• Title/Summary/Keyword: Ultrasound Doppler

Search Result 157, Processing Time 0.027 seconds

Special Issue for Biomedical Ultrasound: Towards Further Advances in Fundamentals and Applications by Comprehensive Reviews

  • Kim, Yong-Tae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.3E
    • /
    • pp.107-110
    • /
    • 2010
  • In this paper, the rationale and contents of the special issue of the Journal of the Acoustical Society of Korea regarding comprehensive reviews on past, present and future of biomedical ultrasound are described. Brief descriptions of invited articles are given, and efforts by all contributing authors are gratefully acknowledged.

A Study on Central Vein Cannulation Using Audible Doppler Guidance in Children and Infants (Audible Doppler Ultrasound(8 MHz)를 이용한 소아와 영아에서 중심정맥 도관 삽입술에 관한 연구)

  • Ahn, Young Joon;Jung, Jin Young;Hong, Soo-Jong
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.9
    • /
    • pp.1120-1125
    • /
    • 2002
  • Purpose : Percutaneous cannulation of the central vein in children and infants may be technically difficult and can cause serious complications. There are many techniques to improve the success rate and to decrease the complications in central vein cannulation. This study was undertaken to determine whether audible Doppler guidance can help operators improve the results of central vein cannultion in pediatric ICU. Methods : A total of 46 central vein cannulations were performed using audible Doppler guidance technique. Using an 8-MHz Doppler ultrasound device(Pocket-Dop II. iMex. USA), the artery and the vein were identified by their characteristic Doppler sounds. Results : There was a total of 46 patients with 20 boys and 26 girls, respectively. The mean age was $3years{\pm}45months$(range : 1-156 months). The number of infants was 18 and the mean age was $6.3{\pm}3.8$ months(range : 1-12 months). The most common site of central vein cannulation was the right internal jugular vein(63%). The cannulation was successful in 44 out of 46 procedures(96%). The success rate at the first attempt was 59% with 48% in the patients who had the history of previous cannulation and 70% in the patients who did not, respectively. The success rate in infants was 94%(17 out of 18). The average access time was $5.2{\pm}8.3$ minutes in children contrary to $7.5{\pm}10.3$ minutes in infants. There were no serious complications, but six patients had complications including four hematoma, one arterial puncture, and one pneumothorax. Conclusion : This central vein cannulation using Doppler guidance may improve the success rate of central vein cannulation and decrease the development of serious complications in infants and children.

Noninvasive Estimation of Moxibustion Effect on Peripheral Blood Flow by Doppler Ultrasound in Stroke Patients with Hemiplegia: Case Series (뜸치료가 뇌졸중 편마비의 요골동맥 혈류변화에 대해 미치는 영향)

  • Yoon, Seung-Kyou;Lee, Sang-Hoon;Jung, Woo-Sang;Bae, Young-Min
    • The Journal of Korean Medicine
    • /
    • v.31 no.4
    • /
    • pp.178-186
    • /
    • 2010
  • Objectives: This study was to investigate the effect of moxibustion on peripheral blood flow by Doppler ultrasound in post-stroke hemiplegia patients. Methods: Moxibustion was applied on the points of LI4, TE3, TE5 and LI11 on the affected side, and blood flow of the radial artery was measured using the Minimax-Doppler-K device. Blood flow velocity and pulsation index were analyzed before, during, and after moxibustion. Results: The mean value of blood flow velocity in 13 patients showed a tendency of increase during moxibustion, but there was no significant difference in blood flow velocity before and after moxibustion, or pulsation index during and after moxibustion. In addition, among the five patients who showed marked increase tendency on the blood velocity graph, there was significant increase in blood velocity during, and after moxibustion compared with before moxibustion. Conclusions: This study suggests that moxibustion has an effect on peripheral blood flow in stroke patients with hemiplegia. Further validity tests with a larger scale sample are needed for the evidence of its practical use.

Blood Flow in an Aortic Bifurcation Model: Pulsed Doppler Ultrasound and Laser Doppler Anemometry Studies (대동맥분기에서의 혈액유동: 맥도플러초음파 및 레이저도플러계측기를 사용한 연구)

  • Kim, Young-H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.43-46
    • /
    • 1992
  • $\underline{In\;vitro}$ velocity measurements were made using both the pulsed Doppler ultrasound (PDU) machine and laser Doppler anemometer (LDA) system in order to investigate the flow characteristics near the aortic bifurcation. Velocities measured from the PDU machine was in good agreement with those from the LDA. The flow in the daughter branches was three-dimensional with a secondary flow. The oscillating wall shear stress with this secondary fluid motion is well correlated with the localization of the atherosclerosis.

  • PDF

Three-Dimensional Flow in an Aortic Bifurcation Model: Comparison of In Vitro Experiments and Numerical Simulation (대동맥 분기관 모델 내 삼차원 유동: In vitro 실험과 수치해석의 비교)

  • Kim, Young-H.;Seo, Sang-H.;Ryu, Sang-S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.15-18
    • /
    • 1995
  • Three-dimensional steady and pulsatile flow experiments and numerical simulations have conducted to investigate the flow characteristics in the aortic bifurcation model. In vitro velocity measurements were made using both laser Doppler anemometry and pulsed Doppler ultrasound velocimetry. In this study, flow phenomena in the aortic bifurcation model are discussed extensively and the numerical results are compared with experimental results.

  • PDF

The Impacts of Piezoelectric Elements' Defects On Color & Power Doppler Images (초음파 프로브에서 소자결함이 컬러 및 파워 도플러 영상에 미치는 영향)

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2015
  • An ultrasound probe has a big impact on Doppler images even though it has very high risk of frequent function-breakdowns occurring in medical ultrasound scanners. This study experimentally analyses the impacts of an ultrasonic probe's defected elements on power & color Doppler images. The results show that, the bigger the size of defected probe elements is, and the closer a group of action elements is to the center, the more the brightness of images and the velocity of Doppler diminish. When elements' defects increase in color & power Doppler images, false images are formed to be mistaken for blood-vessel plaque in neighboring regions. Accordingly, whenever element defects are suspected, we need check-up process in B-mode. From this respective, it is advisable to have primary interest in a probe and carry out continuous probe QA for ultrasonography.

Study of Spectral Doppler Waveform Interpretation and Nomenclature in Peripheral Artery (말초 동맥 분광 도플러 파형 해석 및 명명법에 대한 고찰)

  • Ji, Myeong-Hoon;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.649-660
    • /
    • 2022
  • In 1959, Satomura used spectral Doppler ultrasound to express the velocity of red blood cells according to time change, and Kato defined a zero-base line that could tell the direction of blood flow, making it possible to know the direction of blood flow. This became the basis for the widely used classifications of Triphasic, Biphasic, and Monophasic. However, the above classification has limitations that confuse users with the meaning and timing of use in a clinical environment. As a result, the American Society for Vascular Medicine (SVM) and the Society for Vascular Ultrasound (SVU) A consensus document on Doppler waveform analysis was declared by the joint committee. This study tried to review this consensus and to suggest nomenclature and modifiers that can be used in the domestic vascular ultrasound clinical field. The joint committee formed by SVM and SVU recommended that the use of the triphasic waveform and the biphasic waveform be used as a multiphasic waveform rather than being used due to the ambiguity of interpretation. In addition, it was agreed to name the hybrid-type waveform, which is a monophasic and high-resistance waveform, which has always been a problem of interpretation in a clinical environment, as an intermediate resistive waveform. In addition, in order to increase the communication efficiency between the interpreter and the sonographer, waveform analysis was classified into a main descriptor and a modifier, and it was recommended to use a single nomenclature by unifying various synonyms. It is expected that this literature review will provide accurate arterial spectral Doppler waveform interpretation and an agreed-upon nomenclature to radiologists performing vascular ultrasound examination in clinical practice, and will be utilized as basic data that can contribute to the improvement of public health.

Clinical Observation on Heart Rate Variability and Peripheral Blood Flow by Doppler Ultrasound in Healthy Subjects Stimulated by Cold Stress (정상인의 한냉자극에 대한 심박변이도 및 도플러 초음파 혈류계를 이용한 말초 혈류관찰)

  • Lim, Sung-Keun;Lee, Sang-Hoon;Bae, Young-Min
    • The Journal of Korean Medicine
    • /
    • v.31 no.2
    • /
    • pp.114-123
    • /
    • 2010
  • Objectives: This study was performed to investigate the effect of cold stress on heart rate variability and peripheral blood flow by Doppler ultrasound in healthy subjects. Methods: We classified the subjects by their Yin or Yang tendency using a Yin-Yang questionnaire. Cold stress was taken on the left hand of subjects for 10 seconds. Heart rate variability and peripheral blood flow were measured on the right radial artery before and after cold stress. Results: The Yang tendency group showed a significant decrease of heart rate after cold stress which was not seen in the Yin tendency group. The Yang tendency group showed a decrease of LF, total power, and increase of HF after cold stress, while the Yin tendency group showed the opposite. However, there were no statistically significant differences of heart rate variability analysis between the results of the two groups before and after cold stress. Recovery time of blood flow velocity by ultrasound Doppler was significantly different between the Yin and Yang tendency groups after cold stress. Conclusion: These results suggest that people with Yin or Yang tendency may show different responses in the autonomic nervous system. Further modified studies may include the responses to various manipulation techniques in acupuncture treatment and the individual responses according to pattern identification in traditional Korean medicine.

Construction of Ultrasound Pulsed Doppler Velocimeter (펄스 초음파 도플러 속도계의 제작에 관한 연구)

  • 현석봉;김수용;이재수
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.25-39
    • /
    • 1994
  • To measure the velocity of heart wall and local flow transctaneously in blood vessels, we have developed a single channel 3.1 MHz pulsed ultrasonic Doppler velocity meter. Ultrasound pluse width and repetition frequency (PRF) used in the velocity meter is 1 ${\mu}$sec 6kHz reapectively, and the Doppler shift of the backscattered echo signal is sensed in a phase detector by coherent demodulation method. From the output of the phase detector, the Doppler signal corresponding to the mean velocity of acoustic wave scatterers over a small region is obtained by using a range gate, sample holder and band-pass filter. Mean frequency of Doppler signal is estimated by zero-crossing counter and the instantaneous velocity of scatters is displayed as a function of time. It is possible to estimate velocity profile, volume flow and flow acceleration of vessels in man if the number of channels and range resolution in increased.

  • PDF

Portal blood flow measurement by doppler ultrasonography in dogs (도플러 초음파를 이용한 개의 간혈액량의 측정)

  • Sung, Jai-ki;Lee, Young-won;Lee, Hee-chon;An, Yong-ju;Choi, Ho-jung;Yoon, Jung-hee
    • Korean Journal of Veterinary Research
    • /
    • v.37 no.3
    • /
    • pp.661-668
    • /
    • 1997
  • Portal blood flow was measured with pulsed doppler ultrasound in thirty normal dogs. In normal dogs, the average portal blood flow velocity was $17.03{\pm}1.75cm/sec$ and the average portal blood flow was $41.59{\pm}10.10ml/min/kg$. The incident angle between the doppler beam and the portal vein averaged $65^{\circ}$. The average portal vein sectional area was $0.41{\pm}0.14cm^2$. The Congestion index was $0.0245{\pm}0.0081cm{\cdot}sec$. Conclusively, the spectral doppler ultrasonography was quick, non-invasive and simple diagnostic method in circulatory disorders of liver.

  • PDF