• 제목/요약/키워드: Ultrasound Diagnosis

검색결과 552건 처리시간 0.027초

초음파 진단 기기에서의 시간 이득 보상과 다이나믹 범위 조절을 위한 자동 최적화 알고리즘 (Automatic optimization for time gain compensation and dynamic range control in ultrasound diagnostic systems)

  • 이덕운;김용선;나종범
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.399-402
    • /
    • 2005
  • For efficient and accurate diagnosis of ultrasound images, the time gain compensation (TGC) and dynamic range (DR) control of the ultrasound echo signal are important. TGC is for compensating the attenuation of the ultrasound echo signal along the depth, and DR is used to control the image contrast. In this paper, we propose an algorithm for finding the optimized values of TGC and DR automatically. For TGC, the degree of compensation is determined along the depth based on the effective attenuation estimation of ultrasound signal. For DR optimization, we introduce a novel cost function on the basis of the characteristics of ultrasound image, which provides the minimum value at the optimal DR. Experiments have been performed by applying the proposed algorithm to a real US imaging system. The results show that the algorithm automatically can determine the values of TGC and DR in realtime so that the subjective quality of the corresponding US image may be good enough for diagnosis.

  • PDF

정상 골격근의 근전도 중앙주파수 및 초음파 영상 밀도 분석 (Analysis of sEMG Median frequency and Ultrasound Image Echodensity of Normal Skeletal Muscle)

  • 정진규;김용남;황태연;이정우;김태열
    • The Journal of Korean Physical Therapy
    • /
    • 제18권1호
    • /
    • pp.83-94
    • /
    • 2006
  • Purpose: This study conducts quantitative evaluation or structural and functional characteristics or normal skeletal muscle with ultrasound image and surface electromyography, and is to provide basic materials for utilizing ultrasound image analysis in physical therapy diagnosis and assessment of skeletal muscle. Methods: Measurement of three stages was conducted with 88 normal adults between their twenties and seventies, correlations and differences using collected data according to age and gender were compared and correlations among measured items were analyzed and then the following conclusions were obtained. Results: Analysis of ultrasound image of normal skeletal muscle showed that density, median frequency had the closest relations with age. In addition, it was found that there were high correlations between density explaining structural characteristics of skeletal muscle and median frequency explaining functional characteristics. Conclusion: Analysis of ultrasound image makes complex evaluation of structure and function of skeletal muscle possible when it is connected with functional evaluation method using physical measurement surface electromyography as well as quantitative evaluation of structural changes of skeletal muscle and is effective in complementing physical therapy diagnosis centering around functionality evaluation.

  • PDF

초음파를 이용한 턱관절질환의 진단과 초음파 가이드의 활용 (Diagnostic Application of Temporomandibular Joint Disorder and Ultra Sound Guided Oral &Maxillofacial application)

  • 성태환;박정현;김선종
    • 대한치과의사협회지
    • /
    • 제55권11호
    • /
    • pp.789-799
    • /
    • 2017
  • Ultrasound images are noninvasive, can be observed in real time, have no radiation exposure, do not cause pain, and are not restricted in use depending on the patient's prosthetic implant or medical condition. Since the use of ultrasound in the dental field was first applied for tooth preparation in 1957, the use of diagnostic ultrasound for the first time in 1963 has been reported. Currently, it is used in the diagnosis of soft tissue lesions such as malignant tumor or salivary gland disease, fine needle aspiration test, temporomandibular joint disease, lymph node metastasis, measurement of muscle thickness and inflammatory diseases, differentiation of periapical cyst and granulation tissue, measurement of periodontal tissue thickness. The ultrasound image can be visualized in real time. The clinician can explain the structure to the patient while consulting the patient and consult the patient. When injecting the drug into a specific site or aspirating a specific site or substance, So that it can be confirmed and practiced. Recently, ultrasonic equipment specialized in the dental field has been developed and marketed, and it is expected that the use of ultrasonic waves will become active in the dentistry. In the future, development of popular equipment with size and frequency suitable for dental diagnosis and various researches on maxillofacial ultrasonic anatomy. If clinical studies are continuously carried out to demonstrate efficacy, ultrasound is expected to aid in accurate diagnosis and treatment throughout the dentistry.

  • PDF

유방 초음파 영상의 컴퓨터 보조 진단을 위한 특성 분석 (Analysis of characteristics for computer-aided diagnosis of breast ultrasound imaging)

  • 엄상희;남재현;예수영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 추계학술대회
    • /
    • pp.307-310
    • /
    • 2021
  • 지난 몇년간 유방 초음파영상을 이용한 신호 및 영상처리 기술과 자동 영상 최적화 기술, 유방 종괴 자동 검출 및 분류 기술 등, 컴퓨터 보조 진단(computer-aided diagnosis, CAD)을 활용하는 연구들이 활발히 진행되어지고 있다. 컴퓨터진단기술이 개발될수록 암의 조기 발견이 정확하고 빠르게 진행되어 건강 보험과 환자의 검사 빙용을 줄일 수 있고 조직 검사에 대한 불안감을 없앨 수 있을 것으로 기대된다. 본 논문에서는 GLCM(gray level co-occurrence matrix)을 사용하여 초음파 영상에서 종양의 정량적 분석을 진행하여 컴퓨터보조 진단에 활용 가능성을 실험하였다.

  • PDF

INDUSTRIAL MATHEMATICS IN ULTRASOUND IMAGING

  • JANG, JAESEONG;AHN, CHI YOUNG
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제20권3호
    • /
    • pp.175-202
    • /
    • 2016
  • Ultrasound imaging is a widely used tool for visualizing human body's internal organs and quantifying clinical parameters. Due to its advantages such as safety, non-invasiveness, portability, low cost and real-time 2D/3D imaging, diagnostic ultrasound industry has steadily grown. Since the technology advancements such as digital beam-forming, Doppler ultrasound, real-time 3D imaging and automated diagnosis techniques, there are still a lot of demands for image quality improvement, faster and accurate imaging, 3D color Doppler imaging and advanced functional imaging modes. In order to satisfy those demands, mathematics should be used properly and effectively in ultrasound imaging. Mathematics has been used commonly as mathematical modelling, numerical solutions and visualization, combined with science and engineering. In this article, we describe a brief history of ultrasound imaging, its basic principle, its applications in obstetrics/gynecology, cardiology and radiology, domestic-industrial products, contributions of mathematics and challenging issues in ultrasound imaging.

The Difference of the Changes of Images on Ultrasound Scanner Setting Parameters

  • Kang, Hae-Kyung;Kim, Youn-Min;Kim, Hyun-Soo;Lee, Sung-Hee;Cho, Se-Youn;Lyu, Young-Eun;Jung, In-A
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.81-87
    • /
    • 2010
  • The setting parameters of ultrasound scanner give influences to change of image. Sonographers have used a Matlab program to make Low Contrast Sensitivity(LCS) value and compared original images in order to evaluate the use of the supersonic diagnosis machinery. We confirmed the change of image in Grayscale values using Photoshop program. Experiment equipment of our research used A Medison Accuvix V10, A Multi-Tissue Ultrasound Phantom(040 GSE) of CHRIS Company, A Adobe Photoshop CS4 Program, A Convex Probe, A USB memory stick, A Probe Fixation Equipment. The method used Gain, Dynamic Range(DR) of the setting parameters of ultrasound scanner and researched Gain and DR was set to 10 dB. We changed the different settings to see the changes of images using Grayscale values of a Photoshop program about tissue images of a phantom. This study evaluated DR and Gain whether it is an image controller to get the optimum contrast to produce an image to see the how effect on the images. We did not use Gateway in supersonic diagnosis machinery. We can easily open to open the files through Photoshop program before we get Digital Imaging and Communications in Medicine(DICOM) files use USB memory stick in supersonic diagnosis machinery. When we diagnosed the lesion of the patient with ultrasound, the contrast and the Gray scale value of image are very important. In this research, we determined the optimum setting parameters that provided useful information to diagnose disease and evaluated the change of improved images.

  • PDF

개에서 초음파를 이용한 간 종괴의 세침흡인술 증례 (Diagnostic Approach of Hepatic Mass using Ultrasound Guided Fine Needle Aspiration in a Dog)

  • 최호정;이기창;최민철;윤정희
    • 한국임상수의학회지
    • /
    • 제21권2호
    • /
    • pp.181-183
    • /
    • 2004
  • Hepatic mass was aspirated under the guidance with ultrasound in 9-year old female maltese with signs of anorexia, hematochezia, vomiting, depression, and abdominal distension. Radiographic and abdominal ultrasonographic examinations were performed, which revealed enlarged tubular shaped uterine mass and solitary, small round hyperechoic hepatic mass dorsal to gall bladder as an incidental finding. Ultrasound-guided fine needle aspiration was completed, but histologic confirmation should be made for definitive diagnosis by tissue core or wedge biopsy.

Technical Aspects of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

  • Kang, Hyo Jae;Hwangbo, Bin
    • Tuberculosis and Respiratory Diseases
    • /
    • 제75권4호
    • /
    • pp.135-139
    • /
    • 2013
  • Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is becoming a standard method for invasive mediastinal staging and for the diagnosis of paratracheal and peribronchial lesions. It is essential to understand the technical aspects of EBUS-TBNA to ensure safe and efficient procedures. In this review, we discuss the practical aspects to be considered during EBUS-TBNA, including anesthesia, manipulation of equipment, understanding mediastinal ultrasound images, target selection, number of aspirations needed per target, sample handling, and complications.

인공지능을 활용한 초음파영상진단장치에서 초음파 팬텀 영상을 이용한 정도관리의 정량적 평가방법 연구 (A Study on the Quantitative Evaluation Method of Quality Control using Ultrasound Phantom in Ultrasound Imaging System based on Artificial Intelligence)

  • 임연진;황호성;김동현;김호철
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권6호
    • /
    • pp.390-398
    • /
    • 2022
  • Ultrasound examination using ultrasound equipment is an ultrasound device that images human organs using sound waves and is used in various areas such as diagnosis, follow-up, and treatment of diseases. However, if the quality of ultrasound equipment is not guaranteed, the possibility of misdiagnosis increases, and the diagnosis rate decreases. Accordingly, The Korean Society of Radiology and Korea society of Ultrasound in Medicine presented guidelines for quality management of ultrasound equipment using ATS-539 phantom. The DenseNet201 classification algorithm shows 99.25% accuracy and 5.17% loss in the Dead Zone, 97.52% loss in Axial/Lateral Resolution, 96.98% accuracy and 20.64% loss in Sensitivity, 93.44% accuracy and 22.07% loss in the Gray scale and Dynamic Range. As a result, it is the best and is judged to be an algorithm that can be used for quantitative evaluation. Through this study, it can be seen that if quantitative evaluation using artificial intelligence is conducted in the qualitative evaluation item of ultrasonic equipment, the reliability of ultrasonic equipment can be increased with high accuracy.