• Title/Summary/Keyword: Ultrasound Medical Imaging

Search Result 277, Processing Time 0.024 seconds

Concurrent Torsion of the Caudate Liver Lobe and Spleen in a German Shepherd Dog

  • Seong-won An;Seung-Min Hwang;Il-Gwon Jung;Sang-Kwon Lee;Young-Sam Kwon
    • Journal of Veterinary Clinics
    • /
    • v.41 no.1
    • /
    • pp.30-36
    • /
    • 2024
  • A 3-year-old, 20.6 kg, neutered male German Shepherd dog was referred to Kyungpook National University Veterinary Medicine Teaching Hospital. Clinical examination revealed chronic diarrhea for 6 weeks and a non-tender, distended abdomen without lethargy, anorexia, and vomiting. Diarrhea was watery and had a waxing and waning course despite symptomatic treatment. A complete blood count identified mild leukocytosis and mild anemia. Serum biochemistry analysis showed elevated alanine aminotransferase and aspartate aminotransferase levels, and mild hypoalbuminemia. Abdominal ultrasound examination revealed mixed echogenicity with absent blood flow at the caudate process of the caudate liver lobe and a small amount of ascites. Computed tomography revealed torsion of the caudate process of the caudate liver lobe and spleen and gas dilatation of the intestine. After establishing a diagnosis of organ torsion on imaging, we deemed the condition an emergency and immediately performed surgery. Given that laparotomy confirmed organ torsion, liver lobectomy, total splenectomy, and prophylactic gastropexy were conducted. The patient was discharged 11 days after surgery without complications. In general, liver lobe torsion and splenic torsion are uncommon in dogs and present with nonspecific clinical signs, such as abdominal pain, lethargy, anorexia, and vomiting. In the current case, torsion of the caudate liver lobe and spleen occurred without other clinical signs except for a distended abdomen. Moreover, no reports in dogs have demonstrated the simultaneous occurrence of both diseases.

Scoring System to Predict Malignancy for MRI-Detected Lesions in Breast Cancer Patients: Diagnostic Performance and Effect on Second-Look Ultrasonography (유방암 환자의 MRI에서 발견된 병변의 악성 예측을 위한 점수체계: 진단적 능력과 이차 초음파 결정에 미치는 영향)

  • Young Geol Kwon;Ah Young Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.379-394
    • /
    • 2020
  • Purpose To design a scoring system to predict malignancy of additional MRI-detected lesions in breast cancer patients. Materials and Methods Eighty-six lesions (64 benign and 22 malignant) detected on preoperative MRI of 68 breast cancer patients were retrospectively included. The clinico-radiologic features were correlated with the histopathologic results using the Student's t-test, Fisher's exact test, and logistic regression analysis. The scoring system was designed based on the significant predictive features of malignancy, and its diagnostic performance was compared with that of the Breast Imaging-Reporting and Data System (BI-RADS) category. Results Lesion size ≥ 8 mm (p < 0.001), location in the same quadrant as the primary cancer (p = 0.005), delayed plateau kinetics (p = 0.010), T2 isointense (p = 0.034) and hypointense (p = 0.024) signals, and irregular mass shape (p = 0.028) were associated with malignancy. In comparison with the BI-RADS category, the scoring system based on these features with suspicious non-mass internal enhancement increased the diagnostic performance (area under the receiver operating characteristic curve: 0.918 vs. 0.727) and detected three false-negative cases. With this scoring system, 22 second-look ultrasound examinations (22/66, 33.3%) could have been avoided. Conclusion The scoring system based on the lesion size, location relative to the primary cancer, delayed kinetic features, T2 signal intensity, mass shape, and non-mass internal enhancement can provide a more accurate approach to evaluate MRI-detected lesions in breast cancer patients.

Large-Scale Ultrasound Volume Rendering using Bricking (블리킹을 이용한 대용량 초음파 볼륨 데이터 렌더링)

  • Kim, Ju-Hwan;Kwon, Koo-Joo;Shin, Byeong-Seok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.7
    • /
    • pp.117-126
    • /
    • 2008
  • Recent advances in medical imaging technologies have enabled the high-resolution data acquisition. Therefore visualization of such large data set on standard graphics hardware became a popular research theme. Among many visualization techniques, we focused on bricking method which divided the entire volume into smaller bricks and rendered them in order. Since it switches bet\W8n bricks on main memory and bricks on GPU memory on the fly, to achieve better performance, the number of these memory swapping conditions has to be minimized. And, because the original bricking algorithm was designed for regular volume data such as CT and MR, when applying the algorithm to ultrasound volume data which is based on the toroidal coordinate space, it revealed some performance degradation. In some areas near bricks' boundaries, an orthogonal viewing ray intersects the single brick twice, and it consequently makes a single brick memory to be uploaded onto GPU twice in a single frame. To avoid this redundancy, we divided the volume into bricks allowing overlapping between the bricks. In this paper, we suggest the formula to determine an appropriate size of these shared area between the bricks. Using our formula, we could minimize the memory bandwidth. and, at the same time, we could achieve better rendering performance.

  • PDF

Diagnostic Performance of Core Needle Biopsy for Characterizing Thyroidectomy Bed Lesions

  • So Yeong Jeong;Jung Hwan Baek;Sae Rom Chung;Young Jun Choi;Dong Eun Song;Ki-Wook Chung;Won Woong Kim;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.10
    • /
    • pp.1019-1027
    • /
    • 2022
  • Objective: Thyroidectomy bed lesions frequently show suspicious ultrasound (US) features after thyroid surgery. Fine-needle aspiration (FNA) may not provide definitive pathological information about the lesions. Although core-needle biopsy (CNB) has excellent diagnostic performance in characterizing suspicious thyroid nodules, no published studies have evaluated the performance of CNB specifically for thyroidectomy bed lesions. Therefore, we aimed to evaluate the diagnostic performance and safety of CNB for characterizing thyroidectomy bed lesions. Materials and Methods: A total of 124 thyroidectomy bed lesions in 113 patients (79 female and 34 male; age, 23-85 years) who underwent US-guided CNB between December 2008 and December 2020 were included. We reviewed the US imaging features of the target lesions and the histories of previous biopsies. The pathologic results, diagnostic performance for malignancy, and complications of CNB were analyzed. Results: All samples (100%) obtained by CNB were adequate for pathological analysis. Pathological analysis revealed inconclusive results in two lesions (1.6%). According to the reference standard, 50 lesions were ultimately malignant (40.3%), and 72 were benign (58.1%), excluding the two inconclusive lesions. The performance of CNB for diagnosing malignant thyroidectomy bed lesions in the 122 lesions had a sensitivity of 98.0% (49/50), a specificity of 100% (72/72), positive predictive value of 100% (49/49), and negative predictive value of 98.6% (72/73). Eleven lesions were referred for CNB after prior inconclusive FNA results in thyroidectomy bed lesions, for all of which CNB yielded correct conclusive pathologic diagnoses. According to the pathological analysis of CNB, there were various benign lesions (58.9%, 73/124) besides recurrence, including benign postoperative lesions other than suture granuloma (32.3%, 40/124), suture granuloma (15.3%, 19/124), remnant thyroid tissue (5.6%, 7/124), parathyroid lesions (4%, 5/124), and abscesses (1.6%, 2/124). No major or minor complications were associated with the CNB procedure. Conclusion: US-guided CNB is accurate and safe for characterizing thyroidectomy bed lesions.

Clinical Characteristics of False-Positive Lymph Node on Chest CT or PET-CT Confirmed by Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration in Lung Cancer

  • Lee, Jongmin;Kim, Young Kyoon;Seo, Ye Young;Choi, Eun Kyoung;Lee, Dong Soo;Kim, Yeon Sil;Hong, Sook Hee;Kang, Jin Hyoung;Lee, Kyo Young;Park, Jae Kil;Sung, Sook Whan;Kim, Hyun Bin;Park, Mi Sun;Yim, Hyeon Woo;Kim, Seung Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.4
    • /
    • pp.339-346
    • /
    • 2018
  • Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a standard procedure to evaluate suspicious lymph node involvement of lung cancer because computed tomography (CT) and $^{18}F$-fluorodeoxyglucose positron emission tomography-CT (PET-CT) have limitations in their sensitivity and specificity. There are a number of benign causes of false positive lymph node such as anthracosis or anthracofibrosis, pneumoconiosis, old or active tuberculosis, interstitial lung disease, and other infectious conditions including pneumonia. The purpose of this study was to evaluate possible causes of false positive lymph node detected in chest CT or PET-CT. Methods: Two hundred forty-seven patients who were initially diagnosed with lung cancer between May 2009 and December 2012, and underwent EBUS-TBNA to confirm suspicious lymph node involvement by chest CT or PET-CT were analyzed for the study. Results: Of 247 cases, EBUS-TBNA confirmed malignancy in at least one lymph node in 189. The remaining 58 patients whose EBUS-TBNA results were negative were analyzed. Age ${\geq}65$, squamous cell carcinoma as the histologic type, and pneumoconiosis were related with false-positive lymph node involvement on imaging studies such as chest CT and PET-CT. Conclusion: These findings suggest that lung cancer staging should be done more carefully when a patient has clinically benign lymph node characteristics including older age, squamous cell carcinoma, and benign lung conditions.

Survey for Needs of Bio-Signal Devices for the Diagnosis, Assessment, or Analysis of Neurocognitive Disorder in Korean Society of Oriental Neuropsychiatry (인지 장애 진단·평가·분석을 위한 생체신호 장비 개발에 대한 수요조사: 한방신경정신과학회 회원들을 대상으로)

  • Choi, Yujin;Kim, Ji Hye;Kim, Kahye;Kim, Jaeuk
    • Journal of Oriental Neuropsychiatry
    • /
    • v.31 no.2
    • /
    • pp.89-99
    • /
    • 2020
  • Objectives: The purpose of this study was to identify the needs of bio-signal devices for the diagnosis, assessment, and analysis of neurocognitive disorder in Korean medicine (KM) hospitals and clinics. Methods: A questionnaire was developed to survey the current status of medical device use, and diagnosis and interventions for patients with cognitive disorders in KM hospitals and clinics. November 11~December 2, 2019, 114 responses (71.9% completed) were collected by internet-based questionnaires from the members of the Korean society of Oriental Neuropsychiatry. Results: The clinical requests were in the descending order of hematology analyzer, ultrasound imaging system, and electroencephalography among the 15 most commonly used devices of which research would support for their clinical usability. The biosignal-based devices showed the highest research demands for patients with mild cognitive impairment rather than more severe stages of cognitive impairment. Prevention rather than diagnosis, or several treatment regimens was the strongest clinical area of the KM for patients with neurodegenerative cognitive impairment. Many responded that five to 10 minutes of test duration and 20,000 won to 30,000 won of cost would be appropriated for a new device to be developed. Conclusions: There were strong demands for the development of bio-signal devices for neurocognitive disorders among the KM doctors. Specifically, it showed high needs for the technology that can be used in the prevention area of cognitive disorders. Additionally, new medical devices to assess cognitive functions and to obtain KM pattern-related information were the high needs.

Clinical Practice Guidelines for Gastric Cancer in Korea: An Evidence-Based Approach

  • Lee, Jun Haeng;Kim, Jae G.;Jung, Hye-Kyung;Kim, Jung Hoon;Jeong, Woo Kyoung;Jeon, Tae Joo;Kim, Joon Mee;Kim, Young Il;Ryu, Keun Won;Kong, Seong-Ho;Kim, Hyoung-Il;Jung, Hwoon-Yong;Kim, Yong Sik;Zang, Dae Young;Cho, Jae Yong;Park, Joon Oh;Lim, Do Hoon;Jung, Eun Sun;Ahn, Hyeong Sik;Kim, Hyun Jung
    • Journal of Gastric Cancer
    • /
    • v.14 no.2
    • /
    • pp.87-104
    • /
    • 2014
  • Although gastric cancer is quite common in Korea, the treatment outcome is relatively favorable compared to those in western countries. However, there are currently no Korean multidisciplinary guidelines for gastric cancer. Experts from related societies developed guidelines de novo to meet Korean circumstances and requirements, including 23 recommendation statements for diagnosis (n=9) and treatment (n=14) based on relevant key questions. The quality of the evidence was rated according to the GRADE evidence evaluation framework: the evidence levels were based on a systematic review of the literature, and the recommendation grades were classified as either strong or weak. The applicability of the guidelines was considered to meet patients' view and preferences in the context of Korea. The topics of the guidelines cover diagnostic modalities (endoscopy, endoscopic ultrasound, and radiologic diagnosis), treatment modalities (surgery, therapeutic endoscopy, chemotherapy, and radiotherapy), and pathologic evaluation. An external review of the guidelines was conducted during the finalization phase.

Validation of CT-Based Risk Stratification System for Lymph Node Metastasis in Patients With Thyroid Cancer

  • Yun Hwa Roh;Sae Rom Chung;Jung Hwan Baek;Young Jun Choi;Tae-Yon Sung;Dong Eun Song;Tae Yong Kim;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.1028-1037
    • /
    • 2023
  • Objective: To evaluate the computed tomography (CT) features for diagnosing metastatic cervical lymph nodes (LNs) in patients with differentiated thyroid cancer (DTC) and validate the CT-based risk stratification system suggested by the Korean Thyroid Imaging Reporting and Data System (K-TIRADS) guidelines. Materials and Methods: A total of 463 LNs from 399 patients with DTC who underwent preoperative CT staging and ultrasound-guided fine-needle aspiration were included. The following CT features for each LN were evaluated: absence of hilum, cystic changes, calcification, strong enhancement, and heterogeneous enhancement. Multivariable logistic regression analysis was performed to identify independent CT features associated with metastatic LNs, and their diagnostic performances were evaluated. LNs were classified into probably benign, indeterminate, and suspicious categories according to the K-TIRADS and the modified LN classification proposed in our study. The diagnostic performance of both classification systems was compared using the exact McNemar and Kosinski tests. Results: The absence of hilum (odds ratio [OR], 4.859; 95% confidence interval [CI], 1.593-14.823; P = 0.005), strong enhancement (OR, 28.755; 95% CI, 12.719-65.007; P < 0.001), and cystic changes (OR, 46.157; 95% CI, 5.07-420.234; P = 0.001) were independently associated with metastatic LNs. All LNs showing calcification were diagnosed as metastases. Heterogeneous enhancement did not show a significant independent association with metastatic LNs. Strong enhancement, calcification, and cystic changes showed moderate to high specificity (70.1%-100%) and positive predictive value (PPV) (91.8%-100%). The absence of the hilum showed high sensitivity (97.8%) but low specificity (34.0%). The modified LN classification, which excluded heterogeneous enhancement from the K-TIRADS, demonstrated higher specificity (70.1% vs. 62.9%, P = 0.016) and PPV (92.5% vs. 90.9%, P = 0.011) than the K-TIRADS. Conclusion: Excluding heterogeneous enhancement as a suspicious feature resulted in a higher specificity and PPV for diagnosing metastatic LNs than the K-TIRADS. Our research results may provide a basis for revising the LN classification in future guidelines.

Simultaneous Multiple Transmit Focusing Method with Orthogonal Chirp Signal for Ultrasound Imaging System (초음파 영상 장치에서 직교 쳐프 신호를 이용한 동시 다중 송신집속 기법)

  • 정영관;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.49-60
    • /
    • 2002
  • Receive dynamic focusing with an array transducer can provide near optimum resolution only in the vicinity of transmit focal depth. A customary method to increase the depth of field is to combine several beams with different focal depths, with an accompanying decrease in the frame rate. In this Paper. we Present a simultaneous multiple transmit focusing method in which chirp signals focused at different depths are transmitted at the same time. These chirp signals are mutually orthogonal in a sense that the autocorrelation function of each signal has a narrow mainlobe width and low sidelobe levels. and the crossorelation function of any Pair of the signals has values smaller than the sidelobe levels of each autocorrelation function. This means that each chirp signal can be separated from the combined received signals and compressed into a short pulse. which is then individually focused on a separate receive beamformer. Next. the individually focused beams are combined to form a frame of image. Theoretically, any two chirp signals defined over two nonoverlapped frequency bands are mutually orthogonal In the present work. however, a tractional overlap of adjacent frequency bands is permitted to design more chirp signals within a given transducer bandwidth. The elevation of the rosscorrelation values due to the frequency overlap could be reduced by alternating the direction of frequency sweep of the adjacent chirp signals We also observe that the Proposed method provides better images when the low frequency chirp is focused at a near Point and the high frequency chirp at a far point along the depth. better lateral resolution is obtained at the far field with reasonable SNR due to the SNR gain in Pulse compression Imaging .

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF