• 제목/요약/키워드: Ultrasound Intensity

검색결과 222건 처리시간 0.031초

맥동성 초음파가 흰쥐 창상치유에 미치는 조직학적 변화 (The Histological Observation of the Effects of Pulsed Ultrasound on Wound Healing of Rats)

  • 김계엽;김태열;나수영;김경윤;김기도;김종만
    • 한국전문물리치료학회지
    • /
    • 제12권1호
    • /
    • pp.80-90
    • /
    • 2005
  • The purpose of this study was to evaluate the effects of pulsed ultrasound on wound healing and observe during the wound healing process the distribution of mast cells according to histopathologic findings. Eighty Sprague Dawley rats which were divided into 4 groups received full thickness skin wounds on the back. Each of the 5 animals was sacrificed immediately and then sacrificed again 1, 3, 6, and 12 days after injury. Specimens from the wounds were removed during healing and routinely processed with a hematoxylin-eosin stain and a toluidine blue stain. The authors then observed the distribution of mast cells under a light microscope. The results of this study were as follows: The rate of wound healing and the length of the wounds of the pulsed ultrasound group II was significantly faster than group I on day 6 and day 12 (p<.001). Group III showed the most significant effect after12 days (p<.001). Group IV also showed a significant effect at 12 days (p<.01). A low-intensity ultrasound .5 $W/cm^2$ resulted in a fast healing rate. During the wound healing process mast cells had a tendency to decrease in the acute inflammatory phase. During the wound healing process mast cells were thought to contribute to the healing of the wound.

  • PDF

말초신경 손상 백서모델에서 초음파 치료의 신경 및 근육 재생효과 (The Effect of Ultrasound Treatment on Regeneration Nerve and Muscle on Injured Peripheral Nerve of Rats Model)

  • 정미선;김경윤
    • The Journal of Korean Physical Therapy
    • /
    • 제17권4호
    • /
    • pp.589-600
    • /
    • 2005
  • The purposes of this study is to discuss and analyze the effect on the recovery from cut in sciatic nerve. This study used 9 weeks male rats of Sprague-Dawley family. Rat in groups 4 were treated with pulsed therapeutic ultrasound for 3 minutes. 3 times weekly at 3MHz respectively (intensity; $0.2W/cm^2,\;0.5W/Cm^2,\;10W/cm^2$); rat in group 1 received placebo ultrasound. In addition, changes of serum aspartate amino-transferase(AST) and creatine phosphokinase(CPK) levels were also demonstrated with diameter of individual muscle fasciculate and number of muscle fiber in each of three types of muscles located in gastrocnemius, soles. The results of comparing the changes in groups are as follows; 1. We found out that hypertrophic epineurium was present in sciatic nerve injured ultrasound treatment of groups. 2. In the gastrocnemius morphological investigation of the group I (control group), severe muscle atrophy were observed at the 7th days of the sciatic nerve injury. however, muscle atrophy of the group IV ($1.0W/cm^2$) were slightly recovered at the 14th days after treatment ultrasound. At the 28th days, muscular fibers were formed in polygon and were significantly recovered. 3. C-fos immunoreactive of the group II ($0.2W/cm^2$), III ($0.5W/cm^2$) were remarkably increased at the 1th day after treatment of ultrasound. Group IV were markedly deceased. 4. Brain-Derived Neurotrophic Factor(BDNF) immunoreactive of the group II, III were increased after 7 days of the sciatic nerve injury. Group IV were markedly increased from 14th days to 28th days after treatment of ultrasound. 5. A significant increase of serum AST levels were demonstrated in control group. However, serum AST levels of massage groups were significantly decreased compared to that of control group in followed order ; ($0.2W/cm^2<0.5W/cm^2<1.0W/cm^2$). 6. A significant increase of serum CK levels were demonstrated in control of group. However, serum CK levels of massage groups were significantly decreased compared to that of control group in followed order ; ($0.2W/cm^2<0.5W/cm^2<1.0W/cm^2$). The above results suggest that ultrasound treatment after peripheral nerve injury might reduce noxious stimuli, facilitate nerve recovery and effective in the functional improvement delaying muscle atrophy or degeneration.

  • PDF

Intensity of Intraoperative Spinal Cord Hyperechogenicity as a Novel Potential Predictive Indicator of Neurological Recovery for Degenerative Cervical Myelopathy

  • Guoliang Chen;Fuxin Wei;Jiachun Li;Liangyu Shi;Wei Zhang;Xianxiang Wang;Zuofeng Xu;Xizhe Liu;Xuenong Zou;Shaoyu Liu
    • Korean Journal of Radiology
    • /
    • 제22권7호
    • /
    • pp.1163-1171
    • /
    • 2021
  • Objective: To analyze the correlations between intraoperative ultrasound and MRI metrics of the spinal cord in degenerative cervical myelopathy and identify novel potential predictive ultrasonic indicators of neurological recovery for degenerative cervical myelopathy. Materials and Methods: Twenty-two patients who underwent French-door laminoplasty for multilevel degenerative cervical myelopathy were followed up for 12 months. The Japanese Orthopedic Association (JOA) scores were assessed preoperatively and 12 months postoperatively. Maximum spinal cord compression and compression rates were measured and calculated using both intraoperative ultrasound imaging and preoperative T2-weight (T2W) MRI. Signal change rates of the spinal cord on preoperative T2W MRI and gray value ratios of dorsal and ventral spinal cord hyperechogenicity on intraoperative ultrasound imaging were measured and calculated. Correlations between intraoperative ultrasound metrics, MRI metrics, and the recovery rate JOA scores were analyzed using Spearman correlation analysis. Results: The postoperative JOA scores improved significantly, with a mean recovery rate of 65.0 ± 20.3% (p < 0.001). No significant correlations were found between the operative ultrasound metrics and MRI metrics. The gray value ratios of the spinal cord hyperechogenicity was negatively correlated with the recovery rate of JOA scores (ρ = -0.638, p = 0.001), while the ventral and dorsal gray value ratios of spinal cord hyperechogenicity were negatively correlated with the recovery rate of JOA-motor scores (ρ = -0.582, p = 0.004) and JOA-sensory scores (ρ = -0.452, p = 0.035), respectively. The dorsal gray value ratio was significantly higher than the ventral gray value ratio (p < 0.001), while the recovery rate of JOA-motor scores was better than that of JOA-sensory scores at 12 months post-surgery (p = 0.028). Conclusion: For degenerative cervical myelopathy, the correlations between intraoperative ultrasound and preoperative T2W MRI metrics were not significant. Gray value ratios of the spinal cord hyperechogenicity and dorsal and ventral spinal cord hyperechogenicity were significantly correlated with neurological recovery at 12 months postoperatively.

저강도 원심성 운동과 동적 스트레칭이 지연성 근육통에 미치는 효과 비교 (The Comparison of Low Intensity Eccentric Exercise and Dynamic Stretching on Delayed Onset Muscle Soreness)

  • 이수영;김지윤
    • 한국산학기술학회논문지
    • /
    • 제13권10호
    • /
    • pp.4676-4685
    • /
    • 2012
  • 본 연구는 저강도 원심성 운동과 동적 스트레칭이 지연성 근육통에 미치는 효과를 비교하고자 시행하였다. 본 연구의 대상자는 연구에 참여하기 5개월 전부터 하지에 규칙적인 운동을 하지 않았던 18명의 20대 건강한 여성을 대상으로 하였다. 대상자들은 전체 3그룹인 대조군, 저강도 원심성 운동군 그리고 동적 스트레칭군에 무작위로 배정되었다. 측정변수로는 최대 수의적 등척성 수축력, 초음파 영상을 통한 근 두께, 근 통증 척도, 무릎관절 가동범위이며 지연성 근육통 유발 전, 유발 후 24시간, 48시간, 72시간에 각각 측정되었다. 저강도 원심성 운동군과 동적 스트레칭군의 운동 프로그램은 지연성 근육통 유발 4주 전에 일주일에 3회씩 각각 시행되었다. 본 연구의 결과 최대 수의적 등척성 수축력과 근 통증 척도에서만 그룹간 유의한 차이가 있었으며(p<.05), 저강도 원심성 운동은 동적 스트레칭에 비해 근 통증 척도가 유의하게 감소하였다(p<.05). 그러므로 저강도 원심성 운동과 동적 스트레칭이 지연성 근육통의 증상 중 근 통증에 효과적임을 제시하며 또한 저강도 원심성 운동이 동적 스트레칭보다 근 통증을 빠르게 감소시킴으로써 근 통증에 더 효과적임을 제시하고자 한다.

조영증강 초음파영상에서 밀도변화 데이터를 이용한 진단 파라미터 추출 기법 (Medical Parameter Extraction Using Time-Density Data in Contrast-Enhanced Ultrasound Image Sequence)

  • 이준용;정중은;김호준
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제4권7호
    • /
    • pp.297-300
    • /
    • 2015
  • 의료 진단 초음파영상에서 조영제의 전이시간과 확산패턴의 형태는 질환 및 병변을 분석하는 중요한 파라미터로 고려된다. 조영증강 초음파영상 분석과 관련한 기존의 대부분의 연구에서 대상 영역의 평균 명도 변화곡선을 기반으로 파라미터값을 추출한다. 그런데 이러한 명도 데이터는 조영제의 마이크로 버블 효과로 인하여 그 값이 왜곡될 수 있다. 이에 본 논문에서는 조영증강 초음파 진단 파라미터의 추출 과정에서 그 정확도를 개선하기 위하여 명도값의 변화뿐만 아니라, 조영제의 영향을 반영하는 픽셀에 대한 밀도 정보를 보완적으로 활용하는 방법을 제안한다. 제안된 기법은 간 질환 진단 과정에서 병변의 윤곽선 추출과 병변의 특성분석을 위하여 조영제의 확산시점과 속도를 보다 정확하게 판별할 수 있게 한다. 실제 임상 데이터를 사용한 실험결과를 통하여, 제안된 방법이 파라미터 영상 생성기법에서 개선된 결과를 생성할 수 있음을 보인다.

Novel Laser Ultrasonic Receiver for Industrial NDE

  • Pouet, B.;Breugnot, S.;Clemenceau, P.
    • 비파괴검사학회지
    • /
    • 제26권6호
    • /
    • pp.380-389
    • /
    • 2006
  • A new laser-based ultrasonic receiver that is based on multi-channel interferometry is shown to be well suited for robust and sensitive detection of ultrasound in industrial environment. The proposed architecture combines random-quadrature detection with detector arrays and parallel multi-speckle processing. The high sensitivity is reached, thanks to the random phase distribution of laser speckle caused by surface roughness. High-density parallel signal processing is achieved by using a simple demodulation technique based on signal rectification. This simple detection scheme is also demonstrated for rejection of the laser intensity noise, making possible the use of lower cost laser without reduction in performances. Results demonstrating this new principle of operation and its performances are presented.

초음파 가열 시 In Vitro 및 In Vivo에서 Microwave Radio-Thermometer와 탐침온도계의 일치도 (In Vitro and In Vivo Agreement of Microwave Radio-Thermometer and Needle Probe Thermometer During Therapeutic Ultrasound)

  • 이수영;조상현;이충휘;김종만
    • 한국전문물리치료학회지
    • /
    • 제10권1호
    • /
    • pp.15-27
    • /
    • 2003
  • Therapeutic ultrasound is commonly applied for deep heating in physical therapy setting. However, it is difficult to determine the exact application dosage and to confirm the immediate heating effect. Microwave Radio-Thermometer (MRT) can measure the temperature by the electromagnetic energy in the microwave region of the object that emits above absolute zero temperature. MRT was used for early diagnosis of breast cancer since it was not harmful, non-invasive, and non-ionizing to the human body. The purposes of this study were to investigate how accurately 1.1 GHz RTM (RES Ltd. Russia) measures the change of average temperature in the tissue, and to determine the depth of temperature change measurement. Therapeutic ultrasound was applied (continuous wave for 5 minutes, 1 MHz, intensity of 1.5 $W/cm^2$ [in vitro] and 1.0 $W/cm^2$ [in vivo]) in four different conditions: (1) 30 cases of in vitro specimen of pork, (2) 30 cases of in vitro specimen of pork ankle joint, (3) 10 cases of in vivo canine thigh, and (4) 30 cases of in vivo human body. Intraclass Correlation Coeffients (ICC[3,1]) between average needle probe thermometer below surface and MRT temperature was revealed as followed: (1) Before ultrasound application ICCs ranges above .8 in specimen of pork (15 mm underneath the skin) and above .82 in specimen of pork ankle joint (10~30 mm underneath the skin). (2) After ultrasound application ICCs ranges above .7 in both specimens of pork and pork ankle joint. (3) Before ultrasound application ICCs ranges above .8 in canine thigh (20 mm underneath the skin). (4) After ultrasound application ICCs ranges above .82 in canine thigh. The temperature of the human body increased significantly with the mean of $15^{\circ}C$ in muscle tissue and with the mean of $3.5^{\circ}C$ in joint (p<.00). It was revealed that the average depth of temperature measurement of the tissue by MRT was in between 10 and 35 mm, and determined that the proper temperature measurement band was $36.5{\sim}37.0^{\circ}C$.

  • PDF

골다공증 유도 백서 경골에 티타늄 임플랜트 매식 시 지방조직유래 줄기세포 주입과 저출력 초음파 적용이 골치유에 미치는 영향 (Effect of Low Intensity Pulsed Ultrasound with Adipose-Derived Stem Cells on Bone Healing around a Titanium Implant in Tibia of Osteoporosis-Induced Rats)

  • 이광호;최연식;신상훈;정인교;김규천;김철훈;김욱규
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제33권3호
    • /
    • pp.199-209
    • /
    • 2011
  • Purpose: Osteoporosis, is a major health problem for the elderly and post-menopausal women and shown to alter the properties of bone as well as impair bone healing around titanium implants in both human and animals. The objective of this study was to examine the effect of LIPUS with adipose-derived stem cells on the healing process around a titanium implant in rats with osteoporosis. Methods: Sixteen osteoporosis-induced rats were divided into two groups: an adipose-derived stem cell injected with Low Intensity Pulsed Ultrasound (LIPUS) application group and a control group. Titanium screw implants (diameter, 2.0 mm: length, 3.5 mm, Cowell Medi, Korea) were placed into both tibia of 16 rats, on 8 rats as the control group and the other 8 rats as the experimental group. Rats were sacrificed at different intervals from 1, 2, 4 and 8 weeks after implantation for histopathologic and immunohistochemical analyses. Results: Histopathological analysis revealed newly formed bone in experimental group earlier than that in control group. Especially at 1 week after implantation, more amounts of new bone matrix and collagen around the implant in the experimental group were seen compared with the control group. Immunohistochemical analysis showed that the levels of osteoprotegerin (OPG) expression in the experimental group were increased at early stages compared with that of control group until 2 weeks after implantation. But after 2 weeks, the expression level of OPG similar in both groups. The expression levels of receptor activator of nuclear factor kB ligand (RANKL) were stronger in the experimental group than the control group until 2 weeks after implantation. After 4 weeks, expression of RANKL in experimental group was similar to the control group. Conclusion: The results of this study suggest that LIPUS with Adipose-Derived Stem Cells in implantation could promote bone healing around titanium implants in rats with osteoporosis.

역학적 강도 분석을 이용한 저강도 초음파의 조사 부위의 골다공증 골절 방지 효과 평가 (In vivo Evaluation of Osteoporotic Fracture Prevention of the site to which low Intensity Ultrasound is Irradiated using Mechanical Strength Simulations)

  • 우대곤;김치훈;박지형;고창용;김한성;김진만;김상희;임도형
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권2호
    • /
    • pp.135-141
    • /
    • 2009
  • Purpose: The aim of present study is to evaluate a possibility of clinical application for the effect of low intensity ultrasound stimulation (LIUS) in mechanical characteristics of bone on osteoporotic fractures prevention. Materials and Methods: Eight virgin ICR mice (14 weeks old, approximate weight 25g) were ovariectomized (OVX) to induce osteoporosis. The right hind limbs were then stimulated with LIDS (US Group), whereas left hind limbs were not stimulated (CON Group). Both hind limbs of all mice were scanned by in-vivo micro-CT to acquire two-dimensional (2D) images at 0 week before stimulation and 3 weeks and 6 weeks after stimulation. Three-dimensional (3D) finite element (FE) models generated by scanned 2D images were used to determine quantitatively the effect of LIUS on strength related to bone structure. Additionally, distributions of Hounsfield units and elastic moduli, which are related to the bone quality, for the bones in the US and CON groups were determined to analyze quantitatively a degree of improvement of bone qualities achieved by LIUS. Results: The result of FE analysis showed that the structural strength in US Group was significantly increased over time (p<0.05), while that in CON Group was statistically constant over time (p>0.05). High values of Hounsfield units obtained from voxels on micro-CT images and high values of elastic moduli converted from the Hounsfield units were dominantly appeared in US Group compared with those in CON Group. Conclusion: These finding indicated that LIUS would improve the mechanical characteristics of osteoporotic bone via the effects of bone structure (bone strength) and quality (Hounsfield unit and elastic modulus). Therefore, the LIUS may decrease effectively the risk of osteoporotic fracture in clinics.

Comparative Study on Transcatheter Arterial Chemoembolization, Portal Vein Embolization and High Intensity Focused Ultrasound Sequential Therapy for Patients

  • Cui, Lin;Liu, Xing-Xiang;Jiang, Yong;Wu, Xing-Jun;Liu, Jian-Jun;Zhou, Xiang-Rong;He, Xue-Jun;Huang, Xin-En
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권12호
    • /
    • pp.6257-6261
    • /
    • 2012
  • Objective: To investigate the safety and efficacy of transcatheter arterial chemoembolization (TACE), combined with portal vein embolization (PVE), and high intensity focused ultrasound (HIFU) sequential therapy in treating patients with hepatocellular carcinoma (HCC). Methods: Patients with inoperative HCC were treated by two methods: in the study group with TACE first, then PVE a week later, and then TACE+PVE every two months as a cycle, after 2~3 cycles finally HIFU was given; in the control group only TACE+PVE was given. Response (CR+PR), and disease control rate (CR+PR+SD), side effects, overall survival and time to progress were calculated. Results: Main side effects of both groups were nausea and vomiting. No treatment related death occurred. In the study group, 32 patients received TACE for overall 67 times, PVE 64 times, and HIFU 99 times; on average 2.1, 2 and 3.1 times for each patient, respectively. In the control group, 36 patients were given TACE 78 times and PVE 74 times, averaging 2.2 and 2.1 times per patient. Effective rate: 25.0% in study group and 8.3% in control group (p>0.05). Disease control rates were 71.9% and 44.4%, respectively (p<0.05). In patients with portal vein tumor thrombus, the rate reduced over 1/2 after treatment was 69.2%(9/13) in the study and 21.4%(3/14) in the control group (p<0.05). Rate of AFP reversion or decrease over 1/2 was 66.7%(16/24) in study and 37%(10/27) (p<0.05) in control group. Median survival time: 16 months in study and 10 months in control group. PFS was 7months in study and 3 months in control group. Log-rank test suggested that statistically significant difference exists between two groups (p=0.024). 1-, 2- and 3-year survival rates were 56.3%, 18.8% and 9.3% in study, while 30.6%, 5.6% and 0 in control group, respectively, with statistically significant difference between two groups (by Log-rank, p = 0.014). Conclusions: The treatment of TACE+PVE+HIFU sequential therapy for HCC increases response rate, prolong survival, and could thus be a safe and effective treatment for advanced cases.