• Title/Summary/Keyword: Ultrasound (US)

Search Result 242, Processing Time 0.023 seconds

Reliability and validity of a personal computer based muscle viewer for measuring upper trapezius and transverses abdominis muscle thickness

  • Jeong, Ju-Ri;Han, Ju Hee;Cho, Ji-Eun;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.155-161
    • /
    • 2016
  • Objective: This study aimed to investigate the reliability and validity of a personal computer-based muscle viewer (PC-BMW) compared with that of a portable ultrasound (P-US) for measuring upper trapezius (UT) and transversus abdominis (TrA) muscle thickness at rest and during contraction. Design: Observational inter-rater reliability study. Methods: Fifty-five healthy participants (25 men, 30 women) participated in this study. PC-BMW and P-US were randomly measured at the UT and TrA muscles. Two examiners randomly obtained the images of all participants in 3 test sessions lasting 2 days. Intra-class correlation coefficients (ICCs), standard error of measurement, contraction ratio, and correlation were used to estimate reliability and validity. Pearson's correlation coefficients were used to analyze the relationship between muscle thickness measures taken from PC-BMW and P-US. Results: The intra-rater reliability ICCs of UT and TrA muscle thickness for the PC-BMW were >0.995, indicating excellent reliability. Inter-rater reliability ICCs for the PC-BMW ranged from 0.963 to 0.987. The P-US also exhibited high reliability. A high correlation was found between the measurements of the two muscles in PC-BMW and P-US (p<0.01). Conclusions: PC-BMW provides clear and excellent images, is pocket-sized and less expensive than a conventional ultrasound imaging system. PC-BMW can be utilized variously and has the advantage of rehabilitative ultrasound imaging. More research is needed to evaluate the utility of PC-BMW for rehabilitation.

Thin and superthin perforator flap elevation based on preoperative planning with ultrahigh-frequency ultrasound

  • Visconti, Giuseppe;Bianchi, Alessandro;Hayashi, Akitatsu;Cina, Alessandro;Maccauro, Giulio;Almadori, Giovanni;Salgarello, Marzia
    • Archives of Plastic Surgery
    • /
    • v.47 no.4
    • /
    • pp.365-370
    • /
    • 2020
  • The ability to directly harvest thin and superthin perforator flaps without jeopardizing their vascularity depends on knowledge of the microsurgical vascular anatomy of each perforator within the subcutaneous tissue up to the dermis. In this paper, we report our experience with ultrahigh-frequency ultrasound (UHF-US) in the preoperative planning of thin and superthin flaps. Between May 2017 and September 2018, perforators of seven patients were preoperatively evaluated by both ultrasound (using an 18-MHz linear probe) and UHF-US (using 48- and 70-MHz linear probes). Thin flaps (two cases) and superthin flaps (five cases) were elevated for the reconstruction of head and neck oncologic defects and lower limb traumatic defects. The mean flap size was 6.5×15 cm (range, 5×8 to 7.5×23 cm). No complications occurred, and all flaps survived completely. In all cases, we found 100% agreement between the preoperative UHF-US results and the intraoperative findings. The final reconstructive outcomes were considered satisfactory by both the surgeon and the patients. In conclusion, UHF-US was found to be very useful in the preoperative planning of thin and superthin free flaps, as it allows precise anticipation of very superficial microvascular anatomy. UHF-US may represent the next frontier in thin, superthin, and pure skin perforator flap design.

A Clinical Significance of Ultrasound Guided Aspiration Cytology in Diagnosis of Impalpable Thyroid Nodule (비촉지성 갑상선 결절의 진단에서 초음파 유도하 세침검사법의 임상적 가치)

  • Choi Nak-Seon;Yoon Jung-Han;JaeGal Young-Jong
    • Korean Journal of Head & Neck Oncology
    • /
    • v.15 no.2
    • /
    • pp.189-193
    • /
    • 1999
  • Objectives: Fine needle aspiration cytology(FNAC) is a well established preoperative diagnostic procedure in the thyroid nodules. However, diagnostic accuracy of FNAC varies according to the size and the structural characteristics of thyroid nodule. We performed the ultrasound guided FNAC(US-guided FNAC) for impalpable thyroid nodule, and estimated the sampling accuracy rate through a comparison study between the cytologic diagnosis and the final histologic diagnosis of the postoperative specimens in order to determine clinical efficacy of the US-guided FNAC. Materials and Methods: We evaluated 117 patients underwent US-guided FNAC from January 1997 to December 1998. These patients had 129 thyroid nodules to need cytologic examination. Whereas the nodules were so no graphically classified into cystic, solid, and mixed type according to echo pattern, the aspirated thyroid specimens were classified into benign, malignant, suspicious, and insufficient. Results: Positive sampling for diagnositc examination was achieved in 75 nodules(58.1%), and US-guided FNAC in our study showed the accuracy rate of 95.2%, false positivity rate of 0%, and false negativity rate of 5.5%. Conclusions: US-guided FNAC is a powerful techniques for evaluating cytologic characterics and allowing a reliable diagnositc result in the impalpable thyroid nodule. However, the experienced technique is recommanded in order to obtain the sufficient samples for reliable results.

  • PDF

Performing Ultrasound-Guided Pharmacopuncture and Acupotomy for Nerve Entrapment in the Upper Extremity: A Guide for Teaching Procedural Skills

  • Taeseong Jeong;Eunbyul Cho;Sungha Kim;Seunghyun Oh;Suhak Kim;Jeongsu Park;Sungchul Kim
    • Journal of Acupuncture Research
    • /
    • v.41 no.2
    • /
    • pp.135-141
    • /
    • 2024
  • The use of ultrasound (US)-guided interventions has rapidly increased in Korean medicine (KM) to ensure the safety and accuracy of invasive procedures, such as pharmacopuncture and acupotomy. Although hands-on training is important for the acquisition of skills, it requires considerable time and cost. A detailed guide on the procedure and treatment regions is needed to ensure hygiene and safety during US-guided procedures in KM practice. In this study, we present the overall procedure, target structures, and treatment approaches of US-guided pharmacopuncture and acupotomy for nerve entrapment in the upper extremities of the cubital and radial tunnel, posterior interosseous nerve, carpal tunnel, and Guyon's canal syndrome. We believe that the findings of our study will serve as a foundation for future clinical research, practice, and education on US-guided KM procedures. Further research involving US-guided interventions should specify target structures in three-dimension to delineate the treatment areas.

A Study of Full Scale PUV/US Hybrid System for Contaminant Treatment in Groundwater (지하수 오염물질 처리를 위한 Full Scale PUV/US Hybrid System 연구)

  • Han, Jonghun;Park, Wonseok;Lee, Jongyeol;Heo, Jiyong;Her, Namguk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.10
    • /
    • pp.575-580
    • /
    • 2017
  • Chlorinated hydrocarbons (TCE and PCE), petroleum hydrocarbons (BTEX, PAHs, and TPH), and explosive compounds (TNT, RDX, and HMX) have been detected in underground water countrywide. The overall objective of this study is to evaluate sono-catalytic degradation coupled with the use of PUV in order to understand the fate and transport of a representative selection of non-biodegradable contaminants (i.e., TCE, PCE, BTEX, PAHs, TPH, TNT, RDX, and HMX) in groundwater. Both ultraviolet (UV) and ultrasound (US) systems are used in degrading of organic contaminants and they can thus be applicable simultaneously as an UV/US hybrid system in attempts further to increase the degradation efficiency. Results indicate that synergistic effect of UV/US hybrid system is closely correlated to the enhancement of sono-chemical reactivity with the UV-US interaction of increasing the formation rate of OH by providing additional $H_2O_2$ production through the pyrolysis of water molecules during UV/US hybrid irradiation.

The Application of High-Intensity Ultrasound on Wet-Dry Combined Aged Pork Loin Induces Physicochemical and Oxidative Alterations

  • Yu-Min Son;Eun-Yeong Lee;AMM Nurul Alam;Abdul Samad;Md Jakir Hossain;Young-Hwa Hwang;Jeong-Keun Seo;Chul-Beom Kim;Jae-Ha Choi;Seon-Tea Joo
    • Food Science of Animal Resources
    • /
    • v.44 no.4
    • /
    • pp.899-911
    • /
    • 2024
  • This research investigated the synergic outcome of high intensity ultrasound (HIU) treatment and wet-dry combined aging (WDCA) on physiochemical characteristics and lipid oxidation during refrigerated storage to ameliorate pork meat's quality and shelf life. The CIE b* values, cooking loss (CL %), and pH of the HIU treated samples were higher than those of the control over the aging period. They were significantly (p<0.05) modified by the aging period and ultrasound (US) treatment. However, the released water (RW %) and moisture were not significantly influenced by US treatment (p>0.05). The Warner-Bratzler shear force of HIU-treated samples was lower over control values except in 7-14 d, and it showed a significant difference between control and US treatment according to the significance of HIU (p<0.05). The thiobarbituric acid reactive substance of HIU-treated samples was significantly higher (p<0.05) than control values over the aging period. These results suggested that HIU treatment and WDCA showed a synergistic effect of maximizing the tenderness, but lipid oxidation was higher than before ultrasonic treatment. In agreement with this, the most favorable approach would involve implementing wet aging for a period of two weeks followed by dry aging for a period not exceeding one week after the application of HIU.

Ultrasound-guided Continuous Axillary Brachial Plexus Block Using a Nerve Stimulating Catheter: EpiStim Catheter

  • Choi, Sang Sik;Lee, Mi Kyoung;Kim, Jung Eun;Kim, Se Hee;Yeo, Gwi Eun
    • The Korean Journal of Pain
    • /
    • v.28 no.4
    • /
    • pp.287-289
    • /
    • 2015
  • Brachial plexus block (BPB) under ultrasound guidance has come to be widely used. However, nerve injury has been reported following ultrasound-guided BPB. We hypothesized that BPB under ultrasound guidance in conjunction with real-time electrical nerve stimulation would help us prevent nerve injury and do more successful procedure. Here, we report the successful induction and maintenance of ultrasound-guided BPB and the achievement of good peri- and postoperative pain control using a conductive catheter, the EpiStim$^{(R)}$.

Ultrasound-guided needle decompression and steroid injection for calcific tendinitis of the shoulder: risk factors for repeat procedures and outcome analysis

  • Kim, Su Cheol;Lee, Sang Min;Park, Gun Tae;Jang, Min Chang;Yoo, Jae Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.55-65
    • /
    • 2021
  • Background: Although ultrasound-guided needle decompression (US-GND) can treat calcific tendinitis of the shoulder effectively, repeat procedures might be required for unresolved symptoms. We evaluated the overall clinical outcomes of US-GND with subacromial steroid injection and the final results and factors predisposing toward repeat procedures. Methods: Ninety-eight patients who underwent US-GND for calcific tendinitis of the supraspinatus/infraspinatus were analyzed between March 2017 and December 2018. The clinical outcomes (pain visual analog scale, functional visual analog scale [FVAS], and American Shoulder and Elbow Surgeons [ASES] score) and final subjective satisfaction were compared between groups A (single US-GND) and B (repeat US-GND). The factors predisposing toward repeated US-GNDs were analyzed. Results: We found that 59.3% (58/98) of patient ASES scores were ≥80, and 73.5% of patients (72/98) were satisfied with the outcome. Group B (n=14) demonstrated a significantly higher rate of dominant-arm involvement compared to group A (78.6% vs. 48.8%, p=0.046). However, initial calcification size, shape, number, density, subscapularis involvement, lavage, and procedure time did not differ significantly between the groups. Group B showed poorer final FVAS (7 [interquartile range, 6-8] vs. 8 [interquartile range, 7-9], p=0.036) and subjective satisfaction compared to group A (satisfied: 5 [35.7%] vs. 67 [79.8%], p<0.001]. Conclusions: US-GND with subacromial steroid injection is a viable treatment option for calcific tendinitis of the shoulder. Dominant-arm involvement was the only independent factor for repeated US-GND. Final outcome of repeated US-GND for unimproved patients was promising; however, these outcomes were poor compared to those of the patients who improved after the first procedure.

A Study of Efficient Removal of 2-Methylisoborneol and Geosmin by Pulsed Ultraviolet and Ultrasound (효율적인 2-Methylisoborneol, Geosmin의 제거를 위한 Pulsed UV 공정과 Ultrasound 공정의 비교 연구)

  • Han, Jonghun;Hur, Jiyong;Kim, Kangwook;Lee, Junyoung;Park, Wonseok;Lee, Jongyeol;Her, Namguk
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • The degradation of off-flavors which is 2-Methylisoborneol (2-MIB) and geosmin by means of ultrasound (US) and pulsed ultraviolet (PUV) irradiation and its combination with catalyst (wire mesh, wire mesh coated TiO2, and TiO2) and additive (H2O2) were investigated via water system. A combination treatment of TiO2 and H2O2 heterogeneity with US (24 kHz) and PUV (6000 W) has shown improved results in destroying 2-MIB and geosmin, which may be attributed to chain reactions by the enhanced formation of hydroxyl radicals (·OH) through H2O2 dissociation and reactive oxide ions of TiO2 addition. Rapid degradation of off-flavors occurred within 2 min under PUV process with H2O2 100 mg/L (81.5% for 2- MIB; 79.3% for geosmin) and TiO2 100 mg/L (83.7% for 2-MIB; 79.8% for geosmin), while compared with H2O2 100 mg/L (58.4% for 2-MIB; 58.0% for geosmin) and TiO2 100 mg/L (59.2% for 2-MIB; 38.5% for geosmin) within 5 min under US process. Surprisingly, the emphasis was given on the comparison with the same injected energies between PUV and US on degradation efficiency. Based on the injected energy comparison, the US provided better degradation performance under equal input power of 200 kJ with H2O2 100 mg/L, while compared with H2O2 100 mg/L under PUV process. Our findings suggest that US can be more effective compared to PUV for the degradation of off-flavors in aspect of energy consumptions.