• Title/Summary/Keyword: Ultrasound Diagnosis

Search Result 539, Processing Time 0.026 seconds

Analyzation of Correlation between Clinical Factors and Carotid Ultrasonography Diagnosis (경동맥 초음파진단과 관련된 임상변수에 대한 분석)

  • Cho, Jin-Young;Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.705-713
    • /
    • 2020
  • Arteriosclerosis is a disease in which blood circulation is impaired due to loss of elasticity as blood vessels become narrower, and is a potential cause of recently increasing cardiovascular and cerebrovascular diseases. Carotid ultrasound is used as a predictor of cardiovascular and cerebrovascular diseases by evaluating the degree of atherosclerosis. Therefore, this paper attempted to investigate the correlation between the increase in the thickness of the inner media and various clinical variables in carotid ultrasound. Patients with carotid ultrasound findings were classified into three stages: mild intima thickening, sclerosis, and significant stenosis. CAVI (Carotid Ankle Vascular Index: vascular age) data measured in the degree and physical characteristics of the carotid artery(gender, age, body mass index, blood pressure), blood test(total cholesterol, triglycerides, high-density lipoprotein, low-density lipoprotein, creatine phosphokinase, fasting blood sugar), and arteriosclerosis test were collected. It was confirmed that the carotid intima thickness was correlated with variables such as hypertension, hyperlipidemia, and BMI, and also correlated with the risk factors of cardiovascular disease as CAVI increased.

Reproductive Management with Ultrasound Scanner-monitoring System for a High-yielding Commercial Dairy Herd Reared under Stanchion Management Style

  • Takagi, M.;Yamagishi, N.;Lee, I.H.;Oboshi, K.;Tsuno, M.;Wijayagunawardane, M.P.B.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.7
    • /
    • pp.949-956
    • /
    • 2005
  • The weekly ultrasound scanner (US) observations of reproductive organs in a commercial dairy herd with the popular stanchion style management were conducted for over 26 months. Based on reproductive records, the following were evaluated: 1) the effect of postpartum period commencement of US monitoring on herd reproductive efficacy, and 2) the effectiveness of a US monitoring-based diagnosis and subsequent treatments of reproductive disorders on postpartum reproductive efficiency. The reproductive parameters of cows, which were subjected to US monitoring between Days 30-40 (Day 0 = day of parturition), Days 41-50, Days 51-60, and above Day 61, were compared. The reproductive parameters of cows diagnosed as having reproductive disorders (RD) with US monitoring before or after the first artificial insemination (AI) were also compared. It was found that the day of commencement of US monitoring in cows diagnosed with and without RD significantly affected the period towards the first AI and the open period. In particular, cystic follicles and anoestrus detected either before or after the first AI significantly affected herd reproductive efficiency. The implementation of US monitoring improved reproductive efficiency by reducing the open period and increasing the number of milking cows in the herd. The results of this field trial indicate that the postpartum reproductive management of dairy cows with the use of the US monitoring system is one strategy to improve reproductive efficiency, especially in a high-yielding dairy herd reared stanchion management style.

A Clinical Consideration of Necrotizing Lymphadenitis (괴사성 림프절염에 대한 임상적 고찰)

  • 유명종;조우령;김학선;이재동;김명구
    • Korean Journal of Bronchoesophagology
    • /
    • v.6 no.2
    • /
    • pp.164-171
    • /
    • 2000
  • Background and Objectives: Necrotizing lymphadenitis or Kikuchi's disease is characterized by cervical lymphadenopathy of unknown etiology with unique histologic findings in young female patients. The importance of this disease lies in the fact that it can be easily misdiagnosed as malignant lymphoma, hence, clinicians need to aware of this disease entity. The purpose of this study is to report the clinicopathologic findings, radiographic findings, and many laboratory tests in order to contribute to the diagnosis and treatment of necrotizing lymphadenitis. Materials and Methods: We evaluated 31 patients, who were diagnosed as necrotizing lymphadenitis by excisional biopsy or fine needle aspiration cytology or ultrasound guided 18G cutting needle biopsy, retrospectively. Result : The median age was 24.8 years (range 12 to 43 years) and the male to female ratio was 1 : 2.4(9:22), with 14 females (45.1%) under 30 years. The common chief complaints were neck mass, easy fatigue and fever. Lymph node enlargement was limited to the cervical area in most cases (28cases : 90.3%). The involved lymph nodes were usually multiple (20cases : 64.5%), unilateral (26cases 83.9%) and small sized. Leukopenia (19cases : 61.3%) and elevation of ESR (18cases : 58.1%) appeared most frequently in the abnormal laboratory data. These symptoms will be gone spontaneoulsy without any specific treatment in several weeks or months. Conclusion : We should consider open biopsy or fine needle aspiration cytology or ultrasound guided cutting needle biopsy with lymph node in patients who have cervical lymphadenopathy with easy fatigue and fever, especially young women to exclude other conditions such as malignant lymphoma and tuberculosis, etc.

  • PDF

Role of fetal ultrasound in prenatally diagnosed de novo balanced translocations

  • Seong, Eui Sun;Youn, Hye Jin;Park, Min Kyung;Boo, Hye Yeon;Lee, Bom Yi;Ryu, Hyun Mee;Han, You Jung
    • Journal of Genetic Medicine
    • /
    • v.15 no.1
    • /
    • pp.8-12
    • /
    • 2018
  • Purpose: This study aimed to investigate fetal ultrasonographic findings in cases of prenatally diagnosed de novo balanced translocations and the role of fetal ultrasound in prenatal genetic counseling. Materials and Methods: We collected cases with de novo balanced translocations that were confirmed in chorionic villus sampling, amniocentesis, and cordocentesis between 1995 and 2016. A detailed, high-resolution ultrasonography was performed for prediction of prognosis. Chromosomes from the parents of affected fetuses were also analyzed to determine whether the balanced translocations were de novo or inherited. Results: Among 32,070 cases with prenatal cytogenetic analysis, 27 cases (1/1,188 incidence) with de novo balanced translocations were identified. Fourteen cases (51.9%) showed abnormal findings, and the frequency of major structural anomalies was 11.1%. Excluding the major structural anomalies, all mothers who continued pregnancies delivered healthy babies. Conclusion: Results of a detailed, high-resolution ultrasound examination are very important in genetic counseling for prenatally diagnosed de novo balanced translocations.

Application and usefulness of Ultrasound sonography in dentistry (영상치의학에서 초음파영상의 진단과유용성)

  • Choi, Yong Suk;Seo, Yoo Kyung;Kang, Ju Hee;Oh, Song Hee;Kim, Gyu Tae;Hwang, Eui Hwan
    • The Journal of the Korean dental association
    • /
    • v.55 no.11
    • /
    • pp.778-788
    • /
    • 2017
  • Ultrasound sonography(US) is used to evaluate various diseases of oral and maxillofacial region including salivary glands, soft tissue and jaw lesions because of easy accessibility and no hazard of ionizing radiation. Also, US can offer dynamic study showing real-time images during diagnostic or surgical procedure. US images provide accurate information about the internal features of lesions on the jaw prior to surgical treatment. Doppler images are used to visualize the vascular distribution of the lesions and to provide additional information to enhance diagnostic value. It is necessary to evaluate the diagnostic value of US and evaluate its usefulness by looking at clinical cases using US images. Therefore, US imaging may be recommended as an assistant image in evaluating jaw lesions. US images provided accurate information about the internal structure of lesions on the jaw prior to surgical treatment, and diagnostic value was enhanced by visualizing the vascular distribution of the lesion using doppler imaging. We report the protocol and suggest the effectiveness of US for various lesions and US-guided sialography.

  • PDF

Prospective Assessment of the Performance of a New Fine Needle Biopsy Device for EUS-Guided Sampling of Solid Lesions

  • El Hajj, Ihab I.;Wu, Howard;Reuss, Sarah;Randolph, Melissa;Harris, Akeem;Gromski, Mark A.;Al-Haddad, Mohammad
    • Clinical Endoscopy
    • /
    • v.51 no.6
    • /
    • pp.576-583
    • /
    • 2018
  • Background/Aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) remains the most common EUS-guided tissue acquisition technique. This study aimed to evaluate the performance of a new Franseen tip fine needle biopsy (FNB) device for EUSguided sampling of solid lesions and compare it with the historical FNA technique. Methods: $Acquire^{(R)}$ 22 G FNB needle (Boston Scientific Co., Natick, MA, USA) was used for solid tumor sampling (Study group). Tissue was collected for rapid on-site evaluation, and touch and crush preparations were made. Historical EUS-FNA samples obtained using $Expect^{(R)}$ 22 G FNA needle (Boston Scientific Co.) were used as controls (Control group). All specimens were independently evaluated by two cytopathologists blinded to the formal cytopathological diagnosis. Results: Mean cell block histology scores were significantly higher (p=0.046) in the FNB group (51 samples) despite a significantly lower (p<0.001) mean number of passes compared to the FNA group (50 specimens). The overall diagnostic yields for the FNB vs. FNA groups were 96% vs. 88%. The degree of tumor differentiation was adequately assessed in all cell block qualifying lesions in the FNB group. Two patients developed post-FNB abdominal pain. Conclusions: The new Franseen tip FNB device provides histologically superior and cytologically comparable specimens to those obtained by FNA, but with fewer passes.

Reliability of Quantifying Maximal Mouth Opening and Lateral Mandibular Shift in Individuals With and Without Temporomandibular Disorder Using Three-dimensional Ultrasound-based Motion Analysis

  • Oh, Jae-seop;Kim, Si-hyun;Kyung, Moon-su;Park, Kyue-nam
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.99-105
    • /
    • 2019
  • Background: Although magnetic resonance imaging is accurate, it is expensive to measure the movement of temporomandibular joint. The three-dimensional (3D) motion analysis system is an inexpensive measurement tool. Objects: This study examined the reliability of quantifying the mouth opening and lateral mandibular shift and differences between individuals with and without temporomandibular disorder (TMD) using the hygienic method of surface markers on the skin with 3D ultrasound-based motion analysis. Methods: This study included 24 subjects (12 with and 12 without TMD). Temporomandibular joint motion during mouth opening was recorded using two surface markers with 3D ultrasound-based motion analysis. An intraclass correlation coefficient [ICC (3,k)] was used to confirm the intrarater reliability of quantifying kinematic temporomandibular joint motion, and an independent t-test was used to evaluate differences in maximal mouth opening and lateral mandibular shift between the two groups. Results: Assessment of mouth opening and lateral mandibular shift showed excellent test-retest reliability with low standard error of measurement. The lateral mandibular shift and opening-lateral mandibular shift ratio were significantly increased in the TMD group during maximum mouth opening (p<.05). However, no significant difference in maximal mouth opening was observed between the groups with and without TMD (p>.05). Conclusion: This hygienic and simple surface marker method can be used to quantify the mouth opening and lateral mandibular shift at the end-range of mouth opening. The TMD group showed an increased lateral mandibular shift movement at the end-range of mouth opening. The lateral mandibular shift movement can be regarded as a symptom in the diagnosis and treatment of TMD.

Prolotherapy in Orthopedic Field (정형외과 영역에서의 증식치료)

  • Shon, Min Soo;Yoo, Jae Chul
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.2
    • /
    • pp.101-110
    • /
    • 2011
  • To describe the background, mechanism, clinical results and complications of prolotheapy based on the literature review. Prolotherapy is a minimally invasive injection-based treatment of chronic musculoskeletal pain, including ligament and joint laxity. The mechanism of this injection-based technique is to initiate a local inflammatory response with resultant tissue healing. The used proliferants are classified by bio-mechanism to act in three different ways as osmotic, irritants, and chemotatics. The most commonly used proliferant is hyperosmolar (10~25%) dextrose to act by osmotic rupture of cells. High resolution ultrasound imaging of musculoskeletal structure provide a more accurate diagnosis. Also ultrasound-guided intervention provides a more high efficacy and low rate of complications. The most common complication is local pain at the injected site, that is self-limited and good responsive to anti-inflammatory agents. Other complications are rare. It is reported that prolotherapy appears safe when performed by an experienced clinician. Prolotherapy has grown in popularity and has received significant recent attention. However there are limited evidence-based data supporting the indication and efficacy of prolotherapy in the treatment of chronic musculoskeletal pain or soft tissue injuries. Future studies are necessary to determine whether prolotherapy can play an independent and definitive role in a treatment for chronic musculoskeletal pain.

  • PDF

Automated Versus Handheld Breast Ultrasound for Evaluating Axillary Lymph Nodes in Patients With Breast Cancer

  • Sun Mi Kim;Mijung Jang;Bo La Yun;Sung Ui Shin;Jiwon Rim;Eunyoung Kang;Eun-Kyu Kim;Hee-Chul Shin;So Yeon Park;Bohyoung Kim
    • Korean Journal of Radiology
    • /
    • v.25 no.2
    • /
    • pp.146-156
    • /
    • 2024
  • Objective: Automated breast ultrasound (ABUS) is a relevant imaging technique for early breast cancer diagnosis and is increasingly being used as a supplementary tool for mammography. This study compared the performance of ABUS and handheld ultrasound (HHUS) in detecting and characterizing the axillary lymph nodes (LNs) in patients with breast cancer. Materials and Methods: We retrospectively reviewed the medical records of women with recently diagnosed early breast cancer (≤ T2) who underwent both ABUS and HHUS examinations for axilla (September 2017-May 2018). ABUS and HHUS findings were compared using pathological outcomes as reference standards. Diagnostic performance in predicting any axillary LN metastasis and heavy nodal-burden metastases (i.e., ≥ 3 LNs) was evaluated. The ABUS-HHUS agreement for visibility and US findings was calculated. Results: The study included 377 women (53.1 ± 11.1 years). Among 385 breast cancers in 377 patients, 101 had axillary LN metastases and 30 had heavy nodal burden metastases. ABUS identified benign-looking or suspicious axillary LNs (average, 1.4 ± 0.8) in 246 axillae (63.9%, 246/385). According to the per-breast analysis, the sensitivity, specificity, positive and negative predictive values, and accuracy of ABUS in predicting axillary LN metastases were 43.6% (44/101), 95.1% (270/284), 75.9% (44/58), 82.6% (270/327), and 81.6% (314/385), respectively. The corresponding results for HHUS were 41.6% (42/101), 95.1% (270/284), 75.0% (42/56), 82.1% (270/329), and 81.0% (312/385), respectively, which were not significantly different from those of ABUS (P ≥ 0.53). The performance results for heavy nodal-burden metastases were 70.0% (21/30), 89.6% (318/355), 36.2% (21/58), 97.3% (318/327), and 88.1% (339/385), respectively, for ABUS and 66.7% (20/30), 89.9% (319/355), 35.7% (20/56), 97.0% (319/329), and 88.1% (339/385), respectively, for HHUS, also not showing significant difference (P ≥ 0.57). The ABUS-HHUS agreement was 95.9% (236/246; Cohen's kappa = 0.883). Conclusion: Although ABUS showed limited sensitivity in diagnosing axillary LN metastasis in early breast cancer, it was still useful as the performance was comparable to that of HHUS.

Two-Dimensional Shear Wave Elastography Predicts Liver Fibrosis in Jaundiced Infants with Suspected Biliary Atresia: A Prospective Study

  • Huadong Chen;Luyao Zhou;Bing Liao;Qinghua Cao;Hong Jiang;Wenying Zhou;Guotao Wang;Xiaoyan Xie
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.959-969
    • /
    • 2021
  • Objective: This study aimed to evaluate the role of preoperative two-dimensional (2D) shear wave elastography (SWE) in assessing the stages of liver fibrosis in patients with suspected biliary atresia (BA) and compared its diagnostic performance with those of serum fibrosis biomarkers. Materials and Methods: This study was approved by the ethical committee, and written informed parental consent was obtained. Two hundred and sixteen patients were prospectively enrolled between January 2012 and October 2018. The 2D SWE measurements of 69 patients have been previously reported. 2D SWE measurements, serum fibrosis biomarkers, including fibrotic markers and biochemical test results, and liver histology parameters were obtained. 2D SWE values, serum biomarkers including, aspartate aminotransferase to platelet ratio index (APRi), and other serum fibrotic markers were correlated with the stages of liver fibrosis by METAVIR. Receiver operating characteristic (ROC) curves and area under the ROC (AUROC) curve analyses were used. Results: The correlation coefficient of 2D SWE value in correlation with the stages of liver fibrosis was 0.789 (p < 0.001). The cut-off values of 2D SWE were calculated as 9.1 kPa for F1, 11.6 kPa for F2, 13.0 kPa for F3, and 15.7 kPa for F4. The AUROCs of 2D SWE in the determination of the stages of liver fibrosis ranged from 0.869 to 0.941. The sensitivity and negative predictive value of 2D SWE in the diagnosis of ≥ F3 was 93.4% and 96.0%, respectively. The diagnostic performance of 2D SWE was superior to that of APRi and other serum fibrotic markers in predicting severe fibrosis and cirrhosis (all p < 0.005) and other serum biomarkers. Multivariate analysis showed that the 2D SWE value was the only statistically significant parameter for predicting liver fibrosis. Conclusion: 2D SWE is a more effective non-invasive tool for predicting the stage of liver fibrosis in patients with suspected BA, compared with serum fibrosis biomarkers.