• Title/Summary/Keyword: Ultrasound Image

Search Result 423, Processing Time 0.026 seconds

Speckle Noise Reduction with Morphological Adaptive Median Filtering Based on Edge Preservation

  • Jung, Eun Suk;Ryu, Conan K.R.;Hur, Chang Wu;Sun, Mingui
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.329-332
    • /
    • 2009
  • Speckle noise reduction for ultrasound CT image using morphological adaptive median filtering based on edge preservation is presented in this paper. Speckle noise is multiplicative feature and causes ultrasound image to degrade widely from transducer. An input image is classified into edge region and homogeneous region in preprocessing. The speckle is reduced by morphological operation on the 2D gray scale by using convolution and correlation, and edges are preserved. The adaptive median is processed to reduce an impulse noise. As the result the proposed method enhances the image to about 20% in comparison with Winer filter by Edge Preservation Index and PSNR.

  • PDF

Ultrasound Transducers in Several Tens MHz Band and Their Applications (수십 MHz 대역 초음파 트랜스듀서와 그 응용)

  • 하강렬;김무준
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.8
    • /
    • pp.622-628
    • /
    • 2003
  • Recently, ultrasound transducers in several tens MHz band, which can give the spatial resolution higher than several tens micrometers, have been intensively studying for applying to medical diagnostic fields of ophthalmology and dermatology. In this paper, the background of the studies, structures and characteristics of the transducers, and images obtained by the transducers are briefly reviewed.

Fast Volume Visualization Techniques for Ultrasound Data

  • Kwon Koo-Joo;Shin Byeong-Seok
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.1
    • /
    • pp.6-13
    • /
    • 2006
  • Ultrasound visualization is a typical diagnosis method to examine organs, soft tissues and fetus data. It is difficult to visualize ultrasound data because the quality of the data might be degraded by artifact and speckle noise, and gathered with non-linear sampling. Rendering speed is too slow since we can not use additional data structures or procedures in rendering stage. In this paper, we use several visualization methods for fast rendering of ultrasound data. First method, denoted as adaptive ray sampling, is to reduce the number of samples by adjusting sampling interval in empty space. Secondly, we use early ray termination scheme with sufficiently wide sampling interval and low threshold value of opacity during color compositing. Lastly, we use bilinear interpolation instead of trilinear interpolation for sampling in transparent region. We conclude that our method reduces the rendering time without loss of image quality in comparison to the conventional methods.

Noise Using Wavelet Pattern Change of Real-time Ultrasound Image (실시간 초음파 영상의 웨이블릿 패턴 변화를 이용한 노이즈 제거)

  • Cho, Young-bok;Woo, Sung-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.510-512
    • /
    • 2018
  • The proposed method enhances the resolution of images by removing noise using wavelet transform to remove noise from images generated by ultrasound diagnosis. We propose an algorithm to reduce the speckle noise and enhance the edge of the ultrasound image. The proposed algorithm can enhance edges of various sizes by using wavelet transform which can use both frequency and spatial information. Experimental results show that the performance of the algorithm for noise reduction of ultrasound images is about 0.45ms for $520{\times}440$ images.

  • PDF

Measurement of the Average Speed of Ultrasound and Implementation of Its Imaging Using Compounding Technique in Medical Ultrasound Imaging (초음파 의료영상에서 컴파운딩 기법을 이용한 초음파의 평균 음속도의 측정과 음속도 영상의 구현)

  • Jeong, Mok-Kun;Kwon, Sung-Jae;Choi, Min-Joo
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.3
    • /
    • pp.233-240
    • /
    • 2009
  • Using a spatial compound imaging technique in a medical ultrasound imaging system, the average speed of sound in a medium of interest is measured, and imaging of its distribution is implemented. When the brightness reaches the highest level in an ultrasonic image obtained as the speed of sound used in focusing is varied, it turns out that the focusing has been accomplished satisfactorily and that the speed of sound which has been adopted becomes the sought-after average speed of sound. Because spatial compound imaging provides many different views of the same object, the adverse effect of erroneous speed-of-sound estimation tends to be more severe in compound imaging than in plain B-mode imaging. Thus, in compound imaging, the average speed of sound even in the case of speckled images can be accurately estimated by observing the brightness change due to different speeds of sound employed. Using this new method that offers spatial diversity, we can construct an image of the speed of sound distribution in a phantom embedded with a 10-mm diameter plastic cylinder whose speed of sound is different from that of the background. The speed of sound in the cylinder is found to be different from that of the surrounding medium.

Analysis of characteristics for computer-aided diagnosis of breast ultrasound imaging (유방 초음파 영상의 컴퓨터 보조 진단을 위한 특성 분석)

  • Eum, Sang-hee;Nam, Jae-hyun;Ye, soo-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.307-310
    • /
    • 2021
  • In the recent years, studies using Computer-Aided Diagnostics(CAD) have been actively conducted, such as signal and image processing technology using breast ultrasound images, automatic image optimization technology, and automatic detection and classification of breast masses. As computer diagnostic technology is developed, it is expected that early detection of cancer will proceed accurately and quickly, reducing health insurance and test ice for patients, and eliminating anxiety about biopsy. In this paper, a quantitative analysis of tumors was conducted in ultrasound images using a gray level co-occurrence matrix(GLCM) to experiment with the possibility of use for computer assistance diagnosis.

  • PDF

Optically transparent ultrasound transducers for combined ultrasound and photoacoustic imaging: A review (초음파-광음향 융합 영상을 위한 투명 초음파 변환기)

  • Shunghun Park;Jin Ho Chang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.441-451
    • /
    • 2023
  • Ultrasound transducers are an essential component of combined photoacoustic and ultrasound imaging systems and play an important role in image evaluation. However, ultrasound transducers are opaque; therefore, light must bypass the ultrasound transducer to reach the target point to produce a photoacoustic image. Providing different paths for the optical and acoustic signals results in a complicated system design, increasing the system volume. To overcome these problems, an optically Transparent Ultrasound Transducer (TUT) was developed. Unlike conventional opaque ultrasound transducers, optically TUT can be fabricated by a variety of manufacturing methods and they are suitable for use with specific piezoelectric elements and serve various purposes. In this study, a comparative analysis of the results of using Lithium Niobate (LNO), Lead Magnesium Niobate-Lead Titanate (PMN-PT), and Polyvinylidene Difluoride (PVDF), which are materials used in piezoelectric element-based TUT. LNO is a piezoelectric element widely used in TUT, and PMN-PT has been actively studied recently with a higher transmission and reception rate than LNO. Existing TUT have lower ultrasound resolution than photoacoustic resolution, but they have recently been manufacturing focused TUT with high ultrasound resolution using PVDF. A comparative analysis of the production results of these TUT was performed.

Automatic Multi-threshold Detection Algorithm for the Segmentation of Echocardiographic Images (심초음파 영상의 영역 분류를 위한 다중 문턱치 자동 검출 알고리듬)

  • Choi, Chang-Hou;Koo, Sung-Mo;Kim, Myoung-Nam;Cho, Sung-Mok;Cho, Jin-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.39-42
    • /
    • 1994
  • An automatic multi-threshold algorithm for segmentation of 2D ultrasound images based on average filtering and the characteristics of speckle noise in 2D ultrasound image is proposed. To do this, we investigate the histogram of difference between $7{\times}7$ averaging histogram and $3{\times}3$ averaging histogram. And, we find zero crossing points in the positive portion of the differenced histogram and select middle points of the zero crossing points. We assign these selected points to characteristic points. The thresholds are the center of two characteristic points. Then we segment 2D ultrasound image by using these thresholds and extract edges from applying edge operator to optimal segmented image. Experimental results show that the segmented regions are devided accurately around the homogeneous region.

  • PDF

Quantization of Lumbar Muscle using FCM Algorithm (FCM 알고리즘을 이용한 요부 근육 양자화)

  • Kim, Kwang-Baek
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.8
    • /
    • pp.27-31
    • /
    • 2013
  • In this paper, we propose a new quantization method using fuzzy C-means clustering(FCM) for lumbar ultrasound image recognition. Unlike usual histogram based quantization, our method first classifies regions into 10 clusters and sorts them by the central value of each cluster. Those clusters are represented with different colors. This method is efficient to handle lumbar ultrasound image since in this part of human body, the brightness values are distributed to doubly skewed histogram in general thus the usual histogram based quantization is not strong to extract different areas. Experiment conducted with 15 real lumbar images verified the efficacy of proposed method.

A study on growth and development of children by Ultrasound transonic velocity of inferior radiocarpal joint (완관절 초음파통과속도를 이용한 골연령 측정값과 X-ray영상을 이용한 골연령 측정값의 비교)

  • Koh, Duck-Jae;You, Han-Jung;Lee, Jin-Yong;Kim, Deog-Gon;Yoon, Kyung-Hee
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.165-174
    • /
    • 2005
  • Objectives : The purpose of this study was to suggest a new method for measurement of children's growth development Ultrasound transonic velocity of inferior radiocarpal joint has some advantages that it is harmless to human body and apply a new analysis algorithm, it can be used for the diagnosis of bone age. Methods: This clinical study have been carried out with the 117 case(male 68, female 49) of the children aged 5 to 16 years old who visited in Department of Pediatrics, ${\bigcirc}{\bigcirc}$ university Oriental Hospital. Bone maturity is measured by Ultrasound transonic velocity and X-ray image of growth plate in inferior radiocarpal joint. This study were designed to investigate the relationship of the bone age by Ultrasound transonic velocity and X-ray image. Result & Conclusion : The maturity of growth plate of inferior radiocarpal joint was correlated with age, height, weight, BMI in this study(P<0.001). The Ultrasound transonic velocity of inferior radiocarpal joint are sufficient diagnostic worth as an index to predict bone maturity.

  • PDF