, a master-slave robot system is developed that ultrasonic diagnosis specialist can control the position and orientation of US probe in the remote place. The slave robot is designed to be compact, lightweight, and hand-held so that it can easily transfer to the remote healthcare center. Moreover, 6-degree-of-freedom (DOF) probe motion is possible by the robot design based on Stewart platform. The master device is also based on a similar structure of the slave robot. To connect master and slave system in the wide area network (WAN) environment, a hardware CODEC was developed. In this paper, we introduce the detail of each component and the results of the recent experiments conducted in the remote sites by the developed robotic ultrasound imaging system.

미용 치료 헬스케어를 위한 고강도 집속 초음파 장치 개발 연구 (A Study on the Development of High-intensity focused Ultrasound Device for the Beauty Treatment Health Care)

  • 이우철;고윤석
    • 한국전자통신학회논문지
    • /
    • 제11권12호
    • /
    • pp.1259-1264
    • /
    • 2016
  • 초음파 치료는 회복속도가 빠르고 안전하다는 이유로 피부거상치료와 관련된 미용분야에서 큰 관심을 받고 있다. 본 연구에서는 미용치료를 위한 고강도 집속 초음파 장치의 출력회로를 개발하였다, 고강도 집속 초음파 시스템의 미용치료분야에 대한 적용 가능성을 확인하기 위해 수중 청음기를 이용하여 3 차원 초음파 강도 에너지를 측정 분석하였다, 고강도 집속 초음파장치에 의해 미용 치료에 유용함을 확인하였다.

건축물에 설치된 태양광발전설비를 위한 세척장치의 편익-비용 분석 (An Benefit-cost Analysis of the Cleaning Device for Photovoltaic Power Generation Systems in Buildings)

  • 김재엽;원종성
    • 한국건축시공학회지
    • /
    • 제16권6호
    • /
    • pp.587-594
    • /
    • 2016
  • 본 연구에서는 개발 중인 초음파 기술을 적용한 태양광발전설비 세척 장치의 경제성 분석을 위하여 AHP 편익-비용을 분석하였다. 초음파 기술을 적용한 태양광발전설비 세척장치와 유사한 특성을 가지며, 국내에서 널리 사용되고 있는 태양광발전설비 세척 장치를 비교 대상으로 선정하여 상대적인 편익-비용 분석 값을 비교하였다. 두 비교 대상의 편익, 비용을 정량적, 정성적으로 분석하기 위하여 각각의 측면의 상위계층과 하위평가항목을 도출하고, 하위 평가항목에 대한 평가기준을 도출하였다. 도출된 평가기준을 기반으로 15인의 전문가 인터뷰를 수행함으로써 두 비교 대상의 편익, 비용 가중치를 계산하였다. 분석 결과, 초음파를 사용한 태양광발전설비의 편익-비용 분석 값은 1이상으로 비용대비 이익이 더 높을 것으로 예상되었고, 비교 대상의 편익-비용 분석 값보다 약 1.6배 높았다. 이는 경제적인 측면에서 초음파를 적용한 태양광발전설비 세척 장치의 개발 가치가 있다는 것은 의미한다.

근전도, 초음파와 DITI를 이용한 전기자극의 성인여성 복부비만 개선 효과 관찰 (The Effects of Functional Electrical Stimulation on Abdominal Obesity Improvement of Adult Women by EMG, Ultrasound and DITI)

  • 이현주;태기식
    • 한국정밀공학회지
    • /
    • 제31권11호
    • /
    • pp.1051-1058
    • /
    • 2014
  • In this study, we investigated the improvement effect of obesity by treatment with a developed low frequency electrical stimulation system. Thirty female in their 20's as an experiment subjects divided 3 groups(control, commercialized device, developed device) were treated with electrical stimulation on abdomen for 4 weeks. The body weight, body mass index(BMI), waist-hip ratio(WHR), muscle strength, muscle(transverse abdominis(TrA), internal obliquus abdominis(IO), external obliquus abdominis(EO)), fat thickness and abdominal surface temperature were measured by electromyogram(EMG), ultrasound and digital infrared thermal image(DITI). In the result, the body weight and BMI were decreased. Subcutaneous abdominal fat were significantly reduced after 4 weeks. The muscle strength and TrA muscle thickness was increased 13.2%(p<0.05), and 35.5%, respectively. The fat thickness showed decrease in abdomen (p<0.05). Infrared measurement on abdominal surface temperature as a parameter of improvement in blood circulation was significantly increased(p<0.05). Therefore, the low frequency stimulation showed positive effects on parameters of the obesity improvement.

인공지능을 활용한 초음파영상진단장치에서 초음파 팬텀 영상을 이용한 정도관리의 정량적 평가방법 연구 (A Study on the Quantitative Evaluation Method of Quality Control using Ultrasound Phantom in Ultrasound Imaging System based on Artificial Intelligence)

  • 임연진;황호성;김동현;김호철
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권6호
    • /
    • pp.390-398
    • /
    • 2022
  • Ultrasound examination using ultrasound equipment is an ultrasound device that images human organs using sound waves and is used in various areas such as diagnosis, follow-up, and treatment of diseases. However, if the quality of ultrasound equipment is not guaranteed, the possibility of misdiagnosis increases, and the diagnosis rate decreases. Accordingly, The Korean Society of Radiology and Korea society of Ultrasound in Medicine presented guidelines for quality management of ultrasound equipment using ATS-539 phantom. The DenseNet201 classification algorithm shows 99.25% accuracy and 5.17% loss in the Dead Zone, 97.52% loss in Axial/Lateral Resolution, 96.98% accuracy and 20.64% loss in Sensitivity, 93.44% accuracy and 22.07% loss in the Gray scale and Dynamic Range. As a result, it is the best and is judged to be an algorithm that can be used for quantitative evaluation. Through this study, it can be seen that if quantitative evaluation using artificial intelligence is conducted in the qualitative evaluation item of ultrasonic equipment, the reliability of ultrasonic equipment can be increased with high accuracy.

Piezoelectric Ultrasound MEMS Transducers for Fingerprint Recognition

  • Jung, Soo Young;Park, Jin Soo;Kim, Min-Seok;Jang, Ho Won;Lee, Byung Chul;Baek, Seung-Hyub
    • 센서학회지
    • /
    • 제31권5호
    • /
    • pp.286-292
    • /
    • 2022
  • As mobile electronics become smarter, higher-level security systems are necessary to protect private information and property from hackers. For this, biometric authentication systems have been widely studied, where the recognition of unique biological traits of an individual, such as the face, iris, fingerprint, and voice, is required to operate the device. Among them, ultrasound fingerprint imaging technology using piezoelectric materials is one of the most promising approaches adopted by Samsung Galaxy smartphones. In this review, we summarize the recent progress on piezoelectric ultrasound micro-electro-mechanical systems (MEMS) transducers with various piezoelectric materials and provide insights to achieve the highest-level biometric authentication system for mobile electronics.

의료용 초음파 B-모드 영상을 위한 신호처리 (Signal Processing in Medical Ultrasound B-mode Imaging)

  • 송태경
    • 비파괴검사학회지
    • /
    • 제20권6호
    • /
    • pp.521-537
    • /
    • 2000
  • 초음파 영상은 의료진단을 위한 영상기기 중 가장 널리 쓰이고 있는 방법으로 전자공학에 있어서 DSP 및 VLSI 분야의 기술발전에 힘입어 보다 효율적이고 복잡한 기법들의 적용이 가능하여져 90년대에 이르러 시스템의 성능이 매우 빠르게 발달되었다. 본 논문은 의료진단용 초음파 영상장치에서 사용되는 주요 디지털 신호처리 기법과 시스템 구현 기술에 대하여 기술하였다. 구체적으로는 일반적인 초음파 영상장치의 구조 및 신호처리 기법을 소개하고, 90년대에 개발된 디지털 초음파 영상장치의 기술적인 내용을 그 기술 동향과 전망과 함께 다루었다. 특히 초음파 영상의 화질을 결정하는 가장 중요한 요소인 해상도를 증대하기 위한 모든 초음파 집속 기법을 표현할 수 있는 통합 합성 구경 모형을 제시하고, 이론적인 해석을 통하여 초음파 영상을 위한 어레이 신호처리 기법들을 구분하고 각 방법들에 대한 특성을 조사하였나. 본 논문에서 소개된 신호처리 기법들은 초음파를 이용한 비파괴 검사 분야에 유용하게 적용될 수 있는 것 들이다.

  • PDF

혈류 진단을 위하여 직렬데이터 처리를 하는 다중(128) 채널 초음파 펄스 도플러 시스템에 관한 연구 (A Study on a Multichannel(128) Ultrasound Pulsed Doppler System with Serial Data Processing for Sensing the Blood Flow)

  • Kim, Young-Kil
    • 대한전자공학회논문지
    • /
    • 제23권3호
    • /
    • pp.389-396
    • /
    • 1986
  • A pulsed ultrasonic doppler flowmeter for mesurements of velocity profils in man is described. The device projects a beam of ultrasound in burst of 570 ns duration at 3.5 MHz. The back-scattered signals are processed to produce a signal oxrresponding to the mean velocity over a small region of the flowing stream. The observation range of 112mm is divided into 128 depth channels. The size of this sample volume determines the flowmeter sensitivity and accuracy. The device uses a quadrature detector to detect the direction of the moving target(hemoglobin). The main feature of the novel instrumnet is its simple hardware structure due to sequential signal processing.

  • PDF