• 제목/요약/키워드: Ultrasound Intensity

검색결과 218건 처리시간 0.024초

Effects of Combination Treatments of Nisin and High-intensity Ultrasound with High Pressure on the Functional Properties of Liquid Whole Egg

  • Lee, Dong-Un
    • Food Science and Biotechnology
    • /
    • 제18권6호
    • /
    • pp.1511-1514
    • /
    • 2009
  • Liquid whole egg (LWE) was subjected to high hydrostatic pressure (HHP), a consecutive combination of nisin and HHP (nisin-HHP), or a consecutive combination of ultrasound and HHP (ultrasound-HHP), and functional properties of processed LWE were compared to those of raw LWE. Little changes in foaming and emulsifying properties were observed by the application of HHP alone and the combined process of nisin and HHP. In contrast, ultrasound-HHP combination resulted in significant changes in color, foaming, and emulsifying properties. The maintenance of functional properties after HHP treatment agreed with expectation, because the HHP processing condition had been selected where minimal rheological changes had occurred.

Simultaneous Combination Treatment Using High-Intensity Focused Ultrasound and Fractional Carbon Dioxide Laser Resurfacing for Facial Rejuvenation

  • Kang, Hee Yong;Park, Eun Soo;Nam, Seung Min
    • Medical Lasers
    • /
    • 제8권1호
    • /
    • pp.13-18
    • /
    • 2019
  • Background and Objectives High-intensity focused ultrasound (HIFU) can produce small zones of thermal damage. A HIFU procedure is non-invasive and it can achieve rejuvenation of facial skin. Fractional CO2 laser resurfacing delivers thermal damage to the pixilated columnar zone of the skin and so evoke collagen remodeling, the same as HIFU. In many cases, the patients who want rejuvenation with HIFU are also good candidates for cutaneous photorejuvenation such as can be accomplished via fractional CO2 resurfacing. If patients are treated in a single session by remodeling both the superficial and deep compartments of skin by using both modalities, then improvement in rhytides and tightening of sagging skin will optimize the aesthetic result. Materials and Methods Between May 2014 and January 2018, a total of 44 patients were treated with combination HIFU and fractional CO2 laser resurfacing according to our protocol. First, the HIFU was applied to the entire face with an average of 300 treatment lines. Immediately after HIFU treatment, the ultrasound gel was washed off and then fractional CO2 laser resurfacing was performed. We evaluated the patients using 4-point grading scales. The clinician examined the skin for evidence of complications after the completion of treatment. Results All the patients' skin quality showed improvement. Further. the clinical results after duel modality treatment were substantially better than that after the use of either modality alone. The recovery times and the incidence of adverse events when quickly and consecutively performing both treatments were similar as compared to those with employing stepwise treatment. We encountered no complications whatsoever. Conclusion When compared with stepwise therapy, combination therapy with HIFU and fractional CO2 resurfacing offers better, safer and more effective clinical results. Thus, for targeting multiple layers of aging facial skin, this combination therapy can be safely performed in a single treatment session.

The Application of High-Intensity Ultrasound on Wet-Dry Combined Aged Pork Loin Induces Physicochemical and Oxidative Alterations

  • Yu-Min Son;Eun-Yeong Lee;AMM Nurul Alam;Abdul Samad;Md Jakir Hossain;Young-Hwa Hwang;Jeong-Keun Seo;Chul-Beom Kim;Jae-Ha Choi;Seon-Tea Joo
    • 한국축산식품학회지
    • /
    • 제44권4호
    • /
    • pp.899-911
    • /
    • 2024
  • This research investigated the synergic outcome of high intensity ultrasound (HIU) treatment and wet-dry combined aging (WDCA) on physiochemical characteristics and lipid oxidation during refrigerated storage to ameliorate pork meat's quality and shelf life. The CIE b* values, cooking loss (CL %), and pH of the HIU treated samples were higher than those of the control over the aging period. They were significantly (p<0.05) modified by the aging period and ultrasound (US) treatment. However, the released water (RW %) and moisture were not significantly influenced by US treatment (p>0.05). The Warner-Bratzler shear force of HIU-treated samples was lower over control values except in 7-14 d, and it showed a significant difference between control and US treatment according to the significance of HIU (p<0.05). The thiobarbituric acid reactive substance of HIU-treated samples was significantly higher (p<0.05) than control values over the aging period. These results suggested that HIU treatment and WDCA showed a synergistic effect of maximizing the tenderness, but lipid oxidation was higher than before ultrasonic treatment. In agreement with this, the most favorable approach would involve implementing wet aging for a period of two weeks followed by dry aging for a period not exceeding one week after the application of HIU.

Adjuvant로 유발된 관절염의 흰쥐에서 초음파와 고전압 맥동 전류 치료의 효과 (Effects of Ultrasound and High-Voltage Pulsed Current on Adjuvant-Induced Arthritis in Rats)

  • 이동진;이동엽;황돈영
    • 한국전문물리치료학회지
    • /
    • 제13권3호
    • /
    • pp.33-40
    • /
    • 2006
  • The purpose of this study was to assess the effects of High-Voltage Pulsed Current (HVPC) and ultrasound on adjuvant-induced arthritis in rats. Adjuvant arthritis was induced in female Sprauge-Dawley rats by the subcutaneous injection of a single dose of $.1m{\ell}$ of Complete Freund's Adjuvant (CFA) (1 mg of Mycobacterium Butyricum suspended in $.1m{\ell}$ paraffin oil) into the right hind paw. A randomized, parallel-groups design of 24 subjects was used. All rats were randomly assigned to control (n=8), ultrasound (n=8), and HVPC (n=8) were compared with those of injured rats. The rats in the pulsed ultrasound group were treated at 1 MHz frequency with $.5W/cm^2$ intensity in 1:4 mode for 5 minutes per day. The rats in the HVPC group were treated at 120 pulses per second and $50{\mu}s$ phase duration, 20 mA intensity for 30 min per day. Treatment was done in the left and right hind limb for 2 weeks. We evaluated clinical, radiographic, hematologic and histopathologic findings before and after treatment and obtained the following results. 1. Edema of the right hind paw was more significantly reduced in the ultrasound and HVPC groups than the control group on days 9, 12, and 14 (p<.05). Edema of the left hind paw was more significantly reduced in ultrasound and HVPC groups than the control group on days 12, 14 (p<.05). 2. WBC counts of the ultrasound and HVPC groups as compared with the control group were becoming remarkably decreased after the treatment. 3. In radiologic findings, arthritis formation was seen according to the score of arthritis, which was the highest in the control group, upon the observation of radiographs of the left and right hind paws. However, no statistically significant difference was present in the score within three groups. 4. In the histopathologic findings, ultrasound and HVPC groups had effectively suppressed erosions of articular cartilage and inflammatory cell infiltrations. Therefore, the results of the study show that rats that were treated with the ultrasound and HVPC effectively suppressed adjuvant arthritis. However, no statistically significant difference was present between the ultrasound group and the HVPC group.

  • PDF

혐기성 소화 효율 향상을 위한 초음파 주파수의 순차적 적용에 대한 연구 (A Study on Sequential-Frequency Sonication for Improving Anaerobic Digestion)

  • 황규대;박성한
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.893-906
    • /
    • 2011
  • The effect of ultrasound pretreatment on sludge degragability was investigated at different condotions: ultrasonic frequency(28, 40, 50kHz), intensity(10, 25, 50W), sonication time(10, 20, 30, 60min). Total suspended solid(TSS) and soluble chemical oxygen demand(SCOD) concentration were measured for the evaluation of pretreatment efficiency. The pretreated sludge was used as the feedstock for anaerobic digestion process. Biogas production and volatile suspended solid(VSS) removal were determined for evaluating the process performance. 1. TSS concentration of the sludge decreased at a constant rate as sonication operation was applied. The degradation rate of TSS increased when ultrasound frequency was decreased from 50kHz to 28kHz and intensity was increased from 10W to 50W. Efficiency of TSS degradation per input energy increased as ultrasonic frequency and intensity were decreased. At the frequency of 28 and 40kHz, SCOD concentration rapidly increased during the initial 30min of sonication time, and then it gradually increased. At 50kHz, SCOD concentration constantly increased for 60min of the sonication time. The SCOD production rate increased with increasing intensity under all ultrasound frequencies. 2. The optimum condition of ultrasound treatment was 28kHz, 50W and 60min for maximizing the biogas production, methane fraction, VSS removal. The highest values in biogas production, methane fraction in biogas, VSS removal were 370ml, 70%, 2.45g, respectively. Methane production rate per input energy increased at ultrasonic frequency and intensity decreased. 3. When raw sludge was pretreated at the condition of ultrasonic frequency of 28 and 40kHz in series, sequential-frequency sonication, intensity of 50W and 60min, biogas production, methane fraction, VSS removal were about the same that of 28kHz single-frequency sonication. When sequential-frequency sonication of 28 and 50kHz was applied in series, biogas production, methane fraction, VSS removal were 356 ~ 423ml, 69 ~ 71%, 2.41 ~ 2.78g, respectively. The pretreatment efficiency of 28-50kHz sequential-frequency sonication which sonication time of 28kHz and 50kHz was 40min and 20min was higher than that of 28kHz single-frequency sonication.

초음파의 세기를 구하기 위한 수치 해석적 방법 (Numerical Analysis of Ultrasonic Radiation Intensities (In Liquid))

  • 이상희
    • 산업기술연구
    • /
    • 제8권
    • /
    • pp.65-70
    • /
    • 1988
  • The intensity of ultrasound in liquid is calculated by improved analytic method. Helmholtz equation or Rayleigh's proposition does not offer the analytic solution. Considering a bounded medium, the use of the image source method in electromagnetic thoery gives a new way of calculating the total ultrasonic intensity in liquid. Some methods of measuring the intensities are also mentioned.

  • PDF

Study on Changes in Shape of Denatured Area in Skull-mimicking Materials Using Focused Ultrasound Sonication

  • Min, JeongHwa;Kim, JuYoung;Jung, HyunDu;Kim, JaeYoung;Noh, SiCheol;Choi, HeungHo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제3권1호
    • /
    • pp.28-34
    • /
    • 2014
  • Recently, ultrasound therapy has become a new and effective treatment for many brain diseases. Therefore, skull-mimicking phantoms have been developed to simulate the skull and brain tissue of a human and allow further research into ultrasound therapy. In this study, the suitability of various skull-mimicking materials(HDPE, POM C, Acrylic) for studies of brain-tumor treatments was evaluated using focused ultrasound. The acoustic properties of three synthetic resins were measured. The skull-mimicking materials were then combined with an egg white phantom to observe the differences in the ultrasound beam distortion according to the type of material. High-intensity polyethylene was found to be suitable as a skull-mimicking phantom because it had acoustic properties and a denatured-area shape that was close to those of the skull,. In this study, a skull-mimicking phantom with a multi-layer structure was produced after evaluating several skull-mimicking materials. This made it possible to predict the denaturation in a skull in relation to focused ultrasound. The development of a therapeutic protocol for a range of brain diseases will be useful in the future.

Dual Functional Gd(III)-DOTA Liposomes for Cancer Therapy and Diagnosis as a Theragnostic Carrier

  • Han, Hee Dong;Jung, Suk Hyun;Seong, Hasoo;Cho, Sun Hang;Shin, Byung Cheol
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권1호
    • /
    • pp.154-158
    • /
    • 2013
  • Development of dual functional liposome has been studied for cancer theragnostics. Therefore, we focused on ultrasound-sensitive liposomes with doxorubicin (DOX) and gadolinium (Gd) as a theragnostic carrier having a potential for cancer therapy and diagnosis. In this study, Gd(III)-DOTA-modified sonosensitive liposomes (GL) was developed using chemically synthesized Gd(III)-DOTA-DPPE lipid. Sonosensitivity of GL to 1 MHz ultrasound induced 25% of DOX release. The relaxivities ($r_1$) of GL were $7.33-10.34\;mM^{-1}s^{-1}$, which was higher than that of MR-bester$^{(R)}$. Intracellular delivery of DOX from GL by ultrasound irradiation was evaluated according to ultrasound intensity, resulting in increase of uptake of DOX released from ultrasound-triggered GLs compared to GL3 or Doxil$^{(R)}$ without ultrasound. Taken together, this study shows that the paramagnetic and sonosensitive liposomes, GL, is a novel and highly effective delivery system for drug with the potential for broad applications in human disease.

Estimation of Genetic Correlations and Selection Responses for Carcass Traits between Ultrasound and Real Carcass Measurements in Hanwoo Cows

  • Son, Jihyun;Lee, Deukhwan
    • Journal of Animal Science and Technology
    • /
    • 제55권6호
    • /
    • pp.501-508
    • /
    • 2013
  • This study was conducted to determine genetic correlations among carcass traits measured by ultrasound and real carcass measurements and to estimate indirect selection responses for real carcass traits based on ultrasound measurements in Hanwoo cows. To accomplish this, 22,080 ultrasound measurement records from 17,926 cows collected from 2001 to 2012 and 11,907 carcass records obtained from fattened cattle from 2008 to 2012 were used. Genetic parameters were estimated based on eye muscle area (EMA), backfat thickness (BF) and marbling score (MS) measured by ultrasound-scanning of live cows and using the official technique on chilled bovine half-carcasses after slaughtering. Heritability and genetic correlation for carcass traits were estimated using a mixed model equation that consisted of environmental effects as fixed parameters and additive genetic effects and residual effects as random parameters, assuming that traits were different between ultrasound and carcass measurements. This statistical method was applied to the average information restricted maximum likelihood method. The heritability of EMA, BF and MS measured by ultrasound were 0.33, 0.61 and 0.46, respectively, while the heritability estimates of the corresponding traits based on carcass measurements were 0.29, 0.40 and 0.38, respectively and the genetic correlation between ultrasound and carcass traits for EMA, BF and MS were 0.41, 0.78 and 0.67, respectively. The genetic correlation between ultrasound and carcass traits was highly positive. Additionally, the selection response for marbling score was estimated to be 0.42 per generation if the cows were selected based on the ultrasound scan marbling score with an assumed selection intensity of 0.8. Overall, these results indicate that the ultrasound scan technique would be applicable to judging cow selection for genetically improved meat quality.

Feasibility Study of Improved Patch Group Prior Based Denoising (PGPD) Technique with Medical Ultrasound Imaging System

  • Kim, Seung Hun;Seo, Kanghyen;Kang, Seong Hyeon;Kim, Jong Hun;Choi, Won Ho;Lee, Youngjin
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.55-59
    • /
    • 2017
  • The purpose of this study was to quantitatively evaluate image quality using intensity profile, coefficient of variation (COV), and peak signal to noise ratio (PSNR) with respect to noise reduction techniques in the ultrasound images. For that purpose, we compared with the median filter, Rudin-Osher-Fatemi (ROF), Anscombe and proposed patch group prior based denoising (PGPD) techniques. To evaluate image quality, the Shepp-Logan phantom and the ultrasound image were acquired using simulation and experiment, respectively. According to the results, the difference of intensity profile using PGPD technique is lowest compared with original Shepp-Logan phantom. In simulation, the measured COV was 0.249, 0.198, 0.198, 0.177, and 0.080 using noisy, median, ROF, Anscombe and PGPD technique, respectively. Also, in experimental image, the measured COV was 0.245, 0.230, 0.231, 0.242 and 0.187 using noisy, median, ROF, Anscombe and PGPD technique, respectively. Especially, when we used PGPD technique, the PSNR has highest value in both simulation and experiment. In this study, we performed simulation and experiment study to compare various denoising techniques in the ultrasound image. We can expect the PGPD technique to improve in medical diagnosis with excellent noise reduction.