Analysis of Risk Factors Affecting Breast Cancer Incidence : Breast Ultrasonography (유방암 발생에 영향을 미치는 위험인자 분석: 유방초음파 검진자 대상으로)

  • An, Hyun;Yang, Sung-Hee;Im, In-Chul;Lee, Jin-soo
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.289-295
    • /
    • 2017
  • In general, a number of studies have been conducted on factors affecting breast cancer development, but systematic investigations of risk factors are rare. The purpose of this study was to investigate the factors involved in breast cancer screening before breast ultrasound diagnosis and the risk factors associated with breast cancer screening by ultrasound. Self-administered questionnaire was performed on 417 patients who underwent breast ultrasonography and classified as benign and malignant. Breast cancer was associated with age, BMI, and type of medication(p<0.05). Multivariate analysis showed that the odds ratio was 4.93 times higher in the 50s compared to the less than 50s, 2.43 times higher in the obese group than in the normal group, 0.14 times and 0.16 times lower in hormonal replacement therapy(p<0.05). Therefore, as age increases, periodical examination of health and appropriate weight management are needed. So this study is expected to provide basic data for identification of risk factors affecting breast cancer development.

A Spleen Size Measured by Ultrasound in 20's Normal Adults (초음파검사에 의한 20대 정상 성인의 비장 크기)

  • Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.337-343
    • /
    • 2020
  • An enlarged spleen can be caused by infections, cirrhosis and other liver diseases, blood diseases characterized by abnormal blood cells, problems with the lymph system, immune diseases, or other conditions. Therefore, knowing the normal size of the spleen is helpful for the diagnosis of spleen and may be useful for follow-up. Ultrasonographic examination may be considered normal size if the maximum length is less than 12 cm and less than 5 cm in thickness, but may vary depending on sex and race. We aimed to present the normal range of spleen size by measuring the spleen size by ultrasonography in 20's normal adult Korean. The length of the male spleen was 10.95±1.07 cm and the width was 4.48±0.61 cm. The female length was 9.20±1.30 cm and the width was 3.55±0.44 cm. There was a significant difference (p<0.001). The spleen length increased with increasing height (r=.57) and there was a significant positive linear relationship with increasing spleen length as body weight increased(r=.63). In normal adults, 5 men and 2 women had a spleen length of more than 12 cm and 2 men with a size exceeding 13 cm.

Diagnosis of Chronic Kidney Disease using Sonography (초음파 영상을 이용한 만성 콩팥병의 진단)

  • Ahn, Yu-Ji;Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.153-159
    • /
    • 2017
  • Chronic kidney disease can be treated if it is detected early, but as the disease progresses, it becomes impossible to recover. Finally, renal replacement therapy such as transplantation or dialysis should be used. Ultrasonography is used to diagnose kidney cancer, inflammatory disease, nodular disease, and chronic kidney disease. It is used to identify information about degree of inflammation using information such as kidney size, internal echo characteristics. Currently, the degree of disease in the clinic uses the value of glomerular filtration rate. However, even in ultrasound, changes in the degree of inflammation and disease can be observed. In this study, we used ultrasound images to quantify the changes in brightness, size, cortex, and subclinical changes of the kidney with progression of the disease, and compared them with the glomerular filtration rate used in clinical practice. In 105 cases, we performed 35 cases of normal kidney, 35 cases of early kidney disease, and 35 cases of terminal kidney. The brightness of the cortex of the image was obtained and the difference in brightness between the cortex and the proximal portion was obtained by the slope. The graph of the portion which was not smooth due to the ultrasonic characteristics was used as the function regrass. The size reduction was obtained from the original data. The results were as follows: It was proportional to the glomerular filtration rate. It is considered that the algorithm can be applied to the disease if the algorithm study continues.

Radial Probe Endobronchial Ultrasound Using Guide Sheath-Guided Transbronchial Lung Biopsy in Peripheral Pulmonary Lesions without Fluoroscopy

  • Hong, Kyung Soo;Ahn, Heeyun;Lee, Kwan Ho;Chung, Jin Hong;Shin, Kyeong-Cheol;Jin, Hyun Jung;Jang, Jong Geol;Lee, Seok Soo;Jang, Min Hye;Ahn, June Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.4
    • /
    • pp.282-290
    • /
    • 2021
  • Background: Radial probe endobronchial ultrasound-guided transbronchial lung biopsy (RP-EBUS-TBLB) has improved the diagnostic yield of bronchoscopic biopsy of peripheral pulmonary lesions (PPLs). The diagnostic yield and complications of RP-EBUS-TBLB for PPLs vary depending on the technique, such as using a guide sheath (GS) or fluoroscopy. In this study, we investigated the utility of RP-EBUS-TBLB using a GS without fluoroscopy for diagnosing PPLs. Methods: We retrospectively reviewed data from 607 patients who underwent RP-EBUS of PPLs from January 2019 to July 2020. TBLB was performed using RP-EBUS with a GS without fluoroscopy. The diagnostic yield and complications were assessed. Multivariable logistic regression analyses were used to identify factors affecting the diagnostic yields. Results: The overall diagnostic accuracy was 76.1% (462/607). In multivariable analyses, the size of the lesion (≥20 mm; odds ratio [OR], 2.06; 95% confidence interval [CI], 1.27-3.33; p=0.003), positive bronchus sign in chest computed tomography (OR, 2.30; 95% CI, 1.40-3.78; p=0.001), a solid lesion (OR, 2.40; 95% CI, 1.31-4.41; p=0.005), and an EBUS image with the probe within the lesion (OR, 6.98; 95% CI, 4.38-11.12; p<0.001) were associated with diagnostic success. Pneumothorax occurred in 2.0% (12/607) of cases and chest tube insertion was required in 0.5% (3/607) of patients. Conclusion: RP-EBUS-TBLB using a GS without fluoroscopy is a highly accurate diagnostic method in diagnosing PPLs that does not involve radiation exposure and has acceptable complication rates.

Comparative Study on Signal Strength of Mechanical Index Using Ultrasound Machines with SonoVue Contrast (Sonovue 초음파 조영제를 이용한 장비 간 Mechanical Index의 변화에 따른 신호 강도 비교연구)

  • Kim, Myung-Seok;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • The purpose of this study was to compare the MI using SonoVue along with different machines output and to infer the meaning of the signal difference under the same condition. All of the comparative instruments showed strong signal values at early stage as MI value increased. Over time, the inter-instrumental signal values showed signal attenuation under all conditions except for 10 min of the condition of MI 0.1 of RS85A. E9 and EPIQ7 showed signal degradation due to microbubble collapse over time at all MI values. In the comparison of equipment, the signal strengths of MI 0.1, 0.2, and 0.4 were high in order of EPIQ7, RS85A and E9. In the quantitative analysis, there were statistically significant from the SNR and CNR that were obtained from RS85A and E9 (P-value<0.05). In the quantitative analysis, Epiq7 was statistically significant except for CNR as the MI value was changed In the contrast-enhanced ultrasound, even though MI value was low (MI <0.05), it will be helpful for diagnosis, controlling the MI and scan time because a difference in signal intensity was shown between the three machines.

Evaluation of Liver Function and Blood Exam including hs-CRP in Adults with Nonalcoholic Fatty Liver Findings (비알코올성 지방간 소견을 보이는 성인에 대한 간 기능 및 hs-CRP 혈액 검사 항목 평가)

  • Jeong-Mi, Park;Young-Hyun, Seo;Jong-Nam ,Song
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.943-952
    • /
    • 2022
  • As a test for diagnosing fatty liver, recently, ultrasound and blood exam are being performed simultaneously. In particular, in the case of high-sensitivity C-reactive protein in blood exam, it is used as an index indicating the level of inflammation in various parts of the body as well as cardiovascular diseases. Thus, this study was conducted to analyze the association between metabolic syndrome components, liver function, and high-sensitivity C-reactive protein levels according to the degree of nonalcoholic fatty liver, and use it as a clinical indicator for fatty liver diagnosis. Metabolic syndrome components, liver function and high-sensitivity C-reactive protein blood test values analyzed from 1,139 men and women over 20 years of age with nonalcoholic fatty liver in abdominal ultrasonography from March 2021 to August 2021 at the Korea Association of Health Promotion, Gwangju-Jeonnam Branch. Analyzed for all men and women, the blood test values for subjects with mild fatty liver were AST 30 U/L, ALT 32.1 U/L, γ-GTP 41.2 IU/L, and hs-CRP 0.14 mg/dL. These values were lower than the blood test values of subjects with moderate fatty liver (AST 38 U/L, ALT 47.6 U/L, γ-GTP 54.9 IU/L, hs-CRP 0.22 mg/dL) and was statistically significant (p<0.001). In this case of high-sensitivity C-reactive protein test, it is statistically significant, showing higher values in Subjects with moderate fatty liver than Subjects with mild fatty liver. thus, it is considered that hs-CRP can be used as clinical data for the prevention and management of fatty liver.

Delayed Cancer Diagnosis in Thyroid Nodules Initially Treated as Benign With Radiofrequency Ablation: Ultrasound Characteristics and Predictors for Cancer

  • Myoung Kyoung Kim;Jung Hee Shin;Soo Yeon Hahn;Haejung Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.9
    • /
    • pp.903-911
    • /
    • 2023
  • Objective: Regrowth after radiofrequency ablation (RFA) of symptomatic large thyroid nodules, initially treated as benign, sometimes turns out to be malignancies. This study aimed to assess the ultrasound (US) characteristics of thyroid nodules initially treated as benign with RFA and later diagnosed as cancers, predictive factors for cancers masquerading as benign, and methods to avoid RFA in these cancers. Materials and Methods: We reviewed the medical records of 134 consecutive patients with 148 nodules who underwent RFA between February 2008 and November 2016 for the debulking of symptomatic thyroid nodules diagnosed as benign using US-guided biopsy. We investigated the pre-RFA characteristics of the thyroid nodules, changes at follow-up after RFA, and the final surgical pathology. Results: Nodule regrowth after RFA was observed in 36 (24.3%) of the 148 benign nodules. Twenty-two of the 36 nodules were surgically removed, and malignancies were confirmed in seven (19.4% of 36). Of the 22 nodules removed surgically, pre-RFA median volume (range) was significantly larger for malignant nodules than for benign nodules: 22.4 (13.9-84.5) vs. 13.4 (7.3-16.8) mL (P = 0.04). There was no significant difference in the regrowth interval between benign and malignant nodules (P = 0.49). The median volume reduction rate (range) at 12 months was significantly lower for malignant nodules than for benign nodules (51.4% [0-57.8] vs. 83.8% [47.9-89.6]) (P = 0.01). The pre-RFA benignity of all seven malignant nodules was confirmed using two US-guided fine-needle aspirations (FNAs), except for one nodule, which was confirmed using US-guided core-needle biopsy (CNB). Regrown malignant nodules were diagnosed as suspicious follicular neoplasms by CNB. Histological examination of the malignant nodules revealed follicular thyroid carcinomas, except for one follicular variant, a papillary thyroid carcinoma. Conclusion: Symptomatic large benign thyroid nodules showing regrowth or suboptimal reduction after RFA may have malignant potential. The confirmation of these nodules is better with CNB than with FNA.

Role of Endoscopic Ultrasound in Evaluation of Pancreatic Neuroendocrine Tumors - Report of 22 Cases from a Tertiary Center in Iran

  • Haghighi, Shirin;Molaei, Mahsa;Foroughi, Forough;Foroutan, Mojgan;Dabiri, Reza;Habibi, Effat;Alizadeh, Amir Houshang Mohammad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4537-4540
    • /
    • 2012
  • Background: The pancreatic neuroendocrine tumor (pNET) is relatively rare and generally felt to follow an indolent course. EUS has an important role in detection of pNET. This is a review of clinical and radiological presentation and pathologic reports of 22 patients with pNET. Patients and methods: In this study we analyzed clinical and radiological presentations and pathologic reports of all relevant cases who were referred to Taleghani hospital for 3 years since 2008. Results: A total of 22 patients 28-74 years old (mean=49) were enrolled between 2008 and 2011. Among the total, 13 (59%) were male, 9 (41%) were female and 16 (72.7%) had functional tumors. The results of CT were negative in 12 (54%) cases but EUS was capable of detecting the lesions in these patients, cysts being found in 4 (19%) patients. Conclusion: EUS is a highly sensitive procedure for the localization of functional pNETs and especially insulinomas. Nonfunctional tumors were detected in more advanced and late stages and cystic lesions were more common in this group.

Development of Healthcare Data Quality Control Algorithm Using Interactive Decision Tree: Focusing on Hypertension in Diabetes Mellitus Patients (대화식 의사결정나무를 이용한 보건의료 데이터 질 관리 알고리즘 개발: 당뇨환자의 고혈압 동반을 중심으로)

  • Hwang, Kyu-Yeon;Lee, Eun-Sook;Kim, Go-Won;Hong, Seong-Ok;Park, Jung-Sun;Kwak, Mi-Sook;Lee, Ye-Jin;Lim, Chae-Hyeok;Park, Tae-Hyun;Park, Jong-Ho;Kang, Sung-Hong
    • The Korean Journal of Health Service Management
    • /
    • v.10 no.3
    • /
    • pp.63-74
    • /
    • 2016
  • Objectives : There is a need to develop a data quality management algorithm to improve the quality of healthcare data using a data quality management system. In this study, we developed a data quality control algorithms associated with diseases related to hypertension in patients with diabetes mellitus. Methods : To make a data quality algorithm, we extracted the 2011 and 2012 discharge damage survey data from diabetes mellitus patients. Derived variables were created using the primary diagnosis, diagnostic unit, primary surgery and treatment, minor surgery and treatment items. Results : Significant factors in diabetes mellitus patients with hypertension were sex, age, ischemic heart disease, and diagnostic ultrasound of the heart. Depending on the decision tree results, we found four groups with extreme values for diabetes accompanying hypertension patients. Conclusions : There is a need to check the actual data contained in the Outlier (extreme value) groups to improve the quality of the data.

Ultrasonographic Diagnosis of Subcutaneous Wooden Foreign Body (피하 조직에 발생한 나무 이물의 초음파 진단)

  • Choi, Ji-Hye;Keh, Seo-Yeon;Kim, Sung-Soo;Kim, Hye-Jin;Jang, Jae-Young;Choi, Hee-Yeon;Yoon, Jung-Hee
    • Journal of Veterinary Clinics
    • /
    • v.28 no.1
    • /
    • pp.163-172
    • /
    • 2011
  • Subcutaneous foreign body causes recurrent problems such as chronic soft tissue swelling and discharge. Wooden foreign body is one of the most common foreign bodies found in subcutaneous region including face, interdigit, and thoracic or abdominal area. This report demonstrated three dogs with wooden foreign body located in subcutaneous region of thoracic wall, abdominal wall and upper eyelid, respectively. Three dogs showed prominent soft tissue swelling adjacent the foreign body. A sinus or drainage tract was developed in two of these dogs. Ultrasonography revealed that hyperechoic linear structure accompanied acoustic shadow in all dogs, and which was diagnosed as a subcutaneous foreign body. Anechoic or hyperechoic fluid and hypoechoic tissue circumscribed the foreign body. A subcutaneous foreign body in case 3 was removed by clamp under ultrasound-guide with sedation. Sinography was performed in case 1 and clarified that the wooden foreign body did not perforate the thoracic wall and there was no direct communication into thoracic cavity. Ultrasonography and sinography can be used to identify the subcutaneous foreign body and evaluate the inflammatory reaction and relationship between foreign body and adjacent structures.