• Title/Summary/Keyword: Ultrasound Scanning

Search Result 101, Processing Time 0.029 seconds

Evaluation of Dose and Position Compensation of Parotid Gland Using CT On-rail System in Head-and-Neck Cancer (두경부 암환자 치료 시 CT On-rail System을 이용한 이하선의 위치 보정 및 선량 평가)

  • Jang, Hyeong-Jun;Im, Chung-Geun;Chun, Geum-Sung;Jeong, Il-Seon;Kim, Hoi-Nam
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • Purpose: The checking method of target and normal structure are used by MVCBCT, KVCBCT, CT On-rail System, Ultrasound in H&N cancer patient. In case of MVCT, the utilization of bone structure is valuable to check around tissue. But the utilization of soft tissue is not enough. The point of this paper is dose variation in movable parotid and changeable volume of H&N cancer patient of CT On-rail System. Materials and Methods: The object of H&N cancer patient is 5 in this hospital. The selected patient are scanned ARTISTE CT Vision (CT On-ral System) a triweekly. After CT scanning, tranfered coordinates are obtained by movable of parotid gland comparison with planning image. Checking for the changeable volume of parotid gland. A Obtained CT image are tranfered to the RTP System. So dose variation are checked by following changed volume. Results: The changes of target coordinate by the parotid gland movement are X: -0.4~0.4 cm, Y: -0.4~0.3 cm, Z: -0.3~0.3 cm. the volume of GTV is decreased to about 7.11%/week and then both parotid gland volume are shrinked about 4.81%/week (Lt), 2.91%/week (Rt). At the same time, each parotid gland are diminished in radiation dose as 3.66%/week (Lt), 2.01%/week. Conclusion: Images from CT on the rail System which are able to aquire the better quality images of soft tissue in Target area than MVCBCT. After replanning and dose redistribution by required images, It could gain not only the correction of the patient set-tup errors but exact dose distribution. Accordingly, the delivery of compensated dose, It makes that we could do Adaptive Targeting Radiotherapy and need Real Time Adaptive Targeting Radiotherapy by reduce beam delivary time.

  • PDF

Effects of Body Condition Score and Estimation of Growth Curves for Chest Girth and Ultra Sonic Longissimus Muscle Area, Backfat Thickness and Marbling Scores in Hanwoo(Korean cattle) Cows (한우 암소의 흉위, 초음파 측정 배장근단면적, 등지방두께, 근내지방도에 대한 발육곡선 추정 및 신체충실지수 효과)

  • Lee, Deuk-Hwan;Lee, Gil-Hwan;Cho, Chung-Il;Kim, Nae-Soo
    • Journal of Animal Science and Technology
    • /
    • v.50 no.5
    • /
    • pp.581-590
    • /
    • 2008
  • Growth curves for ultrasonic carcass traits such as longissimus muscle area, backfat thickness and marbling score as well as chest girth which was simultaneously measured when carcass traits were investigated using ultrasound measuring technique were estimated to identify growth patterns and to adjust maturing effects in order to evaluating genetic merits on cows in farming basis. 27,410 records from 22,451 cows on which of 15~90 month of age were investigated from the national wide of Korea using by ultrasonic scanning techniques by the skilled persons from 2002 to 2007. Van Bertalanffy growth function was applied for estimating growth curves on these traits. Carcass traits and chest girth would be linearly increased by body condition score. It might be used for multiplicative correction factors for pre- adjustment on the body condition scores. Growth pattern on chest girth would be quickly reached to mature size and stable on after reached to asymptotic mature size. Longissimus muscle area would also be reached to mature size but little smoother than chest girth. Otherwise, growth curve on backfat thickness would be steadily increasing up to 7 years of age. It also showed large individual difference by way of mean square error. Marbling score would be steadily increased but sharper than those on backfat thickness. It would be reached to mature size up at 5 years of age. Those growth curves would be used for correcting function on age at investigating on genetic evaluation system.

Effects of Lumbar Stabilization Exercise using PNF Techniques on Thickness of Lumbar Deep Muscle and Functional Activity in Chronic Low Back Pain Patients (만성요통환자에서 PNF 기법을 이용한 요부안정화 운동이 요부 심부근 두께 및 기능적 활동에 미치는 효과)

  • Kim, Gi-Do;Lee, Yun-Jung;Choi, Wan-Suk;Lee, Dong-Woo;Jung, Dae-In;Kim, Kyung-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.3
    • /
    • pp.233-243
    • /
    • 2012
  • The purpose of this study was to examine the effects of lumbar stabilization exercise using the PNF techniques on the lumbar deep muscles thickness and functional activity in chronic low back pain patient. Group I(n=10): general physical therapy group; Group II(n=10): general lumbar stabilization exercise group; Group III(n=10): lumbar stabilization exercise using PNF techniques(stabilizing reversal, rhythmic stabilization, combination of isotonic) group. Change of pain was measured with visual analog scale(VAS). To observe muscle thickness changes, we measured transverse abdominis(TrA), external oblique(EO), multifidus with real time ultrasound scanning. The functional activity were measured with Oswestry Disability Questionnaire(ODQ) and Roland & Morris Disability Questionnaire(RMDQ). In VAS test, group III had more significantly decreased than before exercise. In muscle thickness test, group III had more significantly increased than before exercise in right/left TrA, EO, multifidus. In ODQ & RMDQ test, group III had more significantly decreased than before exercise. This study show that the PNF techniques is effective in improving the lumbar stability and functional activity in chronic low back pain patients.

Implementation of a Library Function of Scanning RSSI and Indoor Positioning Modules (RSSI 판독 라이브러리 함수 및 옥내 측위 모듈 구현)

  • Yim, Jae-Geol;Jeong, Seung-Hwan;Shim, Kyu-Bark
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.11
    • /
    • pp.1483-1495
    • /
    • 2007
  • Thanks to IEEE 802.11 technique, accessing Internet through a wireless LAN(Local Area Network) is possible in the most of the places including university campuses, shopping malls, offices, hospitals, stations, and so on. Most of the APs(access points) for wireless LAN are supporting 2.4 GHz band 802.11b and 802.11g protocols. This paper is introducing a C# library function which can be used to read RSSIs(Received Signal Strength Indicator) from APs. An LBS(Location Based Service) estimates the current location of the user and provides useful user's location-based services such as navigation, points of interest, and so on. Therefore, indoor, LBS is very desirable. However, an indoor LBS cannot be realized unless indoor position ing is possible. For indoor positioning, techniques of using infrared, ultrasound, signal strength of UDP packet have been proposed. One of the disadvantages of these techniques is that they require special equipments dedicated for positioning. On the other hand, wireless LAN-based indoor positioning does not require any special equipments and more economical. A wireless LAN-based positioning cannot be realized without reading RSSIs from APs. Therefore, our C# library function will be widely used in the field of indoor positioning. In addition to providing a C# library function of reading RSSI, this paper introduces implementation of indoor positioning modules making use of the library function. The methods used in the implementation are K-NN(K Nearest Neighbors), Bayesian and trilateration. K-NN and Bayesian are kind of fingerprinting method. A fingerprint method consists of off-line phase and realtime phase. The process time of realtime phase must be fast. This paper proposes a decision tree method in order to improve the process time of realtime phase. Experimental results of comparing performances of these methods are also discussed.

  • PDF

Position Control Technique of Ultrasonic Scanner for an Automated Ultrasonic Testing Using Surface Wave (표면파를 이용한 자동 초음파탐상검사 주사장치의 위치제어 기술)

  • Lee, Jong-Po;Park, Chul-Hoon;Um, Byong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.30-37
    • /
    • 2003
  • In order to replace the manual ultrasonic testing(UT) with an automated UT(AUT), a scanner which enables us to control the positions of a transducer is essential. Encoders have been commonly used to obtain the position information from the conventional scanners controlled by motor. Encoders have various advantages in many aspects. However, if the slip of motor wheel occurs during scanning, various errors are involved in the position accuracy. Thus, the position information of encoders becomes meaningless in case of slip. The reliability of AUT results nay become serious problem. Hence, slip must be avoided, but it can not be completely avoided at present time. In this paper, a new idea that surface wave is used to solve this problem and replace encoders has been proposed. It is shown that this idea can be employed in AUT scanner without encoders. That is, one transducer transmitting surface wave is fixed and the other transducer attached to the scanner receives UT signal. Then, computer calculates the present position of scanner based on the information given by surface wave. Thus, the movement of a scanner can be controlled by the amount of input based on the information obtained.

Finite Element Simulation of Laser-Generated Ultrasound and Interaction with Surface Breaking Cracks (유한요소법을 이용한 레이저 유도 초음파와 표면 균열과의 상호작용 모델링)

  • Jeong, Hyun-Jo;Park, Moon-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • A finite element method is used to simulate interaction of laser-based ultrasounds with surface breaking tracks in elastic media. The laser line source focused on the surface of semi-infinite medium is modeled as a shear dipole in 2-D plane strain finite elements. The shear dipole-finite clement model is found to give correct directivity patterns for generated longitudinal and shear waves. The interaction of surface waves with surface breaking cracks (2-D machined slot) is considered in two ways. Both the source and receiver are fixed with respect to the cracks in the first case, while the source is moving in another case. It is shown that the crack depth tested in the range of 0.3-5.0mm $({\lambda}_R/d=0.21{\sim}3.45)$ can be measured using the corner reflected waves produced by the fixed laser source. The moving laser source is found to cause a large amplitude change of reflected waves near crack, and the crack whose depth is one order lower than the wavelength ran be detected from this change.

Location Studies of Prostate Volume Measurement by using Transrectal Ultrasonography: Experimental Study by Self-Produced Prostate Phantom (경직장초음파를 이용한 전립선 볼륨측정 시의 위치 연구: 전립선모형 제작과 실험)

  • Kim, Yun-Min;Yoon, Joon;Byeon, II-kyun;Lee, Hoo-Min;Kim, Hyeong- Gyun
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.437-442
    • /
    • 2015
  • Accurate volume measurement of the prostate is a significant role in determining the result of diagnosis and treatment of benign prostate hyperplasia. The purpose of this study was to determine, when measuring prostate volume by TRUS, whether location is more accurately determined by transaxial or longitudinal scanning. With reference to the patient's image, it was produced six prostate model. It compares the actual volume and the measurement volume, and find the optimal measurement position of each specific model. Prostate volume measured by TRUS closely correlates with prostate phantom volume. There was no significant difference(p = .156). To measure the accurate volume of prostate with focal protrusion, its length should be measured exclude the protrusions.

Efficiency of Equilume light mask on the resumption of early estrous cyclicity and ovulation in Thoroughbred mares

  • Kim, Seongmin;Jung, Heejun;Murphy, Barbara Anne;Yoon, Minjung
    • Journal of Animal Science and Technology
    • /
    • v.64 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Equilume light masks had no impact on hastening the resumption of estrous cyclicity in mares maintained in outdoor pastures on the mainland of Korea due to the cold weather conditions. Jeju Island is a major horse-breeding site in Korea and is warmer than the mainland during the winter season. Therefore, the primary objective of this study was to explore the efficiency of the Equilume light mask on the resumption of seasonal estrous cycles in Thoroughbred mares on Jeju Island. A total of 20 nonpregnant mares were randomly divided into the Equilume light mask (n = 9) and stable lighting (n =11) groups. The experiment was performed at seven different horse-breeding farms located on Jeju Island from November 15, 2020, to February 15, 2021. The mares were exposed to the respective lights from 16:00 to 23:00. Follicle size and uterine edema were measured by ultrasound scanning. Body condition scores (BCS) were also monitored during the experiment. Statistical analysis was conducted using the SAS and SPSS software, and p-values of < 0.05 were considered statistically significant. Two of the nine (22.2%) mares in the Equilume light mask group and three of the 11 (27.28%) mares in the stable lighting group were still cycling in December and January, which were considered as all-year-round cycling mares. On February 15, there was no difference between groups in the resumption of early seasonal estrus cycle, which was determined by follicles > 25 mm in addition to uterine edema. All mares in the Equilume light mask group and five of the eight mares (62.5%) in the stable lighting group had resumed cycling. Interestingly, six of the seven mares (87.5%) in the Equilume light mask and four of eight mares (50%) in the stable lighting group had already ovulated on February 15 (p > 0.05), as determined by the presence of a recent corpus luteum. No difference was observed in BCS and uterine edema between groups (p > 0.05). In conclusion, the Equilume light mask can be an effective approach to induce early seasonal estrus cycles of mares in Jeju Island, and it also enhances the efficiency of farm management by reducing labor.

The Role of Chest CT Scans in the Management of Empyema (농흉에서 전산화 단층촬영의 의의)

  • Heo, Jeong-Suk;Kwun, Oh-Yong;Sohn, Jeong-Ho;Choi, Won-Il;Hwang, Jae-Seok;Han, Seung-Beom;Jeon, Young-June;Kim, Jung-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.4
    • /
    • pp.397-404
    • /
    • 1994
  • Background: To decide the optimal antibiotics and application of chest tube, examination of pleural fluid is fundamental in the management of empyema. Some criteria for drainage of pleural fluid have been recommended but some controversies have been suggested. Recently, newer radiologic methods including ultrasound and computed tomography scanning, have been applied to the diagnosis and management of pleural effusions. We undertook a retrospective analysis of 30 patients with pleural effusion who had CT scans of the chest in order to apply the criteria of Light et al retrospectively to patients with loculation and to correlate the radiologic appearance of pleural effusions with pleural fluid chemistry. Method: We analyzed the records of 30 out of 147 patients with pleural effusion undergoing chest CT scans. Results: 1) Six of the pleural fluid cultures yielded gram negative organisms and three anaerobic bacterias and one Staphylococcus aureus and one non-hemolytic Streptococci. No organism was cultured in ninteen cases(63.0%). 2) The reasons for taking chest CT scans were to rule out malignancy or parenchymal lung disease(46.7%), poor response to antibiotics(40.0%), hard to aspirate pleural fluid(10.0%) and to decide the site for chest tube insertion(3.3%). 3) There was no significant correlations between ATS stages and loculation but there was a tendency to loculate in stage III. 4) There was a significant inverse relationship between the level of pH and loculation(p<0.05) but there appeared to be no relationship between pleural fluid, LDH, glucose, protein, loculation and pleural thickening. 5) In 12 out of 30, therapeutic measures were changed according to the chest CT scan findings. Conclusion: We were unable to identify any correlations between the plerual fluid chemistry, ATS stages and loculations except pH, and we suggest that tube thoracotomy should be individualized according to the clinical judgement and serial observation. All patients with empyema do not need a chest CT scan but a CT scan can provide determination of loculation, guiding and assessing therapy which should decrease morbidity and hospital stay.

  • PDF

Factors Affecting Pregnancy Rates on Transfer of Pronuclear Microinjected Embryos in Korean Black Goats (전핵 미세 주입법으로 생산된 한국흑염소 수정란의 이식 조건이 수태율에 미치는 영향)

  • Choi, Y.S.;Shin, H.G.;Jang, S.K.;Yang, H.S.;Lee, O.K.;Lee, D.S.;Cho, J.K.;Shin, S.T.
    • Journal of Embryo Transfer
    • /
    • v.22 no.1
    • /
    • pp.53-61
    • /
    • 2007
  • This study was investigated factors affecting the pregnancy rates after transfer of pronuclear microinjected embryos for the production of transgenic Korean black goats. Embryo transfer was carried out in 343 recipient Korean black goats from September 1999 to June 2000. Estrus was induced by the insertion of intravaginal progesterone devices $CIDR^(R)$ for 2 weeks. A single injection of 400 IU equine chorionic gonadotropin was administered at 48h before $CIDR^(R)$ removal to increase the proportion of does cycling and ovulation rate. Good quality embryos were prepared by microinjection of DNA into the pronuclei of fertilized goat oocyte and cultured in vitro. Pronuclear microinjected $1{\sim}8$ cell stage embryos were surgically transferred into the oviducts of the recipient at day 4 or 5 following $CIDR^(R)$ removal, and morula to blastocyst stage embryos were surgically transferred into uterus at day 9. Pregnancy was diagnosed by transrectal ultrasound scanning at $20{\sim}30d$ and 8 weeks following embryo transfer. The pregnancy rate was affected by several factors, such as estrus induction, the number of previous transfer, transfer site, stage of CL (corpus luteum), the number of recipient CL, stage of embryos and the number of transferred embryo. The pregnancy rate was significantly higher in recipients that came into estrus naturally than recipients that induced to come into estrus with $CIDR^(R)$(59.1% vs. 36.8%; P<0.05). The pregnancy rate was higher when the embryos were transferred into the left oviduct than transferred into the right oviduct (42.9% vs. 35.3%; P<0.05). The pregnancy rate of recipients with $CH_1$ (early) stage corpus hemorrhagicum in ovary was hi틴or than recipient with $CH_3$ (late) stage hemorrhagicum (47.5% vs. 17.9%; P<0.01). Higher pregnancy rates were obtained by transfer of 1-cell stage embryos into oviduct while late blastocysts (51.6% vs. 66.7%; P<0.01) into uterus. The pregnancy rates when 3 embryos were transferred to recipients were significantly higher than when 2 embryos we.e transferred (47.6% vs. 27.0%; P<0.05). Although there were no significant difference among the group, adhesion of reproductive organs, uterine size, ovulation rate of recipients, presence of large follicle and difficulty of transfer affected pregnancy rate of recipient. Higher pregnancy rates were obtained in the recipients with $8{\sim}15m$ diameter uterine horn as compared to the recipients with <5m diameter or >20mm diameter uterine hem (38.9%, 20% vs. 18.2%), in the recipients with large follicle in the ovulated ovary ipsilaterally (53.6% vs. 37.1%) and in the transfer which was carried out easily (39.2% vs. 27.8%, 0%). In conclusion, the high rate of pregnancy was achieved following transfer of pronuclear microinjected embryos when three or four 1-cell stage embryos were transferred into oviduct with $CH_1$ stage corpus hemorrhagicum in the ovary of recipient which came into estrus naturally.