• Title/Summary/Keyword: Ultrasound Diagnosis

Search Result 539, Processing Time 0.031 seconds

Standardized Imaging and Reporting for Thyroid Ultrasound: Korean Society of Thyroid Radiology Consensus Statement and Recommendation

  • Min Kyoung Lee;Dong Gyu Na;Leehi Joo;Ji Ye Lee;Eun Ju Ha;Ji-Hoon Kim;So Lyung Jung;Jung Hwan Baek
    • Korean Journal of Radiology
    • /
    • v.24 no.1
    • /
    • pp.22-30
    • /
    • 2023
  • Ultrasonography (US) is a primary imaging modality for diagnosing nodular thyroid disease and has an essential role in identifying the most appropriate management strategy for patients with nodular thyroid disease. Standardized imaging techniques and reporting formats for thyroid US are necessary. For this purpose, the Korean Society of Thyroid Radiology (KSThR) organized a task force in June 2021 and developed recommendations for standardized imaging technique and reporting format, based on the 2021 KSThR consensus statement and recommendations for US-based diagnosis and management of thyroid nodules. The goal was to achieve an expert consensus applicable to clinical practice.

Large Mesenteric Pedunculated Lipoma in a Horse

  • Seokho Son;Seyoung Lee;Eun-bee Lee;Kyung-won Park;Ji-Youl Jung;Jae-Hoon Kim;Hyohoon Jeong;Jong-pil Seo
    • Journal of Veterinary Clinics
    • /
    • v.41 no.2
    • /
    • pp.123-126
    • /
    • 2024
  • A seven-month pregnant 15-year-old Thoroughbred mare presented with acute abdominal pain to Jeju National University Equine Hospital. At presentation, a nasogastric intubation revealed 10 L of gastric reflux; rectal palpation and ultrasound revealed dilated loops and thickening of the walls of the small intestine. An exploratory laparotomy revealed strangulation of the small intestine due to a large abdominal mass. The mass was double-ligated and resected blindly due to the short pedicle. An enterectomy was not performed as intestinal motility was detected following the mass removal. Histopathological examination confirmed that the mass was a lipoma, measuring 24 cm × 16 cm × 16 cm in size. On day 8 post-surgery, the mare was discharged without complications. This case report describes the diagnosis and treatment of strangulation of the small intestine by a pedunculated lipoma, thus providing useful information on lipoma in horses.

Safety and Efficacy of Ultrasound-Guided Percutaneous Core Needle Biopsy of Pancreatic and Peripancreatic Lesions Adjacent to Critical Vessels (주요 혈관 근처의 췌장 또는 췌장 주위 병변에 대한 초음파 유도하 경피적 중심 바늘 생검의 안전성과 효율성)

  • Sun Hwa Chung;Hyun Ji Kang;Hyo Jeong Lee;Jin Sil Kim;Jeong Kyong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1207-1217
    • /
    • 2021
  • Purpose To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy (USPCB) of pancreatic and peripancreatic lesions adjacent to critical vessels. Materials and Methods Data were collected retrospectively from 162 patients who underwent USPCB of the pancreas (n = 98), the peripancreatic area adjacent to the portal vein, the paraaortic area adjacent to pancreatic uncinate (n = 34), and lesions on the third duodenal portion (n = 30) during a 10-year period. An automated biopsy gun with an 18-gauge needle was used for biopsies under US guidance. The USPCB results were compared with those of the final follow-up imaging performed postoperatively. The diagnostic accuracy and major complication rate of the USPCB were calculated. Multiple factors were evaluated for the prediction of successful biopsies using univariate and multivariate analyses. Results The histopathologic diagnosis from USPCB was correct in 149 (92%) patients. The major complication rate was 3%. Four cases of mesenteric hematomas and one intramural hematoma of the duodenum occurred during the study period. The following factors were significantly associated with successful biopsies: a transmesenteric biopsy route rather than a transgastric or transenteric route; good visualization of targets; and evaluation of the entire US pathway. In addition, the number of biopsies required was less when the biopsy was successful. Conclusion USPCB demonstrated high diagnostic accuracy and a low complication rate for the histopathologic diagnosis of pancreatic and peripancreatic lesions adjacent to critical vessels.

Comparative Analysis Per Area of the Liver Diseases in Ultrasound Diagnosis of Healthcare Center (건강검진 초음파에서 지역별 간질환 유병률 비교 분석)

  • Lee, Mi-Yeon;Jung, Hong-Rayng;Lim, Chung-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.3
    • /
    • pp.278-287
    • /
    • 2009
  • The study find out developmental factors of the liver diseases in 29,531 subject of the healthy adults who diagnosed by using ultrasound at healthcare centers located at 6 cities around the nation. The results are as follows. Based on the result of the study, the liver diseases diagnosed by using ultrasound revealed to show 43.1% of prevalence, and the occurrence was significantly higher in male(23.3%) than in female (19.8%)(p<0.001). The disease revealed to show highest prevalence rate in regionally, Dae-jeon was found to record the highest prevalence by showing 49.6% (p<0.001). The order of liver disease prevalence was the highest in Dae-jeon(49.6%),which was followed by Seoul(48.2%), Busan(42.9%), Incheon(36.2%), Daegu(36.2%), Kangju(32.1%)(p<0.001). The order of hepatic disease prevalence was the highest in fatty liver (69.7%), which was followed by intrahepatic cysts (13.2%), intrahepatic calcification (9.6%), intrahepatic hemangioma (4.5%), intrahepatic tumor (1.4%), diffuse liver disease (1.0%),and liver cirrhosis (0.5%) (p<0.001). The liver disease revealed to show highest prevalence rate in 40s and regionally, disease was found to record the highest prevalence from 30s to 50s (p<0.001). The distribution of the liver diseases by sex revealed to show the higher occurrence of the fatty liver and the diffuse liver diseases in male, but the intrahepatic cysts, intrahepatic calcification and intrahepatic tumors were highly distributed in female. In the regional evaluation, the fatty liver was most often found in Busan, and intrahepatic cysts, intrahepatic hemangioma, intrahepatic calcification and intrahepatic tumors were highly found in Dae-jeon and Seoul revealed to show higher occurrence of diffuse liver disease than other regions (p<0.001). The multiple regression analysis for the related factors which affect the prevalence of the liver diseases resulted to show the higher prevalence by age. sex,

Assesment of Bone Strength Using a New Quantitative Ultrasound Device in Children with Renal Diseases (신질환 환아에서 초음파 골량측정법을 이용한 골상태 평가)

  • Kang Ju-Hyung;Shin Yun-Hye;Cho Nam-Han;Pai Ki-Soo
    • Childhood Kidney Diseases
    • /
    • v.9 no.1
    • /
    • pp.21-30
    • /
    • 2005
  • Purpose : Metabolic bone diseases have been mai or problems in children with renal diseases and steroid treatment is the main precipitating factor reducing bone mineral density(BMD). This study was performed to assess the prevalence of osteoporosis and to evaluate the clinical factors associated with decreased BMD in children with renal diseases. Methods : Forty-four children with renal diseases who were diagnosed at the Pediatric no phrology division of Ajou University hospital since Oct. 1994 were included. Using a new quantitative ultrasound device, BMD and the prevalence of osteoporosis were evaluated. The clinical and serological data were analyzed in association with decreased BMD. Results : A total of 44 patients were evaluated. The age at initial diagnosis was 6.7$\pm$4.2 years. At the time of evaluation, the chronological and bone age was 9.3$\pm$4.2 years and 8.2 $\pm$ 4.6 years, respectively. The renal diseases included nephrotic syndrome 24(54.5%), Henoch Schonlein purpura nephritis 7(15.9%), IgA nephropathy 6(13.9%), reflux nephropathy(RN) 2 (4.5%), and other renal disease 5(%). The prevalence of osteoporosis was 11%. There was no difference in the clinical factors between the long-term and the short-term treated steroid groups. Conclusion : The prevalence of osteoporosis was 12% in 44 children with renal diseases No significant factor was found in association with decreased BMD and there was no relationship between osteoporosis and steroid usage duration or cumulative dose. A new quantitative ultrasound, which is relatively easy to perform, especially in children, is expected to be in common use and will enable clinicians to evaluate metabolic bone disorders with ease.

  • PDF

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

Comparative Evaluations of Magnetic Resonance Image, Spiral Computed Tomography and Ultrasound in the Diasnosis of Experimental Diaphragmatic Rupture in the Rabbit (토끼의 횡격막 파열 진단에 있어서 자기공명영상, 나선형전산화단층촬영 및 초음파의 가치 비교)

  • 김학희;정승은;이배영;최병길;신경섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.154-161
    • /
    • 1997
  • Purpose: Traumatic rupture of the diaphragm is not easy to diagnose and often delayed. Delayed diagnosis of diaphragmatic rupture accompanied by higher chances of strangulation of herniated viscera which may result in higher morbility and mortality. The purpose of this study was to evaluate diagnostic accuracy of spiral CT, MRI and US for the diagnosis of diaphragmatic rupture in an animal model. Materials and Methods: Small, medium, and large sized transabdominal diaphragmatic ruptures were surgically made in experimental rabbits and then followed up with spiral CT, MR!, and US at 1 day, 3 day, and 1 week after operation. Results: US was superior to MR! or spiral CT in diagnosis of diaphragmatic rupture(P(0.05). The sensitivity and specificity were 94.4% and 92.9% for US, 54.0% and 85.7% for MRI, and 46.0% and 78.6% for spiral CT, respectively. The size of laceration was not related to diagnostic sensitivity in US. Sensitivity of MRI and spiral CT increased as the size of laceration were larger, but no statistical significance was present(P>0.05). All experimental animals developed pleural effusion or hemothorax one day after operation. In acute phase, US and MRI were more sensitive than spiral CT in detecting diaphragmatic rupture. Spiral CT was more sensitive than US and MRI in delayed phase but without statistical significance(P>0.05). In the experimental rabbits with accompanying visceral hernia through the diaphragmatic defect, diagnostic accuracy was found equally high among three image modalities(P>0.05). Conclusion: This study indicates that US is the most accurate diagnostic method in detecting injury to the diaphragm in a rabbit model. The findings obtained in this experimental study can be applied to the diaphragmatic rupture of human being.

  • PDF

Quantitative assessment of Endorectal Ultrasonography by using GLCM Algorithm (GLCM알고리즘을 이용한 경직장 초음파 영상의 정량적 평가)

  • Nho, Da-Jung;Kang, Min-Ji;Kim, Yoo-Kyeong;Seo, Ah-Reum;Lee, In-Ho;Jeong, Hee-Seong;Jo, Jin-Yeong;Ko, Seong-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.383-387
    • /
    • 2015
  • Bowel and rectal diseases are on the increase by irregular life and westernized eating habits of modern people, especially rectal cancer, which accounts for 50% of the entire colon cancer. For the initial rectal cancer, because there is no portion projecting on the surface, if not see inside the tissue with ultrasound, you make an errors that misdiagnosis as rectal abscess. However there is a need for more accurate diagnosis, because it is sometimes difficult to distinguish abscess from rectal cancer depending on staging, in spite of the ultrasonic diagnosis. Therefore, this study was performed quantitative analysis by using a computer algorithm for rectal cancer and abscess image. Each of 20 cases about normal, abscess and cancer by setting analysis region ($50{\times}50$ pixels) applies to GLCM algorithm and Autocorrelation, Max probability, Sum average, Sum variance in each image were analyzed by comparing the 4 single parameter. Consequently, The high lesion detection efficiency was presented 100% by the 3 parameter of Autocorrelation, Max probability, Sum variance and the parameter of Sum average presents 95% in cancer, more than 90% in abscess. Those parameters are valuable in distinction standard about normal, cancer and abscess in rectum. It is sufficient availability as a computer assisted diagnosis system depended on clinical using.

  • PDF

Urachal Anomalies in Children (소아 요막관 기형)

  • Kang, Eun-Young;Lee, Cheol-Koo;Park, Kwan-Hyeon;Seo, Jeong-Meen;Lee, Suk-Koo
    • Advances in pediatric surgery
    • /
    • v.11 no.2
    • /
    • pp.150-156
    • /
    • 2005
  • Failure of the urachus to regress completely results in anomalies that may be classified as patent urachus, urachal sinus, urachal cyst and bladder diverticula. The presenting symptoms of children with urachal anomalies are variable and uniform guidelines for diagnosis and treatment are lacking. The purpose of this study was to analyze our experience and develop conclusions regarding the presentation, diagnosis and treatment of urachal anomalies. We retrospectively analyzed the records of 32 patients who were admitted for urachal anomalies from March 1995 to February 2005. The age distribution of these patients at presentation ranged from 1 day to 14 years old (median age 1 month). There were 20 boys and 12 girls. The 32 cases comprised 13 cases of urachal sinus (40.6 %), 10 urachal cyst (31.3 %), and 9 patent urchus (28.1 %). In 30 patients ultrasonography was used for diagnosis and 2 patients with patent urachus were explored without using a diagnostic method. Twenty-three patients were confirmed by ultrasonography alone and 7 patients were examined using additional modalities, namely, computed tomography for 2 patients with an urachal cyst, magnetic resonance imaging for 1 patient with an urachal cyst, and fistulography for 3 patients with an urachal sinus. The presenting symptoms were umbilical discharge (14 patients), umbilical granuloma (8), abdominal pain and fever (3), fever (3), abdominal pain (2), and a low abdominal mass (2). Excision was performed in 29 patients, and 3 patients were conservatively managed. Urachal anomalies in children most frequently presented in neonates, and the most common complaint was umbilical discharge with infection. Urachal anomalies can be diagnosed by a physical examination and an appropriate radiographic test. Ultrasound was the most useful diagnostic method. Complete surgical excision of an urachal anomaly is recommended to avoid recurrence, and the rare development of carcinoma.

  • PDF

A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants (원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구)

  • Kim, Kyung-Cho;Kang, Suk-Chull;Goo, Charles;Kim, Jin-Ho;Park, Jae-Seok;Joo, Geum-Jong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.325-330
    • /
    • 2004
  • Several kinds of low voltage cables have been used in nuclear power plants for the supply of electric power, supervision, and the propagation of control signals. These low voltage tables must be inspected for safe and stable operation of nuclear power plants. In particular, the degradation diagnosis to estimate the integrity of low voltage rabies has recently been emphasized according to the long use of nuclear power plants. In order to evaluate their degradation, the surrounding temperature, hardness of insulation material, elongation at breaking point (EAB), etc. have been used. However, the measurement of temperature or hardness is not useful because of the absence of quantitative criteria; the inspection of a sample requires turning off of the power plant power; and, the electrical inspection method is not sufficiently sensitive from the initial through the middle stage of degradation. In this research, based on the theory that the ultrasonic velocity changes with relation to the degradation of the material, we measured the ultrasonic velocity as low voltage cables were degraded. To this end, an ultrasonic degradation diagnosis device was developed and used to measure the ultrasonic velocity with the clothing on the cable, and it was confirmed that the ultrasonic velocity changes according to the degradation of low voltage cables. The low voltage cables used in nuclear power plants were degraded at an accelerated rate, and EAB was measured in a tensile test conducted after the measurement of ultrasonic velocity. With the increasing degradation degree, the ultrasonic velocity decreased, whose potential as a useful parameter for the quantitative degradation evaluation was thus confirmed.