• Title/Summary/Keyword: Ultrasound Needle

Search Result 143, Processing Time 0.054 seconds

Effects of Pain Release and Power Grip after Apply Needle TENS, Ultrasound, Taping to Carpal Tunnel Syndrom Patients (수근관 증후군의 Needle TENS, 초음파, 테이핑이 통증감소와 악력에 미치는 효과)

  • Han, Jong-Man;Gong, Won-Tae
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.1 no.1
    • /
    • pp.49-57
    • /
    • 2006
  • Purpose : The Purpose of this study was to pain release and power grip in wrist affect of needle TENS(utilized of TENS in electrotherapy with oriental needle) and ultrasound therapy and taping with carpal tunnel syndrome patients. Methods : To study divided of each groups. each groups were apply to ultrasound therapy for 5 mintus, Taping was attached from wrist joint to elbow joint medial epicondly after maximum extension. needle TENS application was following of median nerve in wrist. Result : 1. The pain was released on needle TENS, ultrasound and taping groups of all(p<.05). 2. Power grip was enhanced in needle TENS and taping groups(p<.05) but ultrasound was no difference compared with before therapy. 3. Compared with needle TENS and taping therapy about pain release was needle TENS groups better than ultrasound groups(p<.05) Conclusion : Needle TENS, taping therapy are more effectable than ultrasound therapy for grip power and pain release. Needle TENS therapy is more effectable than taping therapy for pain release. Therefor, neddle TENS therapy is most effectable for pain release with carpal tunnel syndrome patients.

  • PDF

A Study on the Reflectivity according to the Material of Biopsy Gun Needle Used in Ultrasound Biopsy (초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구)

  • Hoon Kim;Cheong-Hwan Lim
    • Journal of radiological science and technology
    • /
    • v.47 no.2
    • /
    • pp.97-105
    • /
    • 2024
  • The examination needle used in ultrasound biopsy is a medical device used to determine whether there is an abnormality in the tissue. Typically, stainless steel is the standard material used for such needles; however, this study wanted to identify a material that could better enhance sound compared to traditional stainless steel. In this study, six types of needle materials available with the biopsy gun were inserted into pork and ultrasound images according to the curved probe and linear probe were evaluated using ultrasound equipment. The findings revealed significant improvements in ultrasound acoustic enhancement with alternative materials compared to stainless steel (p<0.05). The results regarding the depth of each ultrasound image using the curved probe showed that tungsten and brass had high sound enhancement(p<0.05), while with the linear probe, sound enhancement was high in brass, pla, aluminum, and copper(p<0.05). Due to these results, the previously used stainless needle showed lower ultrasound acoustic enhancement than the five types of materials being compared. Consequently, the outcomes of this study provide valuable insights for the development of new needle technologies aimed at minimizing patient risks and improving diagnostic accuracy.

The Success Rate of Caudal Block Under Ultrasound Guidance and the Direction of the Needle in the Sacral Canal (초음파 영상의 유도를 이용한 미추경막외블록의 성공률과 천골관 내에서의 바늘의 방향)

  • Roh, Jang Ho;Kim, Won Oak;Yoon, Kyung Bong;Yoon, Duck Mi
    • The Korean Journal of Pain
    • /
    • v.20 no.1
    • /
    • pp.40-45
    • /
    • 2007
  • Background: Caudal block is useful when anesthesia for surgery or treatment for chronic pain is needed, but this procedure has a failure rate of up to 25% even when it performed byan experienced physician. This high failure rate is usually due to improper needle placement. Methods: After gaining approval of the ethics committee, 46 patients received caudal blocks under ultrasound guidance; these were performed after the anatomical structures in the sacral hiatus had been measured with ultrasound. All these procedures were performed by the same anesthesiologist. The position and direction of the needle were identified using fluoroscopy by injecting a radio-opaque contrast through the needle. The time taken from thelidocaine injection to verification of the needle was measured and the planned nerve block was then carried out. Results: All cases of needle insertion into the sacral canal under ultrasound guidance were successful. The average duration of the procedure and the trial count were $134.1{\pm}10.1seconds$ and $1.2{\pm}0.1$, respectively. In 12 of the 46 cases (26%), the needle deviated either left or right in the sacral canal, so the direction of the needle had to be adjusted. The distance between two cornua, the depth of the sacral hiatus and the thickness and length of the sacrococcygeal ligament were $17.1{\pm}0.4$, $3.9{\pm}0.3$, $2.3{\pm}0.1$ and $24.9{\pm}0.9mm$, respectively. Conclusions: Ultrasound guidance can increase the success rate of inserting a needle into the sacral canal. However, even when ultrasound is used, the needle can deviate either left or right in the sacral canal.

Usefulness of X-ray Guided Biopsy and Ultrasound Guided Biopsy in Breast Microcalcification Biopsy (유방 미세석회화 조직검사에서 X선 유도 하 조직검사와 초음파 유도 하 조직검사의 유용성)

  • Choi, Miseon;Song, Jongnam
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.201-206
    • /
    • 2016
  • Social interest in breast cancer has increased. The most basic exams for diagnosis include breast X-ray and breast ultrasound. In particular, breast microcalcification requires histological diagnosis, and breast microcalcification biopsy is commonly performed. Therefore, this study aimed to analyze and assess X-ray guided biopsy (needle localized open biopsy) and ultrasound guided biopsy (sono guided core needle biopsy), which are basics in diagnosis of microcalcification. Targeting 241 cases in which magnification mammography was performed for patients who visited the hospital due to breast microcalcification, age distribution and the location of lesions were analyzed in X-ray guided biopsy and ultrasound guided biopsy. By classifying exams performed after magnification mammography, the frequencies of X-ray guided biopsy and ultrasound guided biopsy were analyzed, and malignant and benign results were confirmed. The results showed that 64 cases(26.6%) were X-ray guided biopsy, which was 5.4 times higher than 12 cases(4.9%) of ultrasound guided biopsy. Due to development of ultrasound equipments, stereotactic vacuum-assisted biopsy, etc. the methods of histological diagnosis of microcalcification have become diverse, but when considering characteristics and limitations of each exam, X-ray guided biopsy is thought to be most accurate and useful.

Clinical Application of Ultrasound-Guided Thyroid Fine Needle Aspiration Biopsy and Thinprep Cytology Test in Diagnosis of Thyroid Disease

  • Wei, Ying;Lu, Yao;Li, Chenxi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.10
    • /
    • pp.4689-4692
    • /
    • 2016
  • Purpose: To study the clinical application value of ultrasound guided thyroid fine needle aspiration biopsy and thinprep cytology testing in diagnosis of thyroid disease. Methods: A total of 78 patients with thyroid nodules were enrolled, 34 males and 44 females, aged 33-64 years old with mean age of 47.6 years. All underwent thyroid module fine needle puncture after surgery to assess cell pathology and histopathological features. Results: Sufficient specimens were obtained from all of 78 patients, the cytological results of 73 cases (93.6 %) being consistent with pathological results. While 20 cases (25.6 %) were malignant tumors, 44 (56.4 %) were benign and 9 (11.5 %) were non-tumor lesions. The sensitivity of benign and malignant thyroid nodule by thyroid fine needle puncture was 90.9 %, specificity was 98.1 % and the positive predictive value was 96.3 %. Conclusions: It is demonstrated that ultrasound-guided thyroid fine needle aspiration biopsy and thinprep cytology testing have diagnostic value in clinical application for thyroid disease,showing good diagnostic coincidence rates with histopathological examination. They can thus be regarded as safe and effective for preoperative diagnosis and providing an appropriate basis for selection of surgery.

Ultrasound Phantoms to Protect Patients from Novices

  • Kim, Young Hoon
    • The Korean Journal of Pain
    • /
    • v.29 no.2
    • /
    • pp.73-77
    • /
    • 2016
  • With the growing use of ultrasound for pain management, we are interested in how to teach and practice ultrasound-guided procedures. Ethically, we should not insert a needle in a patient until after much practice on a phantom. Several types of phantoms have been introduced for ultrasound training, including water, agar/gelatin, elastomeric rubber, and meat phantoms and cadavers. The ideal phantom is similar to human tissue, is readily available and inexpensive, can be used repeatedly, provides tactile feedback, will hold a needle in place, does not generate needle tracks, and is not a health hazard. Several studies have shown the effectiveness of phantoms for improving the proficiency of novices. We hope that the application of phantoms in education leads to improved proficiency and increased patient safety.

Development and Evaluation of D-Attention Unet Model Using 3D and Continuous Visual Context for Needle Detection in Continuous Ultrasound Images (연속 초음파영상에서의 바늘 검출을 위한 3D와 연속 영상문맥을 활용한 D-Attention Unet 모델 개발 및 평가)

  • Lee, So Hee;Kim, Jong Un;Lee, Su Yeol;Ryu, Jeong Won;Choi, Dong Hyuk;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.195-202
    • /
    • 2020
  • Needle detection in ultrasound images is sometimes difficult due to obstruction of fat tissues. Accurate needle detection using continuous ultrasound (CUS) images is a vital stage of treatment planning for tissue biopsy and brachytherapy. The main goal of the study is classified into two categories. First, new detection model, i.e. D-Attention Unet, is developed by combining the context information of 3D medical data and CUS images. Second, the D-Attention Unet model was compared with other models to verify its usefulness for needle detection in continuous ultrasound images. The continuous needle images taken with ultrasonic waves were converted into still images for dataset to evaluate the performance of the D-Attention Unet. The dataset was used for training and testing. Based on the results, the proposed D-Attention Unet model showed the better performance than other 3 models (Unet, D-Unet and Attention Unet), with Dice Similarity Coefficient (DSC), Recall and Precision at 71.9%, 70.6% and 73.7%, respectively. In conclusion, the D-Attention Unet model provides accurate needle detection for US-guided biopsy or brachytherapy, facilitating the clinical workflow. Especially, this kind of research is enthusiastically being performed on how to add image processing techniques to learning techniques. Thus, the proposed method is applied in this manner, it will be more effective technique than before.

Diagnostic Approach of Hepatic Mass using Ultrasound Guided Fine Needle Aspiration in a Dog (개에서 초음파를 이용한 간 종괴의 세침흡인술 증례)

  • 최호정;이기창;최민철;윤정희
    • Journal of Veterinary Clinics
    • /
    • v.21 no.2
    • /
    • pp.181-183
    • /
    • 2004
  • Hepatic mass was aspirated under the guidance with ultrasound in 9-year old female maltese with signs of anorexia, hematochezia, vomiting, depression, and abdominal distension. Radiographic and abdominal ultrasonographic examinations were performed, which revealed enlarged tubular shaped uterine mass and solitary, small round hyperechoic hepatic mass dorsal to gall bladder as an incidental finding. Ultrasound-guided fine needle aspiration was completed, but histologic confirmation should be made for definitive diagnosis by tissue core or wedge biopsy.

Technical Aspects of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

  • Kang, Hyo Jae;Hwangbo, Bin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.75 no.4
    • /
    • pp.135-139
    • /
    • 2013
  • Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is becoming a standard method for invasive mediastinal staging and for the diagnosis of paratracheal and peribronchial lesions. It is essential to understand the technical aspects of EBUS-TBNA to ensure safe and efficient procedures. In this review, we discuss the practical aspects to be considered during EBUS-TBNA, including anesthesia, manipulation of equipment, understanding mediastinal ultrasound images, target selection, number of aspirations needed per target, sample handling, and complications.

Ultrasound-guided Needle Aspiration of Cranial Epidural Hematoma in a Neonate

  • Lee, Dong-Hoon;Lee, Sang-Weon;Lee, Tae-Hong;Ban, Ji-Eun
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.1
    • /
    • pp.61-63
    • /
    • 2006
  • We report a unique case of a neonate with an epidural hematoma induced by vacuum extraction. The epidural hematoma, communicating with a cephalhematoma through a linear skull fracture, disappeared after ultrasound-guided needle aspiration. The patient quickly recovered and one month later computed tomography revealed a complete resolution of the epidural hematoma.